首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Circulating concentrations of mevalonic acid (MVA) change in parallel with, and may be used as a marker of cholesterol biosynthesis. Plasma MVA levels have been quantified using a sensitive and specific capillary gas chromatography-electron capture mass spectrometric assay. The detection limit for MVA in plasma is 100 pg/ml; the intra-assay variation is 5.11%; the inter-assay variation is 7.7%. Using this assay, the mean plasma MVA in 15 normolipidemic subjects was 2.37 +/- 1.2 ng/ml (range 0.41-5.31 ng/ml). Administration of 40 mg of simvastatin (an HMG-CoA reductase inhibitor) significantly accenutated the diurnal decrease in plasma MVA levels. This assay may be useful in investigating cholesterol synthesis rates in different dyslipidemias and individual responses of HMG-CoA reductase-inhibiting drugs.  相似文献   

2.
A simple procedure for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in human serum using headspace solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with electron capture detector (ECD). A 2(7-4) Plackett-Burman reduced factorial design for screening and a central composite design for optimizing the significant variables were applied. A 100 microm PDMS fiber, 3/5 headspace ratio (3 ml in 5 ml vial), 85 degrees C extraction temperature, 50 min extraction time, and 1 ml of acidic solution (pH 3) added to 1 ml of diluted serum (1:1) were chosen for the best response in HS extraction mode. The detection limits found were from 1 pg/ml (PCB 167) to 52 pg/ml (beta-HCH), the relative standard deviation for the procedure varied from 3% (PCB 52) to 12% (PCB 189) and the accuracy was checked by using validated solid-phase extraction (SPE) procedure. The method that avoids the use of clean-up steps and the hazardous solvents enabled reliable determinations of the OCPs and the PCBs except beta-HCH. The method was applied to the analysis of 33 human serum samples. The most abundant target compound was p-p'-DDE (range, 0.3-8.0 ng/ml; median value, 2.1 ng/ml). Among the PCBs the prevalent congeners were 138, 153 and 180.  相似文献   

3.
A simple method for determination of deoxynivalenol (DON) in cereal samples is described. DON was extracted with methanol, the solvent evaporated, and the residue redissolved with water. This extract was purified on immunoaffinity columns. DON was determined by HPLC with UV-detection. The limits of detection (LOD) and quantification (LOQ) were 10 and 50 μg/kg, respectively. Presented at the 25th Mykotoxin Workshop in Giessen, Germany, May 19–21, 2003  相似文献   

4.
Fast test systems fulfilling legislative specifications are required to determine mycotoxin contamination in unprocessed cerealse.g. at grain elevators, import and export terminals, or the milling and brewing industry to prevent contamination of food and feed. We describe the first tests of a novel fluorescence-based test for deoxynivalenol (DON), which will be commercially available within the next few months. The analytical procedure of the new test takes less than 15 minutes for extraction, purification, derivatization and measurement. The system’s advantage is its speed and easy procedure providing quantitative DON determination. To ensure an international standard, the validation procedure for wheat, barley and maize will be performed following USDA/GIPSA requirements (03/2006) for DON tests. Presented at the 28th Mykotoxin-Workshop, Bydgoszcz, Poland, May 29–31, 2006 Financial support: Christian Doppler Society and Government of Lower Austria  相似文献   

5.
In this paper, polychlorinated biphenyl (PCB), organochlorine pesticide (OCP) and pyrethroid pesticides in peach was investigated by comparing their residual level in peach juice, pulps and peels using dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) combined with gas chromatography-electron capture detection (GC-ECD). Extraction conditions such as the type of extractant, volume of extractant and dispersant, salt effect and extraction time were optimized. For juice samples, the linearity of the method was obtained in the range of 10-2000 ng L(-1),with determination coefficients>0.99. The limits of detection (LOD) of the method were ranged between 2.8 and 18.5 ng L(-1). For pulp and peel samples, the developed method is linear over the range assayed, 1-20 μg kg(-1),with coefficients also >0.99. The relative recoveries of compounds analyzed from juice, pulp and peel samples were in the range of 73-106% with a relative standard deviation between 2.6 and 11.8%. The proposed method was applied to the simultaneous analysis of residues in real peach juice, pulp and peel samples. As a result, there were no target analytes found in peach juices and pulps while 3.3 μg kg(-1) cyhalothrin and 3.5 μg kg(-1) fenvalerate were found in peels. The experiment results revealed that the pyrethroid residues just deposited on the peels of the fruits, but did not move into pulps and juices.  相似文献   

6.
Two separate analytical methods have been developed for the determination of butorphanol and its metabolites in human plasma. One method is specific for butorphanol (I) while the other determines the metabolites, hydroxybutorphanol (II) and norbutorphanol (III). Both procedures incorporate solid-phase extraction, chemical derivatization and separation, and detection using gas chromatography-electron-capture negative-ion chemical ionization mass spectrometry (GC-ECNCI-MS). Both methods use the cyclopropyl analog of I (BC-2605, IV) as the internal standard and the procedures for extraction of the analytes from plasma are identical. However, following extraction, either the pentafluorobenzoyl ester of I or the tris- and bis-trifluoroacetyl esters of II and III, respectively, were prepared. The derivatives were analyzed by GC-ECNCI-MS with selected-ion monitoring of the molecular ions. The standard curves were linear over the concentration ranges of 20–2000, 20–1000 and 50–1000 pg/ml for I, II and III, respectively. All standard curves from the assay validation had r2 values of ≥0.994, 0.991 and 0.985 for I, II and III, respectively. For all three compounds, the intra- and inter-assay precisions (CV) and inter-assay accuracy (deviation from nominal) were within 12% for plasma quality control samples. All derivatives were stable in the reconstitution solvent for at least 24 h. The assays are being used for the determination of plasma concentrations of I, II and III in humans following repeated administration of nasal spray.  相似文献   

7.
A rapid, sensitive, and reproducible method was developed for quantitative determination of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and its biodegradation intermediates, hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX), hexahydro-1,3-dinitroso-5-nitro-1,3,5-triazine (DNX), and hexahydro-1,3,5-trinitroso-1,3,5-triazine (TNX) in soils. RDX, MNX, DNX, or TNX was extracted from soil by pressurized liquid extraction (PLE), followed by cleanup using florisil. Instrumental analysis was performed using gas chromatography with electron capture detection (GC-ECD), which was highly sensitive to the parent explosive and its metabolites. The method detection limits (MDLs) were 0.243, 0.095, 0.138, and 0.057 ng/g for RDX, MNX, DNX, and TNX, respectively. The method gave high recovery (98-102%), good precision (0.22-5.14%), and reproducibility, and proved to be suitable for real world sample analysis.  相似文献   

8.
A simple, rapid, sensitive and reproducible method based on solid-phase extraction (SPE) and acidified silica clean-up was developed for the measurement of 12 polybrominated diphenyl ethers (PBDEs), including BDE 209, and 2,2',4,4',5,5'-hexabromobiphenyl (BB 153) in human serum. Several solid-phase sorbents (Empore C(18), Isolute Phenyl, Isolute ENV+ and OASIS HLB) were tested and it was found that OASIStrade mark HLB (500 mg) gives the highest absolute recoveries (between 64% and 95%, R.S.D.<17%, n=3) for all tested analytes and internal standards. Removal of co-extracted biogenic materials was performed using a 6 ml disposable cartridge containing (from bottom to top) silica impregnated with sulphuric acid, activated silica and anhydrous sodium sulphate. PBDEs and BB 153 were quantified using a gas chromatograph coupled with a mass spectrometer (MS) operated in electron-capture negative ionization mode. The method limits of quantification (LOQ) ranged between 0.2 and 25 pg/ml serum (0.1 and 4 ng/g lipid weight). LOQs were dependent on the analyte levels in procedural blanks which resulted in the highest LOQs for PBDE congeners found in higher concentrations in blanks (e.g. BDE 47, 99 and 209). The use of OASIS HLB SPE cartridge allowed a good method repeatability (within- and between-day precision<12% for all congeners, except for BDE 209<17%, n=3). The method was applied to serum samples from a random Belgian population. The obtained results were within the range of PBDE levels in other non-exposed population from Europe.  相似文献   

9.
The sources of variation In the analysis of trichothecenes in cereals by gas chromatography mass spectrometry (GC-MS) were studied and Identified. Ways to decrease some of the variations identified are presented and discussed. The method Is validated for deoxynivalenol, nivalenol, 3-acetyldeoxynivalenol, fusarenon-X, diacetoxyscirpenol, HT-2 toxin and T-2 toxin. The general variability in the performance of the GC-MS apparatus itself, as well as derivatisation, matrix effect, injection and quantification were identified to be the sources of variation. The use of internal standards was studied in order to decrease the variation due to problems with derivatisation and the overall sample preparation. Two derivatisation reagents were compared, one of which was found to be more effective for decreasing this variation. The calibrants prepared in the cereal extract reduced the variation due to the matrix effect and thus improved the quantification. “Constant Standards” were introduced in order to detect and decrease the variation caused by injection and the apparatus itself. The validation study proved that this analytical method for trichothecenes was adequately reliable and sensitive. The relative standard deviation varied between 3–9% and the recovery between 46–90% for the different trichothecenes determined. The limit of detection for a range of trichothecenes varied from 5 μg/kg to 15 μg/kg.  相似文献   

10.
11.
A method for isolating climax products of the arachidonic acid cascade from biological fluids is described which allows simultaneous measurement of PGs (PGE2, PGD2, 6-keto-PGF1 alpha, TXB2, 6-keto-PGE1, 6, 15-diketo-13,14-dihydro-PGF1 alpha) by electron capture detection of pentafluorobenzyloxime methyl ester trimethylsilyl (TMS) ether derivatives. PGs are adsorbed onto Amberlite XAD-2 from acidified solution and nonadhering substances removed by sequential administration of water, then petroleum ether. PGs are extracted into methanol. Following evaporation and reconstitution in water, the PGs are extracted into ethyl acetate at pH 3 and the ethyl acetate extracts are purified by lipidex column chromatography. Derivatization to pentafluorobenzyloxime methyl ester TMS ethers of PGs in the sample is followed by separation on either glass packed-columns or SCOT capillary columns, and detection by an electron capture detector. PGA2, added to the unpurified sample, is used as an internal standard for quantification. The methods have performed well on all biological fluids thus far examined. Examples of chromatographs from urine, Krebs-perfused lung effluents, and blood are shown.  相似文献   

12.
An assay was developed for the quantification of anastrozole [2,2′-[5-(1H-1,2,4-triazol-1-ymethyl)-1,3-phenylene]bis(2-methylpropiononitrile)] in human plasma using liquid-liquid extraction. Anastrozole and an internal standard were chromatographed and detected by gas chromatography with electron capture detection, using a combination temperature-pressure program. The range of the assay is 3 to 100 ng/ml. Anastrozole was quantified by comparing its peak area to that of an internal standard. A cross-validation of this assay was also successfully performed between several laboratories.  相似文献   

13.
4-Hydroxy-2-nonenal (HNE) has been prepared from the corresponding dimethylacetal (HNE-DMA), in turn synthesized by a conventional approach with a few modifications of the experimental protocol and some improvements in the purification of the final product. In order to exploit the sensitivity of gas-chromatography with electron capture detector (GC-ECD) in the analysis of HNE derivatives, reaction of HNE with 2,4,6-trichlophenylhydrazine (TCPH) and 3,5-dichloro-phenylhydrazine (DCPH) was tested. Reaction with TCPH afforded a mixture of products, whereas with DCPH a single major product was formed that was prepared on a millimolar scale and purified. (1)H-NMR analysis established that the derivative of HNE with DCPH is HNE 3,6-dichloro-phenylhydrazone, that can be used as standard for GC-ECD analysis.  相似文献   

14.
A Fusarium and Fusarium toxin monitoring programme has been established within the food and feed control authorities of Saxony-Anhalt for the 2001–2003 period. The first results of the deoxynivalenol analyses of cereals and cereal products with assured origin in this federal state, showed a contamination rate of 42% for wheat and wheat products. The contamination incidence reached only 14% in rye and rye products. Zearalenone couldn't be detected at all in the analyzed samples.  相似文献   

15.
16.
An electron capture gas chromatographic method is described for the detection of thromboxane B2. Thromboxane B2 is esterified with diazomethane, followed by treatment with pentafluorobenzylhydroxylamine hydrochloride and silylation with BSA. In pyridine, the free aldehyde form of the acetal ring is favored allowing rapid formation of a novel thromboxane B2 pentafluorobenzyloxime. The method has been applied to detect thromboxane B2 formation during aggregation of washed platelets. It must be emphasized that by ordinary analytical standards, the derivatization reproducibility from 50–375 nanograms is poor (±11% – ±42%); however, the improved selectivity of the method and its ability to detect nanogram levels of thromboxane B2 make it a useful complement to commonly employed bioassay techniques.  相似文献   

17.
A form-function analysis of photon capture for seaweeds   总被引:3,自引:2,他引:1  
Ramus  J. 《Hydrobiologia》1990,199(1):65-71
A large material of planktonic and semiplanktonic micro-crustaceans from various type of waters in south and central Sweden was computerized. The more frequent species were listed according to pH-preference and relation to humic content measured as mg Pt/l. Species indicating oligotrophy have their optima just below the neutral point, eurytopic ones around this level, while the eutrophic species Daphnia cucullata and D. magna were closely correlated with higher pH-levels. No really extreme pH-preference was observed. There is no link between trophic indication and the ranking list for humic content. Most planktic species occur at lower humic contents and semiplankters at higher.  相似文献   

18.
Threonine was oxidized into acetaldehyde at 0 degrees C for 30 min with periodic acid. The acetaldehyde formed was converted to a hydrazone with 2,4-dinitrophenyhydrazine. The hydrazone was extracted with n-heptane and quantified by gas liquid chromatography with electron capture detection. An internal standard, 2-amino-3-hydroxyhexanoic acid, was used. The calibration curve of threonine was linear up to 200 nmol in 200 microl sample solution and the determination limit of threonine was 1 nmol in 200 microl sample solution. The recoveries were 100.0, 94.0 and 100.0% from homogenates of octopus tentacles and blood plasma and rat livers, respectively. This method was applied to the determination of threonine in tissues of rats given threonine and starved octopuses. This threonine determination method has been used for studies on the metabolism of d-lactate.  相似文献   

19.
An immunoaffinity column (IAC) was prepared with a new deoxynivalenol (DON) monoclonal antibody and used as a clean-up tool before ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) analysis of DON in cereals. The developed IAC clean-up method showed high recoveries for DON. They ranged from 61% to 103% in wheat, rice, and millet with intra-day and inter-day variations below 19% and 17%, respectively. The column capacity was 2.86μg DON per mL of gel, and it maintained above 0.68μg/mL of gel after 10 cycles of usage at 2 days intervals. The limit of detection (LOD) and limit of quantification (LOQ) were 0.3 and 0.8μg/kg, respectively. Twenty-one out of 40 analyzed commercial cereal samples were positive at DON concentrations from 7 to 534μg/kg.  相似文献   

20.
Abstract A new capture test utilizing conjugated peptides has been developed for the detection of antibodies elicited against HIV-1. Human sera diluted 1:1000 were incubated in ELISA plates precoated with protein G. The captured IgG were allowed to react with three synthetic peptides corresponding to the gp41 sequence (591–611) YLKDQQLLGIWGCSGKLICTT, the gp120 sequence (314–329) IRIQRGPGRAFVTIGK and the p27 sequence (182–198) EWRFDSRLAFHHVAREL. The peptides were used in the form of N -hydroxysuccinimido-biotin ovalbumin conjugates. Peroxidase-labelled streptavidin was used to detect antigen-antibody complexes. The sensitivity and specificity of detection of antibodies were analyzed with 40 HIV positive sera, 10 seroconverting sera and 21 normal human sera (NHS). The results were compared with a commercial indirect ELISA in which a single conjugated gp41 peptide was used as antigenic probe. This indirect ELISA recognized 100% of the HIV positive and the seroconverting sera. The new capture test using the gp41 conjugated peptide also recognized 100% of the HIV positive sera but was more specific since it gave no false positive results whereas the indirect test did. The gp120 and p27 conjugated peptides detected 35/40 (87.5%) and 31/40 (77.5%) of HIV positive sera respectively and also detected 9/10 (90%) and 10/10 (100%) of the seroconverting sera respectively, without any false positive results (0/21). The proposed new capture test is a very sensitive and specific assay for detecting HIV antibodies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号