首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel multi-channel 2 x 5 model of piezoelectric quartz micro-array immunosensor has been developed for quantitative detection of human chorionic gonadotropin (hCG) in serum or urine samples. Every crystal unit of the fabricated piezoelectric hCG micro-array immunosensor can oscillate independently without interfering each other. A 2 x 5 model of micro-array immunosensor as compared with a one-channel immunosensor can provide eight times higher detection speeds for hCG assay. The anti-hCG antibody is deposited on the gold electrode's surface of 10 MHz quartz AT-cut crystal by self-assembled technique using sulfosuccinimidyl 6-[3'-(2-pyridyldithio) propionamido] hexanoate (Sulfo-LC-SPDP), and serves as an antibody recognizing layer. The highly ordered self-assembled monolayers (SAM) ensure well-controlled surface structure and offer many advantages to the performance of the sensor. Compared with conventional antibody immobilization methods, the amount and the reaction activity of antibody monolayer coated by the SAM binding are bigger than those by the SPA method, and less non-specific binding caused by other analytes in sample is found. Under the optimized experimental conditions, the results showed that micro-array immunosensor quantitatively detected serum or urine hCG in the range of 2.5-500 mIU/ml with high precision (CV<5%); other hormones in human serum and urine did not interfere with the determination markedly. Serum and urine samples of 60 patients were detected by the micro-array immunosensor, and the results agreed well with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.92. After regeneration with urea solution the coated immunosensor can be reused five times without appreciable loss of activity.  相似文献   

2.
Su X  Chew FT  Li SF 《Biosensors & bioelectronics》2000,15(11-12):629-639
This work presents a piezoelectric (Pz) quartz crystal based label-free quantification of total IgE and allergen-specific IgE in human sera for allergy testing. An evaluation of the different brands of crystals was first initiated with respect to variability in mass sensitivity, frequency measurement reliability and stability, and surface roughness. Thereafter, for total IgE quantification. a direct assay format was adopted. By means of thioctic acid (TA) and coupling reagents, anti-human IgE antibodies were immobilized on AT-cut Pz crystals (10 MHz). The modified crystals could detect serum IgE directly corresponding to a downward frequency shift. The results showed that silver-coated crystals as compared with their gold-coated counterparts provided approximately 1.5 times higher mass detection sensitivity for total IgE in the range of 5-300 IU/ml with a linear regression line, y = 1.8957 x + 1.5603, R2 = 0.995. For the detection of allergen-specific IgE, a sandwiched assay format was used. As the allergen-modified sensor surface captured various classes of associated antibodies (IgE, IgG, etc) and interfering serum proteins as well, the initial frequency shift downwards caused by sera sample incubation would not be proportional to specific IgE levels. Thus, following sample incubation, a second incubation step with secondary anti-human IgE was added to recognize IgE from other bound substances. The frequency shift after secondary antibody binding reflected the amount of allergen-specific IgE proportionally. Compared with 10 MHz crystals, the 20 MHz counterparts provided approximately four times higher mass detection sensitivity for allergen specific IgE in the range of 0.15-17.5 IU/ml with a linear regression line, y = 50.525 x + 107.777, R2 = 0.954. Total IgE and allergen specific IgE assay results of real patients' sera using the Pz sensors agreed well with those obtained by commercially available test kits with correlation coefficient 0.96-0.98. The possibility of regenerating the quartz crystals for further re-use was also dealt with.  相似文献   

3.
A direct human ferritin immunosensor was developed using anti-human ferritin monoclonal antibodies (MAbs) immobilized on the gold surface of a self-assembled surface plasmon resonance (SPR) apparatus. A kind of self-assembled monolayer (SAM) prepared by cystamine-glutaraldehyde method was applied to immobilize the MAbs. The reusability of the sensor chip adopting the SAM was found to be better than the other immobilization methods including adsorption, protein A, concanavalin A method. Ten cycles of measurements could be performed on the same chip regenerated with a 0.1M HCl solution. A linear relationship existed between the angle shifts (millidegrees) and the log values of ferritin concentrations in the range from 0.2 to 200 ng/ml in buffer and human serum. When used for 15 days, the angle shifts were all >95% of those on the response at the first day. A 10 M NaOH solution was used for clearing nonspecific binding in human serum. Correlation coefficient was 0.991 between this SPR method and chemiluminescent immunoassay for determination of ferritin in clinical human serum samples. The SPR sensor offers advantages of simplicity of immobilization, high sensitivity, high specificity, low sample requirement, high reusability, no label and no pretreatment etc.  相似文献   

4.
A simple, highly sensitive immunosensor for the direct determination of immunoglobulin (Ig) in canine serum based on a piezoelectric crystal accommodated in a flow-cell was developed and optimized. The new biosensor is also useful for discriminating between Ig subclasses present in canine serum by using specific monoclonal antibodies binding to the coated crystal. Various canine monoclonal anti-IgG were deposited onto the surface of the gold-coated crystal resonator using the self-assembly technique to form a receptor layer. The highly ordered self-assembled monolayers thus obtained provide a well-controlled surface structure and many advantages as regards sensing performance. The results obtained with the proposed immunosensor were compared with those provided by a protein A-based orientation-controlled immobilization method for the same monoclonal antibodies and also with direct physical adsorption of the antibodies. The crystal was accommodated in a flow-cell that was inserted into a buffer flowing stream in order to make resonant frequency measurements.  相似文献   

5.
Allergen microarrays are under development for a component‐resolved diagnosis of Type I (IgE‐mediated) allergies. Here we report an improved microarray coupled to microfluidics for the detection of allergen specific immunoglobulin E (IgE). The signal intensity for IgE detection in serum has been improved by using glass slides coated with a novel poly[DMA‐co‐NAS] brush copolymer which is able to immobilize allergens in their native conformation and by carrying out the incubation step in dynamic conditions. The assay, fully automated, was performed in a microcell, using a software‐controlled fluidic processor, to bring assay reagents on the surface of the array. Microfluidics turns the binding between serum immunoglobulins and immobilized allergens from a diffusion‐limited to a kinetic‐limited process by ensuring an efficient mixing of serum samples on the surface of the microarray. As a result of this, the binding of high affinity IgE antibodies is enhanced whereas that of low affinity IgG antibodies, which are present at higher concentration, is impaired paving the way to more accurate and sensitive results.  相似文献   

6.
A direct piezoelectric flow injection analysis immunoassay for the detection of African Swine Fever virus and antibodies is presented. The peptide-specific monoclonal antibody 18BG3 and the virus protein 73 were used for detection with a quartz crystal microbalance. Accumulation of the analyte on the surface of this mass-sensitive biosensor resulted in a shift of the resonant frequency. Highly selective receptor layers were applied on the sensing electrode of the quartz crystal for detection of the complementary analyte. Different immobilization methods proved to be appropriate for coating of the monoclonal antibody 18BG3. A quartz crystal covalently coated with the antibody 18BG3 detected virus protein VP73 samples more than 20 times and was stable for more than 30 days. The coating of virus protein was performed by physisorption. A sensor with a virus protein receptor layer detected antibody 18BG3 samples 10 times within one day. The sensor device was able to perform one measurement cycle including blocking and regeneration within 30 min. With the help of a suitable carrier liquid, measurements with serum samples were performed. The calibration curves for measurements in buffer and in serum could be determined and the detection limits for virus protein detection were 0.31 and 1 μg/ml, and for antibody detection 0.1 and 0.2 μg/ml, respectively.  相似文献   

7.
A Fischer carbene complex was grafted onto self-assembled monolayers (SAMs) on gold or glass by a copper-free "click" reaction. Pendant lysine residues of protein A obtained from Staphylococcus aureus rapidly reacted with the electrophilic metal complex on SAM effecting a covalent attachment of protein A with the surface. The protein A coated surface further led to bioaffinity immobilization of rabbit IgG in an oriented manner, a feature that also permits its purification from rabbit serum. Rabbit IgG could be removed from protein A coated surface by pH adjustment. The regenerated protein A surface was reused three times without loss of activity.  相似文献   

8.
Soluble IgE receptors are potential in vivo modulators of IgE-mediated immune responses and are thus important for our basic understanding of allergic responses. We here characterize a novel soluble version of the IgE-binding alpha-chain of Fc-epsilon-RI (sFcεRI), the high affinity receptor for IgE. sFcεRI immunoprecipitates as a protein of ~40 kDa and contains an intact IgE-binding site. In human serum, sFcεRI is found as a soluble free IgE receptor as well as a complex with IgE. Using a newly established ELISA, we show that serum sFcεRI levels correlate with serum IgE in patients with elevated IgE. We also show that serum of individuals with normal IgE levels can be found to contain high levels of sFcεRI. After IgE-antigen-mediated crosslinking of surface FcεRI, we detect sFcεRI in the exosome-depleted, soluble fraction of cell culture supernatants. We further show that sFcεRI can block binding of IgE to FcεRI expressed at the cell surface. In summary, we here describe the alpha-chain of FcεRI as a circulating soluble IgE receptor isoform in human serum.  相似文献   

9.
Immunoglobulin E (IgE)-mediated type I allergies affect over 25% of the world's population; they are among the most common diseases in developed countries. Therefore, simple and rapid in vivo and in vitro methods for diagnosing allergies are becoming increasingly important. In this paper, we demonstrate the feasibility of using sulforhodamine B, a fluorescent dye, entrapped inside immunoliposomes, the outer surfaces of which were sensitized with IgE, as a signal amplifier for the development of a simple, rapid, and inexpensive colorimetric affinity chromatographic immunoassay for the detection of total IgE in serum. This assay operates based on competition between standards (or human serum samples) containing IgE and IgE-sensitized immunoliposomes for the limited number of antigen binding sites of immobilized anti-IgE antibodies at the antigen capture (AC) zone on the nitrocellulose membranes. The color density of the AC zone is indirectly proportional to the number of IgE units present in the test sample. The detection limit of this liposome-based immunoaffinity chromatographic assay was 0.37 ng in IgE-free serum solution (equivalent to 20 μL of a 18.5 ng mL−1 solution). A commercially available ELISA kit was used as a reference method to validate the proposed assay through the analysis of three human serum samples.  相似文献   

10.
The self-assembled layer of modified protein A was fabricated. In order to modify protein A, the surface group of protein A was substituted with thiol (-SH) functionality by using N-succinimidyl-3-(2-pyridyldithio)propionate (SPDP) and dithiothreitol (DTT). The formation of a self-assembled protein A layer on a Au substrate and its increased binding capacity to antibody were confirmed by surface plasmon resonance (SPR) spectroscopy. The surface structure of self-assembled protein A layer, and the binding status of anti-bovine serum albumin (anti-BSA) and BSA were determined by atomic force microscopy (AFM). Treatment on the self-assembled protein A layer with a detergent, such as Tween 20, increased the binding capacity of anti-BSA, because protein A aggregation was reduced significantly by the detergent; this was confirmed by SPR spectroscopy. The self-assembled layer of chemically modified protein A with enhanced binding capacity can be used for immunosensor fabrication.  相似文献   

11.
This paper describes direct binding of a small vancomycin to peptide ligands immobilized on a sensor chip using quartz crystal microbalance. In this study, the binding ligands were composed of three components: a molecular recognition element (peptide), a conformationally flexible and hydrophilic linker, and a long-chain alkanethiol. These peptide ligands were used to establish the well-packed, self-assembled monolayers on quartz chips and could be readily synthesized using conventional organic chemistry protocols. Results of quartz crystal microbalance measurements showed that vancomycin specifically associated with the d-Ala-d-Ala-containing peptide with an affinity of 3.2+/-0.3 microM and was, as expected, completely inactive to the self-assembled monolayer presenting l-Ala-l-Ala peptide. The dissociation constant obtained correlated well with values reported in literature and was further confirmed by surface plasmon resonance measurement (2.7+/-0.7 microM). The technique used in this study should be applicable to both peptidyl and nonpeptidyl ligands of greater complexity than that used here. This method is practical, it provides quantitative binding information, and complicated analysis is avoided.  相似文献   

12.
A surface modification procedure for the creation of self-assembled monolayers (SAMs) that can be used as a scaffold for double-stranded DNA (dsDNA) incorporation onto the gold surfaces is described. The SAMs of an azidohexane thiol derivative were prepared on the Au electrode and then used for the immobilization of dsDNA. The electrochemical characteristics of dsDNA onto the SAM-modified gold electrode were investigated by cyclic voltammetry and electrochemical impedance spectroscopy, and the surface concentration of dsDNA onto the SAMs surface was estimated. The interaction of dsDNA with the anticancer drug, taxol (paclitaxel), was also studied on the surface of DNA/SAM/Au electrode. The observed decrease in the guanine oxidation peak current was used to monitor the interaction of taxol with DNA. The resulting Langmuir isotherm for taxol binding to DNA at the modified electrode was used to evaluate the binding constant of taxol-DNA. The results obtained supported the groove binding interaction of taxol with DNA. The modified electrode was used as a sensitive sensor for quantification of taxol in human serum sample.  相似文献   

13.
Sensitive and rapid detection of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) was achieved with a newly developed evanescent wave all-fiber immunosensor (EWAI). A reusable functional sensing surface of the immunosensor is prepared by covalent binding of 2,4-D-bovine serum albumin (2,4-D-BSA) conjugate to a self-assembled alkanethiol monolayer formed onto the fiber optic probe through heterobifunctional reagent. The quantification of free 2,4-D in samples was based on indirect competitive immunoreaction principle. Under optimum conditions, calibration curve obtained for 2,4-D had detection limits of 0.07 microg L(-1), the 50% inhibition concentration (IC(50)) was 3.93+/-0.03 microg L(-1) and the quantitative detection range was 0.22-69.5 microg L(-1). The antibodies binding on the sensor surface could be removed simply by the flow of a pepsin solution (pH 1.9), facilitating reuse of the same probe. The regeneration of the sensor surface allowed the performance of more than 100 assay cycles without significant loss of reactivity. The antibody showed negligible cross-reactivity against a few compounds structurally similar to 2,4-D. The immunosensor developed was successfully applied to the monitoring of 2,4-D in spiked water samples without significant effect of the matrix. The proposed portable immunosensor is promising for real-time on-site analysis of small molecules of environmental interest.  相似文献   

14.
Humans can detect and differentiate the presence of different odours even at trace levels of these odorous compounds. The odour quantification of any particular samples is normally based on conventional panel decisions. Other analytical instruments could be used to detect trace levels of odorous molecules. This study presents the results of a biological sensor system subject to different odorants. The system consists of a sensor in which the isolated olfactory receptor proteins (ORPs) from bullfrogs (Rana spp.) were coated onto the surface of a piezoelectric (PZ) electrode, similar to the mechanism of human olfaction. The PZ crystal served as a signal transducer. The results indicate rapid (about 400 s), reversible, and longterm (up to 3 months) stable responses to different volatile compounds such as n-caproic acid, isoamyl acetate, n-decyl alcohol, beta-ionone, linalool, and ethyl caporate. The sensitivity of the sensor ranges from 10(-6)-10(-7) g, fully correlated with the olfactory threshold values of human noses. An array of six sensors consisting of five fractionated ORPs and one referenced phospholipid probe is able to respond to different odorants and form a typical fingerprint for each odorant.  相似文献   

15.
A batch-type antibody-immobilized quartz crystal microbalance (QCM) system for detecting chloramphenicol (CAP) was developed. To bind an anti-CAP antibody onto the gold electrode surface of piezoelectric crystals, self-assembled monolayers (SAMs) of different thiols or sulfides were formed by a chemisorption procedure. Then, the anti-CAP antibody was covalently linked to the pre-formed monolayers by an activation procedure using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride and N-hydroxysulfosuccinimide. The antibody-immobilized QCM chip thus prepared was installed in a well holder and was measured for sensor response. Compared with the bare QCM chip and the QCM chip only coated with 3-mercaptopropionic acid (MPA), the antibody-immobilized sensor showed greatly enhanced frequency shifts by 10-50-fold after CAP injection. In this case, CAP detection which was indicated by steady-state resonant frequency shift was accomplished within 10 min. When CAP solution was injected into the reaction cell in 50mM concentration, the frequency shifts obtained were, respectively, 530 and 505 Hz in case of thiosalicylic acid and MPA immobilization. Repeated use of the sensor chips up to eight times was possible after 1 min regeneration with 0.1M NaOH. This system demonstrated a potential application of thiol or sulfide mediated SAMs as the pre-coatings of a real-time detection on CAP in solution.  相似文献   

16.
Specific binding of the anticoagulants heparin and antithrombin III to the blood clotting cascade factor human thrombin was recorded as a function of time with a Love-wave biosensor array consisting of five sensor elements. Two of the sensor elements were used as references. Three sensor elements were coated with RNA or DNA aptamers for specific binding of human thrombin. The affinity between the aptamers and thrombin, measured using the biosensor, was within the same range as the value of K(D) measured by filter binding experiments. Consecutive binding of the thrombin inhibitors heparin, antithrombin III or the heparin-antithrombin III complex to the immobilized thrombin molecules, and binding of a ternary complex of heparin, anithrombin III, and thrombin to aptamers was evaluated. The experiments showed attenuation of binding to thrombin due to heparin-antithrombin III complex formation. Binding of heparin activated the formation of the inhibitory complex of antithrombin III with thrombin about 2.7-fold. Binding of the DNA aptamer to exosite II appeared to inhibit heparin binding to exosite I.  相似文献   

17.
To rapidly quantify total immunoglobulin E levels in human serum, we developed a novel quantum-dot-based immunochromatographic assay that employs digital recording of fluorescence. It can detect IgE levels of 5–1000 kU/L, with a coefficient of variation ranging from 2.0 to 9.5%. The assay can be processed in 10 min. The developed assay was tested on 95 serum samples. The correlation coefficient between the IgE values obtained by the proposed assay and those obtained by a commercial ELISA kit was 0.9884. Our assay thus shows promise as a new diagnostic tool for IgE detection.  相似文献   

18.
This study presents a novel auto-gain-control based quartz acoustic sensor technology capable of constant quartz crystal operation when cycled between ambient (22 degrees C) and cryogenic temperatures (-196 degrees C), afforded by direct exposure of crystals to bulk liquid nitrogen. The real-time frequency response profiles due to freeze-thaw cycling on crystals of differing surface finish and two model macromolecular surface coatings were studied in order to determine surface events such as water uptake. The quartz crystal surface finishes used were optically polished or lapped to one of two surface finishes. These were used as control native gold electrodes, and these surfaces were further coated with bovine serum albumin or the tri-block copolymer, poloxamer-188 as model macromolecular surface architectures. Crystals were snap frozen in liquid nitrogen and allowed to return to ambient temperature under controlled conditions. The processes of ice formation, thawing and evaporation were followed in real-time and comparisons were made between the test samples in order to assess the capability of this technique for sensing changes in surface characteristics such as the entrapment of water.  相似文献   

19.
A self-assembled 3D hydrogel-nanoparticle composite integrated surface plasmon resonance (SPR) sensor is reported here. The novel assembled substrate was developed by means of a surface mediated radical co-polymerization process to obtain a highly sensitive hydrogel-based thin film that possesses specific binding sites for target analytes. Initially, amino group modified gold nanoparticles (AuNPs) were covalently linked to acrylic acid monomer. Following this, N-isopropylacrylamide (NIPAAm) and AuNPs linked acrylic acid (AAc) monomers were randomly co-polymerized by the "grafting from" method in the presence of initiator and crosslinker onto the sensing surface. Surface characterization techniques were utilized to evaluate the thickness and composition of the hydrogel-nanoparticle film. The sensing platform was employed to study the binding kinetics and conformational changes of the ArsA ATPase as a consequence of binding trivalent arsenicals under a variety of conditions. ArsA, the catalytic subunit of the ArsAB arsenite (As(III)) translocating ATPase, is one of the five proteins encoded by the arsenical resistance (ars) operon of plasmid R773 in cells of Escherichia coli, that confers resistance to trivalent and pentavalent salts of the metalloid arsenic. SPR measurements indicate that the 3D hydrogel-nanoparticle coated sensors exhibited a higher sensitivity than that of the 2D AuNPs decorated sensors. Binding of As(III) to ArsA is greatly facilitated by the presence of magnesium ion and ATP.  相似文献   

20.
This work reports on a complementary use of surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D) technologies to study interactions between a peptide antigen and polyclonal antibodies, in an experimental format suitable for diagnostic assays of autoimmune diseases. In the chosen model, a synthetic peptide from the juxtamembrane region of IA-2 (a type 1 diabetes associated antigen) was immobilized by an optimized chemical protocol applicable to both BIACORE and QCM-D sensors. A thorough study of the peptide immobilization was performed to optimize the signal-to-noise ratio using mixed self-assembled monolayers (SAM) on a gold surface. Introduction of polyethylene glycol (EG6) chains into mixed SAM layers and addition of an anionic surfactant to the human serum reduced non-specific binding without modifying the viscoelasticity properties of the layer. Under our conditions, the antibody SPR detection limit was determined to be 0.2 nM in diluted human serum. This value is in agreement with the reported rank distribution of IA-2 antibodies in diabetic patient sera. Label-free and real-time technologies such as SPR and/or QCM-D could be precious tools in future diagnostic assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号