首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A rapid and sensitive electrospray ionization (ESI) tandem mass spectrometry (MS–MS) procedure was developed for the determination of iodide (I). A gold (Au) and I complex was formed immediately after the addition of the chelating agent NaAuCl4 to I solution, and was extracted with methyl isobutyl ketone. One to five microliters of the extract were injected directly into an ESI–MS–MS instrument. I quantification was performed by selecting reaction monitoring of the product ion I at m/z 127 derived from the precursor ion 197AuI2 at m/z 451. I concentration was measured in the quantification range from 10−7 to 10−5 M using 50 μL of solution within 10 min. Iodate was reduced to I with ascorbic acid and determined. I concentration in reference urine 2670a was measured after treatments.  相似文献   

2.
Advances in mass spectrometry have facilitated the identification of novel lipid structures. In this work, we fractionated the lipids of Escherichia coli B and analyzed the fractions using negative-ion electrospray ionization mass spectrometry to reveal unknown lipid structures. Analysis of a fraction eluting with high salt from DEAE cellulose revealed a series of ions not corresponding to any of the known lipids of E. coli. The ions, with m/z 861.5, 875.5, 887.5, 889.5, and 915.5, were analyzed using collision-induced dissociation mass spectrometry (MS/MS) and yielded related fragmentation patterns consistent with a novel diacylated glycerophospholipid. Product ions arising by neutral loss of 216 mass units were observed with all of the unknowns. A corresponding negative product ion was also observed at m/z 215.0. Additional ions at m/z 197.0, 171.0, 146.0, and 128.0 were used to propose the novel structure phosphatidylserylglutamate (PSE). The hypothesized structure was confirmed by comparison with the MS/MS spectrum of a synthetic standard. Normal phase liquid chromatography-mass spectrometry analysis further showed that the endogenous PSE and synthetic PSE eluted with the same retention times. PSE was also observed in the equivalent anion exchange fractions of total lipids extracted from the wild-type E. coli K-12 strain MG1655.  相似文献   

3.
An original method based upon high-performance liquid chromatography coupled to electrospray ionization mass spectrometry has been developed for corticosterone (B) quantification in human serum. After extraction by diethyl ether using triamcinolone (T) as an internal standard, solutes are separated on a C18 microbore column (250×1.0 mm, I.D.), using acetonitrile–water–formic acid (40:59.9:0.1, v/v/v) as the mobile phase (flow-rate 40 μl/min). Detection is performed on an API 1 single quadrupole mass spectrometer equipped with a ESI interface and operated in positive ionization mode. Corticosterone quantifications were realized by computing peak area ratios (B/T) of the serum extracts analyzed in SIM mode (m/z 347 and m/z 395 for B and T, respectively), and comparing them with the calibration curve (r=0.998).  相似文献   

4.
Saturated branched chain fatty acids (BCFA) are present as complex mixtures in numerous biological samples. The traditional method for structure elucidation, electron ionization (EI) mass spectrometry, sometimes does not unambiguously enable assignment of branching in isomeric BCFA. Zirrolli and Murphy (Zirrolli , J. A. , and R. A. Murphy. 1993. Low-energy tandem mass spectrometry of the molecular ion derived from fatty acid methyl esters: a novel method for analysis of branched-chain fatty acids. J. Am. Soc. Mass Spectrom. 4: 223–229.) showed that the molecular ions of four BCFA methyl ester (BCFAME) yield highly characteristic fragments upon collisional dissociation using a triple quadrupole instrument. Here, we confirm and extend these results by analysis using a tabletop 3-D ion trap for activated molecular ion EI-MS/MS to 30 BCFAME. iso-BCFAME produces a prominent ion (30-100% of base peak) for [M-43] (M-C3H7), corresponding to the terminal isopropyl moiety in the original iso-BCFAME. Anteiso-FAME yield prominent ions (20-100% of base peak) corresponding to losses on both side of the methyl branch, [M-29] and [M-57], and tend to produce more prominent m/z 115 peaks corresponding to a cyclization product around the ester. Dimethyl and tetramethyl FAME, with branches separated by at least one methylene group, yield fragment on both sides of the sites of methyl branches that are more than 6 C away from the carboxyl carbon. EI-MS/MS yields uniquely specific ions that enable highly confident structural identification and quantification of BCFAME.  相似文献   

5.
A simple offline LC–MS/MS method for the quantification of sitagliptin in human plasma is described. Samples are prepared using protein precipitation. Filtration of the supernatants through a Hybrid-SPE-PPT plate was found to be necessary to reduce ionization suppression caused by co-elution of phospholipids with sitagliptin. The sitagliptin and its stable isotope labeled internal standard (IS) were chromatographed under hydrophilic interaction chromatography conditions on a Waters Atlantis HILIC Silica column (2.1 mm × 50 mm, 3 μm) using a mobile phase of ACN/H2O (80/20, v/v) containing 10 mM NH4Ac (pH 4.7). The sample drying after protein precipitation due to high organic content in the sample is not necessary, because HILIC column was used. The analytes were detected with a tandem mass spectrometer employing a turbo ion spray (TIS) interface in positive ionization mode. The multiple reaction monitoring (MRM) transitions were m/z 408 → 235 for sitagliptin and m/z 412 → 239 for IS. The lower limit of quantitation (LLOQ) for this method is 1 ng/mL when 100 μL of plasma is processed. The linear calibration range is 1–1000 ng/mL for sitagliptin. Intra-day precision and accuracy were assessed based on the analysis of six sets of calibration standards prepared in six lots of human control plasma. Intra-day precision (RSD%, n = 6) ranged from 1.2% to 6.1% and the intra-day accuracy ranged from 97.6% to 103% of nominal values.  相似文献   

6.
Energy-dependent electrospray ionization mass spectrometry (EDESI-MS) technique has been used for investigating the fragmentation of monomeric metal carbonyl complexes of general formula [M(CO)x(COOMe)] (M = Cr, Fe, Mo, and W). The results show that in addition to the loss of CO, formaldehyde loss provides a pathway of fragmentation. Of all complexes investigated, the chromium complex exhibits the cleanest fragmentation. At very high voltages, the metal ions is either associated with a hydride or a methoxide ions.  相似文献   

7.
The ability to examine real-time reaction kinetics for multimeric enzymes in their native state may offer unique insights into understanding the catalytic mechanism and its interplay with three-dimensional structure. In this study, we have used a time-resolved electrospray mass spectrometry approach to probe the kinetic mechanism of 4-hydroxybenzoyl-coenzyme A (4-HBA-CoA) thioesterase from Arthrobacter sp. strain SU in the millisecond time domain. Intact tetrameric complexes of 4-HBA-CoA thioesterase with up to four natural substrate (4-HBA-CoA) molecules bound were detected at times as early as 6 ms using an online rapid-mixing device directly coupled to an electrospray ionization time-of-flight mass spectrometer. Species corresponding to the formation of a folded tetramer of the thioesterase at charge states 16+, 17+, 18+, and 19+ around m/z 3800 were observed and assigned as individual tetramers of thioesterase and noncovalent complexes of the tetramers with up to four substrate and/or product molecules. Real-time evaluation of the reaction kinetics was accomplished by monitoring change in peak intensity corresponding to the substrate and product complexes of the tetrameric protein. The mass spectral data suggest that product 4-HBA is released from the active site of the enzyme prior to the release of product CoA following catalytic turnover. This study demonstrates the utility of this technique to provide additional molecular details for an understanding of the individual enzyme states during the thioesterase catalysis and ability to observe real-time interactions between enzyme and substrates and/or products in the millisecond time range.  相似文献   

8.
In high-throughput screening of gene and mutant libraries, high analysis speeds and short method development times are important factors. Mass spectrometry (MS) is considered to be a generic analytical technique with a relatively short development time. Furthermore, when applying flow injection analysis (FIA) for sample introduction, the requirements for high throughput are met. In this work, the use of a single quadrupole electrospray MS instrument for assaying amidase activity in a gene library is demonstrated. The desired selectivity for measuring the amino acid, the reaction product of the amidase reaction, in the presence of high concentrations of the corresponding amino acid amide substrate was obtained by selective ionization of the amino acid in negative ion mode electrospray. The only sample preparation required was a 200-fold dilution of the reaction mixture. For obtaining quantitative results, a complementary calibration procedure was set up to correct for the change in ionization suppression as a function of conversion. This approach was used to screen a Mycobacterium neoaurum gene library consisting of 11,520 clones with α-methylleucine amide as substrate within 24 h. Conversion was measured on the [M−H] species of the corresponding α-methylleucine (m/z 144). Five positive clones were detected with a conversion ranging from 0.2% to 3.4%.  相似文献   

9.
Mass spectrometers equipped with matrix‐assisted laser desorption/ionization (MALDI‐MS) require frequent multipoint calibration to obtain good mass accuracy over a wide mass range and across large numbers of samples. In this study, we introduce a new synthetic peptide mass calibration standard termed PAS‐cal tailored for MALDI‐MS based bottom‐up proteomics. This standard consists of 30 peptides between 8 and 37 amino acids long and each constructed to contain repetitive sequences of Pro, Ala and Ser as well as one C‐terminal arginine residue. MALDI spectra thus cover a mass range between 750 and 3200 m/z in MS mode and between 100 and 3200 m/z in MS/MS mode. Our results show that multipoint calibration of MS spectra using PAS‐cal peptides compares well to current commercial reagents for protein identification by PMF. Calibration of tandem mass spectra from LC‐MALDI experiments using the longest peptide, PAS‐cal37, resulted in smaller fragment ion mass errors, more matching fragment ions and more protein and peptide identifications compared to commercial standards, making the PAS‐cal standard generically useful for bottom‐up proteomics.  相似文献   

10.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   

11.
The procedure for the expression and purification of recombinant porcine leukocyte 12-lipoxygenase using Escherichia coli [K.M. Richards, L.J. Marnett, Biochemistry 36 (1997) 6692-6699] was updated to make it possible to produce enough protein for physical measurements. Electrospray ionization tandem mass spectrometry confirmed the amino acid sequence. The redox properties of the cofactor iron site were examined by EPR spectroscopy at 25 K following treatment with a variety of fatty acid hydroperoxides. Combination of the enzyme in a stoichiometric ratio with the hydroperoxides led to a g4.3 signal in EPR spectra instead of the g6 signal characteristic of similarly treated soybean lipoxygenase-1. Native 12-lipoxygenase was also subjected to electrospray ionization mass spectrometry. There was evidence for loss of the mass of an iron atom from the protein as the pH was lowered from 5 to 4. Native ions in these samples indicated that iron was lost without the protein completely unfolding.  相似文献   

12.
Laser desorption/ionization mass spectrometry (MS) is rapidly growing in popularity as an analytical characterization method in several fields. The technique shot to prominence using matrix-assisted desorption/ionization for large biomolecules (>700 Da), such as proteins, peptides and nucleic acids. However, because the matrix, which consists of small organic molecules, is also ionized, the technique is of limited use in the low-molecular-mass range (<700 Da). Recent advances in surface science have facilitated the development of matrix-free laser desorption/ionization MS approaches, which are referred to here as surface-assisted laser desorption/ionization (SALDI) MS. In contrast to traditional matrix-assisted techniques, the materials used for SALDI-MS are not ionized, which expands the usefulness of this technique to small-molecule analyses. This review discusses the current status of SALDI-MS as a standard analytical technique, with an emphasis on potential applications in proteomics.  相似文献   

13.
Succinoglycan monomers (M1, M2, and M3) are octasaccharides with acetyl, pyruvyl, and/or succinyl groups as substituents derived from Sinorhizobium meliloti 1021. The dissociation patterns of the octasaccharides caused by low-energy collision-activated dissociation (CAD) were investigated using triple quadrupole tandem mass spectrometry (MS) equipped with an electrospray ionization (ESI) source with increasing collision energy (CE) in negative ion mode. None of the succinoglycan monomers were fragmented at a CE of −25 eV. When the CE was applied to −50 or −70 eV, the loss of the terminal Gal residue and/or the succinyl group of the monomers was observed in the product ion scan mode. Interestingly, the acetyl and the pyruvyl groups in the succinoglycan monomers were not lost even when a CE of −70 eV was applied, indicating that the substituents are more stable than the succinyl group in the octasaccharides.  相似文献   

14.
Bendiak B  Fang TT 《Carbohydrate research》2010,345(16):2390-2400
Using mass spectrometry in the negative ion mode, m/z 221 ions are frequently observed as product ion substructures derived from reducing disaccharides having 2, 4, or 6 linkages. The ions have been shown to be glycosyl-glycolaldehydes. All 16 stereochemical variants of their pyranosides were prepared and evaluated by infrared photodissociation, in addition to HexNAc-glycolaldehyde variants (m/z 262) of 2-acetamido-2-deoxy-d-glucose and 2-acetamido-2-deoxy-d-galactose. The stereochemistry and anomeric configuration of these ions were differentiated in the gas phase using a Fourier transform ion cyclotron resonance spectrometer with infrared multiphoton dissociation at 10.6 μm. Results were compared to those obtained by collision-induced dissociation. In some cases, differentiation was far preferable using infrared photodissociation; in others, collision-induced dissociation was preferred. Using an instrument that interfaced a linear trap with a Fourier transform ion cyclotron resonance spectrometer, either dissociation technique could be used to optimally discriminate between isomers. With infrared photodissociation, spectral differences were highly statistically significant, even between pairs of isomers having spectra that appeared to be visually somewhat similar (<1 × 10−9, student’s t-test for key discriminatory ions). Comparisons among different instruments suggest that physical standards of the stereochemical variants of these ions will be required for their detailed structural assignments in unknowns, as some variation was observed among instruments, both using infrared photodissociation and collision-induced dissociation.  相似文献   

15.
Laser desorption/ionization mass spectrometry (MS) is rapidly growing in popularity as an analytical characterization method in several fields. The technique shot to prominence using matrix-assisted desorption/ionization for large biomolecules (>700 Da), such as proteins, peptides and nucleic acids. However, because the matrix, which consists of small organic molecules, is also ionized, the technique is of limited use in the low-molecular-mass range (<700 Da). Recent advances in surface science have facilitated the development of matrix-free laser desorption/ionization MS approaches, which are referred to here as surface-assisted laser desorption/ionization (SALDI) MS. In contrast to traditional matrix-assisted techniques, the materials used for SALDI-MS are not ionized, which expands the usefulness of this technique to small-molecule analyses. This review discusses the current status of SALDI-MS as a standard analytical technique, with an emphasis on potential applications in proteomics.  相似文献   

16.
Because of the recognized inaccuracy and unreliability of currently available methods for the quantification of histamine in biological fluids, a method for quantification of urinary histamine by stable isotope dilution assay with negative ion chemical ionization mass spectrometry has been developed. Following the addition of [2H4]histamine to 1 ml of urine, histamine is extracted into butanol, back-extracted into HCl, derivatized to the pentafluorobenzyl derivative (CH2C6F5)3-histamine, extracted into methylene chloride, and then quantified with negative ion chemical ionization mass spectrometry by selected ion monitoring of the ratio of ions mz430434. Twenty samples can be assayed in 2 days. Precision of the assay is ±2.7% and the accuracy is 97.6%. Lower limits of sensitivity are approximately 100–500 fg injected on-column. This assay provides a very sensitive, accurate, and efficient method for the quantification of histamine in human urine.  相似文献   

17.
A sensitive, specific, and rapid liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for analysis of lasiodonin, oridonin, ponicidin, and rabdoternin A in rat plasma using sulfamethoxazole as an internal standard (IS). The plasma samples were pretreated and extracted by liquid-liquid extraction. Chromatographic separation was performed on a C18 column with linear gradient elution using water and methanol, both of which were acidified with 0.1% aqueous formic acid, at a flow rate of 0.8 ml/min. Detection was accomplished by scanning with multiple reaction monitoring (MRM) via an electrospray ionization (ESI) source. Higher sensitivity was achieved by setting three scanning periods in a novel detection mode. The optimized mass transition ion pairs (m/z) for quantitation were 365.3/347.3 for lasiodonin and oridonin, 361.2/343.2 for ponicidin, 363.2/283.1 for rabdoternin A, and 254.1/156.0 for IS. The total run time was 13.50 min between injections. The specificity, linearity, accuracy, precision, recovery, matrix effect, and several stabilities were validated for all analytes in the rat plasma samples. In conclusion, the validation results demonstrate that this method is robust and specific. The proposed method was further applied to investigate the pharmacokinetics of all analytes after a single oral administration of Isodon rubescens extract to rats.  相似文献   

18.
ABSTRACT

Introduction: Paper spray mass spectrometry has provided a rapid, quantitative ambient ionization method for xenobiotic and biomolecule analysis. As an alternative to traditional sample preparation and chromatography, paper spray demonstrates the sampling ionization of a wide range of molecules and significant sensitivity from complex biofluids. The amenability of paper spray with dried blood spots and other sampling types shows strong potential for rapid, point-of-care (POC) analysis without time-consuming separation procedures.

Areas covered: This special report summarizes the current state and advances in paper spray mass spectrometry that relate to its applicability for clinical analysis. It also provides our perspectives on the future development of paper spray mass spectrometry and its potential roles in clinical settings.

Expert commentary: Paper spray has provided the fundamental aspects of ambient ionization needed for implementation at the POC. With further clinical management and standardization, paper spray has the potential to replace traditional complex analysis procedure for rapid quantitative detection of illicit drugs, therapeutic drugs and metabolites. Surface and substrate modifications also offer significant improvement in desorption and ionization efficiencies, resulting in enhanced sensitivity. Comprehensive analysis of metabolites and lipids will further extend the implementation of paper spray ionization mass spectrometry into clinical applications.  相似文献   

19.
A novel linear ion trap (LIT) mass spectrometer with dual matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) ionization sources has been built in the MALDI-LIT-ESI configuration. The design features two independent ion source/ion optical channels connected to opposite ends of a single mass analyzer. The instrument consists of a commercial MALDI-LIT instrument modified by the addition of a home-built vacuum manifold, ion optical system, control electronics, and programming necessary to couple an atmospheric pressure interface to the commercial instrument. In addition to the added ESI functionality, the capabilities of the system also include simultaneous dual-channel ion introduction and analysis and high-duty cycle electronic switching (<1 s) between ion channels. Analytical and ion chemical applications of the dual-source system are explored. One analytical application is the enhanced protein sequence coverage achieved when using both ESI and MALDI to examine a tryptic digest of a six-protein mixture. The differences in the efficiency with which peptides in a mixture are ionized by the two methods give improved sequence coverage when both are applied. Other analytical applications include the use of the ions from one source as intensity or mass standards for the analyte ions from the other. An ion chemistry application involves the use of energy-resolved tandem mass spectrometry (MS/MS) to seek evidence for the generation of isomeric ions from a particular compound using the two ionization methods. A high level of agreement was achieved between the MS/MS spectra recorded under a variety of conditions after ESI and MALDI ionization; this provides evidence of the reproducibility and internal consistency of data from the dual source instrument. However, each of the peptides examined generated identical populations of structures in the two ionization methods under our conditions which are interpreted as involving slow cooling into the most stable minimum on the potential energy surface.  相似文献   

20.
A highly sensitive, specific, and robust method for the analysis of oxidized metabolites of linoleic acid (LA), arachidonic acid (AA), and docosahexaenoic acid (DHA) was developed using charge-switch derivatization, liquid chromatography–electrospray ionization tandem mass spectrometry (LC–ESI MS/MS) with selected reaction monitoring (SRM) and quantitation by high mass accuracy analysis of product ions, thereby minimizing interferences from contaminating ions. Charge-switch derivatization of LA, AA, and DHA metabolites with N-(4-aminomethylphenyl)-pyridinium resulted in a 10- to 30-fold increase in ionization efficiency. Improved quantitation was accompanied by decreased false positive interferences through accurate mass measurements of diagnostic product ions during SRM transitions by ratiometric comparisons with stable isotope internal standards. The limits of quantitation were between 0.05 and 6.0 pg, with a dynamic range of 3 to 4 orders of magnitude (correlation coefficient r> 0.99). This approach was used to quantitate the levels of representative fatty acid metabolites from wild-type (WT) and iPLA2γ–/– mouse liver identifying the role of iPLA2γ in hepatic lipid second messenger production. Collectively, these results demonstrate the utility of high mass accuracy product ion analysis in conjunction with charge-switch derivatization for the highly specific quantitation of diminutive amounts of LA, AA, and DHA metabolites in biologic systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号