首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The work presented here describes an optimised, reversed-phase high-performance liquid chromatographic (RP-HPLC) method for separating 46 biogenic compounds, which, as neurotoxins or as their precursors or derivatives, may be relevant in the pathomechanism of Parkinson’s disease. In some cases, the physico–chemical properties of these substances are very similar, in other cases they differ greatly. In order to facilitate their detection in one chromatographic run, ion-pair chromatography was uniquely combined with a gradient elution. A diode array or a dual wavelength detector was used in combination with a fluorescence detector to verify the identity of the compounds.  相似文献   

2.
Analysis of plasma catecholamines (norepinephrine, epinephrine and dopamine) by high-performance liquid chromatography using 1,2-diphenylethylenediamine as a fluorescent reagent is described. We have developed an automatic catecholamine analyser, based on pre-column fluorescence derivatization and column switching. The analysis time for one assay was 15 min. The correlation coefficients of the linear regression equations were greater than 0.9996 in the range 10–10 000 pg/ml. The detection limit, at a signal-to-noise ratio of 3, was 2 pg/ml for dopamine. A new method of sample preparation for the pre-column fluorescence derivatization of plasma catecholamines was used. In order to protect the catecholamines from decomposition, an ion-pair complex between boric acid and the diol group in the catecholamine was formed at a weakly alkaline pH. The stabilities of plasma catecholamines were evaluated at several temperatures. After complex formation, the catecholamines were very stable at 17°C for 8 h, and the coefficients of variation for norepinephrine, epinephrine and dopamine were 1.2, 4.2 and 9.3%, respectively.  相似文献   

3.
An HPLC method was developed for the determination of formaldehyde in human blood plasma. The method was based on the determination of the fluorescent product of the chemical reaction between formaldehyde and ampicillin. A 0.2-ml aliquot of blood plasma was reacted directly with ampicillin under acidic and heating conditions. The reaction product was extracted from the matrix with diethyl ether and analyzed by reversed-phase HPLC with fluorescence detection. Recoveries of spiked formaldehyde at the low ppm (μg/ml) level were between 93% and 102% with relative standard deviations less than 8%. The limits of detection and quantitation of formaldehyde in blood plasma samples were 0.46 μg/ml and 0.87 μg/ml, respectively.  相似文献   

4.
Physostigmine (PHY) is an anticholinergic drug used in the treatment of neuromuscular disorders and organophosphate poisoning. We described a sensitive, accurate, and reproducible method for PHY determination in biological materials. The method utilized a liquid/liquid, ion pair extraction, normal phase HPLC separation, and fluorometric quantitation at 240 nm excitation and 360 nm emission wavelength. We used neostigmine as a stabilizing agent to protect PHY from degradation and dimethylphysostigmine as an internal standard. The peak-height ratio vs concentration was linear over a working range from 0.50 to 25.0 ng/ml of PHY in plasma. Sensitivity of the method was 100 pg/ml of plasma which was the limit of quantitative detection under the experimental conditions used. Precision of the method was evaluated using plasma spiked with two concentrations of PHY: 1.0 and 10.0 ng/ml. Intra-day coefficient of variation (CV) ranged from 3.8 to 5.3%, and inter-day CV ranged from 1.8 to 3.6% for the two levels. The average recovery was 92%. We applied the method to examine the stability of PHY in plasma stored at -15 and -80 degrees C. The data indicated that PHY can be stored at either temperature for 9 weeks without undergoing significant alterations.  相似文献   

5.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

6.
A new method for the determination of ofloxacin in human plasma was developed. Plasma proteins were precipitated with acetonitrile, the supernatant concentrated and injected into a reversed-phase C18 column. Enoxacin was used as an internal standard. The fluorimetric detection was performed at 282 nm for excitation and 450 nm for emission. Limit of quantitation was 20 ng/ml and the calibration curve was linear up to 6900 ng/ml.  相似文献   

7.
A simple HPLC method has been developed for the determination of ticlopidine in human plasma. Plasma samples were buffered at pH 9 and extracted with n-heptane-isoamyl alcohol (98.5: 1.5, v/v). Imipramine was used as internal standard. Chromatography was performed isocratically with acetonitrile-methanol-0.05 M KH2PO4 (20:25:55, v/v) at pH 3.0 containing 3% triethylamine at a flow-rate of 1 ml/min. A reversed-phase column, Supelcosil LC-8-DB, 15 cm × 4.6 mm I.D., 5 μm particle size, was used. The effluent was monitored by UV absorbance detection at 235 nm. The method showed good accuracy, precision and linearity in the concentration range 5–1200 ng/ml. The limit of quantitation was 5 ng/ml, with a precision (C.V.) of 8.91%, which is the same as that achieved by other authors with a previously published GC-MS method. The procedure described in this paper is simple and allows the routine assessment of ticlopidine plasma concentration in pharmacokinetic studies following therapeutic doses in human subjects.  相似文献   

8.
Simultaneous microdialysis probes in the blood and brain and sensitive high-performance liquid chromatography with fluorescence detection were used to examine the granisetron concentration in the jugular vein and frontal cortex of rats after drug administration. Two microdialysis probes were inserted into the right jugular vein and frontal cortex of male Sprague–Dawley rats to which granisetron (6 mg/kg, i.v.) had been administered. Dialysates were automatically collected using a microfraction collector. Samples were eluted with a mobile phase containing 25 mM acetate buffer (pH 4.8)–acetonitrile (72:28, v/v). Excitation and emission wavelengths were set at 305 and 360 nm, respectively, on a scanning fluorescence detector. The limit of quantification for granisetron was 0.5 ng/ml. The in vitro recovery of granisetron was 29.7±1.2% (n=6) for the jugular vein microdialysis probe and 6.1±0.5% (n=6) for the frontal cortex microdialysis probe. The increasing brain/blood concentration ratio of granisetron suggests that granisetron penetrates the blood–brain barrier.  相似文献   

9.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection for the determination of vinorelbine in plasma is described. The technique was derived from that published by Debal for an assay of vinorelbine in cell culture medium. The modifications concern the preparation procedure for plasma samples (a two-step liquid-liquid extraction from plasma is desribed), optimization of the mobile phase composition, and use of a single C18 column. These changes resulted in an improved sensitivity and reproducibility of the assay and led to its feasibility for clinical pharmacokinetic studies. The range of the assay is 2 to 1000 ng/ml.  相似文献   

10.
A method for the simultaneous determination of the three selective serotonin reuptake inhibitors (SSRIs) citalopram, fluoxetine, paroxetine and their metabolites in whole blood and plasma was developed. Sample clean-up and separation were achieved using a solid-phase extraction method with C8 non-endcapped columns followed by reversed-phase high-performance liquid chromatography with fluorescence and ultraviolet detection. The robustness of the solid-phase extraction method was tested for citalopram, fluoxetine, paroxetine, Cl-citalopram and the internal standard, protriptyline, using a fractional factorial design with nine factors at two levels. The fractional factorial design showed two significant effects for paroxetine in whole blood. The robustness testing for citalopram, fluoxetine, Cl-citalopram and the internal standard revealed no significant main effects in whole blood and plasma. The optimization and the robustness of the high-performance liquid chromatographic separation were investigated with regard to pH and relative amount of acetonitrile in the mobile phase by a central composite design circumscribed. No alteration in the elution order and no significant change in resolution for a deviation of ±1% acetonitrile and ±0.3 pH units from the specified conditions were observed. The method was validated for the concentration range 0.050–5.0 μmol/l with fluorescence detection and 0.12–5.0 μmol/l with ultraviolet detection. The limits of quantitation were 0.025 μmol/l for citalopram and paroxetine, 0.050 μmol/l for desmethyl citalopram, di-desmethyl citalopram and citalopram-N-oxide, 0.12 μmol/l for the paroxetine metabolites by fluorescence detection, and 0.10 μmol/l for fluoxetine and norfluoxetine by ultraviolet detection. Relative standard deviations for the within-day and between-day precision were in the ranges 1.4–10.6% and 3.1–20.3%, respectively. Recoveries were in the 63–114% range for citalopram, fluoxetine and paroxetine, and in the 38–95% range for the metabolites. The method has been used for the analysis of whole blood and plasma samples from SSRI-exposed patients and forensic cases.  相似文献   

11.
12.
A sensitive and specific HPLC method has been developed for the assay of amlodipine in human plasma. The assay involves derivatization with 4-chloro-7-nitrobenzofurazan (NBD-Cl), solid-phase extraction on a silica column and isocratic reversed-phase chromatography with fluorescence detection. Nortriptyline hydrochloride was used as an internal standard. The assay was linear over the concentration range of 0.25–18.00 ng/ml. Both of the within-day and day-to-day reproducibility and accuracy were less than 11.80% and 12.00%, respectively. The plasma profile following a single administration of 10 mg amlodipine to a healthy volunteer was presented.  相似文献   

13.
KW-2170, 5-(3-aminopropyl) amino-7,10-dihydroxy-2-(2-hydroxethyl)-aminoethyl-6H-pyrazolo [4,5,1-de] acridin-6-one dihydroxychloride, is a novel anticancer agent under clinical development. We have established a highly sensitive method which can simultaneously quantitate KW-2170 and its two metabolites, a carboxylic (M1) and hydroxylated (M2) derivative involving the 5-position, in human and dog plasma. KW-2170 and its metabolites were extracted from plasma using a weak cation-exchange cartridge and then determined by HPLC using an electrochemical detector (ED). Over the concentration range 0.1-50 ng/ml, precision and accuracy of intra- and inter-day assay were within 11% in human plasma. In dog plasma, they were within 17% at the lower quantitation limit and within 11% at other concentrations. These three compounds were stable during the assay procedure, freeze-thawing cycles and during long-term storage. Using this methodology, the pharmacokinetics of KW-2170 in a dog could be monitored over 24 h. This method is suitable for evaluation of the detailed pharmacokinetics of KW-2170 and its metabolites in humans and dogs.  相似文献   

14.
The influence of the pH of the mobile phase with some modifiers on the chromatographic behavior and fluorescence properties of closantel have been investigated. At acidic pH values (2–6), the benzamide moiety of the closantel forms a six-membered ring by hydrogen bonding and possesses a native fluorescence. Using the fluorescence emission of closantel at λex=335 nm, λem=510 nm, and pH 2.5 of the mobile phase, a linear calibration curve was estimated over a concentration range of about two orders of magnitude with a correlation coefficient larger than 0.992. The limit of the fluorescence detection was 10 μg/kg. This value was at least 10 times lower than that using UV detection. The method was applied to the determination of closantel in plasma and tissue samples, purified by a solid-phase extraction with C18 cartridges.  相似文献   

15.
A simple, sensitive and fully automated analytical method for the analysis of codeine in human plasma is presented. Samples are added with oxycodone, used as internal standard (I.S.), and directly loaded in the autosampler tray. An on-line sample clean-up system based on solid-phase extraction (SPE) cartridges (Bond-Elut C2, 20 mg) and valve switching (Prospekt) is used. Isocratic elution improved reproducibility and allowed the recirculation of the mobile phase. A Hypersil BDS C18, 3 μm, 10×0.46 cm column was used and detection was done by UV monitoring at 212 nm. Retention times of norcodeine (codeine metabolite), codeine and oxycodone (I.S.) were 5.5, 6.4 and 9.1 min, respectively. Morphine was left to elute in the chromatographic front. Detection limit for codeine was 0.5 μg l−1 and inter-assay precision (expressed as relative standard deviation) and accuracy (expressed as relative error) measured at 2 μg l−1 were 5.03% and 1.82%. Calibration range was 2–140 μg l−1.  相似文献   

16.
17.
A rapid, reproducible high-performance liquid chromatographic method for the determination of secnidazole, 5-nitroimidazole class of antiprotozoals from blood is described. Metronidazole was used as an internal standard. A simple extraction step with dichloromethane was done before chromatography on a C18 column with the wavelength fixed at 276 nm on the UV detector. Blood levels up to 500 ng/ml have been measured with good precision in the healthy volunteers after 1 g of secnidazole was administered. The present described method can readily be utilized for routine pharmacokinetic studies.  相似文献   

18.
A simple and sensitive high-performance liquid chromatographic (HPLC) method is established for the trace determination of tobramycin in human plasma by derivatization. The method is based on the chemical derivatization of aminoglycoside antibiotic, tobramycin in human plasma, with 1-naphthyl isothiocyanate (NITC) in pyridine at 70 degrees C. After derivatization reaction, a methylamine/acetonitrile solution was added to the reaction mixture to eliminate the excess derivatizing agent and shorten the analysis time. The resulting derivative was separated using a Purospher STAR RP-18e column and a water-acetonitrile (50:50, v/v) mobile phase (detection at 230 nm). Optimization conditions for the derivatization of tobramycin were investigated by HPLC. The linear range for the quantitation of tobramycin in spiked plasma was over 0.93-9.34 mg/l; the detection limit (signal-to-noise ratio=3; injection volume, 10 microl) was about 0.23 mg/l. The relative standard deviation was less than 2.1% for intra-day assay (n=6) and 5.2% for inter-day assay (n=6) and relative recoveries were found greater than 99%.  相似文献   

19.
A method of analysis for the determination of alosetron in human plasma or serum has been developed. The method was fully automated using a laboratory robot in order to improve analytical precision, efficiency and safety. The assay involved solid-phase extraction with reversed-phase HPLC separation and fluorescence detection. A validation exercise over the concentration range of 0.1 to 20 ng/ml demonstrated the selectivity, linearity, sensitivity, accuracy, precision, extraction efficiency, ruggedness and stability of the method. The method has been applied in support of numerous human pharmacokinetic/biopharmaceutic studies over the last five years.  相似文献   

20.
A comprehensive on-line sample clean-up with an integrated two-dimensional HPLC system was developed for the analysis of natural peptides. Samples comprised of endogenous peptides with molecular weights up to 20 kDa were generated from human hemofiltrate (HF) obtained from patients with chronic renal failure. The (poly-)peptides were separated using novel silica-based restricted access materials with strong cation-exchange functionalities (SCX-RAM). The size-selective sample fractionation step is followed by cation-exchange chromatography as the first dimension. The subsequent second dimension of separation is based on hydrophobic interaction using four parallel short reversed-phase (RP) columns implemented via a fully automated column switching technique. More than 1000 peaks were resolved within the total analysis time of 96 min. Substances of selected peaks were sampled to analyse their molecular weights by off-line MALDI-TOF mass spectrometry and to determine their amino acid sequence by Edman degradation. The potential for comprehensive peptide mapping and identification is demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号