首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We used a pin-on-disc tribometer to measure the friction coefficient of both pristine and mechanically damaged cartilage samples in the presence of different lubricant solutions. The experimental set up maximizes the lubrication mechanism due to interstitial fluid pressurization. In phosphate buffer solution (PBS), the measured friction coefficient increases with the level of damage. The main result is that when poly(ethylene oxide) (PEO) or hyaluronic acid (HA) are dissolved in PBS, or when synovial fluid (SF) is used as lubricant, the friction coefficients measured for damaged cartilage samples are only slightly larger than those obtained for pristine cartilage samples, indicating that the surface damage is in part alleviated by the presence of the various lubricants. Among the lubricants considered, 100 mg/mL of 100,000 Da MW PEO in PBS appears to be as effective as SF. We attempted to discriminate the lubrication mechanism enhanced by the various compounds. The lubricants viscosity was measured at shear rates comparable to those employed in the friction experiments, and a quartz crystal microbalance with dissipation monitoring was used to study the adsorption of PEO, HA, and SF components on collagen type II adlayers pre-formed on hydroxyapatite. Under the shear rates considered the viscosity of SF is slightly larger than that of PBS, but lower than that of lubricant formulations containing HA or PEO. Neither PEO nor HA showed strong adsorption on collagen adlayers, while evidence of adsorption was found for SF. Combined, these results suggest that synovial fluid is likely to enhance boundary lubrication. It is possible that all three formulations enhance lubrication via the interstitial fluid pressurization mechanism, maximized by the experimental set up adopted in our friction tests.  相似文献   

2.
Friction and wear are detrimental to engineered systems. Ultrasonic lubrication is achieved when the interface between two sliding surfaces is vibrated at a frequency above the acoustic range (20 kHz). As a solid-state technology, ultrasonic lubrication can be used where conventional lubricants are unfeasible or undesirable. Further, ultrasonic lubrication allows for electrical modulation of the effective friction coefficient between two sliding surfaces. This property enables adaptive systems that modify their frictional state and associated dynamic response as the operating conditions change. Surface wear can also be reduced through ultrasonic lubrication. We developed a protocol to investigate the dependence of friction force reduction and wear reduction on the linear sliding velocity between ultrasonically lubricated surfaces. A pin-on-disc tribometer was built which differs from commercial units in that a piezoelectric stack is used to vibrate the pin at 22 kHz normal to the rotating disc surface. Friction and wear metrics including effective friction force, volume loss, and surface roughness are measured without and with ultrasonic vibrations at a constant pressure of 1 to 4 MPa and three different sliding velocities: 20.3, 40.6, and 87 mm/sec. An optical profilometer is utilized to characterize the wear surfaces. The effective friction force is reduced by 62% at 20.3 mm/sec. Consistently with existing theories for ultrasonic lubrication, the percent reduction in friction force diminishes with increasing speed, down to 29% friction force reduction at 87 mm/sec. Wear reduction remains essentially constant (49%) at the three speeds considered.  相似文献   

3.
Lubrication mode analysis of articular cartilage using Stribeck surfaces   总被引:2,自引:0,他引:2  
Lubrication of articular cartilage occurs in distinct modes with various structural and biomolecular mechanisms contributing to the low-friction properties of natural joints. In order to elucidate relative contributions of these factors in normal and diseased tissues, determination and control of lubrication mode must occur. The objectives of these studies were (1) to develop an in vitro cartilage on glass test system to measure friction coefficient, mu; (2) to implement and extend a framework for the determination of cartilage lubrication modes; and (3) to determine the effects of synovial fluid on mu and lubrication mode transitions. Patellofemoral groove cartilage was linearly oscillated against glass under varying magnitudes of compressive strain utilizing phosphate buffered saline (PBS) and equine and bovine synovial fluid as lubricants. The time-dependent frictional properties were measured to determine the lubricant type and strain magnitude dependence for the initial friction coefficient (mu(0)=mu(t-->0)) and equilibrium friction coefficient (mu(eq)=mu(t-->infinity)). Parameters including tissue-glass co-planarity, normal strain, and surface speed were altered to determine the effect of the parameters on lubrication mode via a 'Stribeck surface'. Using this testing apparatus, cartilage exhibited biphasic lubrication with significant influence of strain magnitude on mu(0) and minimal influence on mu(eq), consistent with hydrostatic pressurization as reported by others. Lubrication analysis using 'Stribeck surfaces' demonstrated clear regions of boundary and mixed modes, but hydrodynamic or full film lubrication was not observed even at the highest speed (50mm/s) and lowest strain (5%).  相似文献   

4.
Prediction of lubricating film thickness in UHMWPE hip joint replacements   总被引:4,自引:0,他引:4  
An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. It has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. It should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed.  相似文献   

5.
Ultra High Molecular Weight Polyethylene(UHMWPE)has been widely used as a bearing material for artificial joint replacementover forty years.It is usually crosslinked by gamma rays irradiation before its implantation into human body.In thisstudy,UHMWPE and UHMWPE/nano-hydroxyapatite(n-HA)composite were prepared by vacuum hot-pressing method.Theprepared materials were irradiated by gamma rays in vacuum and molten heat treated in vacuum just after irradiation.The effectof filling n-HA with gamma irradiation on tribological properties of UHMWPE was investigated by using friction and wearexperimental machine(model MM-200)under deionized water lubrication.Micro-morphology of worn surface was observedby metallographic microscope.Contact angle and hardness of the materials were also measured.The results show that contactangle and hardness are changed by filling n-HA and gamma irradiation.Friction coefficient and wear rate under deionized waterlubrication are reduced by filling n-HA.While friction coefficient is increased and wear rate is reduced significantly by gammairradiation.The worn surface of unfilled material is mainly characterized as adhesive wear and abrasive wear,and that of n-HAfilled material is mainly characterized as abrasive wear.After gamma irradiation,the degrees of adhesive and abrasive wear forunfilled material and abrasive wear of n-HA filled material are significantly reduced.Unfilled and filled materials after irradiationare mainly shown as slight fatigue wear.The results indicate that UHMWPE and UHMWPE/n-HA irradiated at the doseof 150 kGy can be used as bearing materials in artificial joints for its excellent wear resistance compared to original UHMWPE.  相似文献   

6.
The surface behavior of aqueous solutions of fibrinogen, transferrin, gamma-globulin and albumin at the liquid-gas interface has been investigated by a modified Wilhelmy technique. The temperature dependence of the surface tension was studied over a temperature range of 20--80 degrees C and a pH range of 2--12. Most pronounced conformational changes of fibrinogen with this technique were found in physiological conditions: 35--45 degrees C and pH 7--8. A conformational change was found for gamma-globulin and transferrin solutions, but at a higher temperature and less pronounced than fibrinogen. Albumin did not undergo conformational transitions to a significant extent.  相似文献   

7.
Molecular weights and translational diffusion coefficients have been measured for rooster comb and vitreous hyaluronic acid (HA) at pH 7.2 and 11. The results indicate that the molecular weight, second virial coefficient and translational diffusion coefficient for vitreous HA can be reversibly decreased by increasing the solution pH from 7.2 to 11, whereas the physical properties of rooster comb HA are independent of pH studied. In addition, it is reported that the second virial coefficient for vitreous HA is negative, suggesting intermolecular interactions exist in solution at both neutral and alkaline pH as opposed to rooster comb HA which exhibits a positive second vitrial coefficient associated with decreasing molecular weights may be related to the accessibility and number of hydrogen bond forming groups. Differences in the dependence of molecular weight on pH between vitreous and rooster comb HA may be due to differences in the number of intramolecular interactions per molecule. These studies indicate that molecules of low molecular weight HA are able to form higher molecular weight complexes and differences in the organization of the polysaccharide chains may contribute to the differences in molecular weight of HAs isolated from various tissues.  相似文献   

8.
Mammalian synovial joints are extremely efficient lubrication systems reaching friction coefficient μ as low as 0.001 at high pressures (up to 100 atm) and shear rates (up to 10(6) to 10(7) Hz); however, despite much previous work, the exact mechanism responsible for this behavior is still unknown. In this work, we study the molecular mechanism of synovial joint lubrication by emulating the articular cartilage superficial zone structure. Macromolecules extracted and purified from bovine hip joints using well-known biochemical techniques and characterized with atomic force microscope (AFM) have been used to reconstruct a hyaluronan (HA)--aggrecan layer on the surface of molecularly smooth mica. Aggrecan forms, with the help of link protein, supramolecular complexes with the surface-attached HA similar to those at the cartilage/synovial fluid interface. Using a surface force balance (SFB), normal and shear interactions between a HA--aggrecan-coated mica surface and bare mica have been examined, focusing, in particular, on the frictional forces. In each stage, control studies have been performed to ensure careful monitoring of the macromolecular surface layers. We found the aggrecan--HA complex to be a much better boundary lubricant than the HA alone, an effect attributed largely to the fluid hydration sheath bound to the highly charged glycosaminoglycan (GAG) segments on the aggrecan core protein. A semiquantitative model of the osmotic pressure is used to describe the normal force profiles between the surfaces and interpret the boundary lubrication mechanism of such layers.  相似文献   

9.
Liu L  Du G  Chen J  Zhu Y  Wang M  Sun J 《Bioresource technology》2009,100(1):362-367
Microbial production of low molecular weight hyaluronic acid (HA) by the addition of hydrogen peroxide and ascorbate during the batch culture of Streptococcus zooepidemicus was investigated. Hydrogen peroxide (1.0 mmol/g HA) and ascorbate (0.5 mmol/g HA) were added at 8h and 12h to degrade HA. With the redox depolymerization of HA, the HA molecular weight decreased from 1,300 kDa for the control to 80 kDa, and the average broth viscosity during 8-16 h decreased from 360 mPa s for the control to 290 mPa s. The average oxygen mass transfer coefficient K(L)a increased from 10h(-1) for the control to 35 h(-1) and the average dissolved oxygen level increased from 1% of air saturation in the control to 10%. HA production increased from 5.0 g/L for the control to 6.5 g/L, and contributed to the increased redox potential and energy charge. This novel process not only significantly enhanced production of low molecular weight HA, but also improved purification efficiency due to a decreased broth viscosity. Low molecular weight HA finds applications in biomedical and healthcare fields.  相似文献   

10.
Hyaluronan (HA) hydrolysis catalyzed by hyaluronidase (HAase) is inhibited at low HAase over HA ratio and low ionic strength, because HA forms electrostatic complexes with HAase, which is unable to catalyze hydrolysis. Bovine serum albumin (BSA) was used as a model to study the HA-protein electrostatic complexes at pH 4. At low ionic strength, there is formation of (i) neutral insoluble complexes at the phase separation and (ii) small positively-charged or large negatively-charged soluble complexes whether BSA or HA is in excess. According to the ionic strength, different types of complex are formed. Assays for HA and BSA led to the determination of the stoichiometry of these complexes. HAase was also shown to form the various types of complex with HA at low ionic strength. Finally, we showed that at 0 and 150 mmol L(-1) NaCl, BSA competes with HAase in forming complexes with HA and thus induces HAase release resulting in a large increase in the hydrolysis rate. These results, in addition to data in the literature, show that HA-protein complexes, which can exist under numerous and varied conditions of pH, ionic strength and protein over HA ratio, might control the in vivo HAase activity.  相似文献   

11.
The dielectric features of poly(L -glutamic acid) are studied by the Fourier synthesized pseudorandom noise method in a time domain combined with a four-electrode cell. Polymer concentration dependence, the effect of the solvent viscosity, salt effects, and pH dependence are studied concomitantly with measurements of CD. A helix-to-coil transition occurs near pH 5.6 for a salt-free solution; at higher pH values, the polymer has an ionized random-coil conformation, and at lower pH, it has a deionized α-helical conformation. When it is in the ionized random-coil conformation, with the usual features of an electrolytic polymer, the solution shows a relaxation spectrum with a large dielectric increment at low frequencies. In the deionized α-helical state, no distinct relaxation curves are obtained, which does not deny the existence of a permanent peptide dipole. The pH dependence of the dielectric increment does not mainly correspond to the conformational change from helix to coil, but rather corresponds to the change of chain expansion on account of a charge–charge interaction under low ionic strength, which is conceived of by a viscosity measurement.  相似文献   

12.
This study focuses on the transformation of energy in multilinkage systems by a deliberate use of the contact with the ground, leading to a derivation of the directional change of translational velocity of the body's center of mass. The coefficient of friction on the surface on which the impact occurs, and its effect on the overall movement, is studied for general multilinkage systems undergoing impact. The effect of surface friction is made apparent via simulation studies for a two-link example, where two interesting conditions arise: slippage or no slippage on the surface at impact. It is found that once the system stops on the surface, the translational energy increases as the angular velocity increases. Likewise, it is seen that the rotational energy after impact increases as the angular velocity of the first link increases, but the rate of increase of energy is less in the case where the system stops on the ground with no slippage.  相似文献   

13.
This paper presents the results of viscosity determinations on aqueous solutions of equine, porcine and rabbit serum albumin over a wide range of concentrations and at temperatures ranging from 5 degrees C to (42-45) degrees C. The results are compared with human and bovine serum albumin previously studied. Viscosity-temperature dependence is discussed on the basis of the modified Arrhenius formula. The effective specific volume, the activation energy and entropy of viscous flow for all investigated albumins are compared. Viscosity-concentration dependence, in turn, is discussed on the basis of Mooney equation. Based on the assumption that theoretical and experimental values of Simha factor--at high temperature limit--are equal to each other, the hydrodynamic volume of the studied albumins has been calculated. The numerical values of a self-crowding factor were also obtained. At low concentration limit, the numerical values of the intrinsic viscosity and of Huggins coefficient were compared.  相似文献   

14.
In this work, a single tablet model and a discrete element method (DEM) computer simulation are developed to obtain the angular circulation speed of tablets in a vibratory tablet coating pan for range of vibration frequencies and amplitudes. The models identify three important dimensionless parameters that influence the speed of the tablets: the dimensionless amplitude ratio (a/R), the Froude number ( 2/g), and the tablet–wall friction coefficient, where a is the peak vibration amplitude at the drum center, ω is the vibration angular frequency, R is the drum radius, and g is the acceleration due to gravity. The models predict that the angular circulation speed of tablets increases with an increase in each of these parameters. The rate of increase in the angular circulation speed is observed to decrease for larger values of a/R. The angular circulation speed reaches an asymptote beyond a tablet–wall friction coefficient value of about 0.4. Furthermore, it is found that the Froude number should be greater than one for the tablets to start circulating. The angular circulation speed increases as Froude number increases but then does not change significantly at larger values of the Froude number. Period doubling, where the motion of the bed is repeated every two cycles, occurs at a Froude number larger than five. The single tablet model, although much simpler than the DEM model, is able to predict the maximum circulation speed (the limiting case for a large value of tablet–wall friction coefficient) as well as the transition to period doubling.  相似文献   

15.
Boundary lubrication of articular cartilage by conformal, molecularly thin films reduces friction and adhesion between asperities at the cartilage-cartilage contact interface when the contact conditions are not conducive to fluid film lubrication. In this study, the nanoscale friction and adhesion properties of articular cartilage from typical load-bearing and non-load-bearing joint regions were studied in the boundary lubrication regime under a range of physiological contact pressures using an atomic force microscope (AFM). Adhesion of load-bearing cartilage was found to be much lower than that of non-load-bearing cartilage. In addition, load-bearing cartilage demonstrated steady and low friction coefficient through the entire load range examined, whereas non-load-bearing cartilage showed higher friction coefficient that decreased nonlinearly with increasing normal load. AFM imaging and roughness calculations indicated that the above trends in the nanotribological properties of cartilage are not due to topographical (roughness) differences. However, immunohistochemistry revealed consistently higher surface concentration of boundary lubricant at load-bearing joint regions. The results of this study suggest that under contact conditions leading to joint starvation from fluid lubrication, the higher content of boundary lubricant at load-bearing cartilage sites preserves synovial joint function by minimizing adhesion and wear at asperity microcontacts, which are precursors for tissue degeneration.  相似文献   

16.
Although post-traumatic osteoarthritis accounts for a significant proportion of all osteoarthritis, the understanding of both biological and mechanical phenomena that lead to cartilage degeneration in the years to decades after trauma is still lacking. In this study, we evaluate how cartilage lubrication is altered after a sub-critical impact (i.e., an impact to the cartilage surface that produces surface cracking but not full thickness fissuring). Through utilizing a Stribeck-like framework, the elastoviscous transition, we evaluated changes to both the innate boundary lubricating ability of cartilage after impact and also the effectiveness of high viscosity lubricants to lower friction after impact. Increases in boundary friction coincided with changes in lubricin localization after impact. However, larger increases in friction coefficient were observed in mixed-mode lubrication which can be predicted by increases in surface roughness due to cartilage fissuring. The data here reveal distinct mechanisms of cartilage lubrication that can fail after traumatic impact and may explain a key mechanical phenomenon that predisposes cartilage to development of osteoarthritis after injury.  相似文献   

17.
Elastohydrodynamic lubrication (EHL) protects soft tissues from damage and wear in many biological systems (e.g. synovial joints, cornea of the eye, and pleural surfaces of the lung and chest wall). Among studies of lubrication of deformable solids, few have examined the effects of external loads, geometry, and material properties on EHL of soft tissues. To examine these effects, we studied the tribology of soft tissues in a two-dimensional finite element simulation of a thin layer of fluid separating a sliding rigid surface from a soft asperity or bump with an initial sinusoidal shape. We computed the frictional force, deformation of the solid, and change in fluid thickness as functions of independent variables: sliding velocity, normal load, material properties, and bump amplitude and length. Double-logarithmic regression was used to determine the exponents of the scaling relationships of friction coefficient and minimum fluid thickness to the independent variables. The analysis showed that frictional shear force is strongly dependent on velocity, viscosity, and load, moderately dependent on bump length and elasticity, and only weakly dependent on the bump amplitude. The minimum fluid thickness is strongly dependent on velocity and viscosity, and changes moderately with load, elasticity, amplitude, and length. The shape of the bump has little effect. The results confirm that the shear-induced deformation of an initially symmetrical shape, including generalizations to other symmetrical geometries such as quadratic or piecewise linear bumps, leads to load-supporting behavior.  相似文献   

18.
Manoeuverability is a key requirement for successful terrestrial locomotion, especially on variable terrain, and is a deciding factor in predator-prey interaction. Compared with straight-line running, bend running requires additional leg force to generate centripetal acceleration. In humans, this results in a reduction in maximum speed during bend running and a published model assuming maximum limb force as a constraint accurately predicts how much a sprinter must slow down on a bend given his maximum straight-line speed. In contrast, greyhounds do not slow down or change stride parameters during bend running, which suggests that their limbs can apply the additional force for this manoeuvre. We collected horizontal speed and angular velocity of heading of horses while they turned in different scenarios during competitive polo and horse racing. The data were used to evaluate the limits of turning performance. During high-speed turns of large radius horizontal speed was lower on the bend, as would be predicted from a model assuming a limb force limit to running speed. During small radius turns the angular velocity of heading decreased with increasing speed in a manner consistent with the coefficient of friction of the hoof-surface interaction setting the limit to centripetal force to avoid slipping.  相似文献   

19.
This paper investigates the effect of thermal radiation on unsteady convection flow and heat transfer over a vertical permeable stretching surface in porous medium, where the effects of temperature dependent viscosity and thermal conductivity are also considered. By using a similarity transformation, the governing time-dependent boundary layer equations for momentum and thermal energy are first transformed into coupled, non-linear ordinary differential equations with variable coefficients. Numerical solutions to these equations subject to appropriate boundary conditions are obtained by the numerical shooting technique with fourth-fifth order Runge-Kutta scheme. Numerical results show that as viscosity variation parameter increases both the absolute value of the surface friction coefficient and the absolute value of the surface temperature gradient increase whereas the temperature decreases slightly. With the increase of viscosity variation parameter, the velocity decreases near the sheet surface but increases far away from the surface of the sheet in the boundary layer. The increase in permeability parameter leads to the decrease in both the temperature and the absolute value of the surface friction coefficient, and the increase in both the velocity and the absolute value of the surface temperature gradient.  相似文献   

20.
为了探讨电子束辐照对透明质酸功能及结构特性的影响,选择5、10、20、40、80 、100和150 kGy的电子束辐照固体透明质酸,测定透明质酸辐照前后分子量、特性粘度 、pH值、抗氧化性、紫外光谱、红外光谱、电镜图片的变化.结果表明,辐照降低透明 质酸的分子量、特性粘度、pH值;透明质酸在辐照前后的吸收特征峰没有显著的改变, 吸收强度增强;透明质酸形状随着辐照剂量的升高,由块状逐渐变成颗粒状;透明质酸 对DPPH·自由基的清除作用和还原力随着辐照剂量的增大逐渐增强.电子束辐照对透明 质酸分子结构和功能有一定的影响,但对其一级结构没有影响.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号