首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
3′-Azido-2′,3′-dideoxyuridine (AZDU, Azddu, CS-87) is a nucleoside analog of 3′-azido-3′-deoxythymidine (zidovudine, AZT) that has been shown to inhibit human immunodeficiency virus (HIV-1). AZDU is a potential candidate for treatment of pregnant mothers to prevent prenatal transmission of HIV/AIDS to their unborn children. A rapid and efficient high-performance liquid chromatography (HPLC) method for the determination of AZDU concentrations in rat maternal plasma, amniotic fluid, placental and fetal tissue samples has been developed and validated. Tissue samples were homogenized in distilled water, protein precipitated and extracted using a C-18 solid-phase extraction (SPE) method prior to analysis. Plasma and amniotic fluid samples were protein precipitated with 2 M perchloric acid prior to analysis. Baseline resolution was achieved using a 4.5% acetonitrile in 40 mM sodium acetate (pH 7) buffer mobile phase for amniotic fluid, placenta and fetus samples and with a 5.5% acetonitrile in buffer solution for plasma at flow-rates of 2.0 ml/min. The HPLC system consists of a Hypersil ODS column (150×4.6 mm) with a Nova-Pak C-18 guard column with detection at 263 nm. The method yields retention times of 6.2 and 12.2 min for AZDU and AZT in plasma and 8.3 and 17.6 min for AZDU and AZT in amniotic fluid, fetal and placental tissues. Limits of detection ranged from 0.01 to 0.075 μg/ml. Recoveries ranged from 81 to 96% for AZDU and from 82 to 96% for AZT in the different matrices. Intra-day (n=6) and inter-day (n=9) precision (% RSD) and accuracy (% Error) ranged from 1.48 to 6.25% and from 0.50 to 10.07%, respectively.  相似文献   

2.
3.
High-performance liquid chromatography with both absorbance and fluorescence detection has been applied to the determination of the potential anti-tumour agent combretastatin A-4 and its phosphate ester in murine and human plasma. The presence of different interfering peaks in the two species makes absorbance detection at 295 nm the method of choice for the mouse, and fluorescence detection (295 nm/390 nm) for human plasma. The calibration was linear over the range studied (0.01–50 μM for combretastatin A-4, 0.02–200 μM for combretastatin A-4 phosphate), with quantitation limits of 0.05 μM for both drugs in the mouse, and 0.05 μM and 0.0125 μM for the phosphate ester and free drug, respectively, in human plasma. The method should be useful for pharmacokinetic studies in the forthcoming Phase I clinical trial of combretastatin A-4 phosphate.  相似文献   

4.
5.
A high-performance liquid chromatographic (HPLC) technique was developed using commercially available derivatization reagents and commonly used reversed-phase HPLC column chemistry to analyze plasma samples for their carnitine ester content. The method proved to be sufficiently sensitive to determine changes in the carnitine ester profile in plasma resulting from metabolic disorders or metabolic insults. The method was tested using plasma samples obtained from pigs fed medium-chain triglycerides (MCT) of different chain lengths (four to seven carbons). The MCT feeding was associated with transient increases in plasma carnitine and carnitine esters, and feeding odd-chain MCT (tri-C5 or tri-C7) led to elevated levels of propionylcarnitine in plasma.  相似文献   

6.
A method for the separation of substituted indole derivatives has been developed by the use of ion suppression-reversed-phase high-performance liquid chromatography (IS-HPLC). Signal response, selectivity (alpha), retention times (tR), and capacity factors (k') were monitored by varying the mobile phase with respect to methanol composition and pH. Chromatographic parameters including tR, k', K (distribution coefficients), alpha, number of theoretical plates, height equivalent to theoretical plates, and column resolution were calculated and assessed in regard to the suitability of four stationary phases in the analysis of 20 substituted indole derivatives. This work has established the chromatographic foundation needed to analyze over 10 specific enzyme reactions involved in the microbial and plant metabolism of auxins. Quantitative studies on the stability of auxins were possible by employing IS chromatography (ISC). The application of the developed IS chromatographic technique was employed to detect indole-3-acetic acid derived from L-tryptophan in a fluorescent pseudomonad culture.  相似文献   

7.
A combined assay is described for cocaine and its major metabolites, benzoylecgonine and ecgonine methyl ester. The method uses electrochemical and ultraviolet detectors in series. A non-silica column is used with high-pH mobile phase. The three compounds are completely separated from other cocaine metabolites. The assay has been suitable for pharmacokinetic studies of cocaine disposition in animal studies.  相似文献   

8.
Rats fed with a fat-free or an olive oil-rich diet were employed to compare the response of two chromatographic techniques in the determination of rat liver triglyceride (TG) molecular species composition. Gas–liquid chromatography (GLC) on polarizable liquid phase and reversed-phase high-performance liquid chromatography (RP-HPLC) have been commonly employed for TG analysis, obtaining a similar number of chromatographic peaks when used for animal tissue TG determination. In the present study similar results were achieved with regard to most relevant chromatographic peaks, however, important differences were found in the content of minor TGs. Indeed, RP-HPLC permitted separation of long chain polyunsaturated fatty acids, which were not detected by GLC, while the latter technique reported a higher number of myristoyl-containing TG species. RP-HPLC analysis reported a greater number of TGs, with more similarity to a random composition, made up from the liver fatty acid composition. Therefore, it was concluded that utilization of both techniques would be helpful for liver TG analysis as the use of only one of them does not provide a complete profile of liver TGs. Nevertheless RP-HPLC seems to be more useful for this purpose since revealed a more extensive profile.  相似文献   

9.
Determination of cystamine by high-performance liquid chromatography   总被引:2,自引:0,他引:2  
A highly sensitive and specific assay method for cystamine using high-performance liquid chromatography has been developed. The method is based on postcolumn derivatization of cystamine with o-phthaladehyde in the presence of 2-mercaptoethanol and sodium hypochlorite. The separation of cystamine was achieved using a cation exchange column (ISC-05/S0504). The assay was linear over the concentration range of 2 to 200 pmol. For the application of this assay method to biological materials, the pretreatment with a cation exchange column (Dowex 50W X 8) was necessary to remove interfering o-phthaladehyde-reactive substances. Since cysteamine in biological materials was quantitatively converted to cystamine during these sampling procedures, this method was found to be suitable for assaying the cysteamine plus cystamine content in various organs and tissues. The cysteamine-cystamine content in various tissues of rat determined by the present assay method has been presented.  相似文献   

10.
11.
The polyamines putrescine, cadaverine, spermidine, and spermine and the corresponding mono-N-acetylpolyamines can be separated as their dimethylaminoazobenzenesulfonyl derivatives in a single analysis in less than 22 min. The method employs reversed-phase high-performance liquid chromatography (Spherisorb S5 ODS2 column) with an acetonitrile/acetate buffer gradient elution system and detection in the visible (436 nm) region. The detection limit for a single dimethylaminoazobenzenesulfonylpolyamine is less than 2 pmol.  相似文献   

12.
A reversed-phase high-performance liquid chromatographic method for the determination of α-tocopherol in plasma or erythrocytes with photodiode-array detection is described. Using this detector, information about the spectrum, absorption maxima and purity of the peak is obtained. Tocopherol was separated on a 5-μm Spherisorb ODS-2 column with methanol as element at a flow-rate of 1.0 ml/min. As little as 100 μl of plasma or 150 μl of erythrocytes can be used for accurate analysis with direct extraction without saponification. The speed, specificity, sensitivity and reproducibility of this technique make it particularly suitable for the routine determination of α-tocopherol in plasma or erythrocytes.  相似文献   

13.
Unsaturated triacylglycerols (TG) and choline (PC) and ethanolamine (PE) phosphatides of known structure were subjected to ozonization and reduction with triphenylphosphine to yield the corresponding lipid ester core aldehydes. Mono- and di-C9 aldehyde palmitoylglycerols were prepared from oleoyldipalmitoyl and oleoyllinoleoylpalmitoyl glycerols, respectively, while egg yolk PC and PE provided the mono-C5 and mono-C9 aldehydes of palmitoyl-and stearoyl glycerophospholipids. The aldehydes were isolated in the free form and as the dinitrophenylhydrazone (DNPH) derivatives by thin-layer chromatography (TLC). The intermediate ozonides, free aldehydes and hydrazones were identified by reversed phase high performance liquid chromatography (HPLC) with on-line negative ion thermospray and normal phase HPLC with on-line positive ion electrospray mass spectrometry (LC-MS). The synthetic aldehydes were used as carriers during isolation from natural sources and as reference compounds in quantitative analyses  相似文献   

14.
A high-performance liquid chromatographic (HPLC) method for the determination of L-carnitine in clamped and frozen rat livers is described. L-carnitine + acetyl-CoA in equilibrium with acetyl-L-carnitine + CoASH Using the above enzymatic reaction, release of CoASH is stoichiometric with the L-carnitine added. The present method has made possible the determination of carnitine in liver tissues, which is difficult by the conventional enzymatic spectrophotometric method using 5,5'-dithiobis(2-nitrobenzoic acid), owing to acetyl-CoA hydrolysis during prolonged incubations at pH 7.8.  相似文献   

15.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed and validated for the measurement of (−)-2′-deoxy-3′-thiacytidine (3TC) in human serum. The method included precipitation of serum proteins by trichloroacetic acid (20%, w/v) treatment followed by centrifugation. The resulting supernatant was directly injected and 3TC was isocratically chromatographed on a reversed-phase C18 column using a mixture of phosphate buffer and methanol (88.3:11.7, v/v) and monitored at 280 nm. The limit of quantitation was 20 ng/ml using 100 μl of serum. The standard curve was linear within the range of 20–10 000 ng/ml. Replicate analysis of three quality control samples (40–1500 ng/ml) led to satisfactory intra- and itner-assay precision (coefficient of variation from 3.0 to 12.9%) and accuracy (deviation from −6.3 to 9.7%). Moreover, sample treatment processes including human immunodeficiency virus (HIV) heat-inactivation, exposure at room temperature and freezing-thawing cycles did not influence the stability of the analyte. This assay was successfully applied to the determination of 3TC serum levels in HIV-infected patients. In addition, preliminary results indicated that this procedure may also be extended to the measurement of 3TC in human plasma and urine.  相似文献   

16.
A method for the analysis of malondialdehyde (MDA) by ion-pairing HPLC is described. The method is direct, no derivitization is required, and sample preparation is minimal. After removal of particulates, the samples are injected directly onto an octadecylsilane column which is eluted with 14% (v/v) acetonitrile in 50 mM myristyltrimethylammonium bromide. 1 mM phosphate, pH 6.8. Detection is accomplished by monitoring absorbance at 254 nm or for greater sensitivity at 267 nm. The lower limit for reliable quantitation is 5 pmol MDA and the dynamic range extends to at least 4 nmol MDA. The method has been applied to the quantitation of MDA production during microsomal lipid peroxidation and to an assessment of the stability of MDA in microsomal and urine samples.  相似文献   

17.
18.
19.
A simple, sensitive and rapid high-performance liquid chromatographic (HPLC) procedure to determine total serum acyclovir concentrations is described. The assay involves a heat inactivation step at 56°C to prevent risk of infection, ultrafiltration as a pretreatment step prior to ion-pair reversed-phase liquid chromatography using guanosine as internal standard, and ultraviolet detection at 254 nm. This method has excellent recovery (97–100%), linearity (0.5–100 mg/l) and precision (1.2–8.0% coefficient of variation). The detection limit is 50 μg/l. The assay proved to be suitable for therapeutic drug monitoring of acyclovir.  相似文献   

20.
An improved method for the determination of glutamate decarboxylase (GAD) activity is described. The enzyme was evaluated by incubation with glutamic acid (l-Glu) in the presence of pyridoxal 5 ′-phosphate (PLP): the γ-aminobutyric acid (GABA) formed was derivatized to PTC-GABA; the latter was subsequently separated and assayed by isocratic HPLC (LiChrospher RP-18 column; isocratic elution with pH 5.8 acetate buffer in acetonitrile-water) with UV absorbance detection at 254 nm. The method described is a sensitive, reproducible and specific assay useful for following variations of GAD activity in vitro; this assay was subsequently used for the evaluation of GAD activity variations after irradiation with low doses of HeNe laser radiation.  相似文献   