1.
In this study we systematically analyzed the elution condition of tryptic peptides and the characteristics of identified peptides in reverse phase liquid chromatography and electrospray tandem mass spectrometry (RPLC-MS/MS) analysis. Following protein digestion with trypsin, the peptide mixture was analyzed by on-line RPLC-MS/MS. Bovine serum albumin (BSA) was used to optimize acetonitrile (ACN) elution gradient for tryptic peptides, and Cytochrome C was used to retest the gradient and the sensitivity of LC-MS/MS. The characteristics of identified peptides were also analyzed. In our experiments, the suitable ACN gradient is 5% to 30% for tryptic peptide elution and the sensitivity of LC-MS/MS is 50 fmol.Analysis of the tryptic peptides demonstrated that longer (more than 10 amino acids) and multi-charge state ( 2, 3) peptides are likely to be identified, and the hydropathicity of the peptides might not be related to whether it is more likely to be identified or not. The number of identified peptides for a protein might be used to estimate its loading amount under the same sample background. Moreover, in this study the identified peptides present three types of redundancy, namely identification, charge, and sequence redundancy, which may repress low abundance protein identification.  相似文献   

2.

Background  

Often high-quality MS/MS spectra of tryptic peptides do not match to any database entry because of only partially sequenced genomes and therefore, protein identification requires de novo peptide sequencing. To achieve protein identification of the economically important but still unsequenced plant pathogenic oomycete Plasmopara halstedii, we first evaluated the performance of three different de novo peptide sequencing algorithms applied to a protein digests of standard proteins using a quadrupole TOF (QStar Pulsar i).  相似文献   

3.
The objective of this study was to determine if liquid chromatography mass spectrometry (LC/MS) data of tryptic digests of proteins can be used for quantitation. In theory, the peak area of peptides should correlate to their concentration; hence, the peak areas of peptides from one protein should correlate to the concentration of that particular protein. To evaluate this hypothesis, different amounts of tryptic digests of myoglobin were analyzed by LC/MS in a wide range between 10 fmol and 100 pmol. The results show that the peak areas from liquid chromatography mass spectrometry correlate linearly to the concentration of the protein (r2 = 0.991). The method was further evaluated by adding two different concentrations of horse myoglobin to human serum. The results confirm that the quantitation method can also be used for quantitative profiling of proteins in complex mixtures such as human sera. Expected and calculated protein ratios differ by no more than 16%. We describe a new method combining protein identification with accurate profiling of individual proteins. This approach should provide a widely applicable means to compare global protein expression in biological samples.  相似文献   

4.
The proposed model is based on the measurement of the retention times of 346 tryptic peptides in the 560- to 4,000-Da mass range, derived from a mixture of 17 protein digests. These peptides were measured in HPLC-MALDI MS runs, with peptide identities confirmed by MS/MS. The model relies on summation of the retention coefficients of the individual amino acids, as in previous approaches, but additional terms are introduced that depend on the retention coefficients for amino acids at the N-terminal of the peptide. In the 17-protein mixture, optimization of two sets of coefficients, along with additional compensation for peptide length and hydrophobicity, yielded a linear dependence of retention time on hydrophobicity, with an R2 value about 0.94. The predictive capability of the model was used to distinguish peptides with close m/z values and for detailed peptide mapping of selected proteins. Its applicability was tested on columns of different sizes, from nano- to narrow-bore, and for direct sample injection, or injection via a pre-column. It can be used for accurate prediction of retention times for tryptic peptides on reversed-phase (300-A pore size) columns of different sizes with a linear water-ACN gradient and with TFA as the ion-pairing modifier.  相似文献   

5.
The electron density maps of the catalase-peroxidase from Burkholderia pseudomallei (BpKatG) presented two unusual covalent modifications. A covalent structure linked the active site Trp111 with Tyr238 and Tyr238 with Met264, and the heme was modified, likely by a perhydroxy group added to the vinyl group on ring I. Mass spectrometry analysis of tryptic digests of BpKatG revealed a cluster of ions at m/z 6585, consistent with the fusion of three peptides through Trp111, Tyr238, and Met264, and a cluster at m/z approximately 4525, consistent with the fusion of two peptides linked through Trp111 and Tyr238. MS/MS analysis of the major ions at m/z 4524 and 4540 confirmed the expected sequence and suggested that the multiple ions in the cluster were the result of multiple oxidation events and transfer of CH3-S to the tyrosine. Neither cluster of ions at m/z 4525 or 6585 was present in the spectrum of a tryptic digest of the W111F variant of BpKatG. The spectrum of the tryptic digest of native BpKatG also contained a major ion for a peptide in which Met264 had been converted to homoserine, consistent with the covalent bond between Tyr238 and Met264 being susceptible to hydrolysis, including the loss of the CH3-S from the methionine. Analysis of the tryptic digests of hydroperoxidase I (KatG) from Escherichia coli provided direct evidence for the covalent linkage between Trp105 and Tyr226 and indirect evidence for a covalent linkage between Tyr226 and Met252. Tryptic peptide analysis and N-terminal sequencing revealed that the N-terminal residue of BpKatG is Ser22.  相似文献   

6.
This report describes an integrated and modular microsystem providing rapid analyses of trace-level tryptic digests for proteomics applications. This microsystem includes an autosampler, a microfabricated device comprising a large channel (2.4 microl total volume), an array of separation channels, together with a low dead volume enabling the interface to nanoelectrospray mass spectrometry. The large channel of this microfluidic device provides a convenient platform to integrate C(18) reverse phase packing or other type of affinity media such as immobilized antibodies or immobilized metal affinity chromatography beads thus enabling affinity selection of target peptides prior to electrophoretic separation and mass spectrometry analyses on a quadrupole/time-of-flight instrument. Sequential injection, preconcentration, and separation of peptide standards and tryptic digests are achieved with a throughput of up to 12 samples/per h and a concentration detection limit of approximately 5 nM (25 fmol on chip). Replicate injections of peptide mixtures indicated that reproducibility of migration time was 1.2-1.8%, whereas relative standard deviation ranging from 9.2 to 11.8% are observed on peak heights. The application of this device for trace-level protein identification is demonstrated for two-dimensional gel spots obtained from extracts of human prostatic cancer cells (LNCap) using both peptide mass-fingerprint data base searching and on-line tandem mass spectrometry. Enrichment of target peptides prior to mass spectral analyses is achieved using c-myc-specific antibodies immobilized on protein G-Sepharose beads and facilitates the identification of antigenic peptides spiked at a level of 20 ng/ml in human plasma. Affinity selection is also demonstrated for gel-isolated protein bands where tryptic phosphopeptides are captured on immobilized metal affinity chromatography beads and subsequently separated and characterized on this microfluidic system.  相似文献   

7.
Proteomic workflows involving liquid-based protein separations are an alternative to gel-based protein analysis, however the trypsin digestion procedure is usually difficult to implement, particularly when processing low abundance proteins from capillary column effluent. To convert the protein to peptides for the purpose of identification, current protocols require several sample handling steps, and sample losses become an issue. In this study, we present an improved system that conducts reversed-phase protein chromatography and rapid on-line tryptic digestion requiring sub-nanogram quantities of protein. This system employs a novel mirror-gradient concept that allows for dynamic titration of the column effluent to create optimal conditions for real-time tryptic digestion. The purpose behind this development was to improve the limits of detection of the online concept, to support flow-based alternatives to gel-based proteomics and to simplify the characterization of low abundance proteins. Using test mixtures of proteins, we show that peptide mass fingerprinting with high sequence representation can be easily achieved at the 20 fmol level, with detection limits down to 5 fmol (85 pg myoglobin). Limits of identification using standard data-dependent MS/MS experiments are as low as 10 fmol. These results suggest that the nanoLC-trypsin-MS/MS system could represent an alternative to the conventional "1D-gel to MS" proteomic strategy.  相似文献   

8.
Garaguso I  Borlak J 《Proteomics》2008,8(13):2583-2595
The analytical performance of MALDI-MS is highly influenced by sample preparation and the choice of matrix. Here we present an improved MALDI-MS sample preparation method for peptide mass mapping and peptide analysis, based on the use of the 2,5-dihydroxybenzoic acid matrix and prestructured sample supports, termed: matrix layer (ML). This sample preparation is easy to use and results in a rapid automated MALDI-MS and MS/MS with high quality spectra acquisition. The between-spot variation was investigated using standard peptides and statistical treatment of data confirmed the improvement gained with the ML method. Furthermore, the sample preparation method proved to be highly sensitive, in the lower-attomole range for peptides, and we improved the performance of MALDI-MS/MS for characterization of phosphopeptides as well. The method is versatile for the routine analysis of in-gel tryptic digests thereby allowing for an improved protein sequence coverage. Furthermore, reliable protein identification can be achieved without the need of desalting sample preparation. We demonstrate the performance and the robustness of our method using commercially available reference proteins and automated MS and MS/MS analyses of in-gel digests from lung tissue lysate proteins separated by 2-DE.  相似文献   

9.
Protein identification by interrogation of databases requires a comprehensive compilation of modified amino acids forms. Here, we describe the chemical oxidation of carboxyamidomethyl cysteine to the sulfoxide and sulfone forms, species that may add more complexity to peptide analyses. They can be easily distinguished by tandem mass spectrometry (MS/MS) due to their characteristic pattern of side chain neutral eliminations either from the parent ion or ion series that generate dehydroalanine as detected by MS(3). This finding was supported by the MS(n) spectra recorded for a peptide isolated from a mixture of tryptic peptides and for a derivatized/oxidized synthetic peptide with a different sequence. These modifications and their diagnostic neutral losses should be included in the list of chemical modifications and in algorithms designed for the automatic sequencing of peptides and database searching.  相似文献   

10.
The assignment of the five disulfide bridges in an alpha-amylase monomeric inhibitor from wheat kernel (coded 0.28) was achieved by combining fast-atom-bombardment mass spectrometry (FAB-MS) and automatic sequencing based on Edman degradation. Direct FAB-MS analysis of the native and reduced enzymatic digests of the protein allowed the assignment of three disulfide bridges out of five, including those involving two adjacent cysteine residues. The remaining two disulfide bridges were assigned by sequencing automatically the peptide clusters purified from the tryptic digest of the native protein.  相似文献   

11.
Several forms of diacetyl-reducing enzyme were found to exist in the human liver cytosol. Three (DAR-2, DAR-5, and DAR-7) of them were purified as a single band on SDS-PAGE by a combination of a few kinds of column chromatographies. The in-gel tryptic digests of the purified enzymes were analyzed by nano-liquid chromatography (LC)/Fourier transform ion cyclotron resonance mass spectrometry (FT ICR MS), which provided peptide masses at a ppm-level accuracy. The enzymes, DAR-2, DAR-5, and DAR-7, were identified as alcohol dehydrogenase beta subunit (ADH2), carbonyl reductase (CBR1), and aldehyde reductase (AKR1A1), respectively, by peptide mass fingerprinting. In addition, an alternating-scan acquisition of nano-LC/FT ICR mass spectra, i.e., switching of normal acquisition conditions and in-source fragmentation conditions scan by scan, provided sets of parent and fragment ion masses of many of the tryptic peptides in a single LC/MS run. The peptide sequence-tag information at the ppm-level accuracy was used to further confirm the protein identities. It was demonstrated that nano-LC/FT ICR MS can be used for rigorous protein identification at a subpicomole level as an alternative technique to nano-LC/MS/MS.  相似文献   

12.
Appropriate methods for the analysis of microdissected solid tumour tissues by matrix-assisted laser desorption/ionisation-time of flight-mass spectrometry (MALDI-TOF MS) are not yet well established. Optimisation of sample preparation was performed first on undissected tissue slices, representing approximately 200 000 cells, which were solubilised either in urea containing buffer, trifluoroethanol/NH4HCO3, 0.1% sodium dodecyl sulphate (SDS) or in 0.1% RapiGest solution, then trypsin digested and analysed by MALDI-TOF MS. Solubilisation in 0.1% SDS resulted in detection of the highest number of sample specific peak signals. Interestingly, there was little overlap in detectable peaks using the different buffers, implying that they can be used complementarily to each other. Additionally, we fractionated tryptic digests on a monolithic high-performance liquid chromatography column. Fractionation of tryptic digest from whole tissue sections resulted in a four-fold increase in the total number of peaks detected. To prove this principle, we used 0.1% SDS to generate peptide patterns from 2000 microdissected tumour and stromal cells from five different breast carcinoma tumours. The tumour and stroma specific peaks could be detected upon comparison of the peptide profiles. Identification of differentially expressed peaks by MALDI-TOF/TOF MS was performed on fractionated tryptic digests derived from a whole tissue slice. In conclusion, we describe a method that is suitable for direct peptide profiling on small amounts of microdissected cells obtained from breast cancer tissues.  相似文献   

13.
Reversed-phase liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) allows analysis of very complex peptide mixtures at great sensitivity, but it can be very time-consuming, typically using 60 min, or more, per sample analysis. We recently introduced the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation (~8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer for efficient analysis of peptide samples in proteomics research. The system performance of SPE-LC-MS/MS was evaluated in terms of sensitivity and efficiency for the analysis of tryptic peptide digests obtained from samples consisting of up to 12 standard proteins. The practical utility of the analytical setup was demonstrated by the analysis of <15 microg depleted human serum proteome by a combination of SDS-PAGE and SPE-LC-MS/MS. A total of 88 unique gene products spanning 3 orders of magnitude in serum protein concentration were identified using stringent database search criteria.  相似文献   

14.
Immobilized metal affinity chromatography (IMAC) based on Fe (3+) or Ga (3+) chelation is the most widely employed technique for the enrichment of phosphopeptides from biological samples prior to mass spectrometric analysis. An IMAC resin geared mainly toward phosphoprotein enrichment, Pro-Q Diamond, has been assessed for its utility in phosphopeptide isolation. Using both single phosphoprotein tryptic digests of beta-casein and ovalbumin and synthetic mixtures composed of tryptic digests of phosphorylated and nonphosphorylated protein standards, the selectivity and sensitivity of Pro-Q Diamond resin in an immobilized metal affinity-reversed phase microcolumn format were compared to an alternate titanium dioxide approach. The biphasic microcolumn method was found to be superior to metal oxide-based phosphopeptide capture in biological samples of increasing complexity. The lower limit of mass spectrometric detection for the immobilized metal affinity-reversed phase microcolumn approach was determined to be 10 pmol of beta-casein monophosphorylated peptide in 20 muL of a solution of human serum protein digest (from 200 mug total serum protein after digestion and desalting).  相似文献   

15.
The Virtual Expert Mass Spectrometrist (VEMS) program package was developed for flexible, automated, and manual de novo tandem mass spectrometry (MS/MS) protein sequencing, and includes accessory programs for matrix-assisted laser desorption/ionization-mass spectrometry (MS) interpretation, and generation of protein and peptide databases. VEMS V2.0 has been developed into a fast tool for combining database-independent and -dependent protein assignments in an extended analysis of MS/MS-peptide data. MS or MS/MS data can be directly recalibrated after the first search by fitting the data to the best search result using polynomial equations. The score function is an improvement of known scoring algorithms and can be adapted for any MS instrument type. In addition, VEMS offers a novel statistical model for evaluating the significance of the protein assignment. The novel features are illustrated by the analysis of the fragmentation spectra obtained by liquid chromatrography-MS/MS analysis of peptides from an anionic peroxidase enriched protein fraction from potato root tissue. The extended analysis mode resulted in the additional assignment of spectra for nine modified tryptic peptides and nine miscleaved peptides, in addition to the 45 spectra from regular tryptic peptides. Of the nine modified peptides, three were glycosylated.  相似文献   

16.
Shotgun proteome analysis platforms based on multidimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS) provide a powerful means to discover biomarker candidates in tissue specimens. Analysis platforms must balance sensitivity for peptide detection, reproducibility of detected peptide inventories and analytical throughput for protein amounts commonly present in tissue biospecimens (< 100 microg), such that platform stability is sufficient to detect modest changes in complex proteomes. We compared shotgun proteomics platforms by analyzing tryptic digests of whole cell and tissue proteomes using strong cation exchange (SCX) and isoelectric focusing (IEF) separations of peptides prior to LC-MS/MS analysis on a LTQ-Orbitrap hybrid instrument. IEF separations provided superior reproducibility and resolution for peptide fractionation from samples corresponding to both large (100 microg) and small (10 microg) protein inputs. SCX generated more peptide and protein identifications than did IEF with small (10 microg) samples, whereas the two platforms yielded similar numbers of identifications with large (100 microg) samples. In nine replicate analyses of tryptic peptides from 50 microg colon adenocarcinoma protein, overlap in protein detection by the two platforms was 77% of all proteins detected by both methods combined. IEF more quickly approached maximal detection, with 90% of IEF-detectable medium abundance proteins (those detected with a total of 3-4 peptides) detected within three replicate analyses. In contrast, the SCX platform required six replicates to detect 90% of SCX-detectable medium abundance proteins. High reproducibility and efficient resolution of IEF peptide separations make the IEF platform superior to the SCX platform for biomarker discovery via shotgun proteomic analyses of tissue specimens.  相似文献   

17.
Several approaches were explored for obtaining high sequence coverage in protein modification studies performed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Human serum albumin (HSA, 66.5kDa) was used as a model protein for this work. Experimental factors considered in this study included the type of matrix used for MALDI-TOF MS, the protein digestion method, and the use of fractionation for peptide digests prior to MALDI-TOF MS analysis. A mixture of alpha-cyano-4-hydroxycinnamic acid and 2,5-dihydroxybenzoic acid was employed as the final matrix for HSA. When used with a tryptic digest, this gave unique information on only half of the peptides in the primary structure of HSA. However, the combined use of three enzyme digests based on trypsin, endoproteinase Lys-C, and endoproteinase Glu-C increased this sequence coverage to 72.8%. The use of a ZipTip column to fractionate peptides in these digests prior to analysis increased the sequence coverage to 97.4%. These conditions made it possible to examine unique peptides from nearly all of the structure of HSA and to identify specific modifications to this protein (e.g., glycation sites). For instance, Lys199 was confirmed as a glycation site on normal HSA, whereas Lys536 and Lys389 were identified as additional modification sites on minimally glycated HSA.  相似文献   

18.
Selective and efficient preconcentration is indispensable for low concentration of phosphopeptides in phosphorylated protein‐related samples prior to MS‐based analysis. Herein, an on‐chip system coupled magnetic SPE with MALDI‐TOF MS was designed. A metal oxide affinity chromatography material, indium oxide, was coated on the surface of Fe3O4 magnetic nanoparticles to prepare the adsorbent, spatially confined with an applied magnetic field. The adsorbent exhibited high selectivity for phosphopeptides in tryptic digests of the mixture of β‐casein and BSA (1:1000) and the mixture of β‐casein, BSA, and ovalbumin (1:100:100). Thanking to the enrichment ability and specificity for phosphopeptides with the adsorbent, the on‐chip magnetic SPE‐MALDI‐TOF MS approach showed high sensitivity with a low detection limit of 4 fmol. In addition, the developed approach was used to analyze phosphopetides in non‐fat milk digests and human serum successfully.  相似文献   

19.
Recombinant porcine (rpST) and bovine somatotropins (rbST) synthesized in Escherichia coli contain the amino acid, epsilon-N-acetyllysine. This amino acid was initially discovered in place of the normal lysine144 in a modified reversed-phase HPLC (RP-HPLC) species of rpST. Mass spectrometry and amino acid sequencing of a tryptic peptide isolated from this RP-HPLC purified protein were used to identify this altered residue as epsilon-N-acetyllysine. Ion-exchange chromatography was utilized to prepare low isoelectric point (pI) forms of rpST and rbST, which are enriched in epsilon-N-acetyllysine. Electrospray mass spectrometry demonstrated that the majority of the protein in these low pI fractions contained species 42 Da larger than normal. Immobilized pH gradient electrophoresis (IPG) of the ion-exchange purified low pI proteins was used to isolate several monoacetylated species of rpST and rbST. The location of the acetylated lysine in each IPG-purified protein was determined by tryptic peptide mapping and amino acid sequencing of the altered tryptic peptides. Amino acid analyses of enzymatic digests of rpST and rbST were also used to confirm the presence of epsilon-N-acetyllysine in these recombinant proteins. These data demonstrate that a significant portion of rpST and rbST produced in E. coli contain this unusual amino acid.  相似文献   

20.
Clean silicon and gold-patterned silicon platforms were modified with methoxy-polyethylene glycol (M-PEG silane) via a self-assembly technique, which significantly improved their plasma protein resistance capability and cell patterning selectivity. Fibrinogen and IgG were used as model plasma proteins to study the efficacy of PEG layers in resisting protein adsorption. Selective cell patterning on the gold regions of a gold-patterned silicon substrate and tissue compatibility were studied with macrophage and fibroblast cells. The research also revealed how the presence of gold electrodes on a silicon substrate would influence the cell patterning selectivity. Our experimental results showed that the PEG-modified silicon surfaces had a high resistivity to protein and cell attachment and that the PEG-modified gold-patterned silicon surfaces nearly completely eliminated the protein adsorption and cell attachment on silicon. This study provides a new approach to developing biocompatible surfaces for silicon-based BioMEMS devices, particularly for biosensors where a metal-insulator format must be enforced.  相似文献   