首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Methods for the determination of celecoxib in human plasma and rat microdialysis samples using liquid chromatography tandem mass spectrometry are described. Celecoxib and an internal standard were extracted from plasma by solid-phase extraction with C18 cartridges. Thereafter compounds were separated on a short narrow bore RP C18 column (30×2 mm). Microdialysis samples did not require extraction and were injected directly using a narrow bore RP C18 column (70×2 mm). The detection was by a PE Sciex API 3000 mass spectrometer equipped with a turbo ion spray interface. The compounds were detected in the negative ion mode using the mass transitions m/z 380→316 and m/z 366→302 for celecoxib and internal standard, respectively. The assay was validated for human plasma over a concentration range of 0.25–250 ng/ml using 0.2 ml of sample. The assay for microdialysis samples (50 μl) was validated over a concentration range of 0.5–20 ng/ml. The method was utilised to determine pharmacokinetics of celecoxib in human plasma and in rat spinal cord perfusate.  相似文献   

2.
Celecoxib is a cyclooxygenase-2 specific inhibitor, that has been recently and intensively prescribed as an anti-inflammatory drug in rheumatic osteoarthiritis. A robust, highly reliable and reproducible liquid chromatographic–mass spectrometric assay is developed for the determination of celecoxib in human plasma using sulindac as an internal standard. The run cycle-time is <4 min. The assay method involved extraction of the analytes from plasma samples at pH 5 with ethyl acetate and evaporation of the organic layer. The reconstituted solution of the residue was injected onto a Shim Pack GLC-CN, C18 column and chromatographed with a mobile phase comprised of acetonitrile–1% acetic acid solution (4:1) at a flow-rate of 1 ml/min. The mass spectrometer (LCQ Finnigan Mat) was programmed in the positive single-ion monitoring mode to permit the detection and quantitation of the molecular ions of celecoxib and sulindac at m/z 382 and 357, respectively. The peak area ratio of celecoxib/sulindac and concentration are linear (r2>0.994) over the concentration range 50–1000 ng/ml with a lowest detection limit of 20 ng/ml of celecoxib. Within- and between-day precision are within 1.58–4.0% relative standard deviation and the accuracy is 99.4–107.3% deviation of the nominal concentrations. The relative recoveries of celecoxib from human plasma ranged from 102.4 to 103.3% indicating the suitability of the method for the extraction of celecoxib and I.S. from plasma samples. The validated LC–MS method has been utilized to establish various pharmacokinetic parameters of celecoxib following a single oral dose administration of celecoxib capsules in two selected volunteers.  相似文献   

3.
A sensitive and specific high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of minocycline in human plasma and parotid saliva samples. Samples were extracted using an Oasis™ HLB cartridge and were injected into a C8 Nucleosil column. The HPLC eluent contained acetonitrile–methanol–distilled water–0.1% trifluoroacetic acid (25:2:72.9:0.1, v/v). Demeclocycline was used as internal standard. The assay showed linearity in the tested range of 0.1–25 μg/ml. The limit of quantitation was 100 ng/ml. Recovery from plasma or parotid saliva averaged 95%. Precision expressed as %CV was in the range 0.2–17% (limit of quantitation). Accuracy ranged from 93 to 111%. In the two matrices studied at 20 and 4°C, rapid degradation of the drug occurred. Frozen at −30°C, this drug was stable for at least 2 months, the percent recovery averaged 90%. The method’s ability to quantify minocycline with precision, accuracy and sensitivity makes it useful in pharmacokinetic studies.  相似文献   

4.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

5.
A method for the determination of L-756 423, a novel HIV protease inhibitor, in human plasma and urine is described. Plasma and urine samples were extracted using 3M Empore extraction disk cartridges in the C18 and MPC (mixed-phase cation-exchange) formats, respectively. The extract was analyzed using HPLC with fluorescence detection (ex 248 nm, em 300 nm), and included a column switching procedure to reduce run-time. The assay was linear in the concentration range 5 to 1000 ng/ml when 1-ml aliquots of plasma and urine were extracted. Recoveries of L-756 423 were greater than 84% over the calibration curve range using the described sample preparation procedures. Intra-day precision and accuracy for this assay was less than 9% RSD and within 7%, respectively. Inter-day variabilities for the plasma (n=17) and urine (n=10) were less than 5% and 3% for low (15 ng/ml) and high (750 ng/ml) quality control samples. Bovine serum albumin (0.5%) was used as an additive to urine to prevent precipitation of L-756 423 during the storage of clinical samples. The assay was used in support of human clinical trials.  相似文献   

6.
A sensitive method for the enantioselective high-performance liquid chromatography (HPLC) determination of nicardipine in human plasma is described. (+)-Nicardipine, (−)-nicardipine and (+)-barnidipine as an internal standard are detected by an ultraviolet detector at 254 nm. Racemic nicardipine in human plasma was extracted by a rapid and simple procedure based on C18 bonded-phase extraction. The extraction samples were purified and concentrated on a pre-column using a C1 stationary phase and the enantiomers of nicardipine are quantitatively separated by HPLC on a Sumichiral OA-4500 column, containing a chemically modified Pirkle-type stationary phase. Determination of (+)- and (−)-nicardipine was possible in a concentration range of 5–100 ng ml−1 and the limit of detection in plasma was 2.5 ng ml−1. The recoveries of (+)- and (−)-nicardipine added to plasma were 91.4–98.4% and 93.3–96.7%, respectively, with coefficients of variation of less than 9.0 and 9.4% respectively. The method was applied to low level monitoring of (+)- and (−)-nicardipine in plasma from healthy volunteers.  相似文献   

7.
A method for the quantification of 2′-deoxy-3′-thiacytidine (lamivudine, 3-TC), which incorporated the use of 3-isobutyl-methylxanthine as internal standard (I.S.) was developed and validated in human plasma, using HPLC with UV absorbance detection. Using solid-phase extraction, 3-TC and I.S. were selectively extracted from human plasma. Subsequently, chromatographic separation was performed using a YMC phenyl column with ion-pair chromatography and detection at 270 nm. The method was validated over a concentration range of 10 to 5000 ng/ml using 0.5 ml of human plasma. The extraction recovery for both 3-TC and I.S. was greater than 95%. The determination of inter- and intra-day precision (RSD) was less than 10% at all concentration levels, while the inter- and intra-day accuracy (% difference) was less than 6%.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic method was developed to quantify a decapeptide anticoagulant in rat and monkey plasma. The compound and internal standard, a nonapeptide analogue, were extracted from plasma with an amino solid-phase extraction column with an extraction efficiency in the range 75–90%. A C18 analytical column was used to separate the analytes by gradient elution followed by ultraviolet detection at 215 nm. Quantification of the decapeptide over the concentration range 0.1–10.1 μg/ml resulted in an assay relative error and relative standard deviation both less than 10%. The anticoagulant decapeptide was stable in both rat and monkey plasma frozen at −20°C.  相似文献   

9.
A selective HPLC assay is described for the determination of free and total (free plus polymer-bound) camptothecin (CPT) in human plasma after administration of the anti-tumor drug MAG-CPT (polymer bound camptothecin). Total CPT levels were determined after hydrolysis and free CPT was extracted from acidified plasma using Oasis solid-phase extraction material. Extracts were analyzed on a Zorbax SB-C8 analytical column, using a mixture of acetonitrile–25 mM phosphate buffer (pH 4.0) as the eluent. Detection was performed fluorimetrically. Concentrations of polymer-bound CPT were calculated by subtraction of free from total CPT. The lower limits of quantitation of the methods were 100 ng/ml for total and 1.0 ng/ml for free CPT using 50 μl and 250 μl plasma, respectively. Special attention was paid to the stability of the analytes. The presented method was successfully applied in a clinical pharmacokinetic study in our institute.  相似文献   

10.
A rapid, simple and sensitive high-performance liquid chromatographic (HPLC) assay has been developed for the simultaneous quantification of the HIV-protease inhibitors indinavir, amprenavir, ritonavir, saquinavir and nelfinavir in human plasma. The method involved the solid-phase extraction of the five drugs and the internal standard (I.S., verapamil) from 400 μl of human plasma. The HPLC analysis used a reversed-phase C18 analytical column and a mobile phase consisting of a gradient with 15 mM phosphate buffer (pH 5.75)–acetonitrile and UV monitoring. The method was linear over the therapeutic concentration range for the five HIV-protease inhibitors. The accuracy of the method ranged from 98.2 to 106.7% and the precision values ranged from 1.4 to 8.1% for intra-day precision and from 3.1 to 6.4% for the inter-day values.  相似文献   

11.
A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of celecoxib in human plasma. The analysis was carried out on a monolithic silica column using UV detection at 254 nm. The assay enables the measurement of celecoxib for therapeutic drug monitoring with a minimum quantification limit of 10 ng ml(-1). The method involves simple, one-step extraction procedure, and analytical recovery was 100.5 +/- 1.3%. The calibration curve was linear over the concentration range of 10-800 ng ml(-1). The coefficients of variation for inter-day and intra-day assay were found to be less than 8%. We also demonstrate the applicability of this method for pharmacokinetic studies in humans.  相似文献   

12.
The aim of this study was to develop a high-performance liquid chromatographic (HPLC) assay for the determination of moxifloxacin in human plasma and lung tissue. The assay was based on HPLC with a Supelcosil ABZ+ column and ultraviolet detection set at a wavelength of 296 nm. The extraction procedure was characterized by a fully automated liquid–solid extraction using an OASIS column for the solid phase. The assay has been found to be linear and validated over the concentration range 3.2 to 0.025 μg/ml for moxifloxacin in plasma and from 16 to 0.25 μg/g for moxifloxacin in lung tissue. In future, the assay will support the pharmacokinetic study of the penetration of moxifloxacin in human lung tissue.  相似文献   

13.
A simple and precise high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of a novel angiotensin II antagonist, 1-[5-(2-cyclopropyl-5,7-dimethyl-imidazo[4,5-b]pyridin-3-ylmethyl)thiopen-2-yl)cyclopent-3-enecarboxylic acid (CP-191,166, I), in dog and rat plasma. The internal standard (II, a saturated derivative of I) and analyte were extracted by liquid-liquid extraction using methyl tert.-butyl ether. Samples were analyzed by reversed-phase HPLC using a Zorbax C8 narrow-bore column with ultraviolet detection at 289 nm. The quantitation limit of I was 10 ng/ml and the calibration curve was linear over the range of 0.01–10.0 μg/ml (r2>0.99). In dog and rat plasma, intra- and inter-assay precision ranged from 0.00 to 3.36% and 0.00 to 4.95%, respectively. The average recoveries were similar (73%) for both I and II and the upper limit of quantification of I can be as high as 500 μg/ml. The method described has been successfully applied to the quantification of I in about 2000 dog and rat plasma samples over a nine-month period.  相似文献   

14.
Plasma phenobarbital (PB) concentrations in rat offspring were determined using a 9 μl capillary by high-performance liquid chromatography (HPLC). Capillary plasma which was put into a Bond Elut® cartridge column by using 1 ml of 0.01 M KH2PO4 was applied to the column with 50 μl of 2 μg/ml of acetanilide (internal standard, I.S.). After washing the column, PB and I.S. were eluted with methanol and injected into the HPLC system. There were excellent linear correlation between the amount of PB and length of the capillary at three different concentrations. Calibration for PB was linear in the range of 0–50 μg/ml. The coefficients of variation were 3.4–5.0% and 5.9–7.5% in the within-day and between-day assays, respectively. The extraction recovery rates were 87.5–105.4%. By this method, it was possible to measure plasma PB concentrations in rat offspring without killing. These results suggested that this method is very useful to determine the plasma PB concentration derived from mother’s milk in newborn rats.  相似文献   

15.
Two high-performance liquid chromatographic (HPLC) methods are described for determination of (±)-ethopropazine (ET) in rat plasma. After deproteination and liquid–liquid extraction, assay of (±)-ET was performed using either a C18 column (non-stereospecific assay) or an (α-R-naphthyl)ethylurea column (stereospecific assay). The UV detection was at 250 nm. Mean recovery was >85%. Both assays demonstrated excellent linear relationships between peak height ratios and plasma concentrations; quantitation limits were ≤25 ng/ml, based on 100 μl rat plasma. Accuracy and precision were <17% with both methods. Both methods were applied successfully to the measurement of ET plasma concentrations in rats given the drug intravenously.  相似文献   

16.
A rapid and highly sensitive HPLC assay method was developed to measure small amounts of imipramine and its major metabolite, desipramine. The assay involved simple extraction procedures using clomipramine as the internal standard. The mobile phase consisted of acetonitrile (60%) and 0.01 M triethylamine in distilled water (40%) with the pH adjusted to 3.0. Separations were achieved on a C18 column and the effluent measured for UV absorption at 260 nm. The chromatographic separation was excellent, with no interference from endogenous serum constituents. This assay was suitable for measuring drug concentrations in the range of 10–1000 ng/ml using a 0.1-ml serum sample. The method was applied to a drug disposition study in transgenic mice with increased plasma α1-acid glycoprotein.  相似文献   

17.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

18.
A simple method is described for the determination of the cyclooxygenase-2 specific inhibitor celecoxib in human serum by HPLC using the demethylated analogue as internal standard. After protein precipitation with acetonitrile, samples were extracted with chloroform. Separation was achieved on a Prontosil C18 AQ column (150x3 mm I.D., 3-microm particle size) at a flow-rate of 0.35 ml/min using water-acetonitrile (40:60, v/v) as the mobile phase. Using fluorescence detection with excitation at 240 nm and emission at 380 nm, the limit of quantification was 12.5 ng/ml for a sample size of 0.5 ml of serum. The assay was linear in the concentration range of 12.5-1500 ng/ml and showed good accuracy and reproducibility. At all concentrations intra- and inter-assay variabilities were below 11% with less than 9% error. The method was applied to the determination of celecoxib for pharmacokinetic studies in man.  相似文献   

19.
A new HPLC assay method was developed for the simultaneous assay for centpropazine (antidepressant) and its hydroxylated metabolite (II) to assess their pharmacokinetics and metabolism characteristics. Rat serum samples were extracted with ether, backwashed with n-hexane and injected onto the HPLC system, which used a C18 column, gradient elution and fluorescence detection at 250 Ex/350 nm Em. Variations in intra- and inter-batch accuracy and precision were within acceptable limits of <±20% at low and <±15% at higher concentrations. Samples were stable in autosampler prior to injection and after multiple freeze–thaw cycles. Linearity was observed between 0.625 and 20 ng/ml for both I and II in serum. Overall the method developed was highly sensitive and could be employed for a wide range of studies.  相似文献   

20.
A high-performance liquid chromatographic method using column switching was applied to the direct determination of two local anaesthetics, ropivacaine and bupivacaine, in human plasma. The method is intended to be used in a combined LC—GC system; here only the LC-part is described. After addition of internal standard, the samples were filtered and directly injected into a semipermeable surface (SPS) pre-column where the analytes were strongly retained and separated from many endogenous compounds by a short washing step. The retained analytes were transferred by a buffered methanol phase from the pre-column into a carbonaceous HPLC column and they were detected by UV detection at 254 nm. The SPS pre-column could withstand numerous (> 200) direct injections of plasma samples (10 μl). The method has a detection limit of 8.2 ng and requires a total assay time of 15 min per plasma sample. Quantitative recoveries were obtained over the range 3.3–114 μg/ml with inter-day precisions of 1.6–5.2% (C.V.).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号