首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dental implants have to be placed with the long axis in different angulations due to the change in bone morphology. The objective of this study was to investigate the different bone remodeling response induced by the tilted dental implants and to assess whether it could lead to bone loss and implant failure. In this study, bone remodeling due to palato-labially inclined dental implants placed in the anterior maxillary incisor region was simulated. CT-based finite element models of a maxillary bone with dental implants were created herein. Five dental implants were placed at \(+10^{\circ }\), \(+5^{\circ }\), \(0^{\circ }\), \(-5^{\circ }\) and \(-10^{\circ }\), respectively. The remodeling progression was recorded and compared. Model \(-10^{\circ }\) (palatal side) shows the highest bone density values, but the inclined implant at \(+10^{\circ }\) (labial side) leads to significant bone loss. From a biomechanical perspective, it is speculated that a palatally inclined implant is more likely to enhance the bone density in the maxillary anterior region, but labial inclination of implant could jeopardize its stability.  相似文献   

2.

In this work, a three–dimensional model was developed to describe the passive mechanical behaviour of anisotropic skeletal muscle tissue. To validate the model, orientation–dependent axial (\(0^\circ\), \(45^\circ\), \(90^\circ\)) and semi–confined compression experiments (mode I, II, III) were performed on soleus muscle tissue from rabbits. In the latter experiments, specimen deformation is prescribed in the loading direction and prevented in an additional spatial direction, fibre compression at \(0^\circ\) (mode I), fibre elongation at \(90^\circ\) (mode II) and a neutral state of the fibres at \(90^\circ\) where their length is kept constant (mode III). Overall, the model can adequately describe the mechanical behaviour with a relatively small number of model parameters. The stiffest tissue response during orientation–dependent axial compression (\(-\,7.7\,\pm \,1.3\) kPa) occurs when the fibres are oriented perpendicular to the loading direction (\(90^\circ\)) and are thus stretched during loading. Semi–confined compression experiments yielded the stiffest tissue (\(-\,36.7\,\pm \,11.2\) kPa) in mode II when the muscle fibres are stretched. The extensive data set collected in this study allows to study the different error measures depending on the deformation state or the combination of deformation states.

  相似文献   

3.

The two-dimensional (2D) atomic localization is theoretically investigated via tunable surface plasmon polaritons (SPPs), generated on the metal (Ag) surface coupled to a quantum coherent three-level \(\lambda\)-type medium (\(^{87}\)Rb) embedded as a dielectric host. Such a useful scheme for highly precise atomic localization is reported by using the absorption spectrum of SPPs. Owing to space-dependent light–matter interaction, the sharp localized peaks are observed in a single wavelength domain of 2D space with maximum probability. By properly varying the system parameters, the precision and numbers of the localized peaks are controlled. Consequently, highly efficient and high-resolution atomic localization can be achieved in a region smaller than \(\lambda /20\times \lambda /20\). The spatial resolution of atomic localization is greatly improved as compared to the previously studied cases. These results may have potential useful applications in the fields of quantum nanoplasmonics, nanolithography, and nanophotonics.

  相似文献   

4.

Rhizopus oryzae PTCC 5263 capacity in synthesis of lactic acid (LA) from 10 g/l of soluble potato starch was determined using one-step fermentation process. Pellets were the favorable growing form of the free cells. The extent of the natural ability of the test fungus on biofilm formation on loofah sponge was examined by immobilizing R. oryzae (LIRO). The maximum LA concentration for the free cells and LIRO within 96 h was 3 and 4 g/l, respectively. In terms of specific starch utilization rate (\(q_{\text{s}}\)) and specific LA formation (\(q_{\text{p}}\)), LIRO performed more favorably compared to the free cells (\(q_{{{\text{s}}_{\text{F}} }} > q_{{{\text{s}}_{\text{LIRO}} }}\) and \(q_{{{\text{p}}_{\text{F}} }} < q_{{{\text{p}}_{\text{LIRO}} }}\)). Cell immobilization strategy was undertaken for the column reactor studies based on the statistically optimized levels of the inoculum size and temperature. Maximum production of the LA by the LIRO using an airlift reactor with net draft tube was 5 g/l obtainable within 48 h.

  相似文献   

5.

A Finite Element workflow for the multiscale analysis of the aortic valve biomechanics was developed and applied to three physiological anatomies with the aim of describing the aortic valve interstitial cells biomechanical milieu in physiological conditions, capturing the effect of subject-specific and leaflet-specific anatomical features from the organ down to the cell scale. A mixed approach was used to transfer organ-scale information down to the cell-scale. Displacement data from the organ model were used to impose kinematic boundary conditions to the tissue model, while stress data from the latter were used to impose loading boundary conditions to the cell level. Peak of radial leaflet strains was correlated with leaflet extent variability at the organ scale, while circumferential leaflet strains varied over a narrow range of values regardless of leaflet extent. The dependency of leaflet biomechanics on the leaflet-specific anatomy observed at the organ length-scale is reflected, and to some extent emphasized, into the results obtained at the lower length-scales. At the tissue length-scale, the peak diastolic circumferential and radial stresses computed in the fibrosa correlated with the leaflet surface area. At the cell length-scale, the difference between the strains in two main directions, and between the respective relationships with the specific leaflet anatomy, was even more evident; cell strains in the radial direction varied over a relatively wide range (\(0.36-0.87\)) with a strong correlation with the organ length-scale radial strain (\(R^{2}= 0.95\)); conversely, circumferential cell strains spanned a very narrow range (\(0.75-0.88\)) showing no correlation with the circumferential strain at the organ level (\(R^{2}= 0.02\)). Within the proposed simulation framework, being able to account for the actual anatomical features of the aortic valve leaflets allowed to gain insight into their effect on the structural mechanics of the leaflets at all length-scales, down to the cell scale.

  相似文献   

6.

Mechanical characterisation of the layer-specific, viscoelastic properties of the human oesophagus is crucial in furthering the development of devices emerging in the field, such as robotic endoscopic biopsy devices, as well as in enhancing the realism, and therefore effectiveness, of surgical simulations. In this study, the viscoelastic and stress-softening behaviour of the passive human oesophagus was investigated through ex vivo cyclic mechanical tests. Due to restrictions placed on the laboratory as a result of COVID-19, only oesophagi from cadavers fixed in formalin were allowed for testing. Three oesophagi in total were separated into their two main layers and the mucosa–submucosa layer was investigated. A series of uniaxial tensile tests were conducted in the form of increasing stretch level cyclic tests at two different strain rates: 1% s\(^{-1}\) and 10% s\(^{-1}\). Rectangular samples in both the longitudinal and circumferential directions were tested to observe any anisotropy. Histological analysis was also performed through a variety of staining methods. Overall, the longitudinal direction was found to be much stiffer than the circumferential direction. Stress-softening was observed in both directions, as well as permanent set and hysteresis. Strain rate-dependent behaviour was also apparent in the two directions, with an increase in strain rate resulting in an increase in stiffness. This strain rate dependency was more pronounced in the longitudinal direction than the circumferential direction. Finally, the results were discussed in regard to the histological content of the layer, and the behaviour was modelled and validated using a visco-hyperelastic matrix-fibre model.

  相似文献   

7.
8.

The sensory hairs of the Venus flytrap (Dionaea muscipula Ellis) detect mechanical stimuli imparted by their prey and fire bursts of electrical signals called action potentials (APs). APs are elicited when the hairs are sufficiently stimulated and two consecutive APs can trigger closure of the trap. Earlier experiments have identified thresholds for the relevant stimulus parameters, namely the angular displacement \(\theta \) and angular velocity \(\omega \). However, these experiments could not trace the deformation of the trigger hair’s sensory cells, which are known to transduce the mechanical stimulus. To understand the kinematics at the cellular level, we investigate the role of two relevant mechanical phenomena: viscoelasticity and intercellular fluid transport using a multi-scale numerical model of the sensory hair. We hypothesize that the combined influence of these two phenomena and \(\omega \) contribute to the flytrap’s rate-dependent response to stimuli. In this study, we firstly perform sustained deflection tests on the hair to estimate the viscoelastic material properties of the tissue. Thereafter, through simulations of hair deflection tests at different loading rates, we were able to establish a multi-scale kinematic link between \(\omega \) and the cell wall stretch \(\delta \). Furthermore, we find that the rate at which \(\delta \) evolves during a stimulus is also proportional to \(\omega \). This suggests that mechanosensitive ion channels, expected to be stretch-activated and localized in the plasma membrane of the sensory cells, could be additionally sensitive to the rate at which stretch is applied.

  相似文献   

9.

Population dynamics with demographic variability is frequently studied using discrete random variables with continuous-time Markov chain (CTMC) models. An approximation of a CTMC model using continuous random variables can be derived in a straightforward manner by applying standard methods based on the reaction rates in the CTMC model. This leads to a system of Itô stochastic differential equations (SDEs) which generally have the form \( d \mathbf {y} = \varvec{\mu } \, dt + G \, d \mathbf {W},\) where \(\mathbf {y}\) is the population vector of random variables, \(\varvec{\mu }\) is the drift vector, and G is the diffusion matrix. In some problems, the derived SDE model may not have real-valued or nonnegative solutions for all time. For such problems, the SDE model may be declared infeasible. In this investigation, new systems of SDEs are derived with real-valued solutions and with nonnegative solutions. To derive real-valued SDE models, reaction rates are assumed to be nonnegative for all time with negative reaction rates assigned probability zero. This biologically realistic assumption leads to the derivation of real-valued SDE population models. However, small but negative values may still arise for a real-valued SDE model. This is due to the magnitudes of certain problem-dependent diffusion coefficients when population sizes are near zero. A slight modification of the diffusion coefficients when population sizes are near zero ensures that a real-valued SDE model has a nonnegative solution, yet maintains the integrity of the SDE model when sizes are not near zero. Several population dynamic problems are examined to illustrate the methodology.

  相似文献   

10.
Dental implantology has high success rates, and a suitable estimation of how stresses are transferred to the surrounding bone sheds insight into the correct design of implant features. In this study, we estimate stress transfer properties of four commercial implants (GMI, Lifecore, Intri and Avinent) that differ significantly in macroscopic geometry. Detailed three-dimensional finite element models were adopted to analyse the behaviour of the bone-implant system depending on the geometry of the implant (two different diameters) and the bone-implant interface condition. Occlusal static forces were applied and their effects on the bone, implant and bone-implant interface were evaluated. Large diameters avoided overload-induced bone resorption. Higher stresses were obtained with a debonded bone-implant interface. Relative micromotions at the bone-implant interface were within the limits required to achieve a good osseointegration. We anticipate that the methodology proposed may be a useful tool for a quantitative and qualitative comparison between different commercial dental implants.  相似文献   

11.
In this paper, we develop a method for computing the variance effective size \(N_{eV}\) , the fixation index \(F_{ST}\) and the coefficient of gene differentiation \(G_{ST}\) of a structured population under equilibrium conditions. The subpopulation sizes are constant in time, with migration and reproduction schemes that can be chosen with great flexibility. Our quasi equilibrium approach is conditional on non-fixation of alleles. This is of relevance when migration rates are of a larger order of magnitude than the mutation rates, so that new mutations can be ignored before equilibrium balance between genetic drift and migration is obtained. The vector valued time series of subpopulation allele frequencies is divided into two parts; one corresponding to genetic drift of the whole population and one corresponding to differences in allele frequencies among subpopulations. We give conditions under which the first two moments of the latter, after a simple standardization, are well approximated by quantities that can be explicitly calculated. This enables us to compute approximations of the quasi equilibrium values of \(N_{eV}\) , \(F_{ST}\) and \(G_{ST}\) . Our findings are illustrated for several reproduction and migration scenarios, including the island model, stepping stone models and a model where one subpopulation acts as a demographic reservoir. We also make detailed comparisons with a backward approach based on coalescence probabilities.  相似文献   

12.

This study presents an application of machine learning (ML) methods for detecting the presence of stenoses and aneurysms in the human arterial system. Four major forms of arterial disease—carotid artery stenosis (CAS), subclavian artery stenosis (SAS), peripheral arterial disease (PAD), and abdominal aortic aneurysms (AAA)—are considered. The ML methods are trained and tested on a physiologically realistic virtual patient database (VPD) containing 28,868 healthy subjects, adapted from the authors previous work and augmented to include disease. It is found that the tree-based methods of Random Forest and Gradient Boosting outperform other approaches. The performance of ML methods is quantified through the \(F_1\) score and computation of sensitivities and specificities. When using six haemodynamic measurements (pressure in the common carotid, brachial, and radial arteries; and flow-rate in the common carotid, brachial, and femoral arteries), it is found that maximum \(F_1\) scores larger than 0.9 are achieved for CAS and PAD, larger than 0.85 for SAS, and larger than 0.98 for both low- and high-severity AAAs. Corresponding sensitivities and specificities are larger than 90% for CAS and PAD, larger than 85% for SAS, and larger than 98% for both low- and high-severity AAAs. When reducing the number of measurements, performance is degraded by less than 5% when three measurements are used, and less than 10% when only two measurements are used for classification. For AAA, it is shown that \(F_1\) scores larger than 0.85 and corresponding sensitivities and specificities larger than 85% are achievable when using only a single measurement. The results are encouraging to pursue AAA monitoring and screening through wearable devices which can reliably measure pressure or flow-rates.

  相似文献   

13.
The present study aimed to investigate the association of \(\hbox {g}.313\hbox {A}{>}\hbox {G}\) and \(\hbox {g}.341\hbox {C}{>}\hbox {T}\) polymorphisms of GSTP1 with coronary artery disease (CAD) in a subgroup of north Indian population. In the present case–control study, CAD patients (\(n = 200\)) and age-matched, sex-matched and ethnicity-matched healthy controls (\(n = 200\)) were genotyped for polymorphisms in GSTP1 using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method. Genotype distribution of \(\hbox {g}.313\hbox {A}{>}\hbox {G}\) and \(\hbox {g}.341\hbox {C}{>}\hbox {T}\) polymorphisms of GSTP1 gene was significantly different between cases and controls (\(P = 0.005\) and 0.024, respectively). Binary logistic regression analysis showed significant association of A/G (odds ratio (OR): 1.6, 95% CI: 1.08–2.49, \(P = 0.020\)) and G/G (OR: 3.1, 95% CI: 1.41–6.71, P \(=\) 0.005) genotypes of GSTP1 \(\hbox {g}.313\hbox {A}{\!>\!}\hbox {G}\), and C/T (OR: 5.8, 95% CI: 1.26–26.34, \(P = 0.024\)) genotype of GSTP1 \(\hbox {g}.341\hbox {C}{>}\hbox {T}\) with CAD. The A/G and G/G genotypes of \(\hbox {g}.313\hbox {A}{>}\hbox {G}\) and C/T genotype of \(\hbox {g}.341\hbox {C}{>}\hbox {T}\) conferred 6.5-fold increased risk for CAD (OR: 6.5, 95% CI: 1.37–31.27, \(P = 0.018\)). Moreover, the recessive model of GSTP1 \(\hbox {g}.313\hbox {A}{>}\hbox {G}\) is the best fit inheritance model to predict the susceptible gene effect (OR: 2.3, 95% CI: 1.11–4.92, \(P = 0.020\)). In conclusion, statistically significant associations of GSTP1 \(\hbox {g}.313\hbox {A}{>}\hbox {G}\) (A/G, G/G) and \(\hbox {g}.341\hbox {C}{>}\hbox {T}\) (C/T) genotypes with CAD were observed.  相似文献   

14.
A new method for the experimental determination of the permeability of a small sample of a fluid-saturated hierarchically structured porous material is described and applied to the determination of the lacunar–canalicular permeability \((K_\mathrm{LC})\) in bone. The interest in the permeability of the lacunar–canalicular pore system (LCS) is due to the fact that the LCS is considered to be the site of bone mechanotransduction due to the loading-driven fluid flow over cellular structures. The permeability of this space has been estimated to be anywhere from \(10^{-17}\;\) to \(10^{-25}\; \hbox {m}^{2}\) . However, the vascular pore system and LCS are intertwined, rendering the permeability of the much smaller-dimensioned LCS challenging to measure. In this study, we report a combined experimental and analytical approach that allowed the accurate determination of the \(K_\mathrm{LC}\) to be on the order of \(10^{-22}\; \hbox {m}^{2}\) for human osteonal bone. It was found that the \(K_\mathrm{LC}\) has a linear dependence on loading frequency, decreasing at a rate of \(2 \times 10^{-24}\; \hbox {m}^{2}\) /Hz from 1 to 100 Hz, and using the proposed model, the porosity alone was able to explain 86 % of the \(K_\mathrm{LC}\) variability.  相似文献   

15.
16.
Tumour metastasis in the lymphatics is a crucial step in the progression of breast cancer. The dynamics by which breast cancer cells (BCCs) travel in the lymphatics remains poorly understood. The goal of this work is to develop a model capable of predicting the shear stresses metastasising BCCs experience using numerical and experimental techniques. This paper models the fluidic transport of large particles (\(\eta =d_{\mathrm{p}}/W=0.1-0.4\) where \(d_{\mathrm{p}}\) is the particle diameter and W is the channel width) subjected to lymphatic flow conditions (\({ Re}=0.04\)), in a \(100\times 100\,\upmu \hbox {m}\) microchannel. The feasibility of using the dynamic fluid body interaction (DFBI) method to predict particle motion was assessed, and particle tracking experiments were performed. The experiments found that particle translational velocity decreased from the undisturbed fluid velocity with increasing particle size (5–14% velocity lag for \(\eta =0.1-0.3\)). DFBI simulations were found to better predict particle behaviour than theoretical predictions; however, mesh restrictions in the near-wall region (\(0.2\,\mathrm{W}>y>0.8\,\mathrm{W}\)) result in computationally expensive models. The simulations were in good agreement with the experiments (\(<12\%\) difference) across the channel (\(0.2\,\mathrm{W}\le y\le 0.8\,\mathrm{W}\)), with differences up to 25% in the near-wall region. Particles experience a range of shear stresses (0.002–0.12 Pa) and spatial shear gradients (\(0.004-0.137\,\hbox {Pa}/\upmu \hbox {m}\)) depending on their size and radial position. The predicted shear gradients are far in excess of values associated with BCC apoptosis (\(0.004-0.023\,\hbox {Pa}/\upmu \hbox {m}\)). Increasing our understanding of the shear stress magnitudes and gradients experienced by BCCs could be leveraged to elucidate whether a particular BCC size or location exists that encourages metastasis within the lymphatics.  相似文献   

17.
The basic reproduction number \(R_0\) is the average number of new infections produced by a typical infective individual in the early stage of an infectious disease, following the introduction of few infective individuals in a completely susceptible population. If \(R_0<1\) , then the disease dies, whereas for \(R_0>1\) the infection can invade the host population and persist. This threshold quantity is well studied for SIR compartmental or mean field models based on ordinary differential equations, and a general method for its computation has been proposed by van den Driessche and Watmough. We concentrate here on SIR epidemiological models that take into account the contact network N underlying the transmission of the disease. In this context, it is generally admitted that \(R_{0}\) can be approximated by the average number \(R_{2,3}\) of infective individuals of generation three produced by an infective of generation two. We give here a simple analytic formula of \(R_{2,3}\) for SIR cellular networks. Simulations on two-dimensional cellular networks with von Neumann and Moore neighborhoods show that \(R_{2,3}\) can be used to capture a threshold phenomenon related the dynamics of SIR cellular network and confirm the good quality of the simple approach proposed recently by Aparicio and Pascual for the particular case of Moore neighborhood.  相似文献   

18.
Changes in land use affect the terrestrial carbon stock through changes in the land cover. Research on land use and analysis of variations in carbon stock have practical applications in the optimization of land use and the mitigation of climate change effects. This study was conducted in Baixiang and Julu counties in the Taihang Piedmont by employing the trend analysis method to characterize the variation in county land use and carbon stock. The findings show that in both counties, agricultural and unused land areas decreased while built-up land area increased, and the reduction in cropland was the main reason behind the agricultural land reduction. An inflection point appeared on the cropland curves of Julu, because the cropland area decreased by 1576.97 hm\(^{2}\) from 2004 to 2006. Cropland area in Baixiang decreased from 1996 to 1998 by a total of 129.89 hm\(^{2}\) and then remained relatively stable after 1998. The total carbon storage and variation in land use in the two counties displayed similar trends. Total carbon reserves in Julu increased by 2.76 \(\times \) 10\(^{4}\) tC (carbon equivalent), while those in Baixiang decreased by 0.63 \(\times \) 10\(^{4}\) tC. Carbon stock of built-up land in Julu and Baixiang increased by 2.44 \(\times \) 10\(^{4}\) and 1.22 \(\times \) 10\(^{4}\) tC, respectively.  相似文献   

19.
There is an ongoing requirement for a clinically relevant, noninvasive technique to monitor the integrity of percutaneous implants used for dental restorations, bone-anchored hearing aids, and to retain extra-oral prostheses (ear, eye, nose, etc). Because of the limitations of conventional diagnostic techniques (CT, MRI), mechanical techniques that measure the dynamic response of the implant-abutment system are being developed. This paper documents a finite element analysis that simulates a transient response to mechanical impact testing using contact elements. The detailed model allows for a specific interface between the implant and bone and characterizes potential clinical situations including loss of bone margin height, loss of osseointegration, and development of a soft connective tissue layer at the bone-implant interface. The results also show that the expected difference in interface stiffness between soft connective tissue and osseointegrated bone will cause easily measurable changes in the response of the implant/abutment system. With respect to the loss of bone margin height, changes in the order of 0.2 mm should be detectable, suggesting that this technique is at least as sensitive as radiography. A partial loss of osseointegration, while not being as readily evident as a bone margin loss, would still be detectable for losses as small as 0.5 mm.  相似文献   

20.
A micro-finite element-based method to estimate the bone loading history based on bone architecture was recently presented in the literature. However, a thorough investigation of the parameter sensitivity and plausibility of this method to predict joint loads is still missing. The goals of this study were (1) to analyse the parameter sensitivity of the joint load predictions at one proximal femur and (2) to assess the plausibility of the results by comparing load predictions of ten proximal femora to in vivo hip joint forces measured with instrumented prostheses (available from www.orthoload.com). Joint loads were predicted by optimally scaling the magnitude of four unit loads (inclined \(-20^{\circ }\) to \(100^{\circ }\) with respect to the vertical axis) applied to micro-finite element models created from high-resolution computed tomography scans (\(30.3~\upmu \)m voxel size). Parameter sensitivity analysis was performed by varying a total of nine parameters and showed that predictions of the peak load directions (range 10\(^{\circ }\)\(30^{\circ }\)) are more robust than the predicted peak load magnitudes (range 2344.8–4689.5 N). Comparing the results of all ten femora with the in vivo loading data of ten subjects showed that peak loads are plausible both in terms of the load direction (in vivo: \(18.2\pm 2.0^{\circ }\), predicted: \(20.0^{\circ }\)) and magnitude (in vivo: \(2707.6\pm 443.3~\hbox {N}\), predicted: \(3372.2\pm 597.9~\hbox {N}\)). Overall, this study suggests that micro-finite element-based joint load predictions are both plausible and robust in terms of the predicted peak load direction, but predicted load magnitudes should be interpreted with caution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号