首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A polymer-modified sonochemically fabricated glucose oxidase microelectrode array with microelectrode population densities of up to 2.5 x 10(5) microelectrodes per square centimetres is reported. These microelectrode sensors were formed by first depositing an insulating film on commercial screen printed electrodes which was subsequently sonicated to form cavities of regular sizes in the film. Electropolymerisation of aniline at the microelectrode cavities formed polyaniline protrusions containing entrapped glucose oxidase. Chemical deposition of polysiloxane from dichlorodimethysilane was used to deposit a thin protective and diffusion mass transport controlling coating over the electrodes. The physical and electrochemical properties of these films were studied. The performance of the final glucose oxidase based microelectrode sensor array is reported.  相似文献   

2.
We present a novel microfabricated device to simultaneously and actively trap thousands of single mammalian cells in alignment with a planar microelectrode array. Thousands of 3 micromdiameter trapping electrodes were fabricated within the bottom of a parallel-plate flow chamber. Cells were trapped on the electrodes and held against destabilizing fluid flows by dielectrophoretic forces generated in the device. In general, each electrode trapped only one cell. Adhesive regions were patterned onto the surface in alignment with the traps such that cells adhered to the array surface and remained in alignment with the electrodes. By driving the device with different voltages, we showed that trapped cells could be killed by stronger electric fields. However, with weaker fields, cells were not damaged during trapping, as indicated by the similar morphologies and proliferation rates of trapped cells versus controls. As a test of the device, we patterned approximately 20000 cells onto a 1cm(2) grid of rectangular adhesive regions, with two electrodes and thus two cells per rectangle. Our method obtained 70+/-1% fidelity versus 17+/-1% when using an existing cell-registration technique. By allowing the placement of desired numbers of cells at specified locations, this approach addresses many needs to manipulate and register cells to the surfaces of biosensors and other devices with high precision and fidelity.  相似文献   

3.
A sonochemically fabricated alcohol oxidase enzyme micro-electrode array is reported. Sensors of this type were fabricated by first depositing an insulating polydiaminobenzene film on supporting gold electrodes. Sonication and subsequent ablation exposed discrete areas of the underlying conducting electrode, which collectively act as a microelectrode array. Electropolymerisation of aniline has been used to generate in situ polyaniline containing entrapped alcohol oxidase. The physical and electrochemical properties of these films were studied and reported within this paper. The final composites were shown to behave with microelectrode performance characteristics for the detection of aqueous ethanol concentrations.  相似文献   

4.
We present a novel microfabricated device to simultaneously and actively trap thousands of single mammalian cells in alignment with a planar microelectrode array. Thousands of 3 Ipm diameter trapping electrodes were fabricated within the bottom of a parallel-plate flow chamber. Cells were trapped on the electrodes and held against destabilizing fluid flows by dielectrophoretic forces generated in the device.In general, each electrode trapped only one cell. Adhesive regions were patterned onto the surface in alignment with the traps such that cells adhered to the array surface and remained in alignment with the electrodes. By driving the device with different voltages, we showed that trapped cells could be killed by stronger electric fields. However, with weaker fields, cells were not damaged during trapping, as indicated by the similar morphologies and proliferation rates of trapped cells versus controls. As a test of the device, we patterned approximately 20,000 cells onto aI cm2 grid of rectangular adhesive regions, with two electrodes and thus two cells per rectangle. Our method obtained 70 +/- 1% fidelity versus 17 +/- 1% when using an existing cell-registration technique. By allowing the placement of desired numbers of cells at specified locations, this approach addresses many needs to manipulate and register cells to the surfaces of biosensors and other devices with high precision and fidelity.  相似文献   

5.
A novel amperometric biosensor based on polypyrrole (PPy) nanotube array deposited on a Pt plated nano-porous alumina substrate and its performances are described. Glucose oxidase (GOx) enzyme was selected as the model enzyme in this study. Commercially available nano-porous alumina discs were used to fabricate electrodes in order to study the feasibility of enzyme entrapment by physical adsorption. A PPy/PF6- film comprising of nanotube array was synthesized using a solution containing 0.05 M Pyrrole and 0.1 M NaPF6 at a current density of 0.3 mA/cm2 for 90 s. The immobilization was done by physical adsorption of 5 microL of GOx (from a stock solution of 2 mg/mL of 210 U/mg) on each electrode. A sensitivity of 7.4 mA cm(-2) M(-1) was observed with PPy nanotube array where the maximum tube diameter was 100 nm. A linear range of 500 microM-13 mM and a response time of about 3 s were observed with a nanotube array where the maximum tube diameter was 200 nm. The synthesized nanotube arrays were characterized by galvanostatic electrochemical technique. Calculated value of apparent Michaelis-Menten constant (Km) was 7.01 mM. The use of nano-porous template electrodes leads to an efficient enzyme loading and provides an increased surface area for sensing the reaction. These factors contribute to increase the characteristic performances of the novel biosensor.  相似文献   

6.
A two-step method for the directed immobilization of nucleic acids at ultramicroelectrodes with micron-size dimensions is described. The approach is based on the immobilization of streptavidin at the surface of carbon or noble metal electrodes within a novel electro-deposited polymer, formed by electropolymerization of the natural compound scopoletin (7-hydroxy-6-methoxy-coumarin) at potentials between 0.4 and 0.7 V vs. Ag/AgCl. Biotin-tagged nucleic acids or proteins are immobilized on top of the modified electrodes in a second step. The new method has some advantages compared to classical electropolymerization approaches (e.g. polypyrrole, polyphenol), because the growing polymer is highly hydrophilic, resulting in efficient incorporation of streptavidin and a high biotin binding capacity of 6 pmol cm(-2). The polymer film seems to be non-conductive but shows good swelling properties in aqueous solutions. The feasibility of the method for the electro-directed biochemical modification of individual microelectrodes has been demonstrated by sequential immobilization of two different single strand oligonucleotides onto interdigitated ultramicroelectrodes. The resulting miniature DNA probe was used for single base mutation detection with two synthetic targets (fluorescence-labeled 17-mer oligomers) by evaluating the fluorescence patterns after hybridisation with the immobilised DNA probes. The new method is useful for the production of microelectrode based DNA chips and for the electro-directed immobilisation of biomolecules at microelectrode structures with high spatial resolution and yield.  相似文献   

7.
An electrochemical microanalytical system consisting of a microelectrode array, a micromachined flow-through assembly, and a multichannel potentiostat were constructed for highly sensitive biosensing. Thin-film platinum microelectrode arrays consisting of four interdigitated microelectrodes (IDAs), which are spaced in the sub-micrometer range, were fabricated using silicon technology. On top of this chip, a micromachined flow-through cell was mounted. Using a home made miniaturized multipotentiostat, amperometric measurements of the individual electrodes at different and changing potentials, respective to a single reference electrode, were performed simultaneously. The signal generation, signal processing and the analytical system were controlled by a computer (PC type) and special software. An improved sensor sensitivity was achieved by multielectrode detection and averaging of the IDA responses.

By applying both the oxidation and reduction potentials of reversible redox molecules to pairs of the interdigitated electrodes, an increased current generation can be observed. Thus the steady state current of mediators such as benzoquinone can be amplified by a factor of 30 compared with conventional electrodes. This measuring principle was applied to determine of the activity of hydrolases by detecting the enzyme generated p-aminophenol in the nanomolar range. By combining both, the averaging and the recycling procedures, the detection limit of amperometric biosensing devices may be lowered by about one and a half orders of magnitude.  相似文献   


8.
A novel and patented procedure is described for the sonochemical fabrication of a new class of microelectrode array based sensor with electrode element populations of up to 2 x 10(5) cm(-2). For some years it has been accepted that microelectrode arrays offer an attractive route for lowering minimum limits of detection and imparting stir (convectional mass transport) independence to sensor responses; despite this no commercial biosensors, to date, have employed microelectrode arrays, largely due to the cost of conventional fabrication routes that have not proved commercially viable for disposable devices. Biosensors formed by our sonochemical approach offer unrivalled sensitivity and impart stir independence to sensor responses. This format lends itself for mass fabrication due to the simplicity and inexpensiveness of the approach; in the first instance impedimetric and amperometric sensors are reported for glucose as model systems. Sensors already developed for ethanol, oxalate and a number of pesticide determinations will be reported in subsequent publications.  相似文献   

9.
A microelectrode array (MEA) consisting of 34 silicon nitride passivated Pt-tip microelectrodes embedded on a perforated silicon substrate (porosity 35%) has been realized. The electrodes are 47 microns high, of which only the top 15 microns are exposed Pt-tips having a curvature of 0.5 micron. The MEA is intended for extracellular recordings of brain slices in vitro. Here we report the fabrication, characterization and initial electrophysiological evaluation of the first generation of Pt-tip MEAs.  相似文献   

10.
The development of neuron-microelectrode interfaces (neurochips) is highly desirable for the non-invasive recording of the cellular response to neuroactive drugs as well as the electrical stimulation of nervous tissue by implantable electrodes. A prerequisite for neuron-to-electrode signal transmission (NEST) is the formation of synapse-like contacts between the neuronal cell and the conductive surface of a microelectrode array. We attempted synapse formation by neuronal differentiation of rat pheochromocytoma cells (PC12) and blastocyst-derived murine embryonic stem cells (ES-J1) on interdigitated microelectrode arrays that were made of gold (Au), platinum (Pt), or indium tin oxide (ITO). PC12 or ES cells were in vitro differentiated by incubation with nerve growth factor (NGF) and forskolin, or by serum deprivation and treatment with basic fibroblast growth factor (FGF-2), respectively. On top of ITO electrodes, the neuronal cells extended extremely long processes that terminated in pili-like contact structures, which is typical for growth cone formation. ES cells differentiated into neurons as verified by immunofluorescence staining of MAP-2 and developed synapse-like junctions with the ITO electrode surface as indicated by synaptophysin staining. Differentiated PC12 and ES cells showed bona fide morphological characteristics of synaptic growth cones that were unprecedented in tissue culture. Cones formed by PC12 cells could be stimulated with KCI and carbachol as shown by uptake of FM1-43, a fluorescent marker for synaptic vesicle formation. In contrast to Electrical Cell Impedance Spectroscopy (ECIS) recordings, AC impedance spectrometry with differentiated PC12 cells settled on interdigitated microelectrode arrays revealed lower AC impedance than that with undifferentiated cells, indicating that the complex impedance is dependent on ion fluxes at the neuron-to-electrode contact surface.  相似文献   

11.
In this paper, a highly sensitive, reagentless, electrochemical strategy is reported for the detection of a cancer biomarker-Vascular Endothelial Growth Factor (VEGF). Disc shaped carbon fiber microelectrodes were used as the immunosensor platform. Ferrocene monocarboxylic acid labeled anti-VEGF was covalently immobilized on the microelectrode surface using a Jeffamine cross-linker. The formation of immunocomplexes leads to a decrease in the electrochemical signal of ferrocene monocarboxylic acid owing to increased spatial blocking of microelectrode surface. These signal changes enable quantitative detection of VEGF in solution. Voltammetric measurements were conducted to evaluate the interfacial immunoreactions and to quantitatively detect VEGF biomarker. The proposed immunosensing strategy allows a rapid and sensitive means of VEGF analysis with a limit of detection of about 38 pg/mL. This opens up the possibility of employing these electrodes for various single cell analysis and clinical applications. Further, experimental conditions such as concentration of the immobilized antibodies and incubation period were optimized. Following this, the stability and specificity of the immunosensors were also evaluated.  相似文献   

12.
Several non-viral techniques involving the use of liposomes, particle bombardment and electroporation have been used for efficient transfection of plasmids and other molecules into cells. Current approaches target whole or bulk regions of tissue, lacking the desired spatial control over the transfection process. In this study, we present a novel approach using microsystems to achieve spatial and temporal control over the transfection process in adherent cells. A 6x6 MEA (microelectrode array) with 100 microm microelectrode dimension was developed on a silicon substrate using standard microfabrication procedures and passivated with a biocompatible layer. Using finite element models, electric field intensities were simulated and locations of optimal electroporation zones in the cell culture on the microelectrode surface were predicted. The MEA was subsequently tested using 3T3 fibroblasts cultured on the MEA surface for 96 h and stimulation voltages in the range of 2-5 V in the presence of propidium iodide (PI), a cell impermeant dye. Maximum electric field intensities in the z-direction were estimated to be in the range of 320-820 V/cm for applied differential voltages in the range of 2-5 V. Cells directly on the top and on the edges of the stimulating microelectrodes in the MEA were preferentially transfected with PI as predicted by the simulations. The results of these experiments demonstrate that spatial and temporal control of desired regions of transfection in vitro can be achieved using MEAs and electroporation.  相似文献   

13.
The numerous connections between neuronal cell bodies, made by their dendrites and axons, are vital for information processing in the brain. While dendrites and synapses have been extensively studied, axons have remained elusive to a large extent. We present a novel platform to study axonal physiology and information processing based on combining an 11,011-electrode high-density complementary metal-oxide semiconductor microelectrode array with a poly(dimethylsiloxane) channel device, which isolates axons from somas and, importantly, significantly amplifies recorded axonal signals. The combination of the microelectrode array with recording and stimulation capability with the microfluidic isolation channels permitted us to study axonal signal behavior at great detail. The device, featuring two culture chambers with over 30 channels spanning in between, enabled long-term recording of single spikes from isolated axons with signal amplitudes of 100 μV up to 2 mV. Propagating signals along axons could be recorded with 10 to 50 electrodes per channel. We (i) describe the performance and capabilities of our device for axonal electrophysiology, and (ii) present novel data on axonal signals facilitated by the device. Spontaneous action potentials with characteristic shapes propagated from somas along axons between the two compartments, and these unique shapes could be used to identify individual axons within channels that contained many axonal branches. Stimulation through the electrode array facilitated the identification of somas and their respective axons, enabling interfacing with different compartments of a single cell. Complex spike shapes observed in channels were traced back to single cells, and we show that more complicated spike shapes originate from a linear superposition of multiple axonal signals rather than signal distortion by the channels.  相似文献   

14.
A newly developed multisite array microelectrode for in vivo measurements of L-lactate is presented. The resulting microelectrode is composed of three functional layers. First, Nafion is used to repel interfering electroactive anions, such as ascorbate. Second, L-lactate oxidase immobilized onto the recording sites is used to convert L-lactate to hydrogen peroxide. The H2O2 produced is proportional to L-lactate concentrations and is quantified at the platinum recording sites. Third, a layer of polyurethane is coated over the L-lactate oxidase to adjust the linear range of the microelectrode to one that is compatible with in vivo measurements. This layer reduces the amount of L-lactate that diffuses to the enzyme while not significantly limiting oxygen diffusion. The resulting L-lactate microelectrodes were linear to 20 mM (R2 = 0.997 +/- 0.001) and beyond in some cases with detection limits of 0.078 +/- 0.013 mM (n = 12). The selectivity and response time of these electrodes make them suitable for in vivo measurements in brain tissue. Self-referencing recordings may be utilized to further improve the selectivity of the recordings. However this is not necessary for most applications in the brain, because the resting and stimulated levels of dopamine (DA), norepinephrine (NE), and other potentially interfering cations are two to three orders of magnitude lower than that of in vivo L-lactate, which is in the millimolar range. Preliminary in vivo measures of L-lactate in the brain of anesthetized rats support that the microelectrodes are capable of measuring rapid endogenous changes in vivo.  相似文献   

15.
Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.  相似文献   

16.
This paper describes the development of a novel sonochemically fabricated microelectrode based acetylcholinesterase and polyaniline carbon/cobalt phthalocyanine biosensor for the ultra-sensitive determination of pesticides. Arrays of this type are fabricated using microelectrode templates with population densities of 2 x 10(5) cm(-2). The enzymatic response of the sensors is inhibited upon incubation with the pesticide and in this report it is shown that paraoxon may be determined down to concentrations of 1 x 10(-17) M. This sensitivity has thus far not been achieved and mechanisms accounting for the enhancement of the sensitivity reported here are discussed.  相似文献   

17.
Background and PurposeTumor treating fields (TTFields) are a non-invasive, efficacious treatment modality currently approved for supratentorial glioblastomas. Despite their ability to improve overall survival in supratentorial tumors, the current placement of arrays is limited to the supratentorial head, precluding its use in infratentorial tumors. Infratentorial malignancies are in need of new therapy modalities given their poor prognoses in both children and adults. The aim of this research is to determine whether rearrangement of TTFields may allow for management of infratentorial tumors.Materials and methodsDelivery of TTFields using Novocure’s prototype Optune™ device human male head model was simulated based on brain MRIs from patients with brainstem gliomas to develop a novel array layout designed to extend adequate infratentorial coverage.ResultsArray placement on the vertex, bilateral posterolateral occiput, and superior-posterior neck achieved intensities above 1.1 V/cm (average 1.7 V/cm; maximum 2.3 V/cm) in the vertical field direction and above 1 V/cm (average 2 V/cm; maximum 2.8 V/cm) in the horizontal field direction of the infratentorium. The calculated field intensity within the simulated tumors were in the therapeutic range and demonstrated the effective delivery of TTFields to the infratentorial brain.ConclusionsOur findings suggest that rearrangement of the TTFields standard array with placement of electrodes on the vertex, bilateral posterolateral occiput, and superior-posterior neck allows for adequate electric field distribution in the infratentorium that is within the therapeutic range.  相似文献   

18.
Electronic detection of the binding event between biotinylated bovine serum albumen (BSA) and streptavidin is demonstrated with the chemoreceptive neuron MOS (CnuMOS) device. Differing from the ion-sensitive field-effect transistors (ISFET), CnuMOS, with the potential of the extended floating gate determined by both the sensing and control gates in a neuromorphic style, can provide protein detection without requiring analyte reference electrodes. In comparison with the microelectrode arrays, measurements are gathered through purely capacitive, non-Faradaic interactions across insulating interfaces. By using a (3-glycidoxypropyl)trimethoxysilane (3-GPS) self-assembled monolayer (SAM) as a simple covalent link for attaching proteins to a silicon dioxide sensing surface, a fully integrated, electrochemical detection platform is realized for protein interactions through monotone large-signal measurements or small-signal impedance spectroscopy. Calibration curves were created to coordinate the sensor response with ellipsometric measurements taken on witness samples. By monitoring the film thickness of streptavidin capture, a sensitivity of 25ng/cm2 or 2A of film thickness was demonstrated. With an improved noise floor the sensor can detect down to 2ng/(cm2mV) based on the calibration curve. AC measurements are shown to significantly reduce long-term sensor drift. Finally, a noise analysis of electrochemical data indicates 1/f(alpha) behavior with a noise floor beginning at approximately 1Hz.  相似文献   

19.
A disposable electrochemiluminescent (ECL) immunosensor array was fabricated on a screen-printed carbon electrode (SPCE) substrate to perform multiplexed immunoassay (MIA) for the first time. The SPCE substrate was composed of an array of four carbon working electrodes, one common Ag/AgCl reference electrode, and one common carbon counter electrode. The immunosensor array was constructed by site-selectively immobilizing multiple antigens on different working electrodes of the SPCE substrate. With a competitive immunoassay format, the immobilized antigens competed with antigens in the sample to capture their corresponding tri(2,2'-bipyridyl)ruthenium(II)-labeled antibodies. The ECL signals from the immunosensors in this array were sequentially detected by a photomultiplier with the aid of a homemade single-pore-four-throw switch. Due to the ECL readout mechanism and the sequential detection mode, it could avoid the cross-talk between the adjacent immunosensors, which was common in other reported immunosensor array. Human, rabbit and mouse immunoglobulin Gs were near-simultaneously assayed as the model analytes. The linear ranges for them were 10-400, 20-400, and 20-400 ng/mL, with detection limits of 2.9, 6.1 and 6.5 ng/mL (S/N=3), respectively. This novel ECL strategy based on immunosensor array coupled with non-array detector provided a simple, sensitive, low-cost and time-saving approach for MIA. It showed great application potential in point-of-care test and field analysis of bio-agents, with mass production potential and high throughput.  相似文献   

20.
Machine-pulled high-impedance glass capillary microelectrode is standard for transmembrane potential (TMP) recordings. However, it is fragile and difficult to impale, especially in beating myocardial tissues. We hypothesize that a high-impedance pure iridium metal electrode can be used as an alternative to the glass microelectrode for TMP recording. The TMPs were simultaneously recorded from isolated perfused swine right ventricles with a metal microelectrode and a standard glass microelectrode during pacing and during ventricular fibrillation. The basic morphology of TMP recorded with these electrodes was comparable. The action potential duration (APD) at 90% repolarization was 241 +/- 29 ms for the metal microelectrode and 236 +/- 31 ms for the glass microelectrode with a good correlation (r = 0.99, P < 0.0001). The maximum slope value of the APD restitution curves during pacing was also significantly correlated. One metal microelectrode and >20 glass microelectrodes were needed per study. We conclude that, in isolated perfused swine right ventricles, the TMP recorded by the metal microelectrode is comparable with that recorded by the glass microelectrode. Because the metal microelectrode is more durable than the glass microelectrode, it can serve as an alternative for APD recording and for restitution analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号