首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Takahashi Y  Yoshida K  Shimizu H 《Gerodontology》2012,29(2):e1086-e1091
doi: 10.1111/j.1741‐2358.2012.00616.x Fracture resistance of maxillary complete dentures subjected to long‐term water immersion Objective: This study investigated the fracture resistance of maxillary acrylic resin complete dentures subjected to long‐term water immersion. Materials and Methods: Maxillary acrylic resin complete dentures were fabricated from five denture base resins. Half of the dentures were stored in water for 50 h, and the other half were kept in water for 180 days before testing. Ten specimens were fabricated per group. The flexural load at the proportional limit (FL‐PL) of the dentures was tested. Results: A two‐way anova revealed a significant difference in FL‐PL because of the denture base material variable. There were no significant differences in FL‐PL because of the effect of water immersion and the interaction between the effect of water immersion and the denture base material. The FL‐PLs of the dentures fabricated with the two conventional heat‐processed resins, the pour‐type autopolymerizing resin and the microwave energy‐processed resin were not significantly different from each other; they were significantly higher than the light‐activated resin in regard to their FL‐PL. Conclusion: The FL‐PLs of the maxillary acrylic resin complete dentures did not change after long‐tern water immersion, and the FL‐PL of the denture fabricated from the light‐activated resin was lower than those of the other materials.  相似文献   

2.
doi: 10.1111/j.1741‐2358.2010.00385.x Glass fibre reinforced acrylic resin complete dentures: a 5‐year clinical study Background and objectives: The aim of the study was to establish the wear resistance of the glass fiber reinforced complete dentures comparative to the traditional acrylic complete dentures. Materials and methods: Complete new dentures were made to replace old fractured ‘un’‐reinforced acrylic dentures. The total number of dentures was 30 and woven E‐glass fibre reinforcements were used in maxillary complete dentures. Unidirectional E‐glass fibre reinforcements were used as partial fibre reinforcements in mandibular complete dentures. Ten complete acrylic un‐reinforced dentures were used as control. The follow‐up period was 5 years and the recalls were made at 6 months. Results: After 5 years of wearing the new dentures, the control dentures suffered seven fractures. After 5 years all the mandibular reinforced dentures were in good shape. The maxillary complete reinforced dentures suffered four partial fractures. Fracture lines were restricted by the glass fibre net and the patients could still use their dentures. Conclusion: Pre‐impregnated E‐glass fibre nets and polymer pre‐impregnated E‐glass unidirectional fibres are useful in reinforcing acrylic resin complete dentures especially were heavy occlusal forces are involved. Glass fibre reinforcement will be applied on the tension side in both cases (total fibre reinforcement and partial fibre reinforcement). The reinforcement cannot replace the necessary linings and occlusal adjustments.  相似文献   

3.
doi: 10.1111/j.1741‐2358.2012.00648.x Biometric ratio in estimating widths of maxillary anterior teeth derived after correlating anthropometric measurements with dental measurements Objective: To correlate dental measurements i.e. combined mesiodistal width of six maxillary anterior teeth with facial measurements i.e. inner canthal distance, interpupillary distance and intercommissural width and acquire a biometric ratio to serve as a preliminary guide in selection of the maxillary anterior teeth. Background: In the absence of pre‐extraction records, the resultant denture can lead to patient dissatisfaction towards the aesthetic appeal of their dentures. The maxillary anterior teeth play a pivotal role in denture aesthetics. Various techniques and biometric ratios have been described in literature for selection of the maxillary anteriors. This study derives a biometric ratio for the same, obtained after correlating anthropometric measurements with dental measurements. Materials and methods: Two standardized digital photographs of the face were generated; one, when the facial muscles were relaxed and the other, when the subject was smiling; thereby, revealing the maxillary anterior teeth upto the canine tip. Inner canthal distance, interpupillary distance, intercommissural distance, distance between the tips of the maxillary canines and distance between the distal surfaces of the canines were measured. On the cast, the distance between tips of maxillary canines and distance between distal surfaces of maxillary canines were noted. The data was analysed using Spearman’s rank correlation coefficient. Results: A high correlation was found between the intercommissural measurement with distance between the tips of the canines on the photograph and between the tips of the canines on the cast with the interpupillary distance, giving a biometric ratio of 1:1.35 and 1:1.41 respectively. The least correlation was between the inner canthal distance and the tips of the canines measured on the photograph. Conclusions: Extra oral anthropometric measurements of the interpupillary distances and the intercommissural distances with the help of standardised photographs can help us determine the combined widths of the anterior teeth accurately, thus aiding their selection in the absence of pre‐extraction records.  相似文献   

4.
doi: 10.1111/j.1741‐2358.2011.00567.x Evaluation of the occlusion vertical dimension of complete dentures after microwave disinfection Objectives: An increase in occlusal vertical dimension (OVD) after microwave disinfection may result in the need for adjustments in the complete dentures. This in vitro study evaluated the increase in OVD of maxillary complete dentures submitted to microwave disinfection protocols. Material and methods: Thirty sets of complete dentures were evaluated as follows: Group 1–15 sets had the maxillary complete dentures submitted to microwave disinfection (650 W/3 min), once a week, for 4 weeks. Group 2–15 sets had the maxillary complete dentures submitted to microwave disinfection (650 W/3 min), three times a week, for 4 weeks. The vertical dimension was measured with a micrometre (in mm) before disinfection protocols (baseline readings) and after each week of disinfection. Data were analysed using Wilcoxon and Friedman tests (α = 0.05). Results: For Group 1, no significant difference was found between the increases in OVD and zero, and no significant difference was found between the weeks. For Group 2, the increases in OVD were significantly greater than zero, and the Friedman test showed that weeks 3 and 4 had significantly greater changes than week 1 and that week 4 had significantly greater change than week 2. Conclusion: Microwave disinfection only promoted significant increase in OVD in Group 2, in which the values increased progressively.  相似文献   

5.
doi: 10.1111/j.1741‐2358.2011.00587.x The influence of double flask investing on tooth displacement in dentures processed by microwave irradiation Objective: This study evaluated the influence of the bimaxillary flask (BMF) and two different investing materials on first molar inclination in dentures processed by microwave irradiation. Background: The BMF may minimise tooth displacement, saving time and improving occlusion. Methods and materials: Forty pairs of dentures were randomised into four groups: stone wall in monomaxillary flask; silicone wall in BMF; stone wall in BMF; acrylic resin retentions and silicone in BMF. Dentures were processed by microwave irradiation. Two referential points were established on tooth surface. A microscope and a digital pachymeter were used to measure the distance between these points, and the angles α (right maxillary molar), β (left maxillary molar), α′ (right mandibular molar) and β′ (left mandibular molar) were calculated by the law of cosines. Data were submitted to Kruskal–Wallis (5% significance). Results: No difference was observed among the groups (p > 0.05). In the intra‐group analysis, α was significantly different for groups I, II and III; α′, for groups II and IV; β, for all groups; β′, for groups III and IV. Conclusion: First molar inclination was similar for monomaxillary and BMFs. The use of stone or silicone as investing materials presented the same effect on tooth inclination.  相似文献   

6.
The undecalcified bone specimen was surfaced by an ordinary motor-driven circular saw. After thorough drying in air, the specimen was infiltrated with melted Caulk sticky wax (L. D. Caulk Co., Milford, Del., 19963) without casting in a block. The specimen was affixed to the Gillings-Hamco thin-sectioning machine with cut surface parallel to the circular diamond blade. Prior to sawing each section, the specimen surface was blown dry and coated with a thin supporting layer of stick wax. The section was then attached to an albumen-coated glass slide with the newly cut surface facing the slide. After drying in room temperature, the slide was soaked in xylene to partially dissolve the sticky wax, and the loosened residue was removed subsequently by gentle brushing. The section was mounted and covered with a coverglass. Sections 50-100 μ thick were prepared satisfactorily by this method. The advantages of using sticky wax as an infiltration medium depend on its physical properties: it is gluey when melted, and holds the bony trabeculae together; it becomes hard and nonsticky at room tempperature, and can be sawed together with bone tissue. Since a new layer of wax blends readily with the old wax surface, it allows the important supportive coating of wax to be added to the sawing surface for each section cutting  相似文献   

7.
doi: 10.1111/j.1741‐2358.2010.00392.x Influence of different metal flask systems on tooth displacement in complete upper dentures Objective: To verify the occurrence of tooth displacement in dentures processed by moist hot‐polymerisation using traditional and experimental metal flask systems. Materials and methods: Waxed complete dentures were randomly assigned to three groups (n = 10), including traditional (TF) and experimental flasks (DF and HHF). Metal pins were placed at the incisal edge of maxillary central incisors (I), buccal cusp of first premolars (P) and mesiobuccal cusp of second molars (M). Transversal (I–I, P–P and M–M) and anteroposterior (LI–LM and RI–RM) distances were measured before and after denture processing using an optical microscope. The dentures were processed by hot water curing cycle (9 h/74°C). Collected data were analysed by anova , Paired Student’s t‐test and Holm–Sidak method (p < 0.05). Results: All measured distances demonstrated contraction after polymerisation, except for LI–LM in TF and RI–RM in DF and HHF. Statistically significant differences were found between the distances P–P for DF and HHF, and M–M for all groups. Comparison among flask systems revealed statistically significant difference in the P–P distance for the TF and HHF. Conclusion: Different flask systems did not cause variation in tooth displacement during denture processing, with the exception of P–P distances for the TF and HHF. There is no evidence that different metal flask systems would promote tooth displacement of clinical significance.  相似文献   

8.
doi:10.1111/j.1741‐2358.2009.00298.x
Use of resin‐bonded extracoronal attachments with removable partial denture: case report Introduction: Resin‐bonded extracoronal attachments may be indicated for the abutment teeth of removable partial dentures, especially for anterior teeth when a cingulum rest must be provided. This type of treatment has a series of advantages such as minimal tooth reduction, supragingival margins, favourable stress distribution, and improved aesthetic appearance. Objective: To report a clinical case of oral rehabilitation using a combination of resin‐bonded extracoronal attachments joined by a Dolder bar with a removable partial denture. Case report: A 60‐year‐old male patient with only the canines in the maxillary arch was restored with a combination of resin‐bonded extracoronal attachments joined by a Dolder bar and a removable partial denture. Conclusion: Dentures with resin‐bonded extracoronal attachments can have a number of advantages over traditional clasp‐retained removable partial dentures.  相似文献   

9.
Kurt M  Saraç YŞ  Ural C  Saraç D 《Gerodontology》2012,29(2):e357-e362
doi: 10.1111/j.1741‐2358.2011.00480.x
Effect of pre‐processing methods on bond strength between acrylic resin teeth and acrylic denture base resin Objectives: This study evaluated the effects of various pre‐processing methods on the bond strength between resin and denture teeth. Backgrounds: Debonding of acrylic resin teeth from denture base material is a problem for patients wearing complete dentures. Materials and Methods: Four experimental groups (n = 30) were investigated by subjecting tooth–resin bonding to tensile loading. Specimens were prepared and tested according to the methods of the International Standards Organization (ISO 22112:2005) using a special assembly. Four pre‐processing surface treatments of teeth were applied: (i) ST1, no treatment applied (control); (ii) ST2, wax solvent (Dewaks, Faber Kimya & Ilaç, Turkey); (iii) ST3, boiling water followed by conditioning with methyl methacrylate (MMA) monomer (Meliodent, Bayer Dental, Germany); (iv) ST4, boiling water followed by wax solvent agent and finally MMA monomer application. Bond strength test was performed using a universal testing machine. Results: All the strength values of the test groups were within clinically acceptable limits. The lowest values were from the ST1 group and the highest values were in the ST4 group. Conclusions: Wax elimination methods affected bonding strength. Application of wax solvent and MMA monomer to the ridge lap surfaces of the teeth gave the best results. In clinical practice, this application procedure may decrease the bonding failure of denture teeth.  相似文献   

10.
doi: 10.1111/j.1741‐2358.2011.00494.x
Effect of double flasking and investing methods on artificial teeth movement in complete dentures processing Purpose: The aim of this study was to evaluate linear dimensional alterations of artificial teeth for complete dentures when using different investment and flasking techniques. Background: Dimensional changes in the vertical dimension may occur owing to changes in artificial teeth positioning caused by different investing and flasking techniques. Materials and methods: Thirty pairs of the complete dentures were manufactured and randomly divided into three groups (n = 10): (1) invested with type III stone in monomaxillary PVC flask; (2) invested with type III stone in bimaxillary PVC flask; and (3) invested with laboratory silicone in bimaxillary PVC flask. Dentures were polymerised by microwave, and 12 linear distances were measured before and after denture processing. Data were analysed by one‐way anova , considering manufacturing technique as the study factor. Tukey’s HSD was used as post hocanova (p = 0.05). Results: Most of the linear distances were comparable for all groups. All transversal maxillary and mandibular distances were higher for group 1 compared with groups 2 and 3 (p < 0.05), except the distance 3–6 for mandibular arch, in which no difference was found between groups (p < 0.05). Both maxillary diagonal distances were higher in group 1 (p < 0.05), and no differences were found among all groups for mandibular measurements. Conclusions: Double flasking technique independent on the investment material is shown to be the most effective method to reduce changes in artificial teeth positioning.  相似文献   

11.
doi:10.1111/j.1741‐2358.2009.00308.x
Effects of home and office care denture reliners on maxillary complete dentures Objectives: The aim of this study was to evaluate the effects of office (OR) and home (HR) care temporary denture reliners on satisfaction and functional outcomes in maxillary complete denture wearers. Methods: Thirty‐four maxillary edentulous patients received application of either OR or HR to their maxillary complete dentures. Patient’s ratings on satisfaction and functional aspects were measured on a 100‐mm visual analogue scale at 4 days post‐application. Associations between baseline ratings and improvement were also assessed. Results: There were no significant differences between the two groups in satisfaction ratings or in the functional outcomes. The OR group showed a significant improvement in mastication and retention, whereas the HR group exhibited a significant improvement in general satisfaction and mastication. Improvement was negatively associated with baseline ratings of speech, ease of cleaning, stability and retention in the OR groups and across all variables, except ease of cleaning, in the HR group. Conclusion: When used correctly, home care denture therapy can be as effective as office applied temporary liner in improving satisfaction with problematic maxillary dentures.  相似文献   

12.
doi: 10.1111/j.1741‐2358.2011.00551.x
Complete denture wearing and fractures among edentulous patients treated in university clinics Objective: The prevalence of wearing and fracture of complete dentures was evaluated among edentulous patients treated in two dental schools in Brazil. Background: Acceptance and wearing of complete dentures are related to adaptive behaviour of edentulous patients. However, one reason that could interfere with the wearing dentures is their potential to fracture, which is still a common complication in denture rehabilitation practice. Material and methods: Two hundred and twenty‐four edentulous patients rehabilitated with complete dentures from 2000 to 2005 in Araçatuba and Araraquara Dental School, University of State of São Paulo, were assessed in 2006 and 2007 to answer a questionnaire about wearing and fracture of their dentures. Statistical analysis were performed using Epi Info software and chi‐squared test to compare maxillary and mandibular data (α = 0.05). Results: Almost 26% of the patients did not wear their dentures, and among the remainder, the majority wore the maxillary denture. About 30% of the dentures were fractured, with higher prevalence in the maxillary arch (p = 0.003). Conclusions: Discontinuation of wearing dentures was quite high, especially considering the treatment which was carried out in university clinics. Prevalence of fractures was also high, greater for the maxillary denture, and was one of the main reasons for non‐wearing of complete dentures.  相似文献   

13.
doi: 10.1111/j.1741‐2358.2010.00389.x The effect of different attachment systems with implant‐retained overdentures on maximum bite force and EMG Objective: To compare the effect of different attachment systems with implant‐retained overdentures on maximum bite force and muscle activity using electromyography (EMG). Background: Denture retention and stability is of considerable interest in prosthetic dentistry. Materials and methods: Thirty‐five patients were examined: 15 edentulous patients treated with mandibular implant‐retained overdentures (MIRO) and maxillary dentures (MCD) (two implant‐ball attachment) (BC); 10 edentulous patients treated with MIRO and MCD (four implants‐bar attachments) (BRC); 10 patients with edentulous mandibular treated with MIRO and maxillary fixed partial dentures (MFPD) (two implant‐ball attachments) (BF). Before implant placement all patients received new dentures. After using these dentures for 3 months the maximum bite force and electrical activity of masseter muscle were measured. Two or four implants were then inserted into the intraforaminal region. After osseointegration periods, patients were treated with MIRO which duplicated their dentures and after three months the measurements were repeated. The data were collected and statistically analysed. Results: Muscle activity and chewing ability increased in the second period of measurements. Also chewing time was significantly decreased at the first measurements. The highest muscle activity was observed in the group of patients treated with group BF. Conclusion: The EMG values of the masseter muscle significantly increased when an implant attachments was used in the overdenture.  相似文献   

14.
目的:研究通过比较不同的排牙方式制作的全口义齿对咀嚼次数、咀嚼效率以及患者的主观感受的影响。方法:78例无牙颌患者按照牙槽嵴高度分为正常组和低平组,正常组有患者32例,低平组有患者46例,每组分别戴用上颌起排法和下颌起排法制作的全口义齿,比较咀嚼次数、咀嚼效率和满意度的差别。结果:在戴用上颌起排法制作的全口义齿时,正常组的咀嚼次数高于低平组,差异具有统计学意义(t=3.60,P0.05);戴用下颌起排法制作的全口义齿后,低平组的咀嚼次数高于采用上颌起排法的全口义齿,差异具有统计学意义(t=4.41,P0.05);在戴用上颌起排法制作的全口义齿中,正常组的咀嚼效率高于低平组,差异具有统计学意义(t=5.72,P0.05);而在戴用下颌起排法制作的全口义齿后,低平组的咀嚼效率高于采用上颌起排法的全口义齿,差异具有统计学意义(t=7.16,P0.05)。正常组认为使用下颌起排法制作全口义齿咀嚼能力、稳固感好于上颌起排法,差异均具有统计学意义(P0.05);低平组认为使用下颌起排法制作全口义齿咀嚼能力、稳固感和舒适感好于上颌起排法,差异均具有统计学意义(P0.05)。结论:对于牙槽嵴低平无牙颌患者使用下颌起排法制作的全口义齿,能够有效地增强咀嚼效率,提高义齿的稳定性。  相似文献   

15.
Candida biofilms adhere to the internal surface of removable dentures, which is an etiological factor in the pathogenesis of denture stomatitis (DS). Adhesive materials are used at the base of maxillary complete dentures to improve their retention and chewing qualities. This article reports the antimicrobial activity of the enriched fractions of Equisetum giganteum and Punica granatum incorporated into a denture adhesive against C. albicans biofilm. The biofilms were induced on the surface of heat-cured acrylic resin specimens that were previously treated with a mixture of adhesive/herb extracts. The antimicrobial activity was evaluated by CFU counts, XTT reduction, and SEM and CLSM analysis. Both herb extracts amplified the anti-biofilm action of the adhesive on the acrylic resin by up to 12 h. Therefore, when these extracts were combined with COREGA®, they played a collaborative and innovative role in biofilm control and can be considered alternatives for temporary use in the treatment and/or prevention of DS.  相似文献   

16.
Background: Failure of bonding between acrylic resin teeth and denture base material is a considerable problem for patients who wear complete dentures. Objective: The purpose of this study was to evaluate the bond strength between acrylic resins and resin denture teeth with different thermocycling and polymerisation methods. Materials and methods: Microwave‐polymerised (Onda‐Cryl), heat‐polymerised (Clássico) and autopolymerising (Jet) acrylic resins and resin denture tooth (Biotone) were used. The acrylic resins were polymerised according to the following: (A) microwave – fast cycle, Onda‐Cryl; (B) microwave – long cycle, Onda‐Cryl; (C) microwave – manufacturer’s cycle, Onda‐Cryl; (T) water bath – long cycle, Clássico; and (Q) bench polymerisation cycle, Jet. Twenty specimens were prepared for each polymerisation method. Ten were thermocycled, and 10 did not receive thermocycling. For the purpose of the study, a shear test was used. Data were analysed with the Kruskal–Wallis test and Dunn’s multiple comparisons test (p = 0.05). Results: Cycles B, C and T were similar (p > 0.05), and had statistically higher bonding values than cycles A and Q (p < 0.05) for the thermocycled and non‐thermocycled groups. For all cycles, there were no statistically significant differences between thermocycled and non‐thermocycled groups (p > 0.05), except for cycle Q (p = 0.0038). Conclusion: Thermocycling decreased the bond strength, but not significantly for microwave and heat‐polymerised cycles. Regarding the bond strength of denture teeth to acrylic resin, the fast microwave polymerisation cycle should be avoided when polymerising Onda‐Cryl acrylic resin. In addition, Jet acrylic resin is not adequate for use in denture repair.  相似文献   

17.
ObjectivesTo apply contact measurement and reference point system (RPS) alignment techniques to establish a method for 3D reconstruction of the edentulous jaw models with centric relation and to quantitatively evaluate its accuracy.MethodsUpper and lower edentulous jaw models were clinically prepared, 10 pairs of resin cylinders with same size were adhered to axial surfaces of upper and lower models. The occlusal bases and the upper and lower jaw models were installed in the centric relation position. Faro Edge 1.8m was used to directly obtain center points of the base surface of the cylinders (contact method). Activity 880 dental scanner was used to obtain 3D data of the cylinders and the center points were fitted (fitting method). 3 pairs of center points were used to align the virtual model to centric relation. An observation coordinate system was interactively established. The straight-line distances in the X (horizontal left/right), Y (horizontal anterior/posterior), and Z (vertical) between the remaining 7 pairs of center points derived from contact method and fitting method were measured respectively and analyzed using a paired t-test.ResultsThe differences of the straight-line distances of the remaining 7 pairs of center points between the two methods were X: 0.074 ± 0.107 mm, Y: 0.168 ± 0.176 mm, and Z: −0.003± 0.155 mm. The results of paired t-test were X and Z: p >0.05, Y: p <0.05.ConclusionBy using contact measurement and the reference point system alignment technique, highly accurate reconstruction of the vertical distance and centric relation of a digital edentulous jaw model can be achieved, which meets the design and manufacturing requirements of the complete dentures. The error of horizontal anterior/posterior jaw relation was relatively large.  相似文献   

18.
doi: 10.1111/j.1741‐2358.2012.00658.x Survival analysis of mandibular complete dentures with acrylic‐based resilient liners Objective: The purpose of this long‐term randomised controlled trial was to compare the longevity of dentures constructed using a conventional acrylic resin (CAR) to that of dentures constructed using an acrylic‐based resilient liner (ARL). Materials and methods: The follow‐up study was essentially carried out by annual telephone calls to each of the 67 participants. The Kaplan–Meier method and life‐table analysis were used for univariate analyses. The Cox proportional‐hazards test was used as a final model for statistically adjusting predictor variables such as sex, clinician type, mandibular denture type and age at denture delivery. Results: The denture type was likely to affect the survival time of the dentures, while the sex and clinician type were not. The group using acrylic‐based resilient denture liners had twice the risk of having shorter denture‐survival times than those using conventional acrylic resin dentures. Younger participants were likely to have a reduced risk of having shorter denture‐survival times than older participants. Conclusion: We conclude that mandibular complete dentures constructed using ARL are twice as likely as dentures constructed using CAR to have shorter denture survival times, mainly because of material deterioration.  相似文献   

19.
Background: The microwave energy is an efficient disinfection method; however, it can generate high temperatures that can result in distortion of the dentures. objectives: To evaluate whether the addition of an enzymatic cleanser to microwave disinfection regimen would disinfect dentures with shorter irradiation time. Materials and methods: Seven resin discs colonized with Candida albicans biofilm were placed on the palatal surface of sterile dentures to be randomly assigned to the following treatments: immersion in distilled water for 3 min with 0 (DW), 1 (DW + M1), 2 (DW + M2), or 3 min (DW + M3) of microwave irradiation; or immersion in denture cleanser for 3 min with 0 (DC), 1 (DC + M1), 2 (DC + M2) or 3 min (DC + M3) of irradiation. After the treatments, the viable cells were counted by a blinded examiner. The temperature was measured immediately after irradiation. The data were analyzed by ANOVA and Tukey post hoc tests (α = 0.05). Results: No viable cells were found after DC + M2, DC + M3, and DW + M3 treatments, of which DC + M2 achieved the lowest temperature. No significant difference was found between the effectiveness of DW, DW + M1 and DC treatments (p > 0.05). Conclusion: Within the limits of this study, the association of a denture cleanser and microwave energy is efficient to disinfect dentures in lower irradiation time and temperature.  相似文献   

20.
The melaleuca psyllid, Boreioglycaspis melaleucae (Hemiptera: Psyllidae), was introduced to Florida as a biological control agent against Melaleuca quinquenervia, an invasive evergreen tree that has invaded large areas of Florida Everglades. Colonies of B. melaleucae nymphs are normally covered by white waxy secretions, and nymphs of various instars produce long bundles of white waxy filaments extending laterally and posteriorly from their abdomen. Scanning electron microscopy of ‘naturally waxed’ and ‘dewaxed’ nymphs (cleaned from wax) revealed two types of wax pore plates located dorsally and laterally on the integument of posterior abdominal segments starting with the 4th segment. Type-1 wax pore plates, with raised rim, peripheral groove, slits and pits, produce long ribbons and filaments of waxy secretions that are wound together forming long wax bundles, whereas type-2 wax pore plates, with slits only, produce shorter wax curls. Additionally, in both nymphs and adult females, the circumanal ring contained ornate rows of wax pores that produce wax filaments covering their honeydew excretions. Video recordings with stereomicroscopy showed that adult females produce whitish honeydew balls, powerfully propelled away from their body, probably to get these sticky excretions away from their eggs and newly hatched nymphs. Adult males, however, produce clear droplets of honeydew immediately behind them, simply by bending the posterior end of the abdomen downward. The possible role(s) of waxy secretions by nymphs and adults of B. melaleucae in reducing contamination of their colonies with honeydew, among other possibilities, are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号