首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 microl) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3-->255.3). The assay was linear from 0.2 to 25 microg/l (r(2)>0.997, n=5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 microg/l) were 95.8-103.2 and <5.5%, respectively. At the lower limit of quantification (0.2 microg/l) the inter- and intra-day analytical recovery was 99.0-102.8% with imprecision of <7.6% (n=5). The assay had a mean relative recovery of 100.5+/-5.8% (n=15). Extracted samples were stable for 16 h. FTY720 quality control samples were stable at room temperature for 16 h, at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans.  相似文献   

2.
We report here a validated method for the quantification of a new immunosuppressant drug, everolimus (SDZ RAD), using HPLC-tandem mass spectrometry. Whole blood samples (500 microl) were prepared by protein precipitation, followed by C(18) solid-phase extraction. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface operating in positive ionization mode. The assay was linear from 0.5 to 100 microg/l (r(2) > 0.996, n = 9). The analytical recovery and inter-day imprecision, determined using whole blood quality control samples (n = 5) at 0.5, 1.2, 20.0, and 75.0 microg/l, was 100.3 - 105.4% and < or = 7.6%, respectively. The assay had a mean relative recovery of 94.8 +/- 3.8%. Extracted samples were stable for up to 24 h. Fortified everolimus blood samples were stable at -80 degrees C for at least 8 months and everolimus was found to be stable in blood when taken through at least three freeze-thaw cycles. The reported method provides accurate, precise and specific measurement of everolimus in blood over a wide analytical range and is currently supporting phase II and III clinical trials.  相似文献   

3.
A method for the quantification of 2′-deoxy-3′-thiacytidine (lamivudine, 3-TC), which incorporated the use of 3-isobutyl-methylxanthine as internal standard (I.S.) was developed and validated in human plasma, using HPLC with UV absorbance detection. Using solid-phase extraction, 3-TC and I.S. were selectively extracted from human plasma. Subsequently, chromatographic separation was performed using a YMC phenyl column with ion-pair chromatography and detection at 270 nm. The method was validated over a concentration range of 10 to 5000 ng/ml using 0.5 ml of human plasma. The extraction recovery for both 3-TC and I.S. was greater than 95%. The determination of inter- and intra-day precision (RSD) was less than 10% at all concentration levels, while the inter- and intra-day accuracy (% difference) was less than 6%.  相似文献   

4.
Indomethacin (IND) is the drug of choice for the closure of a patent ductus arteriosus (PDA) in neonates. This paper describes a simple, sensitive, accurate and precise microscale HPLC method suitable for the analysis of IND in plasma of premature neonates. Samples were prepared by plasma protein precipitation with acetonitrile containing the methyl ester of IND as the internal standard (IS). Chromatography was performed on a Hypersil C(18) column. The mobile phase of methanol, water and orthophosphoric acid (70:29.5:0.5, v/v, respectively), was delivered at 1.5 mL/min and monitored at 270 nm. IND and the IS were eluted at 2.9 and 4.3 min, respectively. Calibrations were linear (r>0.999) from 25 to 2500 microg/L. The inter- and intra-day assay imprecision was less than 4.3 % at 400-2000 microg/L, and less than 22.1% at 35 microg/L. Inaccuracy ranged from -6.0% to +1.0% from 35 to 2000 microg/L. The absolute recovery of IND over this range was 93.0-113.3%. The IS was stable for at least 36 h when added to plasma at ambient temperature. This method is suitable for pharmacokinetic studies of IND and has potential for monitoring therapy in infants with PDA when a target therapeutic range for IND has been validated.  相似文献   

5.
An analytical method for simultaneous determination of benazepril and its active metabolite, benazeprilat, in human plasma by high-performance liquid chromatography/electrospray-mass spectrometry was developed and validated. Rutaecarpine was selected as the internal standard. The separation was achieved on a C(18) column with acetonitrile and aqueous solution (0.1% formic acid) as mobile phase with a gradient mode. The quantification of target compounds was using a selective ionization recording at m/z 425.5 for benazepril, m/z 397.5 for benzeprilat and m/z 288.3 for rutaecarpine. The correlation coefficients of the calibration curves were better than 0.992 (n = 6), in the range of 6.67-666.67 ng/ml for benazepril and benazeprilat. The inter- and intra-day accuracy, precision, linear range had been investigated in detail. The method can be used to assess the bioavailability and pharmacokinetics of the drug.  相似文献   

6.
The immunosuppressant drug mycophenolic acid (MPA) and its major metabolite, mycophenolic acid glucuronide (MPAG), are highly bound to albumin. An HPLC-tandem-MS (HPLC/MS/MS) and an HPLC-UV assay were developed to measure free (unbound) concentrations of MPA and MPAG, respectively. Ultrafiltrate was prepared from plasma (500 microl) by ultrafiltration at 3000 x g for 20 min (20 degrees C). Both MPA and MPAG were isolated from ultrafiltrate (100 microl) by acidification and C18 solid-phase extraction. Free MPA was measured by electrospray tandem mass spectrometry using selected reactant monitoring (MPA: m/z 338.2--> 206.9) in positive ionisation mode. Chromatography was performed on a PFPP column (50 mm x 2 mm, 5 microm). Total analysis time was 7 min. The assay was linear over the range 1-200 microg/l with a limit of quantification of 1 microg/l. The inter-day accuracy and imprecision of quality controls (7.5, 40, 150 microg/l) were 94-99% and < 7%, respectively. Free MPAG was chromatographed on a C18 Nova-Pak column (150 mm x 3.9 mm, 5 microm) using a binary gradient over 20 min. The eluent was monitored at 254 nm. The assay was linear over the range 1-50 mg/l with the limit of quantification at 2.5 mg/l. The inter-day accuracy and imprecision of quality controls (5, 20, 45 mg/l) was 101-107% and < 8% (n = 4), respectively. For both methods no interfering substances were found in ultrafiltrate from patients not receiving MPA. The methods described have a suitable dynamic linear range to facilitate the investigation of free MPA and MPAG pharmacokinetics in transplant patients. Further, this is the first reported HPLC-UV method to determine free MPAG concentrations.  相似文献   

7.
A stereoselective liquid chromatography-tandem mass spectrometry assay was developed and validated for quantification of S- and R-metoprolol at concentrations of 0.5-50 microg/L in human plasma. Metoprolol was extracted from plasma by liquid-liquid extraction with ethyl acetate (82% recovery). Chromatographic separation of the enantiomers was achieved on a chiral Chirobiotic T column using an isocratic mobile phase consisting of methanol/acetic acid/ammonia (100/0.15/0.15, v/v/v). An ion trap mass spectrometer with an electrospray interface was used for detection in the positive mode, monitoring the m/z transition 268-->191 for metoprolol. Standard curves for S- and R-metoprolol fitted quadratic functions (r(2)>or=0.9995) over the range 0.5-50 microg/L in plasma, with 0.5 microg/L representing the limit of quantification. In this range, relative standard deviations were <6% for intra-day precision and <10% for inter-day precision. The accuracy was within the range of 92-105%.  相似文献   

8.
A sensitive and specific high performance liquid chromatographic method for quantitation of topiramate in human serum was developed using HPLC with fluorescence labeling reagent. Topiramate was extracted from human serum by dichloromethane and derivatized by reaction with 9-fluorenylmethyl chloroformate (FMOC-Cl) in the presence of borate buffer. Analysis was performed on a CN column with sodium phosphate buffer (pH 2.2) containing 1 ml/l triethylamine and methanol (52:48 (v/v)) as mobile phase. Amantadine was used as internal standard. The standard curve was linear over the range 20-5000 ng/ml of topiramate in human serum. The mean intra-day precision was from 10.5% (low concentration) to 1.2% (high concentration) and the within-day precision from 1.5 to 12.5% determined on spiked samples. The accuracy of the method was 96.5-107.5% (intra-day) and 98.4-105% (inter-day). The limit of quantification was 20 ng/ml of serum. This method was used in a bioequivalence study after administration of 2 x 25 mg topiramate in 24 healthy volunteers.  相似文献   

9.
Liquid chromatography-electrospray ionization mass spectrometry methods are described for the simultaneous quantification of a bis-thiazolium compound (T3), its related prodrug (TE3) and an intermediate compound (mTE3) that appeared during the prodrug/drug conversion process, in human plasma, whole blood and red blood cells (RBCs). The methods involve solid phase extraction (SPE) of the compounds and the internal standard (verapamil) from the three different matrices using OasisHLB columns with an elution solvent of 2x1 ml of acetonitrile containing 1 ml/l trifluoroacetic acid (TFA). HPLC separation was performed on a C18 encapped Xterra column packed with 3.5 microm particles. The mobile phase used a 8 min gradient, from water containing 1 ml/l TFA to acetonitrile containing 1 ml/l TFA, at a flow rate of 400 microl/min. Verapamil and the TE3 compound were characterized by the protonated molecules at m/z 455 and m/z 541, respectively. The mTE3 species was detected through the (M)+ ion at m/z 497. The T3 compound was detected by use of two ions, the quaternary ammonium salt (M2+/2) at m/z 227.3 and by the adduct with TFA (M+TFA)+ at m/z 567.3. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (or whole blood) concentrations in the tested range of 6.4-1282 microg/l (12.8-2564 microg/kg) for T3, 20-2000 microg/l (40-4000 microg/kg) for mTE3 and 10-2000 microg/l (40-4000 microg/kg) for TE3, and to T3 concentrations in RBCs ranging from 12.8 to 2564 microg/kg. Inter-assay precision (in terms of R.S.D.) was below 13.5% and accuracy ranged from 95.4 to 107%. The dilution of the samples (plasma or whole blood) has no influence on the performance of the methods. The extraction recoveries averaged 87% for T3, 53% for mTE3 and 79% for TE3 in plasma; 79% for T3, 57% for mTE3 and 65% for TE3 in blood; and 93% for T3 in RBCs, and was constant across the calibration range. The lower limits of quantitation were 6.4 microg/l for T3, 20 microg/l for mTE3 and 10 microg/l for TE3 in plasma; 12.8 microg/kg for T3 and 40 microg/kg for mTE3 and TE3 in blood; and 12.8 microg/kg for T3 in RBCs. Stability tests under various conditions were also investigated. The three-step SPE procedure (loading, clean-up, and elution) described in this paper to quantify these new anti-malarial compounds in plasma, whole blood and RBCs, can easily be automated by using either robotisation or an automated sample preparation system.  相似文献   

10.
A fast analysis method using liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry was developed for the simultaneous determination of the 1-hydroxypyrene (1-OHP) and 3-hydroxybenzo[a]pyrene (3-OHBaP) in urine. Mass transitions were monitored at m/z 219.3-200.0 for 1-OHP and m/z 269.2-252.2 for 3-OHBaP. Only 10 min was needed for the analysis. The recovery was 60% for 3-OHBaP and 91% for 1-OHP, respectively. And the method detection limits were 0.49 microg/L for 1-OHP and 1.03 microg/L for 3-OHBaP. The inter- and intra-day relative standard deviations were in the range of 2.8-8.9% for 1-OHP and 9.7-20.8% for 3-OHBaP, respectively. The developed method was successfully used to measure urinary PAH metabolites of student volunteers in a high school.  相似文献   

11.
In order to quantify a small amount of a drug, 3,4-diaminopyridine (3,4-DAP), in animal plasma samples, an analytical method was developed. It involved an extraction of 3,4-DAP and phenylephrine, used as internal standard (IS), from plasma with solid-phase extraction (SPE) on C18 cartridges. This analytical method is a hyphenated technique based on high-performance liquid chromatography with electrochemical detection (HPLC-EC) whose purpose is to obtain first a sensitive method and second a satisfying separation between 3,4-DAP and phenylephrine. The analytical method is accurate, specific, and linear between 10 and 500 g of 3,4-DAP per litre. The recovery of 3,4-DAP is estimated at 70.8% with a 95% confidence interval of (66.0 -75.6%). Intermediate precision was evaluated on three quality control samples; the intra-day precision was estimated at 13.5, 9.1, 7.8% and the inter-day precision at 17.9, 8.4, 9.3%. The limit of quantification of the method was evaluated at 10 g l-1. First toxicokinetic parameters determined on dogs plasma samples after one 3,4-DAP oral administration of 1 mg kg-1 were: Cmax=395.7 microg l-1; Tmax =15 min; t1/2=113.6 min; Clearance/F=16.8 ml kg-1 min-1 and Vd/F=2.7 l kg -1.  相似文献   

12.
A screening procedure was developed for the identification and quantification of distigmine bromide in serum samples by using liquid chromatography (LC)-electrospray ionization (ESI)-mass spectrometry (MS). In this method, distigmine bromide was analyzed in 0.5 mL serum by using pancuronium bromide as the internal standard, and gradient elution was performed using a reversed-phase column and a mixture of 10 mM-ammonium formate and methanol as the mobile phase. A highly sensitive assay could be performed with simple solid phase extraction using a cation exchange cartridge column by carrying out selected ion monitoring analysis in the positive ion detection mode. The procedure was validated in terms of linearity (0.9973 at 2.5 ng/mL). The inter- and intra-day precisions (coefficient of variation; CV%) were <8.5% and < 9.7%, respectively. The analytes were evaluated for stability and were found to be stable in serum for 1 week at 4 degrees C and 4 weeks at -30 degrees C, and successfully applied to in the analysis of two overdose cases. This method is sensitive and useful for the detection, quantification, and confirmation of distigmine bromide in serum.  相似文献   

13.
A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were < or =14.0% for cefalexin and < or =11.4% for trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.  相似文献   

14.
A liquid chromatography-mass spectrometry (LC-MS) method was developed for the analysis of vancomycin (VCM) in human serum. The method was based on full scan data with extracted ions for the accurate masses of VCM and the atenolol internal standard obtained by Fourier transform MS. VCM was extracted from serum using strong cation exchange (SCX) solid phase extraction (SPE). The method was found to be linear in the range 0.05-10 microg/ml, which was adequate for quantification of VCM in serum samples, with a limit of quantification (LOQ) of 0.005 microg/ml and a limit of detection (LOD) of 0.001 microg/ml. Intra-day precision (n=5) was +/-3.5%, +/-2.5%, +/-0.7% at 0.05, 0.5 and 5 microg/ml, respectively. Inter-day precision (n=5) was +/-7.6%, +/-6.4%, +/-3.9% at 0.05, 0.5 and 5 microg/ml, respectively. The process efficiency for VCM was in the range 89.2-98.1% with the recovery for the atenolol internal standard (IS) being 97.3%. The method was used to determine VCM levels in patients during peri-operative infusion of the drug, which was found to result in drug levels within the required therapeutic window.  相似文献   

15.
Di-iso-nonylphthalate (DINP) is the major plasticizer for polyvinylchloride (PVC) polymers. Two DINP products are currently produced: DINP 1 and DINP 2. We analyzed the isononyl alcohol mixtures (INA) used for the synthesis of these two DINP plasticizer products and thus identified 4-methyloctanol-1 as one of the major constituents of the alkyl side chains of DINP 1 (8.7%) and DINP 2 (20.7%). Based on this isomer, we postulated the major DINP metabolites renally excreted by humans: mono-(4-methyl-7-hydroxy-octyl)phthalate (7OH-MMeOP), mono-(4-methyl-7-oxo-octyl)phthalate (7oxo-MMeOP) and mono-(4-methyl-7-carboxy-heptyl)phthalate (7carboxy-MMeHP). We present a fast and reliable on-line clean-up HPLC method for the simultaneous determination of these three DINP metabolites in human urine. We used ESI-tandem mass spectrometry for detection and isotope dilution for quantification (limit of quantification 0.5microg/l). Via these three oxidised DINP isomer standards, we quantified the excretion of all oxidised DINP isomers with hydroxy (OH-MINP), oxo (oxo-MINP) and carboxy (carboxy-MINP) functional groups. With this approach, we can for the first time reliably quantify the internal burden of the general population to DINP. Mean urinary metabolite concentrations in random samples from the general German population (n=25) were 14.9microg/l OH-MINP, 8.9microg/l oxo-MINP and 16.4microg/l carboxy-MINP. Metabolites strongly correlated with each other over all samples analyzed (R>0.99, p<0.0001).  相似文献   

16.
The purpose of the present work was the development and validation of a simple, rapid and reliable method for direct bromide quantification in serum based on capillary electrophoresis (CE). The analysis was carried out with an automated capillary electropherograph. Analytical conditions were as follows. Capillary: uncoated fused silica, effective length 50 cm, internal diameter 50 microm; voltage: 20 kV in reverse polarity mode; temperature: 25 degrees C; running buffer: 90 mmol/L sodium tetraborate decahydrate and 10 mmol/L NaCl, pH 9.24; detection: direct UV absorption at 200 nm; sample treatment: dilution of serum 1:10 with the internal standard solution (2 mmol/L thiocyanate). Under the described conditions, bromide ions and internal standard were baseline separated in 7 min. No interferences from other serum components were observed. The analytical sensitivity was characterized by a LOD: 0.05 mmol/L and a LOQ of 0.1 mmol/L. Excellent linearity was verified in the range from 2.5 to 60 mmol/L [y = 0.0746x - 0.0372; R2 = 0.9995 (x = bromide concentration; y = bromide peak area/internal standard (I.S.) peak area)]. Quantitative imprecision in intra-day (n = 7) and day-to-day (n = 7) experiments was always within R.S.D. values <2%. Recovery was quantitative throughout the range of linearity of the method. Clinical cases of infants undergoing potassium bromide therapy for refractory epilepsy were analyzed with results in agreement with literature data. On the basis of these considerations, capillary electrophoresis can be proposed as the method of choice for bromide analysis in serum samples, especially for therapeutic drug monitoring purposes.  相似文献   

17.
Neopterin plays an important role in the malignant disease diagnostics. However, the methods employed in neopterin determination are generally difficult and/or time consuming. The aim of this work was to standardize a practical method to quantify neopterin using high-performance liquid chromatography-ultraviolet (HPLC-UV) and quantify it in patients with systemic lupus erythematosus (SLE). Urine was collected from healthy subjects (n= 49), patients with inactive (n= 15), active (n= 28), and highly active SLE (n= 6). The HPLC was performed using two coupled reverse-phase columns eluted with 150 mM sodium phosphate, pH 4.0, under a flow rate of 0.8 ml/min, with UV detector set at 353 nm and 100-fold diluted urines. The inter- and intra-assay studies presented an imprecision of 12.5% and 12.9% for quality controls of 3.94 and 1.1 micromol/ml, respectively. Recovery from 79.5% to 82% was observed throughout the assay's linear range. Subjects with active (874.2 +/- 165.38 micromol/mol creatinin) and highly active SLE (1753.8 +/- 453.9 micromol/mol creatinin) showed three- and sixfold increased neopterin levels, respectively, compared to subjects with inactive SLE (314.3 +/- 121.3 micromol/mol creatinin) and healthy subjects (294.6 +/- 178.6 micromol/mol creatinin) (P< 0.05). Briefly, the proposed method was precise, specific, and reproducible, not invasive and allows the urinary neopterin quantification only with UV detection.  相似文献   

18.
A method was developed for the determination of the seven nitroimidazoles including metronidazole (MNZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), secnidazole (SNZ) and the common metabolite of RNZ and hydroxydimetridazole (DMOHZ) in poultry and pork muscles by high-performance liquid chromatography (HPLC) with ultraviolet detection (UV). After extraction with ethyl acetate and evaporation, the nitroimidazoles were redissolved in ethyl acetate and purified using strong cation exchange (SCX) solid-phase extraction (SPE) column. The HPLC separation was carried through on a C(18) bonded silica column with a deionized water-methanol-acetonitrile mobile phase using a gradient elution procedure. The limit of detection of all the seven nitroimidazoles was 0.2 microg/kg. The recoveries of the seven nitroimidazoles for chicken, pork and bacon samples spiked with 1-20 microg/kg were in the range of 71.4-99.5%. The linearity is satisfactory with a correlation coefficient of >0.998 at concentrations ranging from 0.7 to 60 microg/kg. The relative standard deviations of 10 measurements for spiked chicken, pork and bacon samples at the concentration of 1 and 20 microg/kg were in the range of 6.2-13.9% and 4.0-8.7%, respectively. The intra-day precision (n=5) for nitroimidazoles residues in chicken spiked at 20 microg/kg is 6.9%, and the inter-day precision for 5 days (n=25) is 11%. The method is capable of identifying nitroimidazole residues at > or =0.7 microg/kg levels and was applied in the determination of nitroimidazole residues in meat sample.  相似文献   

19.
An analytical method for simultaneous determination of erythromycin propionate and its active metabolite, erythromycin base, in human plasma by high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS) was developed and validated. Roxithromycin was selected as the internal standard. The samples were directly injected after simple deproteinized procedure only. The separation was achieved on a Johnson Spherigel analytical column packed with 5 microm C18 silica, employing acetonitrile -0.1% formic acid aqueous solution (50:50) as mobile phase. The quantification of target compounds was obtained by using a selected ion monitoring (SIM) at m/z 790.7 for erythromycin propionate, m/z 734.7 for erythromycin base and m/z 837.8 for roxithromycin. The correlation coefficients of the calibration curves were better than 0.997 (n=6), in the ranges from 2 ng/ml to 1 microg/ml, and from 1 to 10 microg/ml for erythromycin propionate and base. The method can provide the necessary sensitivity, precision and accuracy to allow the simultaneous determination of both compounds in a patient's plasma following a single administration of erythromycin stinoprate capsule (500 mg erythromycin base equivalent).  相似文献   

20.
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify artemisinin in rat serum. The lower limit of quantification (LLOQ) was 4 ng/mL. The calibration curve was linear from 4 ng/mL to 10,000 ng/mL (R=0.998). The assay was based on the selected reaction monitoring (SRM) transitions at m/z 305.4-151.10 for artemisinin and m/z 335.2-163.10 for arteether (internal standard). The artemisinin and internal standard can be separated from endogenous interferences in rat serum. Inter- and intra-day assay variation was less than 15%. The extraction recoveries ranged from 80.0 to 107.3% at the three concentrations (5000, 2000, and 200 ng/mL). This method was successfully applied to pharmacokinetic studies of artemisinin after intravenous and oral administration to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号