首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Illumination of cellular changes caused by mechanical forces present within the laryngeal microenvironment may well guide strategies for tissue engineering the vocal fold lamina propria. The purpose of this study was to compare the response of human vocal fold fibroblasts (hVFF) and bone marrow mesenchymal stem cells (BM-MSC) to vibratory stimulus. In order to study these effects, a bioreactor capable of vibrating two cell seeded substrates was developed. The cell seeded substrates contact each other as a result of the sinusoidal frequency, producing a motion similar to the movement of true vocal folds. Utilizing this bioreactor, hVFF and BM-MSC were subjected to 200 Hz vibration and 20% strain for 8 hours. Immunohistochemistry (Ki-67 and TUNEL) was performed to examine cell proliferation and apoptosis respectively, while semi-quantitative RT-PCR was used to assess extracellular matrix related gene expression. HVFF significantly proliferated (p = 0.011) when subjected to 200 Hz vibration and 20% strain, while BM-MSC did not (p = 1.0). A statistically significant increase in apoptosis of BM-MSC (p = 0.0402) was observed under the experimental conditions; however high cell viability (96%) was maintained. HVFF did not have significantly altered apoptosis (p = 0.7849) when subjected to vibration and strain. Semi-quantitative RT-PCR results show no significant differences in expression levels of collagen I (BM-MSC p = 0.1951, hVFF p = v0.3629), fibronectin (BM-MSC p = 0.1951, hVFF p = 0.2513), and TGF-β1 (BM-MSC p = 0.2534, hVFF p = 0.6029) between vibratory and static conditions in either cell type. Finally, smooth muscle actin mRNA was not present in either vibrated or static samples, indicating that no myofibroblast differentiation occurred for either cell type. Together, these results demonstrate that BM-MSC may be a suitable alternative to hVFF for vocal fold tissue engineering. Further investigation into a larger number of gene markers, protein levels, increased number of donors and vibratory conditions are warranted.  相似文献   

2.
Mechanical and computational models consisting of flow channels with convergent and oscillating constrictions have been applied to study the dynamics of human vocal fold vibration. To the best of our knowledge, no mechanical model has been studied using a material substitute with similar physical properties to the human vocal fold for surgical experimentation. In this study, we design and develop a mechanical larynx with agarose as a vocal fold substitute, and assess its suitability for surgical experimentation. Agarose is selected as a substitute for the vocal fold as it exhibits similar nonlinear hyperelastic characteristics to biological soft tissue. Through uniaxial compression and extension tests, we determined that agarose of 0.375% concentration most closely resembles the vocal fold mucosa and ligament of a 20-year old male for small tensile strain with an R(2) value of 0.9634 and root mean square error of 344.05±39.84?Pa. Incisions of 10 mm lengthwise and 3 mm in depth were created parallel to the medial edge on the superior surface of agar phantom. These were subjected to vibrations of 80, 130, and 180 Hz, at constant amplitude of 0.9 mm over a period of 10 min each in the mechanical larynx model. Lateral expansion of the incision was observed to be most significant for the lower frequency of 80 Hz. This model serves as a basis for future assessments of wound closure techniques during microsurgery to the vocal fold.  相似文献   

3.
Summary The vibrational sensitivity of awake pigeons was tested with the heart rate conditioning method. This method proved to be a very sensitive instrument for the behavioural measurement of the pigeon's sensitivity to mechanical stimuli.Sine wave vibrational stimuli between 50 and 2000 Hz were applied to the 1st, 7th and 16th primary feathers of the wing. The resulting threshold curves were U- or V-shaped with 3 characteristics: (i) The frequency of best response was either 800 or 900 Hz. (ii) Within the broad frequency range of vibrational sensitivity (50 to 2000 Hz) the sensitivity was extremely high at the best frequency: threshold amplitudes lay between 0.5 and 0.09 m. (iii) The threshold curves showed very sharp tuning at best frequency with bandwidths between 0.3 and 0.7 octaves (measured at best frequency 10fold above threshold). The functional meaning of the characteristic vibrational sensitivity of the wing for flight control is discussed; it is interpreted as an adaptation to special situations occurring during flight.Abbreviations CR conditioned response - CS conditioned stimulus - ECG electrocardiogram - HC(s) Herbst corpuscle(s) - UCS unconditioned stimulus All experiments were carried out at the Ruhr-Universität Bochum, Lehrstuhl für Allgemeine Zoologie  相似文献   

4.
In vitro engineering of mechanically active tissues requires the presentation of physiologically relevant mechanical conditions to cultured cells. To emulate the dynamic environment of vocal folds, a novel vocal fold bioreactor capable of producing vibratory stimulations at fundamental phonation frequencies is constructed and characterized. The device is composed of a function generator, a power amplifier, a speaker selector and parallel vibration chambers. Individual vibration chambers are created by sandwiching a custom-made silicone membrane between a pair of acrylic blocks. The silicone membrane not only serves as the bottom of the chamber but also provides a mechanism for securing the cell-laden scaffold. Vibration signals, generated by a speaker mounted underneath the bottom acrylic block, are transmitted to the membrane aerodynamically by the oscillating air. Eight identical vibration modules, fixed on two stationary metal bars, are housed in an anti-humidity chamber for long-term operation in a cell culture incubator. The vibration characteristics of the vocal fold bioreactor are analyzed non-destructively using a Laser Doppler Vibrometer (LDV). The utility of the dynamic culture device is demonstrated by culturing cellular constructs in the presence of 200-Hz sinusoidal vibrations with a mid-membrane displacement of 40 µm. Mesenchymal stem cells cultured in the bioreactor respond to the vibratory signals by altering the synthesis and degradation of vocal fold-relevant, extracellular matrix components. The novel bioreactor system presented herein offers an excellent in vitro platform for studying vibration-induced mechanotransduction and for the engineering of functional vocal fold tissues.  相似文献   

5.
Klemuk SA  Riede T  Walsh EJ  Titze IR 《PloS one》2011,6(11):e27029
Vocal production requires active control of the respiratory system, larynx and vocal tract. Vocal sounds in mammals are produced by flow-induced vocal fold oscillation, which requires vocal fold tissue that can sustain the mechanical stress during phonation. Our understanding of the relationship between morphology and vocal function of vocal folds is very limited. Here we tested the hypothesis that vocal fold morphology and viscoelastic properties allow a prediction of fundamental frequency range of sounds that can be produced, and minimal lung pressure necessary to initiate phonation. We tested the hypothesis in lions and tigers who are well-known for producing low frequency and very loud roaring sounds that expose vocal folds to large stresses. In histological sections, we found that the Panthera vocal fold lamina propria consists of a lateral region with adipocytes embedded in a network of collagen and elastin fibers and hyaluronan. There is also a medial region that contains only fibrous proteins and hyaluronan but no fat cells. Young's moduli range between 10 and 2000 kPa for strains up to 60%. Shear moduli ranged between 0.1 and 2 kPa and differed between layers. Biomechanical and morphological data were used to make predictions of fundamental frequency and subglottal pressure ranges. Such predictions agreed well with measurements from natural phonation and phonation of excised larynges, respectively. We assume that fat shapes Panthera vocal folds into an advantageous geometry for phonation and it protects vocal folds. Its primary function is probably not to increase vocal fold mass as suggested previously. The large square-shaped Panthera vocal fold eases phonation onset and thereby extends the dynamic range of the voice.  相似文献   

6.
Local vibrations--mechanical impedance of the human hand's glabrous skin   总被引:1,自引:0,他引:1  
The mechanical point impedance has been studied in ten different areas of the glabrous skin of the human hand on three male and three female subjects within the frequency range of 20-10 000 Hz. For all tested areas the impedance decreased with increasing frequency down to a minimum value, corresponding to the natural frequency of the skin. After that, the mechanical impedance was directly proportional to the frequency. The highest natural frequency, about 200 Hz, was measured in the distal areas of the finger and the lowest, about 80 Hz, in the proximal areas of the palm (thenar). Small differences in internal damping were also showed to exist. A great amount of handheld tools used in industry have their maximum vibrational levels within the natural frequency range of the skin. In order to avoid adverse effects the skin's mechanical properties should therefore carefully be taken into consideration at designing vibrating tools.  相似文献   

7.
We have measured the vibrational modes of the sound producing membrane in the syrinx of zebra finches and canaries. Excised syringes were driven with a frequency-swept acoustic pressure wave through the trachea, and the resulting vibrations measured using a laser interferometer. The frequency-dependent membrane compliance was measured at 10-20 different positions, giving a detailed picture of the linear vibrational modes of the two membrane components, the medial labium and the medial tympaniform membrane. Nonlinear properties of the membrane were determined by measuring the linear response at several superimposed static pressures. The membrane compliance is dominated by the lowest vibrational mode, a narrow mechanical resonance, at roughly 700 Hz in the zebra finch, that extends over the entire membrane. Several higher-frequency modes were also observed. The frequency of the lowest vibrational mode is determined largely by the mass of the heavier medial labium, rather than the thinner medial tympaniform membrane, suggesting that the medial labium is critical in determining the oscillatory frequency of the syrinx. The difference in mass of the medial labium and medial tympaniform membrane may serve to produce a wave-like motion of the membranes during flow-driven oscillations, thus increasing the efficiency of sound production. Implications for mechanisms of frequency tuning are discussed.  相似文献   

8.
Across mammals many vocal sounds are produced by airflow induced vocal fold oscillation. We tested the hypothesis that stress-strain and stress-relaxation behavior of rat vocal folds can be used to predict the fundamental frequency range of the species' vocal repertoire. In a first approximation vocal fold oscillation has been modeled by the string model but it is not known whether this concept equally applies to large and small species. The shorter the vocal fold, the more the ideal string law may underestimate normal mode frequencies. To accommodate the very small size of the tissue specimen, a custom-built miniaturized tensile test apparatus was developed. Tissue properties of 6 male rat vocal folds were measured. Rat vocal folds demonstrated the typical linear stress-strain behavior in the low strain region and an exponential stress response at strains larger than about 40%. Approximating the rat's vocal fold oscillation with the string model suggests that fundamental frequencies up to about 6 kHz can be produced, which agrees with frequencies reported for audible rat vocalization. Individual differences and time-dependent changes in the tissue properties parallel findings in other species, and are interpreted as universal features of the laryngeal sound source.  相似文献   

9.
Impedance profiles of peripheral and central neurons   总被引:1,自引:0,他引:1  
The electrical impedance of trigeminal ganglion cells (in vivo) and hippocampal CA1 neurons (in vitro) of guinea pigs was measured in the frequency range of 5-1250 Hz using intracellular recording techniques with single microelectrodes and computerized methodology. The transfer functions of the electrode and the electrode-neuron system were computed from the ratio of fast Fourier transforms of the output voltage response from the neuron and input current composed of sine waves with rapidly increasing frequency which displaced membrane potential by 2-5 mV. We believe these to be the first measurements of complex impedance and transfer functions in peripheral and central neurons of vertebrates and the first use of such input current functions. The majority of trigeminal ganglion cells did not exhibit electrical behaviour ascribable to a simple resistance-capacitance (RC) circuit but showed a hump at low frequencies (5-250 Hz) in the computed transfer function, probably attributable to resonance. The transfer function in less than 20% of the trigeminal neurons could be fitted approximately to a theoretical transfer function (resistance in series with a parallel RC circuit model) providing values for electrode resistance, effective input resistance, and effective input capacitance. The transfer functions measured in hippocampal CA1 neurons were characterized by a rapid fall-off in the low frequency range (less than 200 Hz). Impedance locus plots approximate the locus corresponding to a series RC circuit in parallel with a parallel RC circuit.  相似文献   

10.
Vibrational loading can stimulate the formation of new trabecular bone or maintain bone mass. Studies investigating vibrational loading have often used whole-body vibration (WBV) as their loading method. However, WBV has limitations in small animal studies because transmissibility of vibration is dependent on posture. In this study, we propose constrained tibial vibration (CTV) as an experimental method for vibrational loading of mice under controlled conditions. In CTV, the lower leg of an anesthetized mouse is subjected to vertical vibrational loading while supporting a mass. The setup approximates a one degree-of-freedom vibrational system. Accelerometers were used to measure transmissibility of vibration through the lower leg in CTV at frequencies from 20 Hz to 150 Hz. First, the frequency response of transmissibility was quantified in vivo, and dissections were performed to remove one component of the mouse leg (the knee joint, foot, or soft tissue) to investigate the contribution of each component to the frequency response of the intact leg. Next, a finite element (FE) model of a mouse tibia-fibula was used to estimate the deformation of the bone during CTV. Finally, strain gages were used to determine the dependence of bone strain on loading frequency. The in vivo mouse leg in the CTV system had a resonant frequency of 60 Hz for +/-0.5 G vibration (1.0 G peak to peak). Removing the foot caused the natural frequency of the system to shift from 60 Hz to 70 Hz, removing the soft tissue caused no change in natural frequency, and removing the knee changed the natural frequency from 60 Hz to 90 Hz. By using the FE model, maximum tensile and compressive strains during CTV were estimated to be on the cranial-medial and caudolateral surfaces of the tibia, respectively, and the peak transmissibility and peak cortical strain occurred at the same frequency. Strain gage data confirmed the relationship between peak transmissibility and peak bone strain indicated by the FE model, and showed that the maximum cyclic tibial strain during CTV of the intact leg was 330+/-82microepsilon and occurred at 60-70 Hz. This study presents a comprehensive mechanical analysis of CTV, a loading method for studying vibrational loading under controlled conditions. This model will be used in future in vivo studies and will potentially become an important tool for understanding the response of bone to vibrational loading.  相似文献   

11.
Recent epidemiological studies suggest a link between transport magnetic fields (MF) and certain adverse health effects. We performed measurements in workplaces of engineers on Russian DC and Swiss AC powered (16.67 Hz) electric trains using a computer based waveform capture system with a 200 Hz sampling rate. MF in DC and AC trains show complex combinations of static and varying components. The most probable levels of quasistatic MF (0.001-0.03 Hz) were in the range 40 microT. Maximum levels of 120 microT were found in DC powered locomotives. These levels are much higher than the geomagnetic field at the site of measurements. MF encountered both in DC and AC powered rail systems showed irregular temporal variability in frequency composition and amplitude characteristics across the whole frequency range studied (0-50 Hz); however, more than 90% of the magnetic field power was concentrated in frequencies 相似文献   

12.
Vibrational optical coherence elastography (OCE) is a promising tool for extracting the mechanical property of soft tissue. Purpose of this study is focusing on settling the optimal frequency range for vibrational OCE with evenly distributed stress filed. A finite element model of 2% agar phantom was built by ANSYS with a vibration stimulation frequency range from 200 to 3000 Hz. Practical experiments were carried out for cross‐validation with the same frequencies and sample. Lateral and horizontal stress filed distributions under different frequencies were mathematically evaluated by coefficient of variance and degree of linearity. Results from simulation and practical experiment cross‐validated each other and 1000 Hz was set as the maximum ideal frequency for vibrational OCE, while the minimum frequency is set by theoretical calculation with a result of 250 Hz. An ex vivo biological sample was utilised to testify performance of vibrational OCE with excitation frequencies in and out of concluded optimal range, which showed that stiffness was better mapped out in optimal frequency range.  相似文献   

13.
A bioreactor previously described was used to quantify the shear strain along a bioengineered tissue scaffold driven at low audio frequencies (20–200 Hz). Standing wave patterns were calculated analytically by solving a classical boundary value problem for a vibrating string under tension and bending stiffness. Boundary conditions were non-traditional in that small pivot arms at the endpoints allowed neither the displacement nor the velocity to go to zero. The calculations were corroborated with stroboscopic measurement of the motion of the material in the bioreactor. Results indicate that shear strains up to 0.2 can be obtained at low frequencies (20 Hz), with a gradual decrease at higher frequencies due to the decaying amplitude response of the mechanical driver. The bioreactor may be useful for approximating the Young's modulus of the material in situ by probing for resonance frequencies in the standing wave pattern. A yet unsolved problem is a variable drag coefficient along the length of the material due to fluid turbulence in the culture medium.  相似文献   

14.
Vocal folds are used as sound sources in various species, but it is unknown how vocal fold morphologies are optimized for different acoustic objectives. Here we identify two main variables affecting range of vocal fold vibration frequency, namely vocal fold elongation and tissue fiber stress. A simple vibrating string model is used to predict fundamental frequency ranges across species of different vocal fold sizes. While average fundamental frequency is predominantly determined by vocal fold length (larynx size), range of fundamental frequency is facilitated by (1) laryngeal muscles that control elongation and by (2) nonlinearity in tissue fiber tension. One adaptation that would increase fundamental frequency range is greater freedom in joint rotation or gliding of two cartilages (thyroid and cricoid), so that vocal fold length change is maximized. Alternatively, tissue layers can develop to bear a disproportionate fiber tension (i.e., a ligament with high density collagen fibers), increasing the fundamental frequency range and thereby vocal versatility. The range of fundamental frequency across species is thus not simply one-dimensional, but can be conceptualized as the dependent variable in a multi-dimensional morphospace. In humans, this could allow for variations that could be clinically important for voice therapy and vocal fold repair. Alternative solutions could also have importance in vocal training for singing and other highly-skilled vocalizations.  相似文献   

15.
Research on long-distance vocal communication in mammals has tended to focus on the maximum distances over which a vocal signal might be physically detectable. For example, because elephants and some whales communicate using infrasonic calls, and low frequencies are particularly resilient to attenuation, it has often been assumed that these species can communicate over very long distances. However, a wide range of acoustic characteristics typically carry information on individual identity in mammalian calls, and frequency components crucial for social recognition could be distorted or lost as distance from the source increases. We used long-distance playback experiments to show that female African elephants, Loxodonta africana, can recognize a contact call as belonging to a family or bond group member over distances of 2.5 km, but that recognition is more usually achieved over distances of 1-1.5 km. We analysed female contact calls to distinguish source- and filter-related vocal characteristics that have the potential to code individual identity, and rerecorded contact calls 0.5-3.0 km from the loudspeaker to determine how different frequencies persist with distance. Our analyses suggest that the most important frequency components for long-distance communication of social identity may be well above the infrasonic range. When frequency components around 115 Hz become immersed in background noise, once propagation distances exceed 1 km, abilities for long-distance social recognition become limited. Our results indicate that the possession of an unusually long vocal filter, which appears to incorporate the trunk, may be a more important attribute for long-distance signalling in female African elephants than the ability to produce infrasound. Copyright 2003 The Association for the Study of Animal Behaviour. Published by Elsevier Science Ltd. All rights reserved.   相似文献   

16.
A measurement setup combined with a Finite Element (FE) simulation is presented to determine the elasticity modulus of soft materials as a function of frequency. The longterm goal of this work is to measure in vitro the elasticity modulus of human vocal folds over a frequency range that coincides with the range of human phonation. The results will assist numerical simulations modeling the phonation process by providing correct material parameters. Furthermore, the measurements are locally applied, enabling to determine spatial differences along the surface of the material. In this work the method will be presented and validated by applying it to silicones with similar characteristics as human vocal folds.Three silicone samples with different consistency were tested over a frequency range of 20–250 Hz. The results of the pipette aspiration method revealed a strong frequency dependency of the elasticity modulus, especially below 100 Hz. In this frequency range the elasticity moduli of the samples varied between 5 and 27 kPa.  相似文献   

17.
A transfer function from baroreceptor pressure input to sympathetic nerve activity (SNA) shows derivative characteristics in the frequency range below 0.8 Hz in rabbits. These derivative characteristics contribute to a quick and stable arterial pressure (AP) regulation. However, if the derivative characteristics hold up to heart rate frequency, the pulsatile pressure input will yield a markedly augmented SNA signal. Such a signal would saturate the baroreflex signal transduction, thereby disabling the baroreflex regulation of AP. We hypothesized that the transfer gain at heart rate frequency would be much smaller than that predicted from extrapolating the derivative characteristics. In anesthetized rabbits (n = 6), we estimated the neural arc transfer function in the frequency range up to 10 Hz. The transfer gain was lost at a rate of -20 dB/decade when the input frequency exceeded 0.8 Hz. A numerical simulation indicated that the high-cut characteristics above 0.8 Hz were effective to attenuate the pulsatile signal and preserve the open-loop gain when the baroreflex dynamic range was finite.  相似文献   

18.
A common rule for mammals vocalizing in the human audible frequency range (20 Hz–20 kHz) suggests that calls are higher in fundamental frequency (f0) in the young than in adults, because of the smaller sound‐producing structures of the young. Exclusions are rare, for example the pups of Asian house shrews (Suncus murinus) make some call types of the same or higher pitch than adults. In this study, calls from 62 piebald shrews (Diplomesodon pulchellum), 37 1 to 10‐d‐old pups from 10 litters and 25 adults were acoustically investigated in captivity. We found eight call types, all within the human audible frequency range: short and long low‐frequency squeaks with nearly flat contour, high‐frequency squeaks with modulated contour, high‐frequency squeaks with fractured contour, short and long screeches, clicks and whimpers. Seven call types were shared by pups and adults, suggesting that this vocal repertoire commences at birth. Against the common rule, the f0 of squeaks was the same in pups and adults, and the f0 of clicks and screeches was even higher in adults than in pups. These results suggest a non‐descending ontogenetic pathway that not follows the common physical relationship, of the lower f0 for the larger vocal folds.  相似文献   

19.
In transversely sectioned rat hippocampal slices, population spikes and population "EPSPs" were recorded from CA1 neurones in response to the stimulation of Schaffer collateral and commissural inputs. High frequency tetanic stimulation (400 Hz, 200 pulses) of an input induced LLP of the homosynaptic response without significantly changing the heterosynaptic response. This LLP was not interrupted by either a 400 Hz tetanus given to the heterosynaptic input or by verapamil (0.33 microM) which blocks Ca++ channels, but not transmitter release. A low frequency tetanus (20 Hz, 200 pulses) given to an input induces co-occurring homosynaptic and heterosynaptic depressions of about 20 min duration. This tetanus could also mask an established LLP in homosynaptic or heterosynaptic pathway. Verapamil counteracts homo- and heterosynaptic depressions. The population spike as well as the population "EPSP" were depressed following iontophoretic application of Ca++ (2-100 nA) at the CA1 cell body area. These results indicate that homosynaptic and heterosynaptic depressions are at least partly due to an accumulation of Ca++ into CA1 neurones. An established LLP is not interrupted by LLP of another input. Homo- and heterosynaptic depressions mask, but not reverse, LLP.  相似文献   

20.
Most vertebrate muscles are composed of a mixture of fiber types. However, studies of muscle mechanics have concentrated on homogeneous bundles of fibers. Hindlimb muscles of the tiger salamander, Ambystoma tigrinum, present an excellent system to explore the consequences of fiber heterogeneity. Isometric twitches and work loops were obtained in vitro from two muscles, the m. iliotibialis pars posterior (heterogeneous, containing types I, IIa and IIb fibers) and the m. iliofibularis (nearly homogeneous for type IIa fibers). Maximal isometric twitch and tetanic stresses in m. iliotibialis posterior were significantly greater than in iliofibularis. Work loops were obtained over a range of frequencies (0.5-3.0 Hz) and strains (2-6% muscle length) that encompassed the observed ranges in vivo. Work per cycle from the homogeneous iliofibularis declined from 1.5-3.0 Hz, while that from the heterogeneous m. iliotibialis posterior increased from 0.5 Hz to 2.5 Hz and declined at 3.0 Hz. Power output from the iliofibularis rose with frequency to at least 3 Hz; power from the iliotibialis posterior rose with frequency to 2.5 Hz and declined thereafter. Mass-specific work per cycle and power output were higher in iliofibularis than iliotibialis posterior over most frequencies and strains tested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号