首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 +/- 5.8 CFU/m2 for wet sampling and 100.5 +/- 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site.  相似文献   

2.
The present study had three goals: (i) to evaluate the relative quantities of aerosolized Bacillus atrophaeus spores deposited on the vertical, horizontal top, and horizontal bottom surfaces in a chamber; (ii) to assess the relative recoveries of the aerosolized spores from glass and stainless steel surfaces with a polyester swab and a macrofoam sponge wipe; and (iii) to estimate the relative recovery efficiencies of aerosolized B. atrophaeus spores and Pantoea agglomerans using a foam spatula at several different bacterial loads by aerosol distribution on glass surfaces. The majority of spores were collected from the bottom horizontal surface regardless of which swab type and extraction protocol were used. Swabbing with a macrofoam sponge wipe was more efficient in recovering spores from surfaces contaminated with high bioaerosol concentrations than swabbing with a polyester swab. B. atrophaeus spores and P. agglomerans culturable cells were detected on glass surfaces using foam spatulas when the theoretical surface bacterial loads were 2.88 × 104 CFU and 8.09 × 106 CFU per 100-cm2 area, respectively. The median recovery efficiency from the surfaces using foam spatulas was equal to 9.9% for B. atrophaeus spores when the recovery was calculated relative to the theoretical surface spore load. Using a foam spatula permits reliable sampling of spores on the bioaerosol-exposed surfaces in a wide measuring range. The culturable P. agglomerans cells were recovered with a median efficiency of 0.001%, but staining the swab extracts with fluorescent dyes allowed us to observe that the viable cell numbers were higher by 1.83 log units than culturable organisms. However, additional work is needed to improve the analysis of the foam extracts in order to decrease the limit of detection of Bacillus spores and Gram-negative bacteria on contaminated surfaces.Surface sampling is performed on a frequent basis in all situations where clean environment monitoring is needed, e.g., in health care facilities and in the pharmaceutical industry and food industry. An anthrax bioterrorist event in the fall of 2001 has emphasized the importance of efficient sampling methods for detection of pathogenic microorganisms on surfaces within intentionally contaminated locations (22). Unfortunately, our knowledge on the most effective sampling methodology as well as the level of confidence we may have in the results obtained by wiping, swabbing, and other sample collection strategies is still limited (1). Moreover, in most of the studies performed so far, bacteria and/or spores were collected from test samples or coupons of various materials, inoculated with a suspension of microorganisms that had been placed and spread over the surface, and then dried (14, 15). This may not mimic the true situation of surface contamination by a pathogen that has been intentionally released. Edmonds et al. (12) recently reported lower swabbing efficiencies of different types of swab materials used for sampling glass, polycarbonate, and vinyl surfaces contaminated with dry aerosol-deposited Bacillus atrophaeus spores compared to the surfaces inoculated by spore suspensions. Solid surface contamination from exposure to aerosolized spores fits the real world better than the previous models.Therefore, in our study we decided to generate aerosols of various concentrations of B. atrophaeus spores as well as the vegetative cells of Pantoea agglomerans inside a chamber where the bioaerosol particles were allowed to gravitationally settle on solid surfaces. The aerosolization of P. agglomerans was performed to verify the recovery of Gram-negative bacteria according to the recommendations of Budowle et al. (5). The main goal of our study was to establish the range of detection when bioaerosol-contaminated surfaces were swabbed using a commercially available foam spatula.  相似文献   

3.
The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus (“Bacillus subtilis subsp. niger,” also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 105 to 106 CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies.  相似文献   

4.
AIM: To evaluate US Centers for Disease Control and Prevention recommended swab surface sample collection method for recovery efficiency and limit of detection for powdered Bacillus spores from nonporous surfaces. METHODS AND RESULTS: Stainless steel and painted wallboard surface coupons were seeded with dry aerosolized Bacillus atrophaeus spores and surface concentrations determined. The observed mean rayon swab recovery efficiency from stainless steel was 0.41 with a standard deviation (SD) of +/-0.17 and for painted wallboard was 0.41 with an SD of +/-0.23. Evaluation of a sonication extraction method for the rayon swabs produced a mean extraction efficiency of 0.76 with an SD of +/-0.12. Swab recovery quantitative limits of detection were estimated at 25 colony forming units (CFU) per sample area for both stainless steel and painted wallboard. CONCLUSIONS: The swab sample collection method may be appropriate for small area sampling (10 -25 cm2) with a high agent concentration, but has limited value for large surface areas with a low agent concentration. The results of this study provide information necessary for the interpretation of swab environmental sample collection data, that is, positive swab samples are indicative of high surface concentrations and may imply a potential for exposure, whereas negative swab samples do not assure that organisms are absent from the surfaces sampled and may not assure the absence of the potential for exposure. SIGNIFICANCE AND IMPACT OF THE STUDY: It is critical from a public health perspective that the information obtained is accurate and reproducible. The consequence of an inappropriate public health response founded on information gathered using an ineffective or unreliable sample collection method has the potential for undesired social and economic impact.  相似文献   

5.
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.  相似文献   

6.
The aim of this study was to quantify reaerosolization of microorganisms caused by walking on contaminated flooring to assess the risk to individuals accessing areas contaminated with pathogenic organisms, for example, spores of Bacillus anthracis. Industrial carpet and polyvinyl chloride (PVC) floor coverings were contaminated with aerosolized spores of Bacillus atrophaeus by using an artist airbrush to produce deposition of ∼103 to 104 CFU · cm−2. Microbiological air samplers were used to quantify the particle size distribution of the aerosol generated when a person walked over the floorings in an environmental chamber. Results were expressed as reaerosolization factors (percent per square centimeter per liter), to represent the ratio of air concentration to surface concentration generated. Walking on carpet generated a statistically significantly higher reaerosolization factor value than did walking on PVC (t = 20.42; P < 0.001). Heavier walking produced a statistically significantly higher reaerosolization factor value than did lighter walking (t = 12.421; P < 0.001). Height also had a statistically significant effect on the reaerosolization factor, with higher rates of recovery of B. atrophaeus at lower levels, demonstrating a height-dependent gradient of particle reaerosolization. Particles in the respirable size range were recovered in all sampling scenarios (mass mean diameters ranged from 2.6 to 4.1 μm). The results of this study can be used to produce a risk assessment of the potential aerosol exposure of a person accessing areas with contaminated flooring in order to inform the choice of appropriate respiratory protective equipment and may aid in the selection of the most suitable flooring types for use in health care environments, to reduce aerosol transmission in the event of contamination.  相似文献   

7.
A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm2 (four separate 929 cm2 areas), larger than the 645 cm2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p  =  0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p  =  0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.  相似文献   

8.
This project examined dry, fluidized spore reaerosolization in a heating, ventilating, and air conditioning duct system. Experiments using spores of Bacillus atrophaeus, a nonpathogenic surrogate for Bacillus anthracis, were conducted to delineate the extent of spore reaerosolization behavior under normal indoor airflow conditions. Short-term (five air-volume exchanges), long-term (up to 21,000 air-volume exchanges), and cycled (on-off) reaerosolization tests were conducted using two common duct materials. Spores were released into the test apparatus in turbulent airflow (Reynolds number, 26,000). After the initial pulse of spores (approximately 1010 to 1011 viable spores) was released, high-efficiency particulate air filters were added to the air intake. Airflow was again used to perturb the spores that had previously deposited onto the duct. Resuspension rates on both steel and plastic duct materials were between 10−3 and 10−5 per second, which decreased to 10 times less than initial rates within 30 min. Pulsed flow caused an initial spike in spore resuspension concentration that rapidly decreased. The resuspension rates were greater than those predicted by resuspension models for contamination in the environment, a result attributed to surface roughness differences. There was no difference between spore reaerosolization from metal and that from plastic duct surfaces over 5 hours of constant airflow. The spores that deposited onto the duct remained a persistent source of contamination over a period of several hours.  相似文献   

9.
Persistence of Bacillus atrophaeus subsp. globigii spores on corroded iron coupons in drinking water was studied using a biofilm annular reactor. Spores were inoculated at 106 CFU/ml in the dechlorinated reactor bulk water. The dechlorination allowed for observation of the effects of hydraulic shear and biofilm sloughing on persistence. Approximately 50% of the spores initially adhered to the corroded iron surface were not detected after 1 month. Addition of a stable 10 mg/liter free chlorine residual after 1 month led to a 2-log10 reduction of adhered B. atrophaeus subsp. globigii, but levels on the coupons quickly stabilized thereafter. Increasing the free chlorine concentration to 25 or 70 mg/liter had no additional effect on inactivation. B. atrophaeus subsp. globigii spores injected in the presence of a typical distribution system chlorine residual (~0.75 mg/liter) resulted in a steady reduction of adhered B. atrophaeus subsp. globigii over 1 month, but levels on the coupons eventually stabilized. Adding elevated chlorine levels (10, 25, and 70 mg/liter) after 1 month had no effect on the rate of inactivation. Decontamination with elevated free chlorine levels immediately after spore injection resulted in a 3-log10 reduction within 2 weeks, but the rate of inactivation leveled off afterward. This indicates that free chlorine did not reach portions of the corroded iron surface where B. atrophaeus subsp. globigii spores had adhered. B. atrophaeus subsp. globigii spores are capable of persisting for an extended time in the presence of high levels of free chlorine.  相似文献   

10.
The ability to reliably and reproducibly sample surfaces contaminated with a biological agent is a critical step in measuring the extent of contamination and determining if decontamination steps have been successful. The recovery operations following the 2001 attacks with Bacillus anthracis spores were complicated by the fact that no standard sample collection format or decontamination procedures were established. Recovery efficiencies traditionally have been calculated based upon biological agents which were applied to test surfaces in a liquid format and then allowed to dry prior to sampling tests, which may not be best suited for a real-world event with aerosolized biological agents. In order to ascertain if differences existed between air-dried liquid deposition and biological spores which were allowed to settle on a surface in a dried format, a study was undertaken to determine if differences existed in surface sampling recovery efficiencies for four representative surfaces. Studies were then undertaken to compare sampling efficiencies between liquid spore deposition and aerosolized spores which were allowed to gradually settle under gravity on four different test coupon types. Tests with both types of deposition compared efficiencies of four unique swabbing materials applied to four surfaces with various surface properties. Our studies demonstrate that recovery of liquid-deposited spores differs significantly from recovery of dry aerosol-deposited spores in most instances. Whether the recovery of liquid-deposited spores is overexaggerated or underrepresented with respect to that of aerosol-deposited spores depends upon the surface material being tested.  相似文献   

11.
After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm2). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm2) or wipe or vacuum (929 cm2) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm2) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm2 for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm2 for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans.Anthrax, the spectrum of diseases caused by infection with Bacillus anthracis, is not considered a communicable disease but is generally acquired via environmental exposures. Many anthrax cases through history have been the result of agricultural or industrial exposure to B. anthracis spores (33). The disease most often presents itself as a cutaneous infection; however, there are both gastrointestinal and inhalational forms of the disease. Inhalational anthrax is typically rapidly fatal, even with treatment. In general, inhalation exposures require specific conditions, such as poor ventilation and activities that disturb dust containing B. anthracis spores (13).Because diagnosing anthrax in its early stages in human and animal hosts is difficult and B. anthracis spores are extremely stable in the environment, this microorganism has been investigated, developed, and deployed as a biological weapon throughout the 20th century. Use of this microorganism has seen varied success during World War I (9) and subsequently. It is generally accepted that there was an accidental release of B. anthracis spores from a weapons manufacturing or development facility in 1979 in Sverdlovsk, USSR (now Yekaterinaburg, Russia) (10, 26). In 1993, an attempt by a civilian group, Aum Shinrikyo, to use this microorganism to attack a civilian population in a Tokyo suburb did not result in any casualties (22, 28).In 2001, envelopes containing a powder formulation of B. anthracis were mailed in the United States to several individuals. These letters were the presumed cause of 22 cases of clinical anthrax, 11 inhalational and 11 cutaneous, with 5 fatalities, all of whom suffered from inhalational disease (34). According to congressional testimony, the powdered spore suspension was “easily dispersed into the air” (29). Of the 11 individuals with inhalational disease, 2 had no history of handling mail or having any other direct contact with these threat letters (11, 21). Of the remaining nine individuals, eight were thought to have been exposed through handling or processing mail (20) but may never have picked up or directly handled the actual threat letters. Thus, some individuals who contracted inhalational disease may have been exposed to aerosols that were generated from residual spore material deposited on contaminated surfaces. This conclusion was borne out by a study conducted on the scene of one contamination incident, which demonstrated that spores could be reaerosolized from surfaces during simulated office activities—e.g., paper handling, foot traffic, moving containers—after a period of no entry and no ventilation for several days (38). McCleery et al. (25) found that reaerosolization of spores is possible in postal facilities.In the mail-related instance of 2001, aerosol exposures occurred. Since spore-contaminated surfaces can become sources for aerosol generation, nonporous surfaces (walls, desks, lockers, etc.) were decontaminated to reduce risk while porous surfaces (draperies and sofas) were removed. To determine the efficacy of decontamination, contaminated buildings were first sampled for the presence of B. anthracis spores followed by treatment by a variety of techniques. Postdecontamination sampling was used to determine efficacy (37) and to assess the safety for reoccupancy.The Government Accountability Office (GAO) reported that additional methodological validation of sampling collection and analytical methods should be conducted to enhance the interpretation of negative sampling results because initial samples from two postal facilities were negative, but later samples were positive (17). The GAO (17) report defined validation as “… a formal and independently administered empirical process. For validation, the overall performance characteristics of a given method must be certified as meeting the specified requirements for intended use and as conforming with applicable standards.” Currently, there is no preexisting standard for a presumable safe level of surface contamination with B. anthracis spores that may be assessed through sampling and analysis.Development of independent standards for assessing the requirements for surface sampling methods requires an understanding of the rate at which spores leave surfaces to become entrained in aerosols, the potential for aerosol exposure by humans, and the infectivity of inhaled spores. Inhalation infectivity has been researched, but estimates of a lethal dose vary (14, 15). Bartrand et al. (5) conducted a risk analysis on the mortality of guinea pigs and rhesus monkeys exposed to B. anthracis spores and found a 50% lethal dose (LD50; i.e., the dose at which 50% of subjects die) of about 100,000 spores inhaled for 1-μm particles. Limitations of relating exposure to inhalation infectivity include quantification of the ability of spores to move from stasis on a surface to entrainment as an aerosol, quantification of exposures to the resultant aerosol, uptake by humans, room size and ventilation characteristics, and exposure time. Despite these limitations, it is necessary to standardize the performance of surface sampling methods.Brown et al. evaluated wipe (6), swab (7), and vacuum (8) spore collection methods with B. atrophaeus. These studies have added significant information to the understanding of recovery efficiencies for these three sampling methods; however, sampling performance was not evaluated at very low spore surface loading concentrations. Sampling performance measures at very low surface loading of B. anthracis are needed to aid in the decision making for decontamination and other interventions (31, 38).The goal of this study was to evaluate the current CDC environmental surface sampling methods for B. anthracis (12) as slightly modified based on subsequent CDC research (19, 30). We estimated B. anthracis Sterne sampling limit of detection (LOD), recovery efficiency (RE), and measurement precision for three sampling methods (swab, wipe, and vacuum) and two surfaces (steel and carpet) by allowing spores to settle from an aerosol in a controlled environment. In addition, we compared sample analyses performed at three laboratories to determine the level of interlaboratory variability.  相似文献   

12.
A comparison of Most-Probable-Number Rapid Viability (MPN RV) PCR and traditional culture methods for the quantification of Bacillus anthracis Sterne spores in macrofoam swabs from a multi-center validation study was performed. The purpose of the study was to compare environmental swab processing methods for recovery, detection, and quantification of viable B. anthracis spores from surfaces. Results show that spore numbers provided by the MPN RV-PCR method were typically within 1-log of the values from a plate count method for all three levels of spores tested (3.1 × 104, 400, and 40 spores sampled from surfaces with swabs) even in the presence of debris. The MPN method tended to overestimate the expected result, especially at lower spore levels. Blind negative samples were correctly identified using both methods showing a lack of cross contamination. In addition to detecting low levels of spores in environmental conditions, the MPN RV-PCR method is specific, and compatible with automated high-throughput sample processing and analysis protocols, enhancing its utility for characterization and clearance following a biothreat agent release.  相似文献   

13.
Methods for detecting microorganisms on surfaces are needed to locate biocontamination sources and to relate surface and airborne concentrations. Research was conducted in an experimental room to evaluate surface sampling methods and quantitative PCR (QPCR) for enhanced detection of a target biocontaminant present on flooring materials. QPCR and culture analyses were used to quantitate Bacillus subtilis (Bacillus globigii) endospores on vinyl tile, commercial carpet, and new and soiled residential carpet with samples obtained by four surface sampling methods: a swab kit, a sponge swipe, a cotton swab, and a bulk method. The initial data showed that greater overall sensitivity was obtained with the QPCR than with culture analysis; however, the QPCR results for bulk samples from residential carpet were negative. The swab kit and the sponge swipe methods were then tested with two levels of background biological contamination consisting of Penicillium chrysogenum spores. The B. subtilis values obtained by the QPCR method were greater than those obtained by culture analysis. The differences between the QPCR and culture data were significant for the samples obtained with the swab kit for all flooring materials except soiled residential carpet and with the sponge swipe for commercial carpet. The QPCR data showed that there were no significant differences between the swab kit and sponge swipe sampling methods for any of the flooring materials. Inhibition of QPCR due solely to biological contamination of flooring materials was not evident. However, some degree of inhibition was observed with the soiled residential carpet, which may have been caused by the presence of abiotic contaminants, alone or in combination with biological contaminants. The results of this research demonstrate the ability of QPCR to enhance detection and enumeration of biocontaminants on surface materials and provide information concerning the comparability of currently available surface sampling methods.  相似文献   

14.
The development of new value-added applications for glycerol is of worldwide interest because of the environmental and economic problems that may be caused by an excess of glycerol generated from biodiesel production. A novel use of glycerol as a major substrate for production of a low-cost sterilization biological indicator system (BIS; spores on a carrier plus a recovery medium) was investigated. A sequential experimental design strategy was applied for product development and optimization. The proposed recovery medium enables germination and outgrowth of heat-damaged spores, promoting a D 160 °C value of 6.6?±?0.1 min. Bacillus atrophaeus spores production by solid-state fermentation reached a 2.3?±?1.2?×?108?CFU/g dry matter. Sporulation kinetics results allowed this process to be restricted in 48 h. Germination kinetics demonstrated the visual identification of nonsterile BIS within 24 h. Performance evaluation of the proposed BIS against dry-heat and ethylene oxide sterilization showed compliance with the regulatory requirements. Cost breakdowns were from 41.8 (quality control) up to 72.8 % (feedstock). This is the first report on sterilization BIS production that uses glycerol as a sole carbon source, with significant cost reduction and the profitable use of a biodiesel byproduct.  相似文献   

15.
Evaluation of the fate and transport of biological warfare (BW) agents in landfills requires the development of specific and sensitive detection assays. The objective of the current study was to develop and validate SYBR green quantitative real-time PCR (Q-PCR) assays for the specific detection and quantification of surrogate BW agents in synthetic building debris (SBD) and leachate. Bacillus atrophaeus (vegetative cells and spores) and Serratia marcescens were used as surrogates for Bacillus anthracis (anthrax) and Yersinia pestis (plague), respectively. The targets for SYBR green Q-PCR assays were the 16S-23S rRNA intergenic transcribed spacer (ITS) region and recA gene for B. atrophaeus and the gyrB, wzm, and recA genes for S. marcescens. All assays showed high specificity when tested against 5 ng of closely related Bacillus and Serratia nontarget DNA from 21 organisms. Several spore lysis methods that include a combination of one or more of freeze-thaw cycles, chemical lysis, hot detergent treatment, bead beat homogenization, and sonication were evaluated. All methods tested showed similar threshold cycle values. The limit of detection of the developed Q-PCR assays was determined using DNA extracted from a pure bacterial culture and DNA extracted from sterile water, leachate, and SBD samples spiked with increasing quantities of surrogates. The limit of detection for B. atrophaeus genomic DNA using the ITS and B. atrophaeus recA Q-PCR assays was 7.5 fg per PCR. The limits of detection of S. marcescens genomic DNA using the gyrB, wzm, and S. marcescens recA Q-PCR assays were 7.5 fg, 75 fg, and 7.5 fg per PCR, respectively. Quantification of B. atrophaeus vegetative cells and spores was linear (R2 > 0.98) over a 7-log-unit dynamic range down to 101 B. atrophaeus cells or spores. Quantification of S. marcescens (R2 > 0.98) was linear over a 6-log-unit dynamic range down to 102 S. marcescens cells. The developed Q-PCR assays are highly specific and sensitive and can be used for monitoring the fate and transport of the BW surrogates B. atrophaeus and S. marcescens in building debris and leachate.  相似文献   

16.
Inanimate surfaces, or fomites, can serve as routes of transmission of enteric and respiratory pathogens. No previous studies have evaluated the impact of surface disinfection on the level of pathogen transfer from fomites to fingers. Thus, the present study investigated the change in microbial transfer from contaminated fomites to fingers following disinfecting wipe use. Escherichia coli (108 to 109 CFU/ml), Staphylococcus aureus (109 CFU/ml), Bacillus thuringiensis spores (107 to 108 CFU/ml), and poliovirus 1 (108 PFU/ml) were seeded on ceramic tile, laminate, and granite in 10-μl drops and allowed to dry for 30 min at a relative humidity of 15 to 32%. The seeded fomites were treated with a disinfectant wipe and allowed to dry for an additional 10 min. Fomite-to-finger transfer trials were conducted to measure concentrations of transferred microorganisms on the fingers after the disinfectant wipe intervention. The mean log10 reduction of the test microorganisms on fomites by the disinfectant wipe treatment varied from 1.9 to 5.0, depending on the microorganism and the fomite. Microbial transfer from disinfectant-wipe-treated fomites was lower (up to <0.1% on average) than from nontreated surfaces (up to 36.3% on average, reported in our previous study) for all types of microorganisms and fomites. This is the first study quantifying microbial transfer from contaminated fomites to fingers after the use of disinfectant wipe intervention. The data generated in the present study can be used in quantitative microbial risk assessment models to predict the effect of disinfectant wipes in reducing microbial exposure.  相似文献   

17.
An aerosol cloud of Bacillus atrophaeus (previously B. subtilis variety niger) spores, an anthrax surrogate, was created in a large 0.4 ha (1 ac), bee-containing, open-mesh tent. Bees from a B. atrophaeus uncontaminated hive flying through the cloud adsorbed the spores in statistically significant quantities. After removal of the B. atrophaeus contaminated hive and introduction of another B. atrophaeus uncontaminated hive, the bees again were monitored for the next few days for B. atrophaeus spores. B. atrophaeus spores accumulated on the bees bodies following their exposure to the residual B. atrophaeus contamination in the tent. The spore loads on the bees quickly returned to background levels after the hives were removed from the contaminated tent area. It may therefore be practical to use honey bee colonies to monitor foraging areas for disease-causing spores.  相似文献   

18.
An aerosol cloud of Bacillus atrophaeus (previously B. subtilis variety niger) spores, an anthrax surrogate, was created in a large 0.4 ha (1 ac), bee-containing, open-mesh tent. Bees from a B. atrophaeus uncontaminated hive flying through the cloud adsorbed the spores in statistically significant quantities. After removal of the B. atrophaeus contaminated hive and introduction of another B. atrophaeus uncontaminated hive, the bees again were monitored for the next few days for B. atrophaeus spores. B. atrophaeus spores accumulated on the bees bodies following their exposure to the residual B. atrophaeus contamination in the tent. The spore loads on the bees quickly returned to background levels after the hives were removed from the contaminated tent area. It may therefore be practical to use honey bee colonies to monitor foraging areas for disease-causing spores.  相似文献   

19.
Aims: To determine the wet and dry density of spores of Bacillus anthracis and compare these values with the densities of other Bacillus species grown and sporulated under similar conditions. Methods and Results: We prepared and studied spores from several Bacillus species, including four virulent and three attenuated strains of B. anthracis, two Bacillus species commonly used to simulate B. anthracis (Bacillus atrophaeus and Bacillus subtilis) and four close neighbours (Bacillus cereus, Bacillus megaterium, Bacillus thuringiensis and Bacillus stearothermophilus), using identical media, protocols and instruments. We determined the wet densities of all spores by measuring their buoyant density in gradients of Percoll and their dry density in gradients of two organic solvents, one of high and the other of low chemical density. The wet density of different strains of B. anthracis fell into two different groups. One group comprised strains of B. anthracis producing spores with densities between 1·162 and 1·165 g ml?1 and the other group included strains whose spores showed higher density values between 1·174 and 1·186 g ml?1. Both Bacillus atrophaeus and B. subtilis were denser than all the B. anthracis spores studied. Interestingly and in spite of the significant differences in wet density, the dry densities of all spore species and strains were similar. In addition, we correlated the spore density with spore volume derived from measurements made by electron microscopy analysis. There was a strong correlation (R2 = 0·95) between density and volume for the spores of all strains and species studied. Conclusions: The data presented here indicate that the two commonly used simulants of B. anthracis, B. atrophaeus and B. subtilis were considerably denser and smaller than all B. anthracis spores studied and hence, these simulants could behave aerodynamically different than B. anthracis. Bacillus thuringiensis had spore density and volume within the range observed for the various strains of B. anthracis. The clear correlation between wet density and volume of the B. anthracis spores suggest that mass differences among spore strains may be because of different amounts of water contained within wet dormant spores. Significance and Impact of the Study: Spores of nonvirulent Bacillus species are often used as simulants in the development and testing of countermeasures for biodefense against B. anthracis. The similarities and difference in density and volume that we found should assist in the selection of simulants that better resemble properties of B. anthracis and, thus more accurately represent the performance of countermeasures against this threat agent where spore density, size, volume, mass or related properties are relevant.  相似文献   

20.
A study of six child care centers was conducted to assess the microbiological quality of three food contact surfaces (one food serving surface and two food preparation surfaces) and one non-food contact surface (diaper changing surface) to determine the effectiveness of cleaning and sanitization procedures within the facilities. Aerobic plate counts (APCs) and Escherichia coli/coliform counts of 50-cm2 areas on all surfaces were determined using standard microbiological swabbing methods. Samples were taken three times a day (preopening, lunchtime, and following final cleanup) twice per month for 8 months in each child care center (n = 288 sampling times). Mean log APCs over the survey period were 1.32, 1.71, 1.34, 1.96, 1.50, and 1.81 log CFU/50 cm2 for the six centers. Mean log coliform counts were 0.15, 0.40, 0.33, 1.41, 0.28, and 1.12 CFU/50 cm2 for the same centers. Coliforms were detected in 283 of 1,149 (24.7%) samples, with counts ranging from 1 to 2,000 CFU/50 cm2, while E. coli was detected in 18 of 1,149 (1.6%) samples, with counts ranging from 1 to 35 CFU/50 cm2. The findings of this study demonstrated that the extent of bacterial contamination was dependent on the center, time of day, and the area sampled. While no direct correlation between contamination and illness can be made, given the high risk of food-borne illness associated with children, microbial contamination of food contact or non-food contact surfaces is an aspect of food safety that requires more attention. Emphasis on training and the development of modified standard sanitation operating procedures for child care centers are needed to reduce potential hazards.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号