首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mediated biosensors consisting of an oxidase and peroxidase (POx) have attracted increasing attention because of their wider applicability. This work presents a novel approach to fabricate nanobiocomposite bienzymatic biosensor based on functionalized multiwalled carbon nanotubes (MWNTs) with the aim of evaluating their ability as sensing elements in amperometric transducers. Electrochemical behavior of the bienzymatic nanobiocomposite biosensor is investigated by Faradaic impedance spectroscopy and cyclic voltammetry. The results indicate that glucose oxidase (GOD) and horseradish peroxidase (HRP) are strongly adsorbed on the surface of the thionin (TH) functionalized MWNTs and demonstrate a facile electron transfer between immobilized GOD/HRP and the electrode via the functionalized MWNTs in a Nafion film. The functionalized carbon nanotubes act as molecular wires to allow efficient electron transfer between the underlying electrode and the redox centres of enzymes through TH. Linear ranges for these electrodes are from 10 nM to 10 mM for glucose and 17 nM to 56 mM for hydrogen peroxide with the detection limit of 3 and 6 nM, respectively. A remarkable feature of the bienzyme electrode is the possibility to determine glucose and hydrogen peroxide at a very low applied potential where the noise level and interferences from other electroactive compounds are minimal. Performance of the biosensor is evaluated with respect to response time, detection limit, selectivity, temperature and pH as well as operating and storage stability.  相似文献   

2.
Multi-wall carbon nanotubes (MWNTs) functionalized with amino groups were prepared via silane treatment using 3-aminopropyltrimethoxysilane (APS) as a silane-coupling agent. The resultant amino terminated MWNTs (AMWNTs) were applied to construct glucose biosensors with IO(4)(-)-oxidized glucose oxidase (IO(4)(-)-oxidized GOx) through the layer-by-layer (LBL) covalent self-assembly method without any cross-linker. Scanning electron microscopy (SEM) indicated that the assembled AMWNTs were almost in a form of small bundles or single nanotubes, and the surface density increased uniformly with the number of GOx/AMWNTs bilayers. From the analysis of voltammetric signals, a linear increment of the coverage of GOx per bilayer was estimated. The resulting biosensor showed excellent catalytic activity towards the electroreduction of dissolved oxygen at low overvoltage, based on which glucose concentration was monitored conveniently. The enzyme electrode exhibited good electrocatalytic response towards the glucose and that response increased with the number of GOx/AMWNTs bilayers, suggesting that the analytical performance such as sensitivity and detection limit of the glucose biosensors could be tuned to the desired level by adjusting the number of deposited GOx/AMWNTs bilayers. The biosensor constructed with four bilayers of GOx/AMWNTs showed high sensitivity of 7.46muAmM(-1)cm(-2) and the detection limit of 8.0muM, with a fast response less than 10s. Because of relative low applied potential, the interference from other electro-oxidizable compounds was minimized, which improved the selectivity of the biosensors. Furthermore, the obtained enzyme electrodes also showed remarkable stability due to the covalent interaction between the GOx and AMWNTs.  相似文献   

3.
In this paper, a novel amperometric glucose biosensor was constructed by alternative self-assembly of positively charged poly(diallydimethylammonium chloride) (PDDA) and negatively charged glucose oxidase (GOx) onto a 3D Nafion network via electrostatic adsorption. The amount of Nafion in the electrode and the number of the (PDDA/GOx)n multilayers were optimized to develop a sensitive and selective glucose biosensor. Under optimal conditions, the glucose biosensor with (PDDA/GOx)5 multilayers exhibited remarkable electrocatalytic activity, capable of detecting glucose with enhanced sensitivity of 9.55 μA/mM cm2 and a commendably low detection limit of 20 μM (S/N = 3). A linear response range of 0.05–7 mM (a linear correlation coefficient of 0.9984, n = 20) was achieved. In addition, the glucose biosensor demonstrated superior selectivity towards glucose over some interferents, such as ascorbic acid (AA) and uric acid (UA), at an optimized detection potential of 0.6 V versus Ag/AgCl reference.  相似文献   

4.
A nanobiocomposite film consisted of polypyrrole (PPy), functionalized multiwalled carbon nanotubes (cMWNTs), and glucose oxidase (GOx) were electrochemically synthesized by electrooxidation of 0.1M pyrrole in aqueous solution containing appropriate amounts of cMWNTs and GOx. Potentiostatic growth profiles indicate that the anionic cMWNTs is incorporated within the growing PPy-cMWNTs nanocomposite for maintaining its electrical neutrality. The morphology of the PPy-cMWNTs nanocomposite was characterized by scanning electron microscopy (SEM). The PPy-cMWNTs nanocomposite was deposited homogeneously onto glassy carbon electrode. The amperometric responses vary proportionately to the concentration of hydrogen peroxide at the PPy-cMWNTs nanocomposite modified electrode at an operating potential of 0.7V versus Ag/AgCl (3M). The results indicate that the electroanalytical PPy-cMWNTs-GOx nanobiocomposite film was highly sensitive and suitable for glucose biosensor based on GOx function. The GOx concentration within the PPy-cMWNTs-GOx nanobiocomposite and the film thickness are crucial for the performance of the glucose biosensor. The amperometric responses of the optimized PPy-cMWNTs-GOx glucose biosensor (1.5 mgmL(-1) GOx, 141 mCcm(-2) total charge) displayed a sensitivity of 95 nAmM(-1), a linear range up to 4mM, and a response time of about 8s.  相似文献   

5.
Electrodeposition was used for the co-deposition of glucose oxidase (GOx) enzymes and palladium nanoparticles onto a Nafion-solubilized carbon nanotube (CNT) film. The co-deposited Pd-GOx-Nafion CNT bioelectrode retains its biocatalytic activity and offers an efficient oxidation and reduction of the enzymatically liberated H2O2, allowing for fast and sensitive glucose quantification. The combination of Pd-GOx electrodeposition with Nafion-solubilized CNTs enhances the storage time and performance of the sensor. An extra Nafion coating was used to eliminate common interferents such as uric and ascorbic acids. The fabricated Pd-GOx-Nafion CNT glucose biosensor exhibits a linear response up to 12 mM glucose and a detection limit of 0.15 mM (S/N = 3).  相似文献   

6.
We constructed a fusion protein (GOx-R5) consisting of R5 (a polypeptide component of silaffin) and glucose oxidase (GOx) that was expressed in Pichia pastoris. Silaffin proteins are responsible for the formation of a silica-based cell matrix of diatoms, and synthetic variants of the R5 protein can perform silicification in vitro[1]. GOx secreted by P. pastoris was self-immobilized (biosilicification) in a pH 5 citric buffer using 0.1 M tetramethoxysilane as a silica source. This self-entrapment property of GOx-R5 was used to immobilize GOx on a graphite rod electrode. An electric cell designed as a biosensor was prepared to monitor the glucose concentrations. The electric cell consisted of an Ag/AgCl reference electrode, a platinum counter electrode, and a working electrode modified with poly(neutral red) (PNR)/GOx/Nafion. Glucose oxidase was immobilized by fused protein on poly(neutral red) and covered by Nafion to protect diffusion to the solution. The morphology of the resulting composite PNR/GOx/Nafion material was analyzed by scanning electron microscopy (SEM). This amperometric transducer was characterized electrochemically using cyclic voltammetry and amperometry in the presence of glucose. An image produced by scanning electron microscopy supported the formation of a PNR/GOx complex and the current was increased to 1.58 μA cm−1 by adding 1 mM glucose at an applied potential of −0.5 V. The current was detected by way of PNR-reduced hydrogen peroxide, a product of the glucose oxidation by GOx. The detection limit was 0.67 mM (S/N = 3). The biosensor containing the graphite rod/PNR/GOx/Nafion detected glucose at various concentrations in mixed samples, which contained interfering molecules. In this study, we report the first expression of R5 fused to glucose oxidase in eukaryotic cells and demonstrate an application of self-entrapped GOx to a glucose biosensor.  相似文献   

7.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

8.
We report for the first time the development of a sensitive and selective glucose biosensor based on the self-assembling of multiwall carbon nanotubes (MWCNTs) dispersed in polyhistidine (Polyhis) and glucose oxidase (GOx) on glassy carbon electrodes (GCE). The supramolecular architecture was characterized by SEM, FT-IR and electrochemical techniques. The optimum multistructure was obtained with five (MWCNT-Polyhis/GOx) bilayers and one layer of Nafion as anti-interferent barrier. The sensitivity at 0.700V was (1.94±0.03) mAM(-1) (r=0.9991), with a linear range between 0.25 and 5.00mM, a detection limit of 2.2μM and a quantification limit of 6.7μM with minimum interference from lactose (1.5%), maltose (5.7%), galactose (1.2%), ascorbic acid (1.0%), and uric acid (3.3%). The biocatalytic layer demonstrated to be highly reproducible since the R.S.D. for 10 successive amperometric calibrations using the same surface was 3.6%. The sensitivity of the biosensor after 15 day storage at 4°C remained at 90% of its original value. The combination of the excellent dispersing properties and polycationic nature of polyhistidine, the stability of the MWCNT-Polyhis dispersion, the electrocatalytic properties of MWCNTs, the biocatalytic specificity of GOx, and the permselective properties of Nafion have allowed building up a sensitive, selective, robust, reproducible and stable glucose amperometric biosensor for the quantification of glucose in milk samples.  相似文献   

9.
Gu H  Yu Y  Liu X  Ni B  Zhou T  Shi G 《Biosensors & bioelectronics》2012,32(1):118-126
In this work, a novel amperometric biosensor for hydrogen peroxide was fabricated through the layer-by-layer (LBL) self-assembling of amine-terminated ionic liquid (IL-NH(2)), and sulfonic acid (SO(3)(-)) functionalized graphene by covalent bonding. The modification of the two functionalities introduced positive and negative charge onto the surface of graphene respectively, thus facilitating the formation of a multilayer film denoted with {IL-RGO/S-RGO}(n) through electrostatic interaction and further immobilization of glucose oxidase (GOx). The resulting {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor displayed an excellent response to glucose at a potential of -200 mV. Combined with on-line microdialysis system, the glucose biosensor in the on-line system showed good linear range from 10 μM to 500 μM with the detection limit of 3.33 μM (S/N=3). Consequently, the basal level of glucose in the striatum of anesthetic rats was calculated to be 0.376 ± 0.028 mM (mean ± s.d., n=3). The {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor was further applied for in vivo sensing of the glucose level in the striatum when rats received intraperitoneal (i.p.) injection of 30 μL insulin, which resulted in an obvious decrease in the extracellular concentration of glucose within 30 min. The method was proved to be sensitive and reproducible, which enabled its promising application in physiology and pathology.  相似文献   

10.
Zou Y  Sun LX  Xu F 《Biosensors & bioelectronics》2007,22(11):2669-2674
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl(3)-K(3)[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H(2)O(2) sensitivity greatly. A linear range from 8 x1 0(-8) to 1 x 10(-5)M and a high sensitivity 508.1 8 microA microM cm(2) for H(2)O(2) detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nafion and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species.  相似文献   

11.
Platinum nanowires (PtNWs) prepared by electrodeposition method with the help of porous anodic aluminum oxide (AAO) templates have been solubilized in chitosan (CHIT) together with carbon nantubes (CNTs) to form a PtNW-CNT-CHIT organic-inorganic system. The resulting PtNW-CNT-CHIT material brings capabilities for utilizing synergic action of PtNWs and CNTs to facilitate electron-transfer process in electrochemical sensor design. The PtNW-CNT-CHIT film modified electrode offered a significant decrease in the overvoltage for the hydrogen peroxide and showed to be excellent amperometric sensors for hydrogen peroxide at -0.1 V over a wide range of concentrations, and the sensitivity is 260 microAmM-1cm-2. As an application example, by linking glucose oxidase (GOx), an amplified biosensor toward glucose was prepared. The glucose biosensor exhibits a selective determination of glucose at -0.1 V with a linear response range of 5 x 10(-6) to 1.5 x 10(-2)M with a correlation coefficient of 0.997, and response time <10s. The high sensitivity of the glucose biosensor is up to 30 microAmM-1cm-2 and the detection limit was 3 microM. The biosensor displays rapid response and expanded linear response range, and excellent repeatability and stability.  相似文献   

12.
A novel amperometric biosensor, based on electrodeposition of platinum nanoparticles onto multi-walled carbon nanotube (MWNTs) and immobilizing enzyme with chitosan-SiO(2) sol-gel, is presented in this article. MWNTs were cast on the glass carbon (GC) substrate directly. An extra Nafion coating was used to eliminate common interferents such as acetaminophen and ascorbic acids. The morphologies and electrochemical performance of the modified electrodes have been investigated by scanning electron microscopy (SEM) and amperometric methods, respectively. The synergistic action of Pt and MWNTs and the biocompatibility of chitosan-SiO(2) sol-gel made the biosensor have excellent electrocatalytic activity and high stability. The resulting biosensor exhibits good response performance to glucose with a wide linear range from 1 microM to 23 mM and a low detection limit 1 microM. The biosensor also shows a short response time (within 5s), and a high sensitivity (58.9 microAm M(-1)cm(-2)). In addition, effects of pH value, applied potential, rotating rate, electrode construction and electroactive interferents on the amperometric response of the sensor were investigated and discussed in detail.  相似文献   

13.
Zhao H  Ju H 《Analytical biochemistry》2006,350(1):138-144
A bilayer of the polyelectrolytes poly(dimethyldiallylammonium chloride) (PDDA) and poly(sodium 4-styrenesulfonate) (PSS) was formed on a 3-mercapto-1-propanesulfonic-acid-modified Au electrode. Subsequently, multiwall carbon nanotubes (MWCNTs) wrapped by positively charged PDDA were assembled layer-by-layer with negatively charged glucose oxidase (GOx) onto the PSS-terminated bilayer. Electrochemical impedance spectroscopy and atomic force microscopy were adopted to monitor the regular growth of the PDDA-MWCNTs/GOx bilayers. Using GOx as a model enzyme, the assembled multilayer membranes showed some striking features such as the adsorbed form of GOx on individual MWCNT, uniformity, good stability, and electrocatalytic activity toward oxygen reduction. Based on the consumption of dissolved oxygen during the oxidation process of glucose catalyzed by the immobilized GOx, a sensitive amperometric biosensor was developed for the detection of glucose up to 5.0 mM with a detection limit of 58 microM. The sensitivity increased with increasing sensing layers up to five bilayers. Ascorbic acid and uric acid did not cause any interference due to the use of a low operating potential. The present method showed high reproducibility for the fabrication of carbon-nanotubes-based amperometric biosensors.  相似文献   

14.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a copper dispersed sol-gel derived ceramic-graphite composite. The copper in the biocomposite offers excellent electrocatalytic activity towards the reduction (at -0.2 V) as well as oxidation (at +0.45 V) of hydrogen peroxide liberated in the enzymatic reaction enabling sensitive and selective determination of glucose. A linear response to glucose in the concentration range between 2.7 x 10(-5) to 4.0 x 10(-3) M with a correlation coefficient of 0.9987 and 4.0 x 10(-5) to 5.6 x 10(-3) M with a correlation coefficient of 0.9989 were observed with the electrocatalytic reduction and oxidation, respectively. Ascorbic acid and uric acid did not interfere with the glucose measurement during catalytic reduction at -0.2 V, a Nafion membrane was used to eliminate these interferences during the electrocatalytic oxidation at +0.45 V. The combination of copper catalysis and the promising feature of sol-gel biocomposite favor the sensitive and selective determination of glucose with improved analytical capabilities.  相似文献   

15.
This paper describes highly stable enzyme precipitate coatings (EPCs) on electrospun polymer nanofibers and carbon nanotubes (CNTs), and their potential applications in the development of highly sensitive biosensors and high-powered biofuel cells. EPCs of glucose oxidase (GOx) were prepared by precipitating GOx molecules in the presence of ammonium sulfate, then cross-linking the precipitated GOx aggregates on covalently attached enzyme molecules on the surface of nanomaterials. EPCs-GOx not only improved enzyme loading, but also retained high enzyme stability. For example, EPC-GOx on CNTs showed a 50 times higher activity per unit weight of CNTs than the conventional approach of covalent attachment, and its initial activity was maintained with negligible loss for 200 days. EPC-GOx on CNTs was entrapped by Nafion to prepare enzyme electrodes for glucose sensors and biofuel cells. The EPC-GOx electrode showed a higher sensitivity and a lower detection limit than an electrode prepared with covalently attached GOx (CA-GOx). The CA-GOx electrode showed an 80% drop in sensitivity after thermal treatment at 50°C for 4 h, while the EPC-GOx electrode maintained its high sensitivity with negligible decrease under the same conditions. The use of EPC-GOx as the anode of a biofuel cell improved the power density, which was also stable even after thermal treatment of the enzyme anode at 50°C. The excellent stability of the EPC-GOx electrode together with its high current output create new potential for the practical applications of enzyme-based glucose sensors and biofuel cells.  相似文献   

16.
We report a simple electrochemical approach for the immobilization of glucose oxidase (GOx) on reduced graphene oxide (RGO). The immobilization of GOx was achieved in a single step without any cross linking agents or modifiers. A simple solution phase approach was used to prepare exfoliated graphene oxide (GO), followed by electrochemical reduction to get RGO-GOx biocomposite. The direct electrochemistry of GOx was revealed at the RGO-GOx modified glassy carbon electrode (GCE). The electrocatalytic and electroanalytical applications of the proposed film were studied by cyclic voltammetry (CV) and amperometry. It is notable that the glucose determination has been achieved in mediator-free conditions. RGO-GOx film showed very good stability, reproducibility and high selectivity. The developed biosensor exhibits excellent catalytic activity towards glucose over a wide linear range of 0.1-27mM with a sensitivity of 1.85μAmM(-1)cm(-2). The facile and easy electrochemical approach used for the preparation of RGO-GOx may open up new horizons in the production of cost-effective biosensors and biofuel cells.  相似文献   

17.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

18.
A method for optical imaging of the activity of glucose oxidase (GOx) using a fluorescent europium(III) tetracycline probe for hydrogen peroxide is presented. A decay time in the microsecond range and the large Stokes shift of 210 nm of the probe facilitate intensity-based, time-resolved, and decay-time-based imaging of glucose oxidase. Four methods for imaging the activity of GOx were compared, and rapid lifetime determination imaging was found to be the best in giving a linear range from 0.32 to 2.7 m Unit/mL. The detection limit is 0.32 m Unit/mL (1.7 ng mL(-1)) which is similar to that of the time-resolved (gated) imaging using a microtiterplate reader. Fluorescent imaging of the activity of GOx is considered to be a useful tool for GOx-based immunoassays with potential for high-throughput screening, immobilization studies, and biosensor array technologies.  相似文献   

19.
In this work, the excellent catalytic activity of highly ordered mesoporous carbons (OMCs) to the electrooxidation of nicotinamide adenine dinucleotide (NADH) and hydrogen peroxide (H(2)O(2)) was described for the construction of electrochemical alcohol dehydrogenase (ADH) and glucose oxidase (GOD)-based biosensors. The high density of edge-plane-like defective sites and high specific surface area of OMCs could be responsible for the electrocatalytic behavior at OMCs modified glassy carbon electrode (OMCs/GE), which induced a substantial decrease in the overpotential of NADH and H(2)O(2) oxidation reaction compared to carbon nanotubes modified glassy carbon electrode (CNTs/GE). Such ability of OMCs permits effective low-potential amperometric biosensing of ethanol and glucose, respectively, at Nafion/ADH-OMCs/GE and Nafion/GOD-OMCs/GE. Especially, as an amperometric glucose biosensor, Nafion/GOD-OMCs/GE showed large determination range (500-15,000mumoll(-1)), high sensitivity (0.053nAmumol(-1)), fast (9+/-1s) and stable response (amperometric response retained 90% of the initial activity after 10h stirring of 2mmoll(-1) glucose solution) to glucose as well as the effective discrimination to the possible interferences, which may make it to readily satisfy the need for the routine clinical diagnosis of diabetes. By comparing the electrochemical performance of OMCs with that of CNTs as electrode material for the construction of ADH- and GOD-biosensors in this work, we reveal that OMCs could be a favorable and promising carbon electrode material for constructing other electrochemical dehydrogenase- and oxidase-based biosensors, which may have wide potential applications in biocatalysis, bioelectronics and biofuel cells.  相似文献   

20.
We report on an amperometric biosensor that is based on a nanocomposite of carbon nanotubes (CNT), a nano-thin plasma-polymerized film (PPF), and glucose oxidase (GOx) as an enzyme model. A mixture of the GOx and a CNT film is sandwiched with 10-nm-thick acetonitrile PPFs. Under PPF layer was deposited onto a sputtered gold electrode. To facilitate the electrochemical communication between the CNT layer and GOx, CNT was treated with nitrogen or oxygen plasma. The resulting device showed that the oxidizing current response due to enzymatic reaction was 4-16-fold larger than that with only CNT or PPF, showing that the PPF and/or plasma process is an enzyme-friendly platform for designing electrochemical communication from the reaction center of GOx to the electrode via CNTs. The optimized glucose biosensor showed high sensitivity (sensitivity of 42 microA mM(-1)cm(-2), correlation coefficient of 0.992, linear response range of 0.025-2.2 mM, and a detection limit of 6 microM at signal/noise ratio of 3, +0.8 V versus Ag/AgCl), high selectivity (almost no interference by 0.5 mM ascorbic acid) for glucose quantification, and rapid response (<4 s to reach 95% of maximum response). Additionally, the devices showed a small and stable background current (0.35+/-0.013 microA) compared with the glucose response (ca. 10 microA at 10mM glucose) and suitable reproducibility from sample-to-sample (<3%, n=4).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号