首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to determine the influence of patellofemoral joint contact geometry on the modeling of three-dimensional patellofemoral joint forces. To achieve this goal, patellofemoral joint reaction forces (PFJRFs) that were measured from an in-vitro cadaveric set-up were compared to PFJRFs estimated from a computer model that did not consider patellofemoral joint contact geometry. Ten cadaver knees were used in this study. Each was mounted on a custom jig that was fixed to an Instron frame. Quadriceps muscle loads were accomplished using a pulley system and weights. The force in the patellar ligament was obtained using a buckle transducer. To quantify the magnitude and direction of the PFJRF, a six-axis load cell was incorporated into the femoral fixation system so that a rigid body assumption could be made. PFJRF data were obtained at 0 degrees , 20 degrees , 40 degrees and 60 degrees of knee flexion. Following in vitro testing, SIMM modeling software was used to develop computational models based on the three-dimensional coordinates (Microscribe digitizer) of individual muscle and patellar ligament force vectors obtained from the cadaver knees. The overall magnitude of the PFJRF estimated from the computer generated models closely matched the direct measurements from the in vitro set-up (Pearson's correlation coefficient, R(2)=0.91, p<0.001). Although the computational model accurately estimated the posteriorly directed forces acting on the joint, some discrepancies were noted in the forces acting in the superior and lateral directions. These differences however, were relatively small when expressed as a total of the overall PFJRF magnitude.  相似文献   

2.
Human teeth with substantial coronal defects are subject to reconstruction by means of post and core restorations. Typically, such a restoration comprises a slightly cylindrical post onto which an abutment of varying shape, depending on the designated restoration, is attached. As clinical results are not satisfactory to date, we proposed a new proprietary post and core design which makes use of positive locking. As this prefabricated system is not customised to an individual root's cross-sectional geometry (usually oval), a varying amount of radicular dentin is left in periphery of the core's outer edge. The aim of this study was to assess the implications of this fact, i.e., whether the root has to endure higher overall stress levels which ultimately may lead to failure of one of the components involved. A series of finite element simulations were performed to evaluate stress and strain on the system, in which the proposed post and core was embedded into a virtual dentin cylinder of different diameters, ranging from flush mounting of the restoration to a dentin excess of 4 mm, and subsequently loaded with forces with two angles of attack (90 degrees and 130 degrees ). The results show that flush mounting yields an agreeable stress and strain distribution within the radicular dentin, but overall stress levels drop significantly with an excess of 0.5 mm of surrounding dentin. More than 1 mm excess was not found to have profound positive effects.  相似文献   

3.
One method to determine the forces produced during running is to conduct extensive kinematic and kinetic analysis. These analyses can be performed by having an individual perform repeated over-ground running trials or simply run continuously on an instrumented treadmill. The forces produced during over-ground running may not be the same as the forces during treadmill running and these differences could be attributed to a number of factors, including the design of the instrumented treadmill. The purpose of this paper was to determine whether there are differences in force measurements on different instrumented treadmill setups in comparison to over-ground running and to correct for any of these differences using a theoretical model. 11 participants ran on three different treadmills and performed over-ground running at 2.7, 3.6, and 4.5 m/s. Ground reaction forces were measured via force plates and an instrumented pressure insole. We found that the magnitude of the vertical ground reaction force differed between the three treadmills and over-ground running. The difference in ground reaction forces estimated by the pressure insole and the treadmill-force-plate system or instrumented treadmill can be explained by a three degree of freedom mechanical model of a person running on a treadmill and this model could potentially be used to correct for errors in force measurement from instrumented treadmills. The model included a force plate, a treadmill, and a wobbling mass with varying natural frequencies and damping characteristics, and constant masses. These findings provide researchers a method to correct forces from an instrumented treadmill set-up to determine a close approximation of the actual forces experienced by a participant during treadmill running.  相似文献   

4.
Many studies have investigated the effect of different parameters of the endodontically restored tooth on its final strength, using in vitro tests and model simulations. However, the differences in the experimental set-up or modelling conditions and the limited number of parameters studied in each case prevent us from obtaining clear conclusions about the relative importance of each parameter. In this study, a validated 3D biomechanical model of the restored tooth was used for an exhaustive sensitivity analysis. The individual influence of 20 different parameters on the mechanical performance of an endodontic restoration with prefabricated posts was studied. The results bring up the remarkable importance of the loading angle on the final restoration strength. Flexural loads are more critical than compressive or tensile loads. Young's modulus of the post and its length and diameter are the most influential parameters for strength, whereas other parameters such as ferrule geometry or core and crown characteristics are less significant.  相似文献   

5.
Many previous studies, both in vitro and with model simulations, have been conducted in an attempt to reach a full understanding of how the different design parameters of an endodontically restored tooth affect its mechanical strength. However, differences in the experimental set-up or modelling conditions and the limited number of parameters studied in each case prevent us from obtaining clear conclusions about the real significance of each parameter. In this work, a new approach is proposed for this purpose based on the combination of a validated three-dimensional parametric biomechanical model of the restored tooth and statistical analysis using full factorial analysis of variance. A two-step approach with two virtual tests (with, respectively, 128 and 81 finite element models) was used in the present work to study the effect of several design parameters on the strength of a restored incisor, using full factorial designs. Within the limitations of this study, and for cases where the parameters are within the ranges that were tested, the conclusions indicate that the material of the post is the most significant factor as far as its strength is concerned, the use of a low Young's modulus being preferable for this component. Once the post material has been chosen, the geometry of the post is of less importance than the Young's modulus selected for the core or, especially, for the crown.  相似文献   

6.
Registering substrate reaction forces from primates during climbing requires the design and construction of customized recording devices. The technical difficulties in constructing a reliable apparatus hinder research on the kinetics of primate locomotion. This is unfortunate since arboreal locomotion, especially vertical climbing, is an important component of the hominoid locomotor repertoire. In this technical paper, we describe a custom-built climbing pole that allows recordings of dynamic 3-dimensional forces during locomotion on horizontal and sloping substrates and during vertical climbing. The pole contains an instrumented section that can readily be modified and enables us to register forces of a single limb or multiple limbs in a broad range of primates. For verification, we constructed a similar set-up (which would not be usable for primates) using a conventional force plate. Data for a human subject walking on both set-ups were compared. The experimental set-up records accurate and reliable substrate reaction forces in three orthogonal directions. Because of its adjustability, this type of modular set-up can be used for a great variety of primate studies. When combining such kinetic measurements together with kinematic information, data of great biomechanical value can be generated. These data will hopefully allow biological anthropologists to answer current questions about primate behaviours on vertical substrates.  相似文献   

7.
Air assistance on field sprayers creates a forced airstream under the spray boom which blows the spray droplets into the crop. The advantages of this relative new technique are less drift of spray droplets and the possibility to reduce the amount of pesticides and spray Liquid. The purpose of this work was to investigate the effect of air assistance on the characteristics of spray droplets and their driftability. Based on air velocity measurements on an air assisted field sprayer, a system of air assistance was developed in addition to a laser-based measuring set-up for the characterisation of spray droplets. With this set-up, the effect of air support on the droplet characteristics was investigated for different settings of the air assistance. The effect on spray drift was quantified based on field drift measurements. A reducing effect on the total amount of spray drift was demonstrated for the Hardi ISO F 110 02, F 110 03 and LD 110 02 nozzles with drift reduction factors a(d) of, respectively, 2.08, 1.77 and 1.53. The use of air support had no significant effect for the LD 110 03 nozzles on the total amount of spray drift. Comparing droplet size and drift results, it was found that air support has the highest impact on the amount of spray drift for the finer sprays by increasing droplet velocities. The effect of air support on droplet sizes is rather limited.  相似文献   

8.
In dynamic force spectroscopy, access to the characteristic parameters of single molecular bonds requires nontrivial measurements and data processing as the rupture forces are found not only to be distributed over a wide range, but are also dependent on the loading rate. The choice of measurement procedure and data processing methods has a considerable impact on the accuracy and precision of the final results. We analyze, by means of numerical simulations, methods to minimize and assess the magnitude of the expected errors for different combinations of experimental and evaluation methods. It was found that the choice of fitting function is crucial to extract correct parameter values. Applying a Gaussian function, which is a common practice, is equivalent to introducing a systematic error, and leads to a consequent overestimation of the thermal off-rate by more than 30%. We found that the precision of the bond length and the thermal off-rate, in presence of unbiased noise, were improved by reducing the number of loading rates for a given number of measurements. Finally, the results suggest that the minimum number of measurements needed to obtain the bond strength, with acceptable precision, exceeds the common number of ~100 reported in literature.  相似文献   

9.
There are different opinions in the literature on whether the cost functions: the sum of muscle stresses squared and the sum of muscle stresses cubed, can reasonably predict muscle forces in humans. One potential reason for the discrepancy in the results could be that different authors use different sets of model parameters which could substantially affect forces predicted by optimization-based models. In this study, the sensitivity of the optimal solution obtained by minimizing the above cost functions for a planar three degrees-of-freedom (DOF) model of the leg with nine muscles was investigated analytically for the quadratic function and numerically for the cubic function. Analytical results revealed that, generally, the non-zero optimal force of each muscle depends in a very complex non-linear way on moments at all three joints and moment arms and physiological cross-sectional areas (PCSAs) of all muscles. Deviations of the model parameters (moment arms and PCSAs) from their nominal values within a physiologically feasible range affected not only the magnitude of the forces predicted by both criteria, but also the number of non-zero forces in the optimal solution and the combination of muscles with non-zero predicted forces. Muscle force magnitudes calculated by both criteria were similar. They could change several times as model parameters changed, whereas patterns of muscle forces were typically not as sensitive. It is concluded that different opinions in the literature about the behavior of optimization-based models can be potentially explained by differences in employed model parameters.  相似文献   

10.
为探究EwE(Ecopath with Ecosim)模型的历史演变和应用现状,本文通过Web of Science主题检索和引文链接法获得1984—2020年间的研究文献构成核心数据集和扩展数据集,并以此为数据源,从论文分布、研究力量、研究主题、热点演化等方面进行科学文献计量分析,利用CiteSpace软件绘制相关图谱。结果表明: EwE模型的系列研究成果产出总体呈上升态势,且广泛分布于多学科交叉领域, Christensen、Walters、Pauly等学者在模型应用和国际合作中起到重要推动作用。过去,EwE模型通过建立功能组间的营养关系,主要用于解决生态系统结构和功能的时空变化、捕捞对生态系统影响等问题。当前,研究主题聚焦于海洋资源管理、生态系统模拟、海洋保护区、生态系统指标等重点群组。研究热点从模型开发和食物网结构向生态系统预测和资源管理研究演变,从而为基于生态系统的水域资源管理和海洋保护区建设等提供科学依据。  相似文献   

11.
Knowledge of the interaction of forces between persons and the bed in which they lie or the seat on which they are sitting, provides an insight into the loading of their muscles, bones and soft tissue. To determine the total forces on the body-supporting surfaces (backrest, seat pan, foot rest) resolved in components perpendicular and parallel to these surfaces a new instrument has been developed, with which the forces perpendicular and parallel to three different freely adjustable body-supporting surfaces can be registered. During the first measurements the forces on a bed were measured when a person sits in a bed with the backrest at an angle of 45° to the horizontal and the mattress horizontal. The measurements on a healthy population (mean mass = 77 kg, sd = 11 kg) showed an accuracy of ± 10 N. In this position the mean shear force on the seat pan was 97 N.  相似文献   

12.
13.
Morphogenesis, the process by which all complex biological structures are formed, is driven by an intricate interplay between genes, growth, as well as intra- and intercellular forces. While the expression of different genes changes the mechanical properties and shapes of cells, growth exerts forces in response to which tissues, organs and more complex structures are shaped. This is exemplified by a number of recent findings for instance in meristem formation in Arabidopsis and tracheal tube formation in Drosophila. However, growth not only generates forces, mechanical forces can also have an effect on growth rates, as is seen in mammalian tissues or bone growth. In fact, mechanical forces can influence the expression levels of patterning genes, allowing control of morphogenesis via mechanical feedback. In order to study the connections between mechanical stress, growth control and morphogenesis, information about the distribution of stress in a tissue is invaluable. Here, we applied stress-birefringence to the wing imaginal disc of Drosophila melanogaster, a commonly used model system for organ growth and patterning, in order to assess the stress distribution present in this tissue. For this purpose, stress-related differences in retardance are measured using a custom-built optical set-up. Applying this method, we found that the stresses are inhomogeneously distributed in the wing disc, with maximum compression in the centre of the wing pouch. This compression increases with wing disc size, showing that mechanical forces vary with the age of the tissue. These results are discussed in light of recent models proposing mechanical regulation of wing disc growth.  相似文献   

14.
A new approach to estimate normal and tangential contact parameters in the foot-ground contact during human gait was proposed. A correct estimation of the contact parameters would be very important in the resolution of predictive forward dynamic problems. The normal contact forces have been well estimated in the literature. But accurate estimation of tangential forces has not been reached yet. This work proposed a new procedure to accurately estimate friction forces. The approach has been based on the consideration of the modulus of the tangential force instead of its components. This modulus was introduced together with the modulus of the normal contact force and its two associated moments in an optimization algorithm to fit the contact forces provided by the model to the experimental data obtained with a force plate. An inverse dynamics problem was solved as a step previous to the optimization algorithm. The results showed that both the normal and tangential forces and the moments in the horizontal plane were in agreement with the experimental measurements. This work also analyzed the influence on the results of the friction law. The results obtained with the general friction law, which considered dry (static and dynamic) and viscous friction, were compared with results provided by simpler laws. The analysis of the components of the friction forces pointed out the importance of the Stribeck component in the resultant force instead of the viscous friction which played a minimal role. But for modelling the stick-slip transition, the implementation of a general friction law is necessary.  相似文献   

15.
Phospholipid bilayers were formed on mica using the Langmuir–Blodgett technique and liposome fusion, as a model system for biomembranes. Nanometer-scale surface physical properties of the bilayers were quantitatively characterized upon the different phases of the first leaflets. Lower hydration/steric forces on the bilayers were observed at the liquid phase of the first leaflet than at the solid phase. The forces appear to be related to the low mechanical stability of the lipid bilayer, which was affected by the first leaflet phase. The first leaflet phase also influenced the long-range repulsive forces over the second leaflet. Surface forces, measured using a modified probe with an atomic force microscope, showed that lower long-range repulsive forces were also found at the liquid phase of the first leaflet. Force measurements were performed at 300 mM sodium chloride solution so that the effect of the phase on the long-range repulsive forces could be investigated by reducing the effect of the repulsion between the second-leaflet lipid headgroups on the long-range repulsive forces. Forces were analyzed using the Derjaguin–Landau–Verwey–Overbeek theory so that the surface potential and surface charge density of the lipid bilayers were quantitatively acquired for each phase of the first leaflet.  相似文献   

16.
Substrate removal mechanism in aerobic activated sludge processes was lately modeled using the simultaneous storage and growth (SSAG) phenomenon. The SSAG model was further refined with titrimetric components and successfully calibrated using both respirometric and titrimetric measurements for common substrate acetate. However, the improved SSAG model calibration was not verified with other organic substrates. Furthermore, very few studies are available in the literature on surfactant bio-kinetics, which generally use off-line experimental measurements with limited model-based interpretation. Therefore, the aim of this paper is to demonstrate its applicability for surfactant biodegradation using on-line measurements. Batch experiments were conducted using sodium dodecyl sulfate (SDS) as a test surfactant. Model calibration was done successfully for three different SDS concentrations using respirometric, titrimetric and combined respirometric-titrimetric measurement approaches. The parameter estimation results from all three stated combinations were statistically evaluated and found to be very close validating the model.  相似文献   

17.
18.
It is postulated that there is a causal relationship between mechanical stimulus and the rate of bone healing post fracture. However, despite numerous experimental studies in the literature, no quantifiable relationship has been proposed. It is hypothesized in the present study that the temporal rate of bone fracture healing, measured in terms of callus stiffening per week, can be described mathematically based on the relative motions between bone fragments at the initial stage of the healing process. To test this, a comparative reanalysis of experimental data found in the literature was conducted. These individual data sets described a relationship between an initial intermittently applied peak interfragmentary strain and the change in interfragmentary motion or the increase in callus stiffness over time. The data were converted into a relative increase in stiffness, which normalised the results and reduced inter-study variability. The rates of healing for the various initial strains were compared, and based on this a mathematical phenomenological model was derived. Error analyses were then performed, which showed a high level of congruence between the in-vivo and simulated rates of healing. The results of the comparative analysis revealed that there is a positive correlation between the rate of callus stiffening and interfragmentary strain. Finally, the proposed model has shown for the first time that a quantifiable cause–and–effect relationship exists between the rate of bone healing and mechanical stimulus.  相似文献   

19.

Accurate estimation of mechanical properties of the different atherosclerotic plaque constituents is important in assessing plaque rupture risk. The aim of this study was to develop an experimental set-up to assess material properties of vascular tissue, while applying physiological loading and being able to capture heterogeneity. To do so, a ring-inflation experimental set-up was developed in which a transverse slice of an artery was loaded in the radial direction, while the displacement was estimated from images recorded by a high-speed video camera. The performance of the set-up was evaluated using seven rubber samples and validated with uniaxial tensile tests. For four healthy porcine carotid arteries, material properties were estimated using ultrasound strain imaging in whole-vessel-inflation experiments and compared to the properties estimated with the ring-inflation experiment. A 1D axisymmetric finite element model was used to estimate the material parameters from the measured pressures and diameters, using a neo-Hookean and Holzapfel–Gasser–Ogden material model for the rubber and porcine samples, respectively. Reproducible results were obtained with the ring-inflation experiment for both rubber and porcine samples. Similar mean stiffness values were found in the ring-inflation and tensile tests for the rubber samples as 202 kPa and 206 kPa, respectively. Comparable results were obtained in vessel-inflation experiments using ultrasound and the proposed ring-inflation experiment. This inflation set-up is suitable for the assessment of material properties of healthy vascular tissue in vitro. It could also be used as part of a method for the assessment of heterogeneous material properties, such as in atherosclerotic plaques.

  相似文献   

20.
Simplified loading modes (pure moment, compressive force) are usually applied in the in vitro studies to simulate flexion-extension, lateral bending and axial rotation of the spine. The load magnitudes for axial rotation vary strongly in the literature. Therefore, the results of current investigations, e.g. intervertebral rotations, are hardly comparable and may involve unrealistic values. Thus, the question 'which in vitro applicable loading mode is the most realistic' remains open. A validated finite element model of the lumbar spine was employed in two sensitivity studies to estimate the ranges of results due to published load assumptions and to determine the input parameters (e.g. torsional moment), which mostly affect the spinal load and kinematics during axial rotation. In a subsequent optimisation study, the in vitro applicable loading mode was determined, which delivers results that fit best with available in vivo measurements. The calculated results varied widely for loads used in the literature with potential high deviations from in vivo measured values. The intradiscal pressure is mainly affected by the magnitude of the compressive force, while the torsional moment influences mainly the intervertebral rotations and facet joint forces. The best agreement with results measured in vivo were found for a compressive follower force of 720N and a pure moment of 5.5Nm applied to the unconstrained vertebra L1. The results reveal that in many studies the assumed loads do not realistically simulate axial rotation. The in vitro applicable simplified loads cannot perfectly mimic the in vivo situation. However, the optimised values lead to the best agreement with in vivo measured values. Their consequent application would lead to a better comparability of different investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号