共查询到20条相似文献,搜索用时 15 毫秒
1.
Humphries D Ruterbories K Chan C Narayanan R 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,810(2):229-234
A sensitive and selective LC-MS-MS method for the isolation and quantification of alpha-methyltyrosine (AMT) from human plasma is described. The method employs a simple protein precipitation using zinc sulfate and sodium hydroxide. This precipitation procedure produced samples with high aqueous content that could be directly injected into a LC-MS-MS system without compromising reverse-phase chromatographic performance. Chromatographic separation was performed on a MetaChem MonoChrom C(18) column (2.0 mm x 50 mm; 5 microm) at a flow rate of 1 mL/min. Compounds were eluted using a gradient mixture of water-acetic acid (100:0.1, v/v) and acetonitrile-acetic acid (100:0.1, v/v). The structural analog alpha-hydroxymethyltyrosine was used as the internal standard. Mass spectrometric detection was carried out with a triple quadrupole mass spectrometer. The method was validated and used to determine human plasma AMT concentrations, and has been implemented to derive pharmacokinetic parameters. 相似文献
2.
Li L Pabbisetty D Carvalho P Avery MA Williamson JS Avery BA 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,867(1):131-137
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify artemisinin in rat serum. The lower limit of quantification (LLOQ) was 4 ng/mL. The calibration curve was linear from 4 ng/mL to 10,000 ng/mL (R=0.998). The assay was based on the selected reaction monitoring (SRM) transitions at m/z 305.4-151.10 for artemisinin and m/z 335.2-163.10 for arteether (internal standard). The artemisinin and internal standard can be separated from endogenous interferences in rat serum. Inter- and intra-day assay variation was less than 15%. The extraction recoveries ranged from 80.0 to 107.3% at the three concentrations (5000, 2000, and 200 ng/mL). This method was successfully applied to pharmacokinetic studies of artemisinin after intravenous and oral administration to rats. 相似文献
3.
Cui S Feng F Ma M Liu H Chen Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,854(1-2):143-151
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration. 相似文献
4.
Satonin DK McCulloch JD Kuo F Knadler MP 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):582-589
A sensitive bioanalytical method for the measurement of two major circulating metabolites of duloxetine [4-hydroxy duloxetine glucuronide (LY550408) and 5-hydroxy-6-methoxy duloxetine sulfate (LY581920)] in plasma is reported. This method produced acceptable precision and accuracy over the validation range of 1-1000 ng/mL. Several issues had to be addressed in order to develop an LC/MS/MS assay for these metabolites. First, 4-hydroxy duloxetine glucuronide required chromatographic resolution from the 5-, and 6-hydroxy duloxetine glucuronide isomers. Second, the glucuronide conjugate is readily ionized under positive ESI conditions, while the sulfate conjugate required negative ESI conditions to obtain adequate sensitivity. Finally, the chromatographic conditions needed to separate the glucuronide isomers were not suitable for the analysis of the sulfate conjugate. The present method addressed these challenges, and was successfully applied to multiple human pharmacokinetic studies in which subjects received oral doses of duloxetine hydrochloride. 相似文献
5.
Xia SM Shen R Sun XY Shen LL Yang YM Ke Y Wang Y Chen DY Han XM 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,857(1):32-39
A sensitive and specific method was developed and validated for the determination of paeoniflorin in rat brain with liquid chromatography-tandem mass spectrometry. Sample pretreatment involved protein precipitation following solid-phase extraction. Paeoniflorin and geniposide (internal standard) were separated isocratically on a Waters Symmetry C18 column (150 mm x 2.1 mm i.d., 5 microm), using a mobile phase of methanol/water with 0.1% formic acid (50:50, v/v) at a flow-rate of 200-300 microL/min in 4min. A Finngan LTQ tandem mass spectrometer equipped with electrospray ionization source was operated in the positive ion mode. Selective reaction monitoring was performed to quantify paeoniflorin and the internal standard at m/z transitions of 503-->381 and 411-->231, respectively. A good linearity was found in the range of 2-500 ng/mL (R(2)=0.9939). The intra- and inter-batch assay precisions (coefficient of variation, CV) at 5, 50 and 400 ng/mL (n=5) ranged from 6.3% to 9.7% and 1.2% to 7.2%, respectively, and the accuracies were from 95.9% to 101.6% and 99.4% to 102.9%, respectively. The mean recoveries of paeoniflorin were 81.2%, 80.9% and 82.3% at 5, 50 and 400 ng/mL (n=5), respectively, and the mean recovery of the internal standard was 76.7% with a concentration of 50 ng/mL (n=5). Stability studies showed that paeoniflorin was stable in different conditions. Finally, the method was successfully applied to the pharmacokinetic study of paeoniflorin in rat brain following a single subcutaneous administration (10 mg/kg) to rats. 相似文献
6.
Srinubabu G Patel RS Shedbalkar VP Rao AA Rao MN Bandaru VV 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,860(2):202-208
As a continuation of effort to improve our high flow on-line bioanalytical approach for high-throughput quantification of drugs and metabolites in plasma by high-throughput liquid chromatography tandem mass spectrometry (HTLC-MS/MS), we have developed a simple, sensitive and reliable method for simultaneous quantification of loratadine and desloratadine in human plasma. We have performed on-line coupling of extraction with Cyclone P 50 mm x 0.5 mm 50 microm HTLC column and chromatographic separation is performed with Zorbax XDB C18 50 mm x 2.1 mm 5 microm, followed by quantification with mass detector. The method is validated and showed good performances in terms of linearity, sensitivity, precision, accuracy and stability. A marked improvement in sample throughput efficiency is realized with this method and the proposed method will be useful for pharmacokinetic and/or bioequivalence studies. 相似文献
7.
Hsieh Y Duncan CJ Liu M 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,854(1-2):8-12
A novel mixed-mode high performance liquid chromatographic system (HPLC) interfaced with an atmospheric pressure chemical ionization (APCI) source and a tandem mass spectrometer (MS/MS) was developed for the determination of cytarabine (ara-C) in mouse plasma to support pharmacodynamic studies. The mixed-mode reversed-phase ion-exchange chromatography column was adapted for sufficient retention and separation of a small and polar analyte. The impact of the mobile phase composition on both chromatographic separation and the ionization efficiency of the test compound in the positive mode was investigated. The potential of ionization suppression from endogenous biological matrices on the mixed-mode LC-APCI/MS/MS method was evaluated using the post-column infusion technique. Furthermore, the feasibility of using the mixed-mode HPLC-MS/MS method for the determination of the plasma concentrations of cytarabine in mice was demonstrated by comparing those obtained by the ion-pairing HPLC-MS/MS method. 相似文献
8.
Tölgyesi A Sharma VK Fekete J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(5-6):403-410
A new method was developed to determine five corticosteroids (prednisolone, methylprednisone, flumethasone, dexamethasone, and methylprednisolone) in pig fat samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) utilizing an optimized liquid-liquid extraction (LLE) and subsequent solid-phase extraction (SPE) for sample clean-up. In the sample preparation, a pig fat sample was dissolved in n-hexane and then extracted into the methanol-water (50/50, v/v) mixture that enabled extraction of only medium polar corticosteroids and not the non-polar components of matrices. This extract was cleaned-up and concentrated on polymeric Oasis HLB SPE cartridge. Separation involved isocratic solvent (methanol-acetate buffer, pH 5.4) and Ascentis Express Fused-Core type HLPC column; reduced the analysis time to 7.5 min, which is at least two times lower than time required for separation using conventional techniques. Other advantage of the developed method is the minimized ion suppression of LC-MS/MS analysis, which allowed detection of corticosteroids in sub μg/kg. Method was validated according to European Union (EU) Commission Decision 2002/657/EC. Measured parameters such as selectivity, linearity, recovery, within-laboratory reproducibility, decision limit, and detection capability satisfied the EU Directive. Ranges of mean recoveries and within-laboratory reproducibility were 81-100% and 8.0-20.5%, respectively. Decision limits were calculated in the range from 4.5 to 11.9 μg/kg for MRL compounds and varied from 0.1 to 0.2 μg/kg for banned substances. Limit of detections (LODs), calculated as three time signal-to-noise ratio, were in the range of 0.1-0.3 μg/kg. 相似文献
9.
Liu Y Zhu R Li H Yan M Lei Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(26):2714-2719
A selective, simple and efficient method-ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for determination of two toxic alkaloids, namely strychnine and brucine in mice plasma. The UPLC separation was carried out using a 1.7 μm BEH C(18) column (50 mm × 2.1 mm) with a mobile phase consisting of methanol:0.1% formic acid (25:75, v/v), hence providing high efficiency, high resolution and excellent peak shape for the analytes and internal standard. The method was validated over the range of 2.48-496.4 ng/ml for strychnine and 2.64-528 ng/ml for brucine, respectively. Intra- and inter-day accuracy ranged from 95.0% to 107.9% for strychnine, 93.4% to 103.3% for brucine, and the precisions were within 13.8%. The extraction recoveries of both the two alkaloids exceed 81.9%. With a simple and minor sample preparation procedure and short run-time (<3 min), the proposed method was applicable for the pharmacokinetic and toxicological analysis of strychnine and brucine in vivo. 相似文献
10.
Wang C Riedl KM Schwartz SJ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(29):2949-2958
Folate deficiency is a prevalent phenomenon worldwide especially in underprivileged countries. Polyglutamyl 5-methyltetrahydrofolate (5MTHF) species are the naturally occurring principle folate in store-bought vegetables. Here we report a simple and complete extraction method for the determination of native polyglutamyl 5-methyltetrahydrofolate in vegetables using high performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). Coarsely chopped samples (18 different vegetables) were steamed to inactivate glutamylase enzymes and liberate folate from binding proteins and extracted in a reducing buffer with (13)C(5) 5MTHF stable isotope added as internal standard. The polyglutamyl 5-methyltetrahydrofolate species were separated in 9 min on a C(18) column using a reversed phase system. HPLC eluate was interfaced with a triple quadrupole mass spectrometer operated in electrospray positive mode. The respective pseudomolecular cation of each polyglutamyl 5-methyltetrahydrofolate species was selected for fragmentation to a common daughter ion for detection. We quantitated polyglutamyl 5-methyltetrahydrofolate in store-bought vegetables from families Brassicaceae, Asteraceae and Amaranthaceae (including mustard greens, romaine lettuce and Swiss chard) of which most have not been quantitated previously. Most vegetables from Asteraceae and those from Amaranthaceae contained similar amounts of monoglutamyl 5MTHF and polyglutamyl 5MTHF while Brassicaceae were dominated by polyglutamyls and endive species (Asteraceae) contained mainly monoglutamyl 5MTHF. The precision of the method for the various polyglutamyl 5-methyltetrahydrofolate forms was 1-9% RSD, recovery 84-91%, limit of detection 64-658 fmol and limit of quantitation 193-1994 fmol. Herein we describe a rapid, sensitive and selective HPLC-MS/MS technique to quantitate polyglutamyl 5-methyltetrahydrofolate species. This method may be suitable for analyzing the polyglutamyl 5-methyltetrahydrofolate profile of inherent folates in a wide range of leafy green vegetables. 相似文献
11.
Celli N Mariani B Dragani LK Murzilli S Rossi C Rotilio D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,810(1):129-136
Caffeic acid phenethyl ester (CAPE) is one of the most bioactive compounds of propolis, a resinous substance collected and elaborated by honeybees. A new liquid chromatography-electrospray ionisation tandem mass spectrometric method was developed and validated for its determination in rat plasma and urine, using taxifolin as internal standard. After sample preparation by liquid/liquid extraction with ethyl acetate, chromatographic separations were carried out with an ODS-RP column using a binary mobile phase gradient of acetonitrile in water. Detection was performed using a turboionspray source operated in negative ion mode and by multiple reaction monitoring. The method was validated, showing good selectivity, sensitivity (LOD = 1 ng/ml), linearity (5-1000 ng/ml; r > or = 0.9968), intra- and inter-batch precision and accuracy (< or =14.5%), and recoveries (94-106%) in both plasma and urine. Stability assays have shown that CAPE is rapidly hydrolysed by plasmatic esterases, which are however inhibited by sodium fluoride. The method was applied to the determination of CAPE levels in rat plasma and urine after oral administration, showing that CAPE is rapidly absorbed and excreted in urine both as unmodified molecule and as glucuronide conjugate. 相似文献
12.
Verhaeghe T Diels L de Vries R De Meulder M de Jong J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,789(2):337-346
Galantamine is an acetylcholinesterase inhibitor, recently approved for the treatment of mild-to-moderate Alzheimer's disease. To allow a higher throughput of samples, a new bioanalytical method for the determination of galantamine in human plasma was developed and validated. A stable isotope labelled internal standard was used. Sample preparation consisted of a simple one-step liquid-liquid extraction with toluene. The extracts were analysed with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS). The method was validated in the 1-500-ng/ml range. The accuracy, precision, selectivity, lower limit of quantification, upper limit of quantification, linearity and extraction recovery were evaluated, as well as the stability of the compound in plasma, blood, methanol and 2% BSA solutions under different conditions. The method proved very rugged during the analysis of large numbers of samples from clinical trials. 相似文献
13.
Zhang JY Fast DM Breau AP 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,787(2):333-344
A sensitive and specific liquid chromatography-tandem mass spectrometry assay was developed to quantify the first selective aldosterone blocker Eplerenone (I) and its hydrolyzed metabolite (II) in human plasma. The analytes (I, II) and their stable isotope-labeled analogues as internal standards were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was carried out on a narrow-bore reversed-phase Zorbax XDB-C(8) HPLC column with a mobile phase of acetonitrile/water (40:60, v/v) containing 10 mM ammonium acetate (pH 7.4). The analytes were ionized using negative-to-positive switch electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 415-->163 and m/z 431-->337 was used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-2500 ng/ml of plasma for both I and II. The lower limit of quantification was 10 ng/ml for I and II. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A throughput of 80 human plasma standards and samples per run was achieved with run time of 5 min for each injection. The assay has been successfully used in analyses of human plasma samples to support clinical studies. 相似文献
14.
Lin ZJ Abbas R Rusch LM Shum L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,788(1):159-166
Cromolyn sodium is a safe compound with potent anti-allergic properties when used locally or topically. Clinical data from systemic exposure is not available because of the poor GI absorption when given orally. In order to evaluate a new approach to enhance the absorption and bioavailability of cromolyn sodium, a sensitive assay was needed to support an oral-dose study in humans. This paper describes a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method for the analysis of cromolyn sodium in human plasma. The method consists of a two-step extraction with subsequent analysis using a high-performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a C(18) column followed by a backflush. The total run time is 6 min. The standard curve of cromolyn sodium was over the range of 0.313 to 750 ng/mL with a lower limit of quantitation (LLOQ) of 0.313 ng/mL when 0.5 mL of plasma was used for analysis. The percent coefficient of variation (C.V.) for accuracy and precision (inter-assay and intra-assay) was less than 15% over the validated concentration range and the coefficients of determination, r(2), were >0.991577. The method is simple, sensitive, and selective, and has been successfully utilized for oral cromolyn sodium clinical studies. 相似文献
15.
Tian L Huang Y Jia Y Hua L Li Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,865(1-2):127-132
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration. 相似文献
16.
Koji Kato Shigeji Jingu Naoyoshi Ogawa Shohei Higuchi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,740(2):25-193
A liquid chromatographic–tandem mass spectrometric method for the rapid quantitative determination of pibutidine, an H2-receptor antagonist, in human urine has been developed and validated over the concentration range 0.1–25.6 μg ml−1. Urine samples were prepared based on a simple dilution with 0.05% acetic acid, followed by reversed-phase liquid chromatographic separation. Pibutidine and its internal standard (2H10-pibutidine) were ionized using an electrospray ionization interface and detected by tandem mass spectrometry in the selected reaction-monitoring mode. Completed validation demonstrated the method to be robust, accurate, precise and specific for the direct quantification of pibutidine in human urine. This method has enabled investigation of the urinary excretion of pibutidine following oral administration of pibutidine hydrochloride to healthy subjects. 相似文献
17.
Bonato PS Lanchote VL Takayanagui OM 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,783(1):237-245
This paper describes a simple, fast, sensitive and reliable method for the simultaneous determination of albendazole sulfoxide (ASOX) and albendazole sulfone (ASON), the two most important metabolites of the drug albendazole (ABZ), in plasma samples using liquid chromatography and tandem mass spectrometry. After liquid-liquid extraction with dichloromethane, the two albendazole metabolites and the internal standard phenacetin were resolved in a CN column using the mobile phase methanol-water (4:6, v/v) acidified with 1% acetic acid. Detection by electrospray mass spectrometry was carried out in the positive ion mode. The method was linear up to 2500 and 250 ng/ml for ASOX and ASON, respectively, with mean recoveries of more than 85%. The precision and accuracy data, based on within- and between-day variations over 5 days, were lower than 15%. The quantitation limits of 0.5 and 5.0 ng/ml for ASON and ASOX are low enough for the method to be suitable for pharmacokinetic studies. Pharmacokinetic data obtained with the proposed method following oral administration of ABZ to a patient with neurocysticercosis are also reported. 相似文献
18.
Atzler D Mieth M Maas R Böger RH Schwedhelm E 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(23):2294-2298
Nitric oxide (NO), the endogenous modulator of vascular tone and structure, originates from oxidation of L-arginine catalysed by NO synthase (NOS). The L-arginine derivative L-homoarginine serves as an alternative NOS substrate releasing NO, competing with L-arginine for NOS, arginase, and arginine transport. In the present article we report a liquid chromatography-tandem mass spectrometric (LC-tandem MS) method for the determination of L-homoarginine in human plasma by stable-isotope dilution. L-[(13)C(6)]-Homoarginine was used as internal standard. This method provides high sample throughput of 25-μl aliquots of plasma with an analysis time of 4 min using LC-tandem MS electrospray ionisation in the positive mode (ESI+). Specific transitions for L-homoarginine and L-[(13)C(6)]-homoarginine were m/z 245 → m/z 211 and m/z 251 → m/z 217, respectively. The mean intra- and interassay CVs were 7.4 ± 4.5% (±SD) for 0.1-50 μmol/L and 7.5 ± 2.0% for 2 and 5 μmol/L, respectively. Applying this method, a mean plasma concentration of L-homoarginine of 2.5 ± 1.0 μmol/L was determined in 136 healthy humans. 相似文献
19.
Brkljačić L Sabalić M Salarić I Jerić I Alajbeg I Nemet I 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(32):3920-3926
Opiorphin, QRFSR-peptide, is a mature product of the PROL1 (proline rich, lacrimal 1) protein that showed beneficial effects in pain management, antidepressant-like actions as well as involvement in colonic motility and erectile physiology. Using opiorphin as a potential biomarker of different pathological states requires the development of robust and sensitive methods. We report a highly sensitive and specific liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) analytical method for the analysis of opiorphin in human saliva. Quantification was based on multiple reaction monitoring using characteristic transitions (m/z 347/120 - as quantifying ion; 347/175 and 347/268 as qualifying ions). The assay was linear in the range of 0-110 ng/ml and the lower limit of quantification reached was 1.0 ng/ml. The intra-day precision and accuracy were between 2.7-5.6% and -2.3 to 3.2%, respectively. The inter-day precision and accuracy were between 10.8-13.7% and -11.0 to 52%, respectively. Mean recovery was 106% and mean matrix effect was 0.97. Opiorphin in TFA treated saliva samples was stable for at least 12h at room temperature and up to 30 days at -20°C. Opiorphin levels in human saliva samples collected from young healthy individuals ranged from 2.8 to 25.9 ng/ml. 相似文献
20.
Lee HS Kang IM Lee HW Seo JH Ryu JH Choi SJ Lee MJ Jeong SY Cho YW Lee KT 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,863(1):158-162
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma. 相似文献