首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rotary blood pumps have been researched as implantable ventricular assist devices for years. To further reduce the complex of implanted axial pumps, the authors proposed a new concept of intraaortic axial pump, termed previously as "dynamic aortic valve (DAV)". Instead of being driven by an intraaortic micro-electric motor, it was powered by a magnetic field from outside of body. To ensure the perfusion of coronary artery, the axial flow pump is to be implanted in the position of aortic valve. It could serve as either a blood pump or a mechanical valve depending on the power input. This research tested the feasibility of the new concept in model study. A column, made from permanent magnet, is jointed to an impeller in a concentric way to form a "rotor-impeller". Supported by a hanging shaft cantilevered in the center of a rigid cage, the rotor-impeller can be turned by the magnetic field in the surrounding space. In the present prototype, the rotor is 8 mm in diameter and 15 mm in length, the impeller ha  相似文献   

2.
我们正在研制一种心室辅助径流泵,可在体外循环中代替血泵使用,也可作为心衰病人短期心脏辅助泵使用。此种无密封件的径流的泵的轴尖支承结构由一根据氧化铝陶瓷制成的叶轮轴和两只氧化锆陶瓷制成的轴尖轴承组成。叶轮的外径为72毫米,进流处直径为24毫米。位于叶轮上表面的六个叶片的进流侧高度为5.5毫米。出流侧高度为3毫米。  相似文献   

3.
A variety of methods by which mechanical circulatory support (MCS) can be provided have been described. However, the haemodynamic benefits of the different methods have not been adequately quantified. The aim of this paper is to compare the haemodynamic effects of six forms of MCS by numerical simulation. Three types of ventricular assist device (VAD) are studied: positive displacement; impeller and a novel reciprocating-valve design. Similarly, three pumping modes are modelled: constant flow; counterpulsation and copulsation. The cardiovascular system is modelled using an approach developed previously, using the concentrated parameter method by considering flow resistance, vessel elasticity and inertial effects of blood in individual conduit segments. The dynamic modelling of displacement and impeller pumps is represented by VAD inlet/outlet flow-rate changes. The dynamics of the reciprocating-valve pump is modelled with a specified displacement profile. Results show that in each simulation, the physiological variables of mean arterial pressure and systemic flow are adequately maintained. Modulation of the impeller pump flow profile produces a small (5 mmHg) oscillatory component to arterial pressure, whereas the displacement and reciprocating-valve pumps generate substantial arterial pressure and flow pulsatility. The impeller pump requires the least power input, the reciprocating valve pump slightly more, and the displacement pump the most. The in parallel configuration of the impeller and displacement pump designs with respect to the left ventricle provides near complete unloading and can cause the aortic valve to remain closed throughout the entire cardiac cycle with the attendant risk of aortic valve leaflet fusion following prolonged support. The in series configuration of the reciprocating-valve pump avoids this shortcoming but activation must be carefully synchronized to the cardiac cycle to allow adequate coronary perfusion. The reciprocating-valve pump is associated with haemodynamic advantages and a favourable power consumption.  相似文献   

4.
21毫米人造心脏瓣膜泵的设计及研制   总被引:1,自引:0,他引:1  
为了研究能够长期置入主动脉瓣环的左心室辅助装置,研制出直径21毫米重27克可植入的主动脉瓣膜泵.装置包括一个转子和一个定子.转子由驱动磁钢和叶轮组成;定子装有带铁心的电机线圈和出口导叶.装置被置於主动脉瓣位置,所以不占用额外的解剖空间.血泵能像自然心脏一样直接将血液由心室输送到主动脉,不需要连接管道和旁路,因此对自然生理循环的干扰可以减到最低.血泵流量由最大到零周期变化.血液动力学测试表明,当血泵转速为17500转/分钟时,可以产生流量5升/分钟、压力增益50毫米汞柱的血流;同一转速下,当流量为零时,血泵能保持主动脉舒张压为80毫米汞柱.  相似文献   

5.
Gene flow from genetically modified (GM) crops to conventional non-GM crops is a serious concern for protection of conventional and organic farming. Gene flow from GM watermelon developed for rootstock use, containing cucumber green mottle mosaic virus (CGMMV)-coat protein (CP) gene, to a non-GM isogenic control variety “Clhalteok” and grafted watermelon “Keumcheon” was investigated in a small scale field trial as a pilot study. Hybrids between GM and non-GM watermelons were screened from 1304 “Chalteok” seeds and 856 “Keumcheon” seeds using the duplex PCR method targeting theCGMMV- CP gene as a marker. Hybrids were found in all pollen recipient plots. The gene flow frequencies were greater for “Chaiteok” than for “KeumcheonD; with 75% outcrossing in the “Chaiteok” plot at the closest distance (0.8 m) to the GM plot. A much larger scale field trial is necessary to identify the isolation distance between GM and non-GM watermelon, as the behaviors of insect pollinators needs to be clarified in Korea.  相似文献   

6.
A portable flow chamber for in situ determination of benthic metabolism   总被引:1,自引:0,他引:1  
1. Many stream ecologists are interested in determining the metabolic rates of benthic organisms, particularly those of production and respiration. It is often necessary to make these measurements on fresh material in the field at remote sites. Recirculating chambers are commonly used for this purpose.
2. A broad variety of recirculating chambers are described in the literature, but each design has inherent limitations. The most common are inability to control flow in the chamber and match it with external flow rates, and a lack of the power required to do this for extended periods. Alteration of spectral irradiance, temperature rise and elevated internal chamber pressures are additional limitations that have received little attention.
3. We have designed and constructed a flow chamber that eliminates some of these problems. The chamber utilizes a DC motor-driven propeller as an efficient recirculator (axial impeller), minimizing power requirements and it is constructed of UVB transparent acrylic to allow a full spectral complement of solar irradiance in the interior. Modular components allow the chamber to be taken apart quickly for cleaning and replacement of parts, making it more functional than some previous designs.
4. The axial impeller chamber was compared to a similar sized conventional chamber that had a small diameter return line and a high capacity centrifugal pump. The axial impeller chamber had less of a temperature rise during field incubations, lower power consumption and less internal pressure in the return line when producing equivalent water velocities.
5. The reported axial impeller design had relatively homogeneous velocity across the working section relative to other chambers and was capable of water velocities in excess of 1 m s–1.  相似文献   

7.
The objective study was to estimate the rheological properties and physiological compatibility of the blood pump by simulating the internal flow field of the blood pump. In this study we use computational fluid dynamics method to simulate and analyse two models of axial blood pumps with a three-blade diffuser and a six-blade diffuser, named pump I and pump II, respectively, and to compare the flow patterns of these two kinds of blood pumps while both of them satisfy the conditions of the normal human blood differential pressure and blood flow. Results indicate that (i) the high shear force occurs between the diffuser and the rotor in which the crucial place leads to haemolysis and (ii) under the condition of 100 mmHg pressure head and 5 l/min flow rate, the difference between the two kinds of blood pumps, as far as the haemolytic performance is concerned, is notable. The haemolysis index of the two pumps is 0.32% and 0.2%. In conclusion, the performance of the blood pump is influenced by the diffusers' blade number. Pump II performed better than pump I, which can be the basic model for blood pump option.  相似文献   

8.
In the experimental and clinical support of the failing heart, the impeller-type centrifugal pumps continue to be of interest because of their inherent advantages; however, the blood compatibility of these pumps still remains to be improved. From the viewpoint of haemodynamics, thrombosis and haemolysis could be reduced by eliminating the stagnation and turbulence of blood flow within the pump, which frequently takes place near the blood contracting surfaces of the pump, when the impeller contours do not coincide with the stream surfaces of the blood. It is suggested that it could be advantageous to design impeller contours according to the stream surfaces, by solving the partial differential equations of continuity, motion and energy. An impeller shroud and vane based on this approach would be fully rinsed by non-turbulent flow and there would then be neither stagnation nor turbulence within the pump, with the result that thrombosis and haemolysis could be reduced. A new impeller pump, developed according to this method, was evaluated as a left ventricular device in four dogs. The bypass flow was controlled at 40–50% of the total flow, each test lasting 6 h. All of the haematological parameters, measured every 2 h, remained within normal range. There was no thrombosis, and coagulation in the pump was avoided by a small dose of heparin to maintain the activated coagulation time (ACT) under 200″ in the experiments.  相似文献   

9.
Berberis buxifolia Lam., known as “Calafate”, is a plant native to Argentina that exhibits antimicrobial activity. This biological activity is attributed to the isoquinoline alkaloid berberine. The aim of this research was to test the antimicrobial properties of different extracts of this species, taking berberine as the reference molecule, and to examine if the expression of bacterial multidrug resistance (MDR) efflux pumps could be responsible for possible resistance mechanisms. To this end, a wild-type and a mutant strain of Staphylococcus aureus with a defective MDR efflux pump were used and the minimum inhibitory concentrations of the extracts were determined. The studies were carried out with infusions of in vivo shoots and “Calafate” commercial tea, as well as with the media derived from shoot cultures incubated with different plant growth regulators (thidiazuron, picloram, and jasmonic acid). As far as antimicrobial activity is concerned, all the extracts tested were significantly more effective than berberine standard. “Calafate” commercial tea and shoot tea had inhibitory concentrations similar to the one observed for ampicillin standard. The media from the shoot cultures, however, were significantly more effective than all the others, particularly the one derived from jasmonic acid, suggesting the presence of compounds that could be acting synergistically with berberine. There were no differences in antimicrobial activity against the wild-type and the mutant S. aureus; no definite conclusions could be drawn concerning the relationship between MDR pumps and possible pathogen resistance to extracts of B. buxifolia.  相似文献   

10.
We conducted a 2-year field assessment of the gene flow from genetically modified (GM) chili pepper (Capsicum annuum L.), containing the PepEST (pepper esterase) gene, to a non-GM control line “WT512” and two commercial hybrid cultivars, “Manidda” and “Cheongpung Myeongwol (CM).” After seeds were collected from the pollen-recipient non-GM plants, hybrids between them and the GM peppers were screened by a hygromycin assay. PCR with the targeting hpt gene was performed to confirm the presence of transgenes in hygromycin-resistant seedlings. Out of 7,071 “WT512” seeds and 6,854 “Manidda” seeds collected in 2006, eight and 12 hybrids, respectively, were detected. In 2007, 33 hybrids from 3,456 “WT512” seeds and 50 hybrids from 3,457 “CM” seeds were found. The highest frequency of gene flow, 6.19%, was observed in that 2007 trial. These results suggest that a limited isolation distance would be sufficient to prevent gene flow from GM to conventionally bred chili peppers.  相似文献   

11.
Water and solute flows in the coupled system of xylem and phloem were modeled together with predictions for xylem and whole stem diameter changes. With the model we could produce water circulation between xylem and phloem as presented by the Münch hypothesis. Viscosity was modeled as an explicit function of solute concentration and this was found to vary the resistance of the phloem sap flow by many orders of magnitude in the possible physiological range of sap concentrations. Also, the sensitivity of the predicted phloem translocation to changes in the boundary conditions and parameters such as sugar loading, transpiration, and hydraulic conductivity were studied. The system was found to be quite sensitive to the sugar-loading rate, as too high sugar concentration, (approximately 7 MPa) would cause phloem translocation to be irreversibly hindered and soon totally blocked due to accumulation of sugar at the top of the phloem and the consequent rise in the viscosity of the phloem sap. Too low sugar loading rate, on the other hand, would not induce a sufficient axial water pressure gradient. The model also revealed the existence of Münch “counter flow”, i.e., xylem water flow in the absence of transpiration resulting from water circulation between the xylem and phloem. Modeled diameter changes of the stem were found to be compatible with actual stem diameter measurements from earlier studies. The diurnal diameter variation of the whole stem was approximately 0.1 mm of which the xylem constituted approximately one-third.  相似文献   

12.
We studied entrainment of the catalytic cycle of the Na/K pumps by an imposed external AC electric field. Our results show that a well designed dichotomous oscillating electric field with a frequency close to the pumps’ natural turnover rate can synchronize the pump molecules. Characteristics of the synchronized pumps include: (1) outward pump currents responding to Na-extrusion and inward pump currents responding to K-pumping in are separated; (2) magnitude of the outward pump currents can be up to three times higher than that of the randomly paced pump currents; (3) magnitude ratio of the outward over inward pump currents reveals the 3:2 stoichiometry of the pumps. We, further, gradually increased the field oscillating frequency in a stepwise pattern and kept pump synchronization in each step. We found that the pumps’ turnover rate could be modulated up as the field frequency increased. Consequently, the pump currents significantly increased by many fold. In summary, these results show that the catalytic cycle of Na/K pumps can be synchronized and modulated by a well designed oscillating electric field resulting in activation of the pump functions.  相似文献   

13.
Zornia subsessilis, a new species from Serra do Cabral, Minas Gerais State, Brazil, is described and illustrated on the basis of field and herbarium studies. It belongs to Zornia section Zornia of subgenus Zornia and it appears to be restricted to “campo rupestre” (rocky fields) within the “cerrado” biome. This new species is characterized by its sessile to subsessile leaves, fruits with articles 4 to 5 mm long and with bristles up to 3.5 mm long.  相似文献   

14.
The continuous flow ventricular assist device (VAD) is a miniature centrifugal pump, fully suspended by magnetic bearings, which is being developed for implantation in humans. The CF4 model is the first actual prototype of the final design product. The overall performances of blood flow in CF4 have been simulated using computational fluid dynamics (CFD) software: CFX, which is commercially available from ANSYS Inc. The flow regions modeled in CF4 include the inlet elbow, the five-blade impeller, the clearance gap below the impeller, and the exit volute. According to different needs from patients, a wide range of flow rates and revolutions per minute (RPM) have been studied. The flow rate-pressure curves are given. The streamlines in the flow field are drawn to detect stagnation points and vortices that could lead to thrombosis. The stress is calculated in the fluid field to estimate potential hemolysis. The stress is elevated to the decreased size of the blood flow paths through the smaller pump, but is still within the safe range. The thermal study on the pump, the blood and the surrounding tissue shows the temperature rise due to magnetoelectric heat sources and thermal dissipation is insignificant. CFD simulation proved valuable to demonstrate and to improve the performance of fluid flow in the design of a small size pump.  相似文献   

15.
A new species Dolichopteryx minuscula is described on the basis of three specimens [49.4–59.6 mm in standard length (SL)] collected from the Indo-West Pacific. The new species is characterized by pouchlike eyes with a small lens (lens diameter 2.2% SL), an adipose fin, the anal fin base originating posterior to the dorsal fin base, and 16–17 (= 5–6 + 1 + 10–11) gill rakers. Total fecundity was relatively low, only 658 ova being obtained from one specimen, despite the ovary being mature. Ovarian eggs were clearly subdivided into “undeveloped” (0.1–0.7 mm diameter classes, n = 561) and “developed” (1.0–1.3 mm classes, n = 97) groups, based on their frequency distribution. Such relatively low fecundity and frequency distributions of ovarian eggs suggest that Dolichopteryx species spawn iteratively during spawning season.  相似文献   

16.
17.
“Fire regime” has become, in recent decades, a key concept in many scientific domains. In spite of its wide spread use, the concept still lacks a clear and wide established definition. Many believe that it was first discussed in a famous report on national park management in the United States, and that it may be simply defined as a selection of a few measurable parameters that summarize the fire occurrence patterns in an area. This view has been uncritically perpetuated in the scientific community in the last decades. In this paper we attempt a historical reconstruction of the origin, the evolution and the current meaning of “fire regime” as a concept. Its roots go back to the 19th century in France and to the first half of the 20th century in French African colonies. The “fire regime” concept took time to evolve and pass from French into English usage and thus to the whole scientific community. This coincided with a paradigm shift in the early 1960s in the United States, where a favourable cultural, social and scientific climate led to the natural role of fires as a major disturbance in ecosystem dynamics becoming fully acknowledged. Today the concept of “fire regime” refers to a collection of several fire-related parameters that may be organized, assembled and used in different ways according to the needs of the users. A structure for the most relevant categories of parameters is proposed, aiming to contribute to a unified concept of “fire regime” that can reconcile the physical nature of fire with the socio-ecological context within which it occurs.  相似文献   

18.
This paper describes, analyzes, and critiques the construction of separate “male” and “female” genomes in current human genome research. Comparative genomic work on human sex differences conceives of the sexes as like different species, with different genomes. I argue that this construct is empirically unsound, distortive to research, and ethically questionable. I propose a conceptual model of biological sex that clarifies the distinction between species and sexes as genetic classes. The dynamic interdependence of the sexes makes them “dyadic kinds” that are not like species, which are “individual kinds.” The concept of sex as a “dyadic kind” may be fruitful as a remedy to the tendency to conceive of the sexes as distinct, binary classes in biological research on sex more generally.  相似文献   

19.
A new species, Dolichopteryx rostrata, is described on the basis of a single specimen (66.2 mm in standard length) collected west of the Hebrides Islands, eastern North Atlantic Ocean. The new species is characterized by an elongate snout and head, small pouchlike eyes, an adipose fin, short dorsal fin base, anal fin base originating under dorsal fin base, a clear longitudinal suborbital brownish band extending forward from behind posterior margin of orbit to snout tip, and 41 (=26 + 15) vertebrae. Total fecundity is low; the ovarian eggs number only 473, despite the ovary having developed ova. Ovarian eggs could be clearly subdivided into an “undeveloped group” (0.1–0.7 mm diameter classes, n = 405) and a “developed group” (0.9–1.3 mm classes, n = 68), based on their frequency distribution. Supplementary material to this paper is available in electronic format at http://dx.doi.org/10.1007/s10228-005-0306-2  相似文献   

20.
A new compact centrifugal blood pump driven by a miniature DC servomotor has been designed for use for short-term extra corporeal and cardiac-assisted circulation. The impeller of the pump was connected directly to the motor by using a simple-gear coupling. The shaft for the impeller was sealed from blood by both a V-ring and a seal bearing. Either pulsatile or nonpusatile flow was produced by controlling the current supply to the motor. The pump characteristics and the degree of hemolysis were evaluated with regard to the configuration of the impeller with a 38-mm outer diameter in vitro tests; the impeller having the blade angles at the inlet of 20 deg and at the outlet of 50 deg was the most appropriate as a blood pump. The performance in an operation, hemolysis and thrombus formation in the pump were assessed by a left ventricular bypass experiment in dogs. It was suggested by this study that this prototype pump appears promising for use not only in animal experiments but also in clinical application.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号