首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An electron-capture gas chromatographic procedure was developed for the analysis of p-trifluoromethylphenol, an O-dealkylated metabolite of fluoxetine, in biological samples. A basic extraction of the biological sample was employed, followed by derivatization with pentafluorobenzenesulfonyl chloride. The internal standard, 2,4-dichlorophenol, was added to all samples used in the procedure to aid in quantitation. The practical limit of detection (signal-to-noise ratio>3) for p-trifluoromethylphenol was <5 ng/ml in human plasma samples, <10 ng/g of rat brain tissue, <25 ng/g of rat liver tissue and <25 ng/ml in human and rat urine samples. In the rat, the levels of free p-trifluoromethylphenol in the liver were 10-fold higher than those in the brain, and a substantial amount was excreted in the urine. Human urine samples contained levels of free p-trifluoromethylphenol approximately 30-fold higher than those found in human plasma samples. The procedure described is useful for the detection and quantitation of free p-trifluoromethylphenol in humans and rats treated with fluoxetine.  相似文献   

2.
The presence of covalently bound pyrroloquinoline quinone (PQQ) in bovine plasma amine oxidase (BPAO) was examined by the use of gas chromatography/mass spectrometry. The enzyme was subjected to proteolysis with proteinase in the presence of [U-13C]PQQ as an internal standard. After isolation and derivatization of PQQ with phenyltrimethylammonium hydroxide, molecular peaks at m/z 448 and 462 were used for detection of PQQ and [U-13C]PQQ, respectively, by selected ion monitoring (SIM). In the SIM profile, although the sample extract obtained from BPAO treated with proteinase clearly showed the peak at m/z 462 for the internal standard, there were no peaks detectable at m/z 448, showing the absence of PQQ in the proteolysis digest of BPAO. Thus, our results do not support the claim that BPAO contains covalently bound PQQ in its structure.  相似文献   

3.
A HPLC method was developed for determination of cimetidine in human plasma and urine. Plasma samples were alkalinized followed by liquid extraction with water-saturated ethyl acetate then evaporated under nitrogen. The extracts were reconstituted in mobile phase and injected onto a C(18) reversed-phase column; UV detection was set at 228 nm. Urine samples were diluted with an internal standard/mobile phase mixture (1:9) prior to injection. The lower limit of quantification in plasma and urine were 100 ng/ml and 10 microg/ml, respectively; intra- and inter-day coefficients of variation were 相似文献   

4.
The best conditions for extractions of free pyrroloquinoline quinone (PQQ) from crude biological samples were investigated with various organic solvents and Sep-Pak C18 cartridges. PQQ was measured with use of its native fluorescence in aqueous solution. PQQ was well extracted into n-butanol under acid conditions, and addition of NaCl did not improve the solvent extraction. PQQ, which had been extracted into n-butanol, could be re-extracted into an aqueous phase by addition of either n-heptane or pyridine, or combination of them. PQQ, which had been adsorbed to Sep-Pak C18 cartridges, could be eluted with a mixture of pyridine and water with very excellent recovery. The recovery of 1 micrograms PQQ, which had been added to 1 g human liver, brain and 1 ml plasma and had undergone the n-butanol and the Sep-Pak extractions, was 50, 75 and 105%, respectively. From the blank fluorescence, endogenous levels of free PQQ in human liver, brain and plasma were found not greater than 0.41, 0.08 and 0.13 micrograms/g or ml, respectively, if present.  相似文献   

5.
A high-performance liquid chromatographic method was developed for the determination of a chemoprotective agent, 2-(allylthio)pyrazine (I), in human plasma and urine, and in rat blood and tissue homogenate using diazepam as an internal standard. The sample preparation was simple; 2.5 volumes of acetonitrile were added to the biological sample to deproteinize it. A 50–100 μl aliquot of the supernatant was injected onto a C18 reversed-phase column. The mobile phase employed was acetonitrile–water (55:45, v/v), and it was run at a flow-rate of 1.5 ml/min. The column effluent was monitored using an ultraviolet detector at 330 nm. The retention times for I and the internal standard were 4.0 and 5.1 min, respectively. The detection limits of I in human plasma and urine, and in rat tissue homogenate (including blood) were 20, 20 and 50 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 6.1%) in a concentration range from 0.02 to 10 μg/ml for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

6.
A high-performance liquid chromatographic method was developed for the determination of a new proton pump inhibitor, YH1885 (I), in human plasma and urine, and rat blood and tissue homogenate using fenticonazole as an internal standard. The sample preparation was simple: a 2.5 volume of acetonitrile was added to the biological sample to deproteinize it. A 50-μl aliquot of the supernatant was injected onto a C8 reversed-phase column. The mobile phase employed was methanol-0.005 M tetrabutylammonium dihydrogenphosphate (77:23, v/v), and it was run at a flow-rate of 1.0 ml/min. The column effluent was monitored using an ultraviolet detector at 270 nm. The retention times for I and the internal standard were 9.0 and 10.3 min, respectively. The detection limits for I in human plasma and urine, and in rat tissue homogenate (including blood) were 50, 100 and 100 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 8.84%) for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

7.
This paper describes a sensitive HPLC-electrochemical detection analytical method for determining the concentration of the intravenous anesthetic, propofol, in human or rat plasma or serum and a variety of rat tissues. Internal standard and drug are extracted from serum or plasma and other tissues with pentane. 2,6-tert.-Butylmethylphenol is used as internal standard. It includes a novel steam distillation procedure for separating the highly lipophilic propofol from skin and fat. The plasma/serum assay has a precision of 1–4% (C.V.) in the range 10 ng/ml to 1 μg/ml and permits the assay of 5 ng/ml from 0.1 ml of plasma/serum. The tissue procedure allows the estimation of 50 ng/g in 0.1 g of tissue for most of the major organs with less than 2% (C.V.) precision. This assay was used to measure propofol concentrations in plasma/serum and tissue samples in support of a project to develop a physiological pharmacokinetic model for propofol in the rat.  相似文献   

8.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

9.
An efficient method for the determination of atenolol in human plasma and urine was developed and validated. α-Hydroxymetoprolol, a compound with a similar polarity to atenolol, was used as the internal standard in the present high-performance liquid chromatographic analysis with fluorescence detection. The assay was validated for the concentration range of 2 to 5000 ng/ml in plasma and 1 to 20 μg.ml in urine. For both plasma and urine, the lower limit of detection was 1 ng/ml. The intra-day and inter-day variabilities for plasma samples at 40 and 900 ng/ml, and urine samples at 9.5 μg/ml were <3% (n=5).  相似文献   

10.
A sensitive and selective high-performance liquid chromatographic (HPLC) method was developed for the determination of pramipexole in human plasma and urine. Plasma/urine is made alkaline before pramipexole and BHT-920 (internal standard) are extracted by ethyl ether and back-extracted with a solution that contains heptanesulfonic acid. Separation is achieved by ion-pair chromatography on a Zorbax Rx C8 column with electrochemical detection at 0.6 V for plasma and ultraviolet detection at 286 nm for urine. The retention times of pramipexole and internal standard are approximately 14.4 and 10.7 min, respectively. The assay is linear in concentration ranges of 50 to 15 000 pg/ml (plasma) and 10 to 10 000 ng/ml (urine). The correlation coefficients are greater than 0.9992 for all curves. For the plasma method, the analysis of pooled quality controls (300, 3000, and 10 000 pg/ml) demonstrates excellent precision with relative standard deviations (R.S.D.) (n=18) of 1.1%, 2.3%, and 6.8%, respectively. For the urine method, quality control pools prepared at 30, 300, and 3000 ng/ml had R.S.D. values (n=18) of 2.9%, 1.7%, and 3.0%, respectively. The plasma and urine controls were stable for more than nine and three months, respectively. The mean recoveries for pramipexole and internal standard from plasma were 97.7% and 98.2%, respectively. The mean recoveries for pramipexole and internal standard from urine were 89.8% and 95.1%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values for the quality control samples being less than 6.4 and 5.8% from theoretical for plasma and urine, respectively.  相似文献   

11.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

12.
An HPLC method was developed for the determination of a new oxazolidinone, DA-7867 (I), in human plasma and urine and in rat tissue homogenates. To 100 microl of biological sample, 300 microl acetonitrile and 50 microl methanol containing 10 microg/ml DA-7858 (the internal standard) were added. After vortex-mixing and centrifugation, the supernatant was evaporated under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of the mobile phase and a 50-microl aliquot was injected directly onto the reversed-phase (C(18)) column. The mobile phase, 20 mM KH2PO4:acetonitrile (75:25, v/v) was run at a flow rate of 1.5 ml/min and the column effluent was monitored by a UV detector set at 300 nm. The retention times of I and DA-7858 were approximately 6.5 and 8.7 min, respectively. The detection limits of I in human plasma and urine and in rat tissue homogenates were 20, 20, and 50 ng/ml, respectively.  相似文献   

13.
A selective and sensitive analytical method for the simultaneous measurement of dolasetron (I) and its major metabolite, MDL 74,156 (II), in human plasma and urine samples has been developed using a structural analogue, MDL 101,858, as internal standard (I.S.). The compounds were extracted from plasma and urine using solvent extraction after the addition of the I.S. Chromatographic separation was carried out on a reversed-phase HPLC column and detection and quantification was by fluorescence with excitation and emission wavelengths of 285 and 345 nm, respectively. Linear responses were obtained over concentration ranges of 5 to 1000 pmol/ml for plasma samples and 20 to 1000 pmol/ml for urine samples with correlation coefficients for the calibration curves exceeding 0.999 in all cases. Intra-day and inter-day reproducibility yielded limits of quantification of 10 pmol/ml for I and 5 pmol/ml for II in plasma and 50 pmol/ml for I and II in urine. The method has been applied to the simultaneous analysis of both compounds in plasma and urine samples coming from clinical pharmacokinetic studies.  相似文献   

14.
A combination of two stereoselective assays was developed using column-switching HPLC with electrochemical detection for the determination of free (unconjugated) silibinin and RP-HPLC with UV detection for the measurement of total (free and conjugated) silibinin in human plasma. After extraction of free silibinin and the internal standard hesperetin with diethyl ether the compounds were pre-separated on a RP-CN column. A cut fraction of eluate containing the analytes was then transferred to the RP-18 main column by means of a switching valve for final separation of the compounds. The limit of quantification with electrochemical detection for free silibinin was 0.25 ng/ml per diastereomer. For the determination of total silibinin diastereomers all conjugates were cleaved enzymatically using β-glucuronidase/arylsulfatase at pH 5.6 followed by extraction with diethyl ether of the pH 8.5 alkalized solution. Separation of the diastereomers and of the internal standard naringenin was achieved on a RP-18 column. The limit of quantification with UV detection at 288 nm for total silibinin was 5 ng/ml per diastereomer. Both assays were successfully applied to the stereospecific analysis of silibinin in plasma samples from a pharmacokinetic study of silymarin in human volunteers.  相似文献   

15.
A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases.  相似文献   

16.
Phenethyl isothiocyanate (PEITC) is a dietary compound present in cruciferous vegetables that has cancer-preventive properties. Our objective was to develop and validate a novel liquid chromatography-tandem mass spectrometry procedure to analyze PEITC concentrations in human plasma and urine. Following hexane extraction, ammonia was added to samples to derivatize PEITC to phenethylthiourea. Chromatographic separation was achieved on a C(18) column with acetonitrile/5 mM formic acid (60:40, v/v) as the mobile phase followed by tandem mass spectrometry detection in multiple reaction monitoring mode. Deuterium-labeled PEITC was used as the internal standard. The detection limit was 2 nM and calibration curves were linear from 7.8 to 2000 nM. The intra- and inter-day coefficients of variation were less than 5 and 10%, respectively. The intra- and inter-day accuracies ranged from 101.0 to 104.2% and from 102.8 to 118.6%, respectively. The recovery from spiked human plasma and urine ranged from 100.3 to 113.5% and from 98.3 to 103.9%, respectively. The assay was used to measure PEITC in plasma and urine samples obtained from subjects after consumption of 100g of watercress. This novel assay represents the first analytical method with the sensitivity and specificity to determine plasma and urine concentrations of PEITC.  相似文献   

17.
Aminoethylcysteine ketimine decarboxylated dimer (AECK-DD; systematic name: 1,2-3,4-5,6-7,8-octahydro-1,8a-diaza-4,6-dithiafluoren-9(8aH)-one) is a previously described metabolite of cysteamine that has been reported to be present in mammalian brain, urine, plasma, and cells in culture and vegetables and to possess potent antioxidative properties. Here, we describe a stable isotope gas chromatography-tandem mass spectrometry (GC-MS/MS) method for specific and sensitive determination of AECK-DD in biological samples. (13)C(2)-labeled AECK-DD was synthesized and used as the internal standard. Derivatization was carried out by N-pentafluorobenzylation with pentafluorobenzyl bromide in acetonitrile. Quantification was performed by selected reaction monitoring of the mass transitions m/z 328 to 268 for AECK-DD and m/z 330 to 270 for [(13)C(2)]AECK-DD in the electron capture negative ion chemical ionization mode. The procedure was systematically validated for human plasma and urine samples. AECK-DD was not detectable in human plasma above approximately 4nM but was present in urine samples of healthy humans at a maximal concentration of 46nM. AECK-DD was detectable in rat brain at very low levels of approximately 8pmol/g wet weight. Higher levels of AECK-DD were detected in mouse brain (~1nmol/g wet weight). Among nine dietary vegetables evaluated, only shallots were found to contain trace amounts of AECK-DD (~6.8pmol/g fresh tissue).  相似文献   

18.
Aplidine (dehydrodidemnin B) is a new marine-derived depsipeptide with a powerful cytotoxic activity, which is under early clinical investigation in Europe and in the US. In order to investigate the pharmacokinetic properties of this novel drug, an HPLC–tandem mass spectrometry method was developed for the determination of aplidine in biological samples. Didemnin B, a hydroxy analogue, was used as internal standard. After protein precipitation with acetonitrile and extraction with chloroform, aplidine was chromatographed with a RP octadecylsilica column using a water–acetonitrile linear gradient in the presence of formic acid at the flow-rate of 500 μl/min. The method was linear over a 5–100 ng/ml range (LOD=0.5 ng/ml) in plasma and over a 1.25–125 ng/ml range (LOD=0.2 ng/ml) in urine with precision and accuracy below 14.0%. The intra- and inter-day precision and accuracy were below 12.5%. The extraction procedure recoveries for aplidine and didemnin B were 69% and 68%, respectively in plasma and 91% and 87%, respectively in urine. Differences in linearity, LOQ, LOD and recoveries between plasma and urine samples seem to be matrix-dependent. The applicability of the method was tested by measuring aplidine in rat plasma and urine after intravenous treatment.  相似文献   

19.
A new method for the detection of free and total malonaldehyde (MDA) in human plasma samples based on the derivatization of MDA with 9-fluorenylmethoxycarbonyl hydrazine (FMOC-hydrazine) in an acidic medium was developed. Derivatization was achieved after 4 h at 50 degrees C. The derivatized samples were analyzed by HPLC using a reversed-phase C18 column with fluorescence detection (Ex=270 nm, Em=310 nm). The benefit of this direct injection of deproteinized plasma is to avoid the use of an internal standard. The detection limit was 0.1 pmol (4.0 nmol/L). The recovery of MDA spiked in different human plasma samples was 95.3% (n=25; R.S.D. 5.1%) for the hydrolysation procedure. The total and free MDA in plasma of 15 healthy male volunteers are 426+/-29.8 nmol/L and 153+/-9.6 nmol/L, respectively.  相似文献   

20.
A simple and rapid (extractionless) high-performance liquid chromatographic method with UV detection, at 330 nm, was developed for the simultaneous determination of piroxicam and its major metabolite, 5′-hydroxypiroxicam, in human plasma and urine. Acidified plasma and alkali-treated urine samples are used and naproxen is added as internal standard. The separation is performed at 40°C on a C18 Spherisorb column with acetonitrile-0.1 M sodium acetate (33:67, v/v, pH 3.3) as mobile phase. The retention time is 2.2 min for 5′-hydroxypiroxicam, 2.6 min for piroxicam and 3.2 min for naproxen. The detection limit is 0.05 μg/ml using a 100-μl loop.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号