首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ovarian cells of pregnant rats were cultured with synthetic progestins (R5020, R2323), dexamethasone and RU486. Progesterone and 20 alpha-hydroxy-pregn-4-en-3-one (20 alpha-dihydroprogesterone) in the medium were measured by specific radioimmunoassay. Both R5020 and R2323 increased concentrations of these intrinsic progestins. RU486 decreased concentrations of progesterone, however, the addition of R5020 or R2323 counteracted this action. Immature hypophysectomized rats treated with pregnant mare serum gonadotropin (PMS) and human chorionic gonadotropin (hCG) were administered with RU486; the serum levels of progesterone and 20 alpha-dihydroprogesterone tended to decrease. R5020 and R2323 inhibited the effect of 3 beta-hydroxysteroid dehydrogenase (3 beta-HSD), whereas RU486 did not. Inhibition of the cholesterol side chain cleavage enzyme (CSCC) by RU486 was more marked than that by R5020 or R2323. These results show that RU486 decreases progesterone synthesis in cultured ovarian cells. A part of the mechanism may involve an inhibition of CSCC.  相似文献   

2.
A gas chromatographic method for the sensitive determination of midazolam in plasma volumes as low as 40 μl was developed, utilizing clinazolam as the internal standard. After liquid-liquid extraction at basic pH into 1-chlorobutane-dichloromethane (96:4) a 2- to 4-μl portion of the reconstituted extract was injected under electronic pressure control onto a 12 m × 0.2 mm I.D. methyl silicone capillary column, and was exposed to a three-step temperature program from 120 to 310°C, to separate the analytes from the plasma constituents. The compound of interest was identified and quantified by means of a mass-selective detector. The assay was linear from 10 to 500 ng/ml using 40 μl of plasma (limit of quantification: 10 ng/ml) and was linear from 0.25 to 100 ng/ml using 500 μl of plasma (limit of quantification: 0.25 ng/ml). The intra-day precision for the 40-μl aliquots varied from 2.2 to 6.6%, the corresponding accuracy from −7.4 to −4.4%; the inter-day precision ranged from 5 to 7.2% and the corresponding accuracy from −7.2 to −5.1%.  相似文献   

3.
An isocratic HPLC method was developed and validated for the quantitation of methocarbamol in human plasma. Methocarbamol and internal standard in 200 μl of human plasma were extracted with ethyl acetate, evaporated to dryness and reconstituted in water. Separation was achieved on a reversed-phase C18 column with a mobile phase of methanol—0.1 M potassium phosphate monobasic—water (35:10:55, v/v/v). The detection was by ultraviolet at 272 nm. Linearity was established at 1–100 μg/ml (r > 0.999). The limit of quantitation was designed as 1 μg/ml to suit pharmacokinetic studies. Inter-day precision and accuracy of the calibration standards were 1.0 to 3.6% coefficients of variance (C.V.) and −2.0 to +1.6% relative error (R.E.). Quality controls of 3, 20 and 70 μg/ml showed inter-day precision and accuracy of 2.5 to 3.6% C.V. and −0.9 to −0.4% R.E. Recovery of methocarbamol was 91.4–100.3% in five different lots of plasma. The method was shown to be applicable on different brands of C18 columns.  相似文献   

4.
A highly sensitive and specific method for the determination of josamycin in human plasma by LC–MS was developed and validated. Josamycin was extracted from human plasma by a single-step liquid–liquid extraction and analyzed by LC–MS via an electrospray ionization interface. Selected ion monitoring was used to detect josamycin and its internal standard. The intra-day precision and accuracy, expressed as C.V. and R.E., ranged from 2.8% to 13.5% and −10.3% to 7.6%, respectively. The lower limit of detection was 0.1 ng/ml and the lower limit of quantitation was set at 1 ng/ml when 0.5 ml of plasma was used. No endogenous interference was observed in human plasma obtained from drug-free volunteers.  相似文献   

5.
A sensitive and specific high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of minocycline in human plasma and parotid saliva samples. Samples were extracted using an Oasis™ HLB cartridge and were injected into a C8 Nucleosil column. The HPLC eluent contained acetonitrile–methanol–distilled water–0.1% trifluoroacetic acid (25:2:72.9:0.1, v/v). Demeclocycline was used as internal standard. The assay showed linearity in the tested range of 0.1–25 μg/ml. The limit of quantitation was 100 ng/ml. Recovery from plasma or parotid saliva averaged 95%. Precision expressed as %CV was in the range 0.2–17% (limit of quantitation). Accuracy ranged from 93 to 111%. In the two matrices studied at 20 and 4°C, rapid degradation of the drug occurred. Frozen at −30°C, this drug was stable for at least 2 months, the percent recovery averaged 90%. The method’s ability to quantify minocycline with precision, accuracy and sensitivity makes it useful in pharmacokinetic studies.  相似文献   

6.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed and validated for the measurement of (−)-2′-deoxy-3′-thiacytidine (3TC) in human serum. The method included precipitation of serum proteins by trichloroacetic acid (20%, w/v) treatment followed by centrifugation. The resulting supernatant was directly injected and 3TC was isocratically chromatographed on a reversed-phase C18 column using a mixture of phosphate buffer and methanol (88.3:11.7, v/v) and monitored at 280 nm. The limit of quantitation was 20 ng/ml using 100 μl of serum. The standard curve was linear within the range of 20–10 000 ng/ml. Replicate analysis of three quality control samples (40–1500 ng/ml) led to satisfactory intra- and itner-assay precision (coefficient of variation from 3.0 to 12.9%) and accuracy (deviation from −6.3 to 9.7%). Moreover, sample treatment processes including human immunodeficiency virus (HIV) heat-inactivation, exposure at room temperature and freezing-thawing cycles did not influence the stability of the analyte. This assay was successfully applied to the determination of 3TC serum levels in HIV-infected patients. In addition, preliminary results indicated that this procedure may also be extended to the measurement of 3TC in human plasma and urine.  相似文献   

7.
A sensitive and selective HPLC-solid-phase extraction procedure was developed for the determination of platelet-activating factor antagonist BN-50727 and its metabolites in human plasma. The procedure consisted of an automated solid-phase extraction of the drug and metabolites on disposable propylcarboxylic acid cartridges, followed by on-line chromatographic separation. The method was linear from 3.75 to 2400 ng/ml and the limit of quantitation for BN-50727 in plasma samples was 3.75 ng/ml. The within-run precision of the method, expressed as relative standard deviation, ranged from 2.1 to 8.1%. The accuracy, expressed as relative error, ranged from −3.5 to 4.0%. For the main metabolite, the O-demetthylated BN-50727 product, the method was linear from 7.5 to 2400 ng/ml and the limit of quantitation in plasma was 7.5 ng/ml. The within-run precision ranged from 2.1 to 11.0% and the accuracy from −5.3 to 1.1%. This paper describes the validation of the analytical methodology for the determination of BN-50727 in human plasma and also of its metabolites. The method has been used to follow the time course of BN-50727 and its metabolites in human plasma after administration of single and multiple doses.  相似文献   

8.
A sensitive and stereospecific HPLC method was developed for the analysis of (−)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-β-cyclodextrin (S-β-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)–absolute ethanol (80:20, v/v) containing 10 mM S-β-CD at a flow-rate of 0.7 ml/min. Recoveries of (−)- and (+)-pentazocine were in the range of 91–93%. Linear calibration curves were obtained in the 20–400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9–7.0% and 1.2–6.2%, respectively, for the (−)-enantiomer and 0.8– 7.6% and 1.2–4.6%, respectively, for the (+)-enantiomer (n=3).  相似文献   

9.
An assay for the simultaneous quantitative determination of thioTEPA, TEPA and the recently identified metabolite N,N′-diethylene-N″-2-chloroethylphosphoramide (monochloroTEPA) in human urine has been developed. MonochloroTEPA was synthesized by incubation of TEPA with sodium chloride at pH 8. Thus, with this assay monochloroTEPA is quantified as TEPA equivalents. Analysis of the three analytes in urine was performed using gas chromatography with selective nitrogen–phosphorous detection after extraction with a mixture of 1-propanol and chloroform from urine samples. Diphenylamine was used as internal standard. Recoveries ranged between 70 and 100% and both accuracy and precision were less than 15%. Linearity was accomplished in the range of 25–2500 ng/ml for monochloroTEPA and 25–5000 ng/ml for thioTEPA and TEPA. MonochloroTEPA proved to be stable in urine for at least 4 weeks at −80°C. ThioTEPA, TEPA and monochloroTEPA cummulative urinary excretion from two patients treated with thioTEPA are presented demonstrating the applicability of the assay for clinical samples and that the excreted amount of monochloroTEPA exceeded that of thioTEPA on day 2 to 5 of urine collection.  相似文献   

10.
This paper describes the development of a simple and sensitive analytical method for the quantification of melatonin in human plasma and rabbit serum, using standard analytical equipment and on-line column enrichment without prior extraction, clean-up or derivatization. The analytical procedure was found to be accurate, precise and linear. For human plasma, the accuracy was 101% (range 89–106%), and the mean precision was 5% (range 2–9%) for all concentrations (0, 2, 10, 50 and 200 ng/ml) tested (n=6). The accuracy in rabbit serum was 101% (range 90–112%), and the mean precision was 13% (range 8–19%) for all concentrations (0, 2, 10, 50, 200 and 500 ng/ml) tested (n=6). The retention time of melatonin was about 8 min and the total recoveries were found to be approximately 65 and 85%, respectively, for human plasma and rabbit serum. The limit of detection was found to be lower than 1 ng/ml for human plasma and around 2 ng/ml for rabbit serum. The method is, therefore, found to be suitable for melatonin bioavailability studies in rabbits and presumably also in humans.  相似文献   

11.
The effectiveness of capillary electrophoresis (CE) in the field of stereoselective determination of drugs in biological matrices is demonstrated by analyzing clenbuterol in human urine. Due to the very low therapeutical doses of 20–40 μg per day the total concentrations in urine are 1–10 ng/ml. The sample was extracted with hexane–tert.-butyl methyl ether (99.5:0.5). The reconstituted sample was injected electrokinetically (50 s, 10 kV). Using phosphate buffer, pH 3.3 and hydroxyethyl-β-cyclodextrin as chiral selector the total analysis time was below 15 min. The limit of determination was estimated as 0.5 ng/ml per enantiomer. S-(−)-Bupranolol was used as internal standard. Both precision and accuracy of the method were within the limits for biological samples. The application to human urine from patients having received therapeutical doses showed a slightly predominant excretion of the (+)-enantiomer to the (−)-enantiomer.  相似文献   

12.
A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 μl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid–liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography–tandem mass spectrometry (LC–MS–MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from −8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC–MS–MS are discussed in this paper.  相似文献   

13.
A validated HPLC method for the simultaneous quantitative analysis of the antidepressant mirtazapine and its demethyl metabolite in human plasma is described. The active constituents including internal standard were extracted from 1 ml of plasma with hexane and separated on a μBondapak Phenyl column with fluorescence detection. The lower limit of quantification was 0.5 ng/ml, without significant interferences with endogenous or exogenous components. Inter- and intra-assay accuracy determined at quality control levels of 2, 10 and 80 ng/ml were, respectively, 104.6–113.7% and 105.1–117.7% for mirtazapine, and 91.7–99.3% and 89.9–103.7% for demethylmirtazapine. In all cases the precision was below 6.8%.  相似文献   

14.
We describe a novel sensitive and simplified gradient HPLC assay for quantification of the immunosuppressant mycophenolic acid (MPA) in rat and human plasma. In contrast to previously reported MPA assays, our method used a single step extraction comprising addition of acetonitrile, which contained phenolphthalein glucoronic acid as internal standard, for protein precipitation. Linearity: 0.1–100 μg/ml (r2>0.999), mean recoveries: MPA 98.0%, internal standard 105.2%, mean intra-day precision: 4.3%, mean day-to-day precision: 4.3%, mean day-to-day accuracy: −1.5%. Sensitivity was sufficient to allow for quantification of mycophenolic acid in as little as 50 μl plasma.  相似文献   

15.
A rapid and accurate determination of tetracycline antibiotics in human serum by reversed-phase high-performance liquid chromatography with fluorescence detection has been developed, based on protein precipitation in serum. Various reagents for precipitation were investigated, and 24% trichloroacetic acid in methanolic solution gave the maximum recovery (at least 94.3%) and interference-free chromatograms of different three tetracyclines. At a concentration of 0.5 μg/ml, the precision (relative standard deviation) ranged from 1.12 to 1.94%. In the range 0.04–10.0 μg/ml for oxytetracycline and chlorotetracycline and 0.01–10.0 μg/ml for tetracycline, linear responses were observed. The detection limits of this method were 10–35 ng/ml for all three antibiotics. The proposed method was applied to the determination of serum concentrations in subjects receiving tetracycline antibiotics.  相似文献   

16.
AG 331 is a novel thymidylate synthase inhibitor currently in Phase I clinical trial. To determine the pharmacokinetic parameters of AG 331 in human subjects, a suitable analytical method was developed using high-performance liquid chromatography. Serum and urine samples were prepared using both solid-phase extraction and solvent extraction. Either 4,4′-diaminodiphenyl sulfone or benz[cd]indole-2(1H)-one were used as internal standards for the method. A reversed-phase C18 analytical column completely resolved the drug and internal standard peaks from non-specific substances present in biological matrix. The method was validated for precision, accuracy, and reproducibility in serum and was linear over a concentration range of 50–2000 ng/ml, with a limit of detection of 20.0 ng/ml and a quantifiable limit of 50 ng/ml.  相似文献   

17.
An improved HPLC method using a silica gel column with fluorescence detection (excitation at 300 nm and emission at 365 nm) was developed for the determination of sulpiride concentrations in plasma. Analysis of sulpiride in plasma samples was simplified by a one-step liquid–liquid extraction after alkaline treatment of only 1 ml of plasma. The low limit of quantitation was 20 ng/ml with a coefficient of variation of less than 20%. A linear range was found from 20 to 1500 ng/ml. This HPLC method was validated with the precision for inter-day and intra-day runs being 0.36–8.01% and 0.29–5.25%, respectively, and the accuracy (standard deviation of mean, SD) for inter-day and intra-day runs being −1.58 to 5.02% and −2.14 to 5.21%, respectively. Bioequivalence of the two products was evaluated in 12 normal healthy male volunteers in a single-dose, two-period, two-sequence, two-treatment cross-over study. Sulpiride plasma concentrations were analyzed with this validated HPLC method. Results demonstrated that the two tablet formulations of sulpiride appear to be bioequivalent.  相似文献   

18.
A simple, sensitive and specific liquid chromatography–electrospray tandem mass spectrometry (LC–MS–MS) method for the determination of clindamycin (I) was developed. Both I and verapamil (II, internal standard) were analyzed using a C18 column with a mobile phase of 80% acetonitrile–0.01% trifluoroacetic acid. Column eluents were monitored by electrospray tandem mass spectrometry. Multiple reaction monitoring (MRM) using the parent to daughter combinations of m/z 425→126 and 455→165 was used to quantitate I. A limit of quantitation of 0.0500 μg/ml was found. The assay exhibited a linear dynamic range of 0.0500–20.0 μg/ml and gave a correlation coefficient (r2) of 0.998 or better. The chromatographic run time was approximately 2 min. The intra-batch precision and accuracy of the quality controls (QCs, 0.0500, 0.150, 1.50, 15.0 and 20.0 μg/ml) were characterized by coefficients of variation (CVs) of 5.13 to 13.7% and relative errors (REs) of −4.34 to 4.58%, respectively. The inter-batch precision and accuracy of the QCs were characterized by CVs of 4.35 to 8.32% and REs of −10.8 to −4.17%, respectively. The method has successfully been applied to the analysis of samples taken up to 12 h after oral administration of 300 mg of I in healthy volunteers.  相似文献   

19.
We studied the effect of antiprogesterone RU 486 on spontaneous uterine contractility and PGI2 release with human myometrial strips superfused “in vitro”. A decrease of PGI2 release into the superfusion medium was observed after 20 min superfusion. The inhibition was dose-dependent and reversible. After 20 min washing with tyrode medium without RU 486, the uterine strips recovered their initial rate of release. R5020, a progesterone agonist, did not affect PGI2 release nor dexamethasone and testosterone. Parallel to the decrease of PGI2 observed during RU 486 superfusion, the uterine spontaneous contraction frequency decreased, while the amplitude and duration of contractions increased. The alteration of uterine contractility was also rapid, dose-dependent and reversible. Modifications of uterine strip spontaneous contractility, similar to those induced by RU 486, were also observed with superfusions of R5020 at concentrations as low as 10−9M, dexamethasone (10−8M), but not with superfusions of testosterone. These observations are not in favour of a progesterone-receptor mediated effect of RU 486 in our model. The mechanism of action may be related to the antiprogesterone specific structure i.e. the bulky substituent at the C-11 position. The RU 486 effect on uterine strip contractility, mimicked by other steroids, could point to a non-specific lipid/membrane interaction. However, the fact that testosterone did not affect motility, may indicate a possible specificity of steroids having a 3 oxo pregnene structure.  相似文献   

20.
Aplidine (dehydrodidemnin B) is a new marine-derived depsipeptide with a powerful cytotoxic activity, which is under early clinical investigation in Europe and in the US. In order to investigate the pharmacokinetic properties of this novel drug, an HPLC–tandem mass spectrometry method was developed for the determination of aplidine in biological samples. Didemnin B, a hydroxy analogue, was used as internal standard. After protein precipitation with acetonitrile and extraction with chloroform, aplidine was chromatographed with a RP octadecylsilica column using a water–acetonitrile linear gradient in the presence of formic acid at the flow-rate of 500 μl/min. The method was linear over a 5–100 ng/ml range (LOD=0.5 ng/ml) in plasma and over a 1.25–125 ng/ml range (LOD=0.2 ng/ml) in urine with precision and accuracy below 14.0%. The intra- and inter-day precision and accuracy were below 12.5%. The extraction procedure recoveries for aplidine and didemnin B were 69% and 68%, respectively in plasma and 91% and 87%, respectively in urine. Differences in linearity, LOQ, LOD and recoveries between plasma and urine samples seem to be matrix-dependent. The applicability of the method was tested by measuring aplidine in rat plasma and urine after intravenous treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号