首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Functional diagnostic parameters such as Fractional Flow Reserve (FFR), which is calculated from pressure measurements across stenosed arteries, are often used to determine the functional severity of coronary artery stenosis. This study evaluated the effect of arterial wall-stenosis compliance, with limiting scenarios of stenosis severity, on the diagnostic parameters. The diagnostic parameters considered in this study include an established index, FFR and two recently developed parameters: Pressure Drop Coefficient (CDP) and Lesion Flow Coefficient (LFC). The parameters were assessed for rigid artery (RR; signifying high plaque elasticity), compliant artery with calcified plaque (CC; intermediate plaque elasticity) and compliant artery with smooth muscle cell proliferation (CS; low plaque elasticity), with varying degrees of epicardial stenosis. A hyperelastic Mooney-Rivlin model was used to model the arterial wall and plaque materials. Blood was modeled as a shear thinning, non-Newtonian fluid using the Carreau model. The arterial wall compliance was evaluated using the finite element method. The present study found that, with an increase in stenosis severity, FFR decreased whereas CDP and LFC increased. The cutoff value of 0.75 for FFR was observed at 78.7% area stenosis for RR, whereas for CC and CS the cutoff values were obtained at higher stenosis severities of 81.3% and 82.7%, respectively. For a fixed stenosis, CDP value decreased and LFC value increased with a decrease in plaque elasticity (RR to CS). We conclude that the differences in diagnostic parameters with compliance at intermediate stenosis (78.7-82.7% area blockage) could lead to misinterpretation of the stenosis severity.  相似文献   

2.
Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid–structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information.  相似文献   

3.
The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.  相似文献   

4.
Mathematical modelling of flow through an irregular arterial stenosis.   总被引:2,自引:0,他引:2  
A mathematical model of flow through an irregular arterial stenosis is developed. The model is two-dimensional and axi-symmetric with the stenosis outline obtained from a three-dimensional casting of a mildly stenosed artery. Agreement between modelled and experimental pressure drops (obtained from an axi-symmetric machined stenosis with the same profile) is excellent. Results are also obtained for a smooth stenosis model, similar to that used for most mathematical modelling studies. This model overestimates the pressure drop across the stenosis, as well as the wall shear stress and separation Reynolds number. Also, the smooth model predicts one instead of three recirculation zones present in the irregular model. The original stenosis is modified to increase the severity from 48 and 87% areal occlusion, while maintaining the same general shape. This has the effect of increasing the pressure drop by an order of magnitude and decreasing the number of recirculation zones to one, with a lower separation Reynolds number.  相似文献   

5.
This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.  相似文献   

6.
A new model is used to analyze the fully coupled problem of pulsatile blood flow through a compliant, axisymmetric stenotic artery using the finite element method. The model uses large displacement and large strain theory for the solid, and the full Navier-Stokes equations for the fluid. The effect of increasing area reduction on fluid dynamic and structural stresses is presented. Results show that pressure drop, peak wall shear stress, and maximum principal stress in the lesion all increase dramatically as the area reduction in the stenosis is increased from 51 to 89 percent. Further reductions in stenosis cross-sectional area, however, produce relatively little additional change in these parameters due to a concomitant reduction in flow rate caused by the losses in the constriction. Inner wall hoop stretch amplitude just distal to the stenosis also increases with increasing stenosis severity, as downstream pressures are reduced to a physiological minimum. The contraction of the artery distal to the stenosis generates a significant compressive stress on the downstream shoulder of the lesion. Dynamic narrowing of the stenosis is also seen, further augmenting area constriction at times of peak flow. Pressure drop results are found to compare well to an experimentally based theoretical curve, despite the assumption of laminar flow.  相似文献   

7.
Functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the stenosis. However, when there are functional collaterals operating downstream to the stenosis, the coronary flow-rate increases, and the pressure in the stenosed artery is altered. This effect of downstream collaterals on different diagnostic parameters is studied using a physiological representative in vitro coronary flow-loop.The three diagnostic parameters tested are fractional flow reserve (FFR), lesion flow coefficient (LFC), and pressure drop coefficient (CDP). The latter two were discussed in recent publications by our group (Banerjee et al., 2008, Banerjee et al., 2007, 2009). They are evaluated for three different severities of stenosis and tested for possible misinterpretation in the presence of variable collateral flows. Pressure and flow are measured with and without downstream collaterals. The diagnostic parameters are then calculated from these readings.In the case of intermediate stenosis (80% area blockage), FFR and LFC increased from 0.74 to 0.77 and 0.58 to 0.62, respectively, for no collateral to fully developed collateral flow. Also, CDP decreased from 47 to 42 for no collateral to fully developed collateral flow. These changes in diagnostic parameters might lead to erroneous postponement of coronary intervention. Thus, variability in diagnostic parameters for the same stenosis might lead to misinterpretation of stenosis severity in the presence of operating downstream collaterals.  相似文献   

8.
Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.  相似文献   

9.
Severe stenosis may cause critical flow and wall mechanical conditions related to artery fatigue, artery compression, and plaque rupture, which leads directly to heart attack and stroke. The exact mechanism involved is not well understood. In this paper a nonlinear three-dimensional thick-wall model with fluid-wall interactions is introduced to simulate blood flow in carotid arteries with stenosis and to quantify physiological conditions under which wall compression or even collapse may occur. The mechanical properties of the tube wall were selected to match a thick-wall stenosis model made of PVA hydrogel. The experimentally measured nonlinear stress-strain relationship is implemented in the computational model using an incremental linear elasticity approach. The Navier-Stokes equations are used for the fluid model. An incremental boundary iteration method is used to handle the fluid-wall interactions. Our results indicate that severe stenosis causes considerable compressive stress in the tube wall and critical flow conditions such as negative pressure, high shear stress, and flow separation which may be related to artery compression, plaque cap rupture, platelet activation, and thrombus formation. The stress distribution has a very localized pattern and both maximum tensile stress (five times higher than normal average stress) and maximum compressive stress occur inside the stenotic section. Wall deformation, flow rates, and true severities of the stenosis under different pressure conditions are calculated and compared with experimental measurements and reasonable agreement is found.  相似文献   

10.
Arteries with high-grade stenoses may compress under physiologic conditions due to negative transmural pressure caused by high-velocity flow passing through the stenoses. To quantify the compressive conditions near the stenosis, a nonlinear axisymmetric model with fluid-wall interactions is introduced to simulate the viscous flow in a compliant stenotic tube. The nonlinear elastic properties of the tube (tube law) are measured experimentally and used in the model. The model is solved using ADINA (Automatic Dynamic Incremental Nonlinear Analysis), which is a finite element package capable of solving problems with fluid-structure interactions. Our results indicate that severe stenoses cause critical flow conditions such as negative pressure and high and low shear stresses, which may be related to artery compression, plaque cap rupture, platelet activation, and thrombus formation. The pressure filed near a stenosis has a complex pattern not seen in one-dimensional models. Negative transmural pressure as low as -24 mmHg for a 78 percent stenosis by diameter is observed at the throat of the stenosis for a downstream pressure of 30 mmHg. Maximum shear stress as a high as 1860 dyn/cm2 occurs at the throat of the stenoses, while low shear stress with reversed direction is observed right distal to the stenosis. Compressive stresses are observed inside the tube wall. The maximal principal stress and hoop stress in the 78 percent stenosis are 80 percent higher than that from the 50 percent stenosis used in our simulation. Flow rates under different pressure drop conditions are calculated and compared with experimental measurements and reasonable agreement is found for the prebuckling stage.  相似文献   

11.
A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis. Cardiac catheterization was performed on 11 Yorkshire pigs. Simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire for HR < 120 and HR > 120 beats/min, in the presence of epicardial coronary lesions of <50% AS and >50% AS. The mean values of FFR, CDP(e), and LFC were significantly different (P < 0.05) for lesions of <50% AS and >50% AS (0.88 ± 0.04, 0.76 ± 0.04; 62 ± 30, 151 ± 35, and 0.10 ± 0.02 and 0.16 ± 0.01, respectively). The mean values of FFR and CDP(e) were not significantly different (P > 0.05) for variable HR conditions of HR < 120 and HR > 120 beats/min (FFR, 0.81 ± 0.04 and 0.82 ± 0.04; and CDP(e), 95 ± 33 and 118 ± 36). The mean values of LFC do somewhat vary with HR (0.14 ± 0.01 and 0.12 ± 0.02). In conclusion, fluctuations in HR have no significant influence on the measured values of CDP(e) and FFR but have a marginal influence on the measured values of LFC. However, all three parameters can significantly differentiate between stenosis severities. These results suggest that the diagnostic parameters can be potentially used in a better assessment of coronary stenosis severity under a clinical setting.  相似文献   

12.

Background  

The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses.  相似文献   

13.
The coupled oxygen transport in the avascular wall of a coronary artery stenosis is studied numerically by solving the convection-diffusion equations. Two geometries replicating stenosis before and after percutaneous transluminal coronary angioplasty (PTCA) are used for the analysis. The results are compared to evaluate the effect of the degree of stenosis on oxygen transport. Important physiological aspects, such as oxygen consumption in the wall, oxygen carried by the hemoglobin, non-Newtonian viscosity of the blood, and supply of oxygen from the vasa vasorum are included. The results show that the PO2 in the medial region of the arterial wall is approximately 10mmHg. The oxygen flux to the wall increases in the flow acceleration region, whereas it decreases at the flow reattachment zone. Near the location of flow separation, there is a small rise followed by a sharp fall in the oxygen flux. The drop in the oxygen flux to the wall at the point of flow reattachment for pre-PTCA stenosis is four times that for post-PTCA stenosis. The minimum PO2 in the avascular wall, PO2,min, at this location decreases to approximately 6.0 and 4.2mmHg for post- and pre-PTCA stenosis, respectively. The drop in PO2,w and PO2,min at the point of flow reattachment for pre-PTCA is approximately 2 times that for post-PTCA stenosis. Thus, the present study quantifies the oxygen transport to the arterial wall before and after cardiovascular intervention.  相似文献   

14.
A simple model is presented to analyze the effect of stenoses of different severities in a long elastic tube or artery on the pressure and flow-rate wave forms incident upon them. Wave propagation in the undisturbed tube is taken to be linear; nonlinearity arises from the quadratic dependence of stenosis pressure drop on flow rate. Before the model can be applied in practice, important physiological questions must be answered; e.g.: (a) Can the incident wave form and mean proximal pressure be regarded as given input? (b) is the mean flow rate given, or does the peripheral resistance remain constant? Results are given on the assumption that the answer to (a) is yes. The principal conclusion is that the input impedance spectrum of a stenosed artery depends strongly on the incident wave form, as well as on the severity of the stenosis and on the distance from it at which measurements are made. There is good qualitative agreement with the results of experiments and of other models.  相似文献   

15.
Measurement of left anterior descending coronary arterial pressure, phasic coronary flow, and intramyocardial pressure in an open-chest dog provided data, which when entered into the computer model of the coronary circulation, permitted calculation of coronary artery compliance and resistance during systole and diastole. Resting in vivo compliance averaged 0.21 x 10(-3) mL/mmHg (1 mmHg = 133.322 Pa) while systolic resistance averaged 4.05 mmHg X min-1 X mL-1 and during diastole 2.06 mmHg X min-1 X mL-1. Left stellate ganglion stimulation or vasodilation caused minimal changes in compliance but glutaraldehyde applied to arterial wall caused a decrease in compliance. Sympathetic stimulation and vasodilation decreased both diastolic and systolic resistance. Transmural distribution of coronary flow was not significantly altered by the experimental changes in compliance and resistance.  相似文献   

16.
The purpose of this study was to investigate the hemodynamic effect of variations in the angulations of the left coronary artery, based on simulated and realistic coronary artery models. Twelve models consisting of four realistic and eight simulated coronary artery geometries were generated with the inclusion of left main stem, left anterior descending and left circumflex branches. The simulated models included various coronary artery angulations, namely, 15°, 30°, 45°, 60°, 75°, 90°, 105° and 120°. The realistic coronary angulations were based on selected patient's data with angles ranging from narrow angles of 58° and 73° to wide angles of 110° and 120°. Computational fluid dynamics analysis was performed to simulate realistic physiological conditions that reflect the in vivo cardiac hemodynamics. The wall shear stress, wall shear stress gradient, velocity flow patterns and wall pressure were measured in simulated and realistic models during the cardiac cycle. Our results showed that a disturbed flow pattern was observed in models with wider angulations, and wall pressure was found to reduce when the flow changed from the left main stem to the bifurcated regions, based on simulated and realistic models. A low wall shear stress gradient was demonstrated at left bifurcations with wide angles. There is a direct correlation between coronary angulations and subsequent hemodynamic changes, based on realistic and simulated models. Further studies based on patients with different severities of coronary artery disease are required to verify our results.  相似文献   

17.
Abnormal haemodynamic parameters are associated with atheroma plaque progression and instability in coronary arteries. Flow recirculation, shear stress and pressure gradient are understood to be important pathogenic mediators in coronary disease. The effect of freedom of coronary artery movement on these parameters is still unknown. Fluid–structure interaction (FSI) simulations were carried out in 25 coronary artery models derived from authentic human coronaries in order to investigate the effect of degree of freedom of movement of the coronary arteries on flow recirculation, wall shear stress (WSS) and wall pressure gradient (WPG). Each FSI model had distinctive supports placed upon it. The quantitative and qualitative differences in flow recirculation, maximum wall shear stress (MWSS), areas of low wall shear stress (ALWSS) and maximum wall pressure gradient (MWPG) for each model were determined. The results showed that greater freedom of movement was associated with lower MWSS, smaller ALWSS, smaller flow recirculation zones and lower MWPG. With increasing percentage diameter stenosis (%DS), the effect of degree of freedom on flow recirculation and WSS diminished. Freedom of movement is an important variable to be considered for computational modelling of human coronary arteries, especially in the setting of mild to moderate stenosis.

Abbreviations: 3D: Three-dimensional; 3DR: Three-dimensional Reconstruction; 3D-QCA: Three-dimensional quantitative coronary angiography; ALWSS: Areas of low wall shear stress; CAD: Coronary artery disease; CFD: Computational fluid dynamics; %DS: Diameter stenosis percentage; EPCS: End point of counter-rotating streamlines; FSI: Fluid–structure interaction; IVUS: Intravascular ultrasound; LAD: Left anterior descending; MWSS: Maximum wall shear stress; SST: Shear stress transport; TAWSS: Time-averaged wall shear stress; WSS: wall shear stress; WPG: Wall pressure gradient; MWPG: Maximum wall pressure gradient; FFR: Fractional flow reserve; iFR: Instantaneous wave-free ratio  相似文献   


18.
The fluid mechanics of blood flow in a catheterized curved artery with stenosis is studied through a mathematical analysis. Blood is modelled as an incompressible Newtonian fluid and the flow is assumed to be steady and laminar. An approximate analytic solution to the problem is obtained through a double series perturbation analysis for the case of small curvature and mild stenosis. The effect of catheterization on various physiologically important flow characteristics (i.e. the pressure drop, impedance and the wall shear stress) is studied for different values of the catheter size and Reynolds number of the flow. It is found that all these flow characteristics vary markedly across a stenotic lesion. Also, increase in the catheter size leads to a considerable increase in their magnitudes. These results are used to obtain the estimates of increased pressure drop across an arterial stenosis when a catheter is inserted into it. Our calculations, based on the geometry and flow conditions existing in coronary arteries, suggest that, in the presence of curvature and stenosis, and depending on the value of k (ratio of catheter size to vessel size) ranging from 0.1 to 0.4, the pressure drop increases by a factor ranging from 1.60 to 5.16. But, in the absence of curvature and stenosis, with the same range of catheter size, this increased factor is about 1.74-4.89. These estimates for the increased pressure drop can be used to correct the error involved in the measured pressure gradients using catheters. The combined effects of stenosis and curvature on flow characteristics are also studied in detail. It is found that the effect of stenosis is more dominant than that of the curvature. Due to the combined effect of stenosis, curvature and catheterization, the secondary streamlines are modified in a cross-sectional plane. The insertion of a catheter into the artery leads to the formation of increased number of secondary vortices.  相似文献   

19.

Atherosclerotic plaque in the femoral is the leading cause of peripheral artery disease (PAD), the worse consequence of which may lead to ulceration and gangrene of the feet. Numerical studies on fluid-structure interactions (FSI) of atherosclerotic femoral arteries enable quantitative analysis of biomechanical features in arteries. This study aims to investigate the hemodynamic performance and its interaction with femoral arterial wall based on the patient-specific model with multiple plaques (calcified and lipid plaques). Three types of models, calcification-only, lipid-only and calcification-lipid models, are established. Hyperelastic material coefficients of the human femoral arteries obtained from experimental studies are employed for all simulations. Oscillation of WSS is observed in the healthy downstream region in the lipid-only model. The pressure around the plaques in the two-plaque model is lower than that in the corresponding one-plaque models due to the reduction of blood flow domain, which consequently diminishes the loading forces on both plaques. Therefore, we found that stress acting on the plaques in the two-plaque model is lower than that in the corresponding one-plaque models. This finding implies that the lipid plaque, accompanied by the calcified plaque around, might reduce its risk of rupture due to the reduced the stress acting on it.

  相似文献   

20.
Hemodynamic characteristics of blood flow through arterial stenoses are numerically investigated in this work. The blood is assumed as a Newtonian fluid and the pulsatile nature of flow is modeled by using measured values of the flowrate and pressure for the canine femoral artery. An isotropic elastic and incompressible material is assumed for the wall at each axial section, but a non-uniform distribution of the shear modulus in axial direction is used to model the high stiffness of the wall at the stenosis location. Full Navier equations for a thick wall are used as the governing equations for the wall displacements. A continuous grid extending over the flow field and the wall is considered and governing equations are transformed for use in the computational domain. Discretized forms of the transformed wall and flow equations, which are coupled through the boundary conditions at their interface, are obtained by control volume method and simultaneously solved using the well-known SIMPLER algorithm. To study the effects of wall deformability, solutions are obtained for both rigid and elastic walls. The results indicate that deformability of the wall causes an increase in the time average of pressure drop, but a decrease in the maximum wall shear stress. Displacement and stress distributions in the wall are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏