首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

2.
A LC-MS/MS method was validated for the determination of BA011FZ041, a styrylquinoline derivative. After addition of BA011FZ055 as internal standard (IS), the method involved solid phase extraction (SPE), LC separation with an ether-phenyl column and quantification by MS/MS after positive ESI. The calibration curve, ranging from 1 to 500 ng/mL was fitted to a 1/x-weighted quadratic regression model. Lower limit of quantification (LLOQ) was 1 ng/mL using 100 microL of plasma. Intra- and inter-assay precision and accuracy values were within the regulatory limits. The method was successfully applied to the determination of BA011FZ041 in rat plasma and PBMCs after i.v. dosing.  相似文献   

3.
High-performance liquid chromatography with reductive electrochemical detection (HPLC-ECD) method has been used for assaying artemisinins since 1985. Although the methods have been remarkably improved, tandem mass spectrometry (LC-MS/MS) systems with significant advantages have gradually replaced HPLC-ECD to analyze artesunate and dihydroartemisinin in plasma. In the present study, the two methods were evaluated for linearity, quantitation limits, selectivity, precision, and accuracy. The HPLC-ECD performed well in terms of various validation parameters, and showed a good agreement with the LC-MS/MS when calibrated in plasma. However, the major benefit of LC-MS/MS is that it requires only one-tenth the plasma volume needed by HPLC-ECD assay.  相似文献   

4.
Current analytical methods used for screening drugs and their metabolites in biological samples from victims of drug-facilitated sexual assault (DFSA) or other vulnerable groups can lack sufficient sensitivity. The application of liquid chromatography, employing small particle sizes, with tandem mass spectrometry (MS/MS) is likely to offer the sensitivity required for detecting candidate drugs and/or their metabolites in urine, as demonstrated here for ketamine. Ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) was performed following extraction of urine (4 mL) using mixed-mode (cation and C8) solid-phase cartridges. Only 20 microL of the 250 microL extract was injected, leaving sufficient volume for other assays important in DFSA cases. Three ion transitions were chosen for confirmatory purposes. As ketamine and norketamine (including their stable isotopes) are available as reference standards, the assay was additionally validated for quantification purposes to study elimination of the drug and primary metabolite following a small oral dose of ketamine (50 mg) in 6 volunteers. Dehydronorketamine, a secondary metabolite, was also analyzed qualitatively to determine whether monitoring could improve retrospective detection of administration. The detection limit for ketamine and norketamine was 0.03 ng/mL and 0.05 ng/mL, respectively, and these compounds could be confirmed in urine for up to 5 and 6 days, respectively. Dehydronorketamine was confirmed up to 10 days, providing a very broad window of detection.  相似文献   

5.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

6.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

7.
Dihydroartemisinin (DHA) is a sesquiterpene used in the world as an antimalarial. To evaluate the pharmacokinetics of dihydroartemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the quantitation of dihydroartemisinin in rat plasma. For detection, a Sciex API 4000 LC-MS/MS with a TurboIonSpray ionization (ESI) inlet in the positive ion-multiple reaction monitoring (MRM) mode was used. The plasma samples were pre-treated by a simple liquid-liquid extraction with diethyl ether. The statistical evaluation for this method reveals excellent linearity, accuracy and precision for the range of concentrations 0.2-100.0 ng/mL. The method had a lower limit of quantification (LLOQ) of 0.2 ng/mL for beta-dihydroartemisinin in 100 microL of plasma. The method was successfully applied to the characterization of the pharmacokinetic profile of beta-dihydroartemisinin in rats after oral administration.  相似文献   

8.
Rauh M  Gröschl M  Rascher W  Dörr HG 《Steroids》2006,71(6):450-458
Plasma 17 alpha-hydroxyprogesterone (17-OHP), androstenedione and testosterone measurements are important for the diagnosis and monitoring of hyperandrogenic disorders, most importantly for congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency. The reliability of immunoassays has proved questionable especially for newborns and children. In order to reduce the analytical interferences due to cross-reactivity or matrix effects, to improve accuracy and shorten the analysis time, we have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with atmospheric pressure chemical ionization (APCI) for simultaneous measurement. An on-line extraction cartridge with column-switching technique and liquid chromatography over a Chromolith RP 18 e column allow a rapid and easy quantification. The lowest limit of detection was 0.03-0.06 microg/L. Our method has proved linear up to 250 microg/L (r=0.999). Recoveries (S.D.) of 17-OHP, androstenedione and testosterone in plasma were 100% (5), 102% (2) and 92% (4), respectively. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for 17-OHP (excluding neonate samples) was y=1.942 x+0.255 nmol/L (r=0.695; n=97). In comparison to our values, the immunoassay generally overestimates steroid concentration. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for testosterone was y=0.963 x+0.035 nmol/L (r=0.955; n=107). Preliminary reference intervals for children were determined as a function of age and sex. The sensitivity and specificity of the LC-MS/MS method offer advantages over routine immunoassays due to the elimination of interferences especially for newborns, high throughput and short chromatographic run time.  相似文献   

9.
Turbulent flow chromatograph (TFC) is a technique for the direct and efficient analysis of drugs and metabolites in biological matrices. We report here TFC on-line with an HPLC-MS/MS assay for the determination of 5-[2,4-dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)phenyl]methyl]benzamide (I, MK-0767, KRP297, Fig. 1) in plasma. Samples were transferred using an automated system followed by the addition of internal standard (II), prepared in 0.1 M ammonium acetate (pH 4.0). The plasma samples were directly injected onto a C18 turbulent flow column on-line with an HPLC-MS/MS system, and the analytical column used was a ThermoHypersil Keystone C18. Detection was achieved by MS/MS, using positive ionization on a TurboIonSpray probe, operated in multiple reaction monitoring (MRM) mode. The linear range was 4-2000 ng/mL for I when using 50 microL of plasma. The method exhibited good linearity and reproducibility. The method also showed good selectivity and ruggedness when applied to clinical samples, and was successfully cross-validated with a conventional off-line SPE, LC-MS/MS method.  相似文献   

10.
A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases.  相似文献   

11.
A 96-well protein precipitation, liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated for the determination of fudosteine in human plasma. After protein precipitation of the plasma samples (50 microL) by the methanol (150 microL) containing the internal standard (IS), erdosteine, the 96-well plate was vortexed for 5 min and centrifuged for 15 min. The 100 microL supernatant and 100 microL mobile phase were added to another plate and mixed and then the mixture was directly injected into the LC-MS/MS system in the negative ionization mode. The separation was performed on a XB-CN column for 3.0 min per sample using an eluent of methanol-water (60:40, v/v) containing 0.005% formic acid. Multiple reaction monitoring (MRM) using the precursor-product ion transitions m/z 178-->91 and m/z 284-->91 was performed to quantify fudosteine and erdosteine, respectively. The method was sensitive with a lower limit of quantification (LLOQ) of 0.02 microg mL(-1), with good linearity (r>0.999) over the linear range of 0.02-10 microg mL(-1). The within- and between-run precision was less than 5.5% and accuracy ranged from 94.2 to 106.7% for quality control (QC) samples at three concentrations of 0.05, 1 and 8 microg mL(-1). The method was employed in the clinical pharmacokinetic study of fudosteine formulation product after oral administration to healthy volunteers.  相似文献   

12.
The clinical development of a sensitizer for photodynamic therapy (PDT) requires the structural identification of the photoproducts and their quantification in biological fluids and tissues. We describe the LC-MS identification of the most important photoproducts of a cationic phthalocyanine sensitizer (RLP068/Cl) and a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of the main photoproduct (the cationic phthalimide derivative 3-[(1,3-dioxo-2,3-dihydro-1H-isoindol-4-yl)oxy]-N,N,N-trimethylbenzenaminium chloride) in rabbit plasma. The tri-deuterated product was used as co-eluting internal standard. The cationic photoproduct was isolated from plasma samples by protein precipitation with perchloric acid in methanol (7%, v/v). HPLC step was performed on a Phenomenex Synergi Hydro-RP column (20 mm x 2.0 mm, 2 microm particles) with a mobile phase of 0.5% (v/v) aqueous TFA/methanol (85:15, v/v). Flow rate was 0.2 mL/min and 40 microL injection were performed. Run time was 10 min. Detection was achieved by means of a Bruker Esquire 3000+ ion trap mass spectrometer equipped with an ESI source working in positive mode. A multiple reaction monitoring method following the transitions 297.1 --> 282.1 for the analyte and 300.1 --> 282.1+285.1 for the internal standard was used. The analytical method was validated over the concentration range 0.46-91.2 ng/mL and lower limits of detection (LLOD) and quantification (LLOQ) respectively of 0.2 and 0.5 ng/mL were found.  相似文献   

13.
For the first time, a liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the simultaneous determination of ribavirin and rabavirin base was developed and validated over the concentration range of 10-5,000 ng/ml, respectively, using a 0.025 ml monkey plasma sample. Ribavirin, ribavirin base, and the internal standards were extracted from monkey plasma via protein precipitation. After evaporation of the supernatant, the extract was reconstituted with 5% methanol (containing 0.1% formic acid) and injected onto the LC-MS/MS system. Optimum chromatographic separation was achieved on a Waters Atlantis dc18 (150 mm x 2.1mm, 5 microm) column with mobile phase run in gradient with 100% water containing 0.5% formic acid (A) and 90% acetonitrile (containing 0.5% formic acid (B). The flow rate was 0.4-0.6 ml/min with total cycle time of approximately 7.0 min. Post-column addition of acetonitrile (containing 0.1% formic acid) at 0.3 ml/min was used to increase the ionization efficiency in the MS source. The method was validated for sensitivity, linearity, reproducibility, stability and recovery. Lack of adverse matrix effect and carry-over was also demonstrated. The intra-day and inter-day precision and accuracy of the quality control (QC) samples were <9.0% relative standard deviation (R.S.D.) and 10.8% bias for ribavirin, and 10.3% R.S.D. and 11.3% bias for ribavirin base. The current specific, accurate and precise assay is useful in support of the toxicokinetic and pharmacokinetic studies of these compounds.  相似文献   

14.
We describe a sensitive determination of aspirin (ASA) and its three metabolites (salicylic acid [SA], 2,3-dihydroxybenzoic acid [2,3-DHBA], and 2,5-dihydroxybenzoic acid [gentisic acid (GA)]) in rat plasma. Analysis was carried out by on-line solid-phase extraction (SPE) using a methylcellulose-immobilized-strong anion-exchanger (MC-SAX), followed by liquid chromatography (LC) coupled with UV detection. The lower limits of quantitation for ASA and SA were 60 ng/mL in 100 microL of plasma, respectively. This method was validated with respect to intra- and inter-day precision, accuracy, and linearity up to concentrations of 20,000 ng/mL for ASA, SA, 2,3-DHBA and gentisic acid, respectively. The method was successfully applied to an analysis of the pharmacokinetics of ASA and SA in rats.  相似文献   

15.
Clinical proteomics requires the stable and reproducible analysis of a large number of human samples. We report a high-throughput comprehensive protein profiling system comprising a fully automated, on-line, two-dimensional microflow liquid chromatography/tandem mass spectrometry (2-D microLC-MS/MS) system for use in clinical proteomics. A linear ion-trap mass spectrometer (ITMS) also known as a 2-D ITMS instrument, which is characterized by high scan speed, was incorporated into the microLC-MS/MS system in order to obtain highly improved sensitivity and resolution in MS/MS acquisition. This system was used to evaluate bovine serum albumin and human 26S proteasome. Application of these high-throughput microLC conditions and the 2-D ITMS resulted in a 10-fold increase in sensitivity in protein identification. Additionally, peptide fragments from the 26S proteasome were identified three-fold more efficiently than by the conventional 3-D ITMS instrument. In this study, the 2-D microLC-MS/MS system that uses linear 2-D ITMS has been applied for the plasma proteome analysis of a few samples from healthy individuals and lung adenocarcinoma patients. Using the 2-D and 1-D microLC-MS/MS analyses, approximately 250 and 100 different proteins were detected, respectively, in each HSA- and IgG-depleted sample, which corresponds to only 0.4 microL of blood plasma. Automatic operation enabled the completion of a single run of the entire 1-D and 2-D microLC-MS/MS analyses within 11 h. Investigation of the data extracted from the protein identification datasets of both healthy and adenocarcinoma groups revealed that several of the group-specific proteins could be candidate protein disease markers expressed in the human blood plasma. Consequently, it was demonstrated that this high-throughput microLC-MS/MS protein profiling system would be practically applicable to the discovery of protein disease markers, which is the primary objective in clinical plasma proteome projects.  相似文献   

16.
The concentration of polyamines in red blood cells (RBCs) is considered to be an index of cell proliferation. This index has been demonstrated to be of clinical importance for the follow-up and treatment of some cancer patients. The concentration of polyamines in RBCs is usually determined by high-performance liquid chromatography (HPLC) with fluorescence detection. In the current work, we present a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of putrescine, spermidine, and spermine, the three major polyamines in RBCs. The polyamines were dansylated and analyzed by an LC gradient of 20-min duration on a C18 column on-line with a tandem mass spectrometer. An internal standard (1,8-diaminooctane) was used for quantification. This method exhibited excellent linearity for the three polyamines with regression coefficients higher than 0.99. The limits of detection for putrescine, spermidine, and spermine were 0.10, 0.75, and 0.50 pmol/ml, respectively. The intrarun precision values for putrescine, spermidine, and spermine all were better than 10%, and the interrun precision values were 13%, 9%, and 20%, respectively. The LC-MS/MS method is sufficiently simple and reliable enough to replace the currently used HPLC method with fluorescence detection in which putrescine is not always detectable.  相似文献   

17.
Direct plasma injection technology coupled with a LC-MS/MS assay provides fast and straightforward method development and greatly reduces the time for the tedious sample preparation procedures. In this work, a simple and sensitive bioanalytical method based on direct plasma injection using a single column high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) was developed for direct cocktail analysis of double-pooled mouse plasma samples for the quantitative determination of small molecules. The overall goal was to improve the throughput of the rapid pharmacokinetic (PK) screening process for early drug discovery candidates. Each pooled plasma sample was diluted with working solution containing internal standard and then directly injected into a polymer-coated mixed-function column for sample clean-up, enrichment and chromatographic separation. The apparent on-column recovery of six drug candidates in mouse plasma samples was greater than 90%. The single HPLC column was linked to either an atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI) source as a part of MS/MS system. The total run cycle time using single column direct injection methods can be achieved within 4 min per sample. The analytical results obtained by the described direct injection methods were comparable with those obtained by semi-automated protein precipitation methods within +/- 15%. The advantages and challenges of using direct single column LC-MS/MS methods with two ionization sources in combination of sample pooling technique are discussed.  相似文献   

18.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

19.
A simple and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method using an atmospheric pressure chemical ionization source (APCI) for the quantification of fenretinide (4-HPR) in mouse plasma was developed and validated. After a simple protein precipitation of plasma sample by acetonitrile, 4-HPR was analyzed by LC-APCI-MS/MS. High-performance liquid chromatography (HPLC) separation was conducted on a Hypurity C18 column (50mmx2.1mm, 5microm) with a flow rate 0.60mL/min using a gradient mobile phase comprised of 0.05% formic acid in water (A) and methanol (B), and a run time of 4.5min. The elimination of a tedious sample preparation process and a shorter run time substantially reduced total analysis time. The method was linear over the range 0.5-100ng/mL, with r>0.998. The intra- and inter-assay precisions were 1.4-9.2% and 5.1-8.2%, respectively, and the intra- and inter-assay accuracies were 93.9-98.6% and 92.7-95.3%, respectively. The absolute recoveries were 90.3% (1.5ng/mL), 97.0% (7.5ng/mL) and 92.1% (75.0ng/mL) for 4-HPR, and 99.1% for the internal standard (150ng/mL). The analytical method had excellent sensitivity using a small sample volume (30microL) with the lower limit of quantification (LLOQ) 0.5ng/mL. This method is robust and has been successfully employed in a pharmacokinetic study of 4-HPR in a mouse xenograft model of neuroblastoma.  相似文献   

20.
An LC-MS/MS method for determination of the break down product of N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) urea derivative, EDU, has been developed and validated for monitoring the residual coupling reagents. Results indicate that the method exhibits suitable specificity, sensitivity, precision, linearity and accuracy for quantification of residual EDU in the presence of meningococcal polysaccharide-diphtheria toxoid conjugate vaccine and other vaccine matrix compounds. The assay has been validated for a detection range of 10-100 ng/mL and then successfully transferred to quality control (QC) lab. This same method has also been applied to the determination of residual diaminohexane (DAH) in the presence of EDU. LC-MS/MS has proven to be useful as a quick and sensitive approach for simultaneous determination of multiple residual compounds in glycoconjugate vaccine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号