首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A gradient reversed-phase HPLC analysis for the direct measurement of gemfibrozil (GEM) and four oxidative metabolites in plasma and urine of humans and in tissue homogenates of rats was developed. The corresponding acyl glucuronides and the covalently bound protein adducts (in protein precipitates) were determined after liberation from the respective conjugates via alkaline hydrolysis. The limits of detection for the covalent adducts in human plasma are: 10 ng ml−1 (GEM), 20 ng ml−1 (M1), 0.5 ng ml−1 (M2, M4), and 5 ng ml−1 (M3). The method was validated with respect to selectivity, recovery, linearity, precision, and accuracy. It has been applied to the analysis of preclinical and clinical studies. Pharmacokinetic profiles of gemfibrozil, its metabolites, and covalent adducts in human plasma and rat tissue homogenates are given.  相似文献   

2.
Benzene is an important industrial chemical and, due to its occurrence in mineral oil and its formation in many combustion processes, a widespread environmental pollutant. Since benzene is hematoxic and has been classified as a human carcinogen, monitoring and control of benzene exposure is of importance. Although trans,trans-muconic acid (ttMA) was identified as a urinary metabolite of benzene at the beginning of this century, only recently has its application as a biomarker for occupational and environmental benzene exposure been investigated. The range of metabolic conversion of benzene to ttMA is about 2–25% and dependent on the benzene exposure level, simultaneous exposure to toluene, and probably also to genetic factors. For the quantitation of ttMA in urine, HPLC methods using UV and diode array detection as well as GC methods combined with MS or FID detection have been described. Sample pretreatment for both HPLC and GC analysis comprises centrifugation and enrichment by solid-phase extraction on anion-exchange sorbents. Described derivatization procedures prior to GC analysis include reaction with N,O-bis(trimethysilyl)acetamide, N,O-bis(trimethylsilyl)trifluoroacetamide, pentafluorobenzyl bromide and borontrifluoride–methanol. Reported limits of detection for HPLC methods range from 0.1 to 0.003 mg l−1, whereas those reported for GC methods are 0.03–0.01 mg l−1. Due to its higher specificity, GC methods appear to be more suitable for determination of low urinary ttMA levels caused by environmental exposure to benzene. In studies with occupational exposure to benzene (>0.1 ppm), good correlations between urinary ttMA excretion and benzene levels in breathing air are observed. From the reported regressions for these variables, mean excretion rates of ttMA of 1.9 mg g−1 creatinine or 2.5 mg l−1 at an exposure dose of 1 ppm over 8 h can be calculated. The smoking-related increase in urinary ttMA excretion reported in twelve studies ranged from 0.022 to 0.2 mg g−1 creatinine. Only a few studies have investigated the effect of exposure to environmental levels of benzene (<0.01 ppm) on urinary ttMA excretion. A trend for slightly increased ttMA levels in subjects living in areas with high automobile traffic density was observed, whereas exposure to environmental tobacco smoke did not significantly increase the urinary ttMA excretion. It is concluded that urinary ttMA is a suitable biomarker for benzene exposure at occupational levels as low as 0.1 ppm. Biomonitoring of exposure to environmental benzene levels (<0.01 ppm) using urinary ttMA appears to be possible only if the ingestion of dietary sorbic acid, another precursor to urinary ttMA, is taken into account.  相似文献   

3.
The aim of this study was to establish an easy and accurate method for the determination of bisphenol-A (BPA) in the body liquid such as serum and urine. Two high-performance liquid chromatography (HPLC) systems, HPLC with electrochemical detector (ED), and HPLC with mass spectrometry (MS) using electrospray ionization (ESI) interface were used for the assay in the serum samples prepared with solid-phase extraction method. Water or EtOH at a concentration below 50% was suitable for the extraction of BPA from serum. The limit of detection of BPA was 0.2 ng ml−1 for the HPLC-ED method and 0.1 ng ml−1 for HPLC–MS. There was a good correlation between the data obtained by the two HPLC systems. BPA concentrations in healthy human serum were low (0–1.6 ng ml−1). From various commercial fetal bovine serum and sheep plasma, however, significant amounts of BPA were detected. Since no BPA was detected from sheep plasma immediately after collection, the high amounts of BPA were considered to be caused by the handling of blood during the preparation of the products after blood collection. In vitro study showed that the amount of BPA leached from polycarbonate tube into sheep plasma were 40 times larger than those into water and the leached amount of BPA depended on the temperature (37°C>20°C>5°C).  相似文献   

4.
Determination of

A simple, rapid and sensitive two column-switching high-performance liquid chromatographic (HPLC) method with ultraviolet detection at 210 nm has been developed for the determination of

(AY4166, I) and its seven metabolites in human plasma and urine. Measurements of I and its metabolites were carried out by two column-switching HPLC, because metabolites were classified into two groups according to their retention times. After purification of plasma samples using solid-phase extraction and direct dilution of urinary samples, I and each metabolite were injected into HPLC. The calibration graphs for plasma and urinary samples were linear in the ranges 0.1 to 10 μg ml−1 and 0.5 to 50 μg ml−1, respectively. Recoveries of I and its seven metabolites were over 88% by the standard addition method and the relative standard deviations of I and its metabolites were 1–6%.  相似文献   

5.
Analytical methods are described for the selective, rapid and sensitive determination of R- and S-apomorphine, apocodeine and isoapocodeine and the glucuronic acid and sulfate conjugates in plasma and urine. The methods involve liquid-liquid extraction followed by high-performance liquid chromatography with electrochemical detection. The glucuronide and sulfate conjugates are determined after enzymatic hydrolysis. For the assay of R- and S-apomorphine a 10 μm Chiralcel OD-R column is used and the voltage of the detector is set at 0.7 V. The mobile phase is a mixture of aqueous phase (pH 4.0)-acetonitrile (65:35, v/v). At a flow-rate of 0.9 ml min−1 the total run time is ca. 15 min. The detection limits are 0.3 and 0.6 ng ml−1 for R- and S- apomorphine, respectively (signal-to-noise ratio 3). The intra- and inter-assay variations are <5% in the concentration range of 2.5-25 ng ml−1 for plasma samples, and <4% in the concentration range of 40-400 ng ml−1 for urine samples. For the assay of apomorphine, apocodeine and isoapocodeine, a 5 μm C18 column was used and the voltage of the detector set at 0.825 V. Ion-pairing chromatography was used. The mobile phase is a mixture of aqueous phase (pH 3.0)-acetonitrile (75:25, v/v). At a flow-rate of 0.8 ml min−1 the total run time is ca. 14 min. The detection limits of this assay are 1.0 ng ml−1 for apomorphine and 2.5 ng ml−1 for both apocodeine and isoapocodeine (signal-to-noise ratio 3). The inter-assay variations are 5% in the concentration range of 5-40 ng ml−1 for plasma samples and 7% in the concentration range of 50-500 ng ml−1 for urine samples. The glucuronic acid and sulfate conjugates of the various compounds are hydrolysed by incubation of the samples with β-glucuronidase and sulfatase type H-1, respectively. Hydrolysis was complete after 5 h of incubation. No measurable degradation of apomorphine, apocodeine and isoapocodeine occurred during the incubation. A pharmacokinetic study of apomorphine, following the intravenous infusion of 30 μg kg−1 for 15 min in a patient with Parkinson's disease, demonstrates the utility of the methods: both the pharmacokinetic parameters of the parent drug and the appearance of apomorphine plus metabolites in urine could be determined.  相似文献   

6.
Production of two eicosanoids derived from lipoxygenase and cyclooxygenase activities: leukotriene B4 (LTB4) and prostaglandin E2 (PGE2), respectively, have been simultaneously determined in turbot (Scophthalmus maximus) blood leucocyte and kidney macrophage supernatants by a reverse phase high performance liquid chromatography (HPLC) system coupled with a Diode–Array detector. Levels of LTB4 after calcium ionophore challenge were 4.08 ng ml−1 in blood leukocyte supernatants and 0.25 ng ml−1 in kidney macrophage supernatants. The levels found for PGE2 were 428.23 and 606.67 ng ml−1 in blood leukocytes and kidney macrophage supernatants, respectively. When blood leukocytes were treated with the respective inhibitors for the enzymes implicated on the synthesis of both compounds an inhibition of 90.35% was observed for PGE2 and 76.44% for LTB4. The detection limit of the method was 0.15 ng ml−1 for LTB4 and 50 ng ml−1 for PGE2.  相似文献   

7.
A sensitive method for the enantioselective high-performance liquid chromatography (HPLC) determination of nicardipine in human plasma is described. (+)-Nicardipine, (−)-nicardipine and (+)-barnidipine as an internal standard are detected by an ultraviolet detector at 254 nm. Racemic nicardipine in human plasma was extracted by a rapid and simple procedure based on C18 bonded-phase extraction. The extraction samples were purified and concentrated on a pre-column using a C1 stationary phase and the enantiomers of nicardipine are quantitatively separated by HPLC on a Sumichiral OA-4500 column, containing a chemically modified Pirkle-type stationary phase. Determination of (+)- and (−)-nicardipine was possible in a concentration range of 5–100 ng ml−1 and the limit of detection in plasma was 2.5 ng ml−1. The recoveries of (+)- and (−)-nicardipine added to plasma were 91.4–98.4% and 93.3–96.7%, respectively, with coefficients of variation of less than 9.0 and 9.4% respectively. The method was applied to low level monitoring of (+)- and (−)-nicardipine in plasma from healthy volunteers.  相似文献   

8.
Determination of four toxic Aconitum alkaloids, aconitine, mesaconitine, hypaconitine and jesaconitine, in blood and urine samples has been established using high-performance liquid chromatography (HPLC) combined with ultraviolet absorbance detection, solid-phase extraction and mass spectrometry (MS). These alkaloids were hydrolyzed rapidly in alkaline solution (half lives (t1/2)<one day), were stable in solutions of acetonitrile, tetrahydrofuran and diluted hydrochloric acid (t1/2>five months) and were unstable in solutions of methanol and ethanol (t1/2<one month). These alkaloids were separated on an octadecylsilica column with isocratic elution using a solvent mixture of tetrahydrofuran and 0.2% trifluoroacetic acid (14:86, v/v), which was found to be the optimal solvent of the elution systems examined. Calibration curves with UV detection were linear on injection of amounts ranging from 2.5 to 500 ng, and the limit of detection was 1 ng (S/N = 3). These four alkaloids in aqueous solution were recovered almost totally by solid-phase extraction using the styrene polymer resin, Sep-Pak Plus PS-1, and were eluted using a mixture of acetonitrile and hydrochloric acid. These Aconitum alkaloids were confirmed by HPLC coupled with fast atom bombardment MS, giving their protonated molecular ions as base peaks. These alkaloids were detected by HPLC with UV detection from blood samples spiked with more than 50 ng ml−1 of alkaloids, but were not detectable from urine samples spiked with 5 μg ml−1 of alkaloids because of severe sample interference.  相似文献   

9.
《Biomarkers》2013,18(6):553-562
The relationship between deoxynivalenol (DON) intake and first morning urinary DON was examined in UK adults to validate the latter as a biomarker of human exposure. DON was assessed in first morning samples collected during a period of normal diet, a wheat-restriction intervention diet, and partial wheat-restriction intervention in which bread was allowed. During the partial intervention duplicate bread portions were collected for DON analysis. During the normal diet, partial intervention and full intervention, urinary DON was detected in 198/210 (geometric mean 10.1?ng DON mg?1 creatinine, 95% confidence interval (CI) 8.6–11.6?ng mg?1; range nd–70.7?ng mg?1), in 94/98 (5.9?ng mg?1, 95% CI 4.8–7.0?ng mg?1; range nd–28.4?ng mg?1), and 17/40 (0.5?ng mg?1, 95% CI 0.3–0.7?ng mg?1; range nd–3.3?ng mg?1) volunteers, respectively. A strong correlation between DON intake and the urinary biomarker was observed (p <0.001, adjusted r2?=?0.83) in models adjusting for age, sex and body mass index. These data demonstrate a quantitative correlation between DON exposure and urinary DON, and serve to validate the use of urinary DON as an exposure biomarker.  相似文献   

10.
An HPLC method for determining a flavonoid naringin and its metabolite, naringenin, in human urine is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using hesperidin for naringin or hesperetin for naringenin as internal standard and solid-phase extraction using a strong anion exchanger, Sep-Pak Accell QMA cartridge. The HPLC assay was carried out using an Inertsil ODS-2 column (250×4.6 mm I.D., 5 μm particle size). The mobile phases were acetonitrile–0.1 M ammonium acetate–acetic acid (18:81:1, v/v; pH 4.7) for naringin and acetonitrile–0.1 M ammonium acetate–triethylamine (25:75:0.05; v/v; pH 8.0) for naringenin. The flow-rate was 1.0 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 282 nm for naringin and at 324 nm for naringenin. The lower limits of quantification were ca. 25 ng/ml for naringin and naringenin with R.S.D. less than 10%. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 5 ng for naringin and 1 ng for naringenin. A preliminary experiment to investigate the urinary excretion of naringin, naringenin and naringenin glucuronides after oral administration of 500 mg of naringin to a healthy volunteer demonstrated that the present method was suitable for determining naringin and naringenin in human urine.  相似文献   

11.
Thromboxane B2 (TxB) is excreted in human urine, but the mechanism of renal excretion and the quantitative relationship of urinary TxB to the active parent compound, thromboxane A2, of renal or extrarenal origin is not established. To determine the effects of vasoactive hormones, uricosuric agents and urinary flow rate on TxB excretion, urinary TxB was measured by radioimmunoassay and mass spectrometry, and renal metabolism of blood TxB was determined by radiochromatography of urine after i.v. [3H]-TxB infusions. Basal TxB was 6.7 ± 1.1 ng/h during an oral water load, and TxB fell with s.q. antidiuretic hormone (to 3.4 ± 0.4 ng/h, P<0.01) and with fluid restriction (to 2.6 ± 0.5 ng/hr, P=0.001) in parallel with urinary volume. Urinary excretion of unmetabolized [3H]-TxB also fell (by 56%) with fluid restriction, implicating altered metabolism rather than synthesis as the mechanism of the urinary flow effect. Angiotensin II infusions slightly reduced both TxB and urine volume, consistent with a flow effect. In contrast, probenecid did not alter urine volume, but increased urinary uric acid (by 244%), TxB (from 5.6 ± 0.9 to 11.1 ± 2.9 ng/h) and urinary excretion of blood [3H]-TxB (by 243%) by similar amounts (all P<0.05), suggesting that TxB is actively reabsorbed in the proximal tubule, similarly to uric acid. Thus, urinary excretion of TxB of renal and extrarenal origin is regulated by proximal and distal tubule factors.  相似文献   

12.
Separation in capillary electrophoresis is governed by various factors, including buffer type, buffer concentration, pH, temperature, voltage and micelles. Through proper adjustment of these parameters, nalidixic acid and its two major metabolites, 7-hydroxynalidixic and 7-carboxynalidixic, could be separated by micellar electrokinetic capillary chromatography using an electrophoretic electrolyte consisting of 50 mM borate buffer (pH 9) containing 25 mM sodium dodecyl sulphate and 10% acetonitrile. A linear relationship between concentration and peak area for each compound was obtained in the concentration range 0.15–100 μg ml−1, with a correlation coefficient greater than 0.999 and detection limits in the 0.2–0.7 ng ml−1 range. Intra- and inter-day precision values of about 0.8–1.2% RSD (n=11) and 1.3–2.0% RSD (n=30), respectively, were obtained. The method has been applied to the analysis of nalidixic acid and its two major metabolites in serum and urine with limits of sensitivity lower than 0.8 ng ml−1.  相似文献   

13.
Anabaena siamensis isolated from rice fields in Thailand is a fast growing cyanobacterium with a high nitrogen-fixing activity. Mutant strains resistant to the l-glutamate analogue, l-methionine sulfoximine (MSX) were isolated by ethyl methanesulfonate mutagenesis. A stable mutant named A. siamensis SS1, which released ammonium to the medium, was studied further. In batch cultures the rate of ammonium production peaked at the early log phase and gradually decreased until the 4th day of growth when the cultures reached a density of 90 μg chl ml−1. To obtain constant release of ammonium by SS1, continuous culture experiments were performed at a cell density of 5 μg chl ml−1 and the following results were obtained: (1) growth rate as the parent (μ:0·123 h−1) in the presence and absence of 500 μm MSX; (2) 48% GS transferase activity when compared with the parent; (3) ammonium excretion at a rate of 8 μmol (mg chl)−1 h−1 as measured up to 20 generations (120 h); (4) depressed nitrogenase activity; and (5) 30% higher nitrogenase activity than that of the parent. SS1 immobilized in alginate beads (5 μg chl ml−1) exhibited values of glutamine synthetase and nitrogenase activity similar to those of free cells. However, ammonium excretion at the rate of 11·61 μmol (mg chl)−1 h−1 was obtained only up to 20 h after loading in bioreactors, due to the fast growth of SS1 as also occurred in batch cultures.  相似文献   

14.

Background

Little is known about muscle mass loss in early stage chronic kidney disease (CKD). We used 24-hour urinary creatinine excretion rate to assess determinants of muscle mass and its evolution with kidney function decline. We also described the range of urinary creatinine concentration in this population.

Methods

We included 1072 men and 537 women with non-dialysis CKD stages 1 to 5, all of them with repeated measurements of glomerular filtration rate (mGFR) by 51Cr-EDTA renal clearance and several nutritional markers. In those with stage 1 to 4 at baseline, we used a mixed model to study factors associated with urinary creatinine excretion rate and its change over time.

Results

Baseline mean urinary creatinine excretion decreased from 15.3±3.1 to 12.1±3.3 mmol/24 h (0.20±0.03 to 0.15±0.04 mmol/kg/24 h) in men, with mGFR falling from ≥60 to <15 mL/min/1.73 m2, and from 9.6±1.9 to 7.6±2.5 (0.16±0.03 to 0.12±0.03) in women. In addition to mGFR, an older age, diabetes, and lower levels of body mass index, proteinuria, and protein intake assessed by urinary urea were associated with lower mean urinary creatinine excretion at baseline. Mean annual decline in mGFR was 1.53±0.12 mL/min/1.73 m2 per year and that of urinary creatinine excretion rate, 0.28±0.02 mmol/24 h per year. Patients with fast annual decline in mGFR of 5 mL/min/1.73 m2 had a decrease in urinary creatinine excretion more than twice as big as in those with stable mGFR, independent of changes in urinary urea as well as of other determinants of low muscle mass.

Conclusions

Decrease in 24-hour urinary creatinine excretion rate may appear early in CKD patients, and is greater the more mGFR declines independent of lowering protein intake assessed by 24-hour urinary urea. Normalizing urine analytes for creatininuria may overestimate their concentration in patients with reduced kidney function and low muscle mass.  相似文献   

15.
The four stereoisomers of the combined α- and β-adrenoceptor antagonist labetalol were separated and quantified at therapeutic concentrations by normal-phase high-pressure liquid chromatography using a chiral stationary phase and fluorescence detection. Drug in plasma or urine was recovered by solid-phase extraction with 83±5% efficiency. Limits of detection from biological samples (3 ml) were between 1.5–1.8 ng ml−1. Intra-day and inter-day variation at 25 ng ml−1 were ≤2.7% and ≤5.80% respectively for all stereoisomers. The assay was applied to an examination of the disposition of labetalol stereoisomers after a single oral dose of racemate to a human volunteer. Labetalol appears to undergo enantioselective metabolism leading to relatively low plasma concentrations of the pharmacologically active enantiomers.  相似文献   

16.
The gadobenate ion is an intravascular paramagnetic contrast agent for magnetic resonance imaging. An HPLC method for assaying gadobenate ion in plasma, urine, faeces, bile and tissue samples is described. The analysis is based on the reversed-phase chromatographic separation of gadobenate ion from the endogenous components of biological matrices and detection by UV absorption at 210 nm. The selectivity of the method was satisfactory. The mean absolute recovery was greater than 95%. The precision and accuracy of the analytical methods were in the range 0.1–6.5% and −12 to +9.3%, respectively. The detection limits in plasma (0.1 ml), urine (0.05 ml), dried faeces (200 mg suspended in 4 ml water), bile (0.5 ml), and dried liver tissue (100 mg suspended in 1 ml water) were, respectively, 0.24, 0.47, 2.6, 0.63 and 2.8 nmol ml−1 (corresponding to 0.16, 0.31, 1.7, 0.42 and 1.9 μg ml−1).  相似文献   

17.
 The energy demand during physical exercise causes an increased oxygen uptake and supply to active tissues, which may increase the rate of free oxygen radical production and thereby affect the capacity of endogenous cellular defense systems. This could result in DNA base modifications, among which 8-hydroxydeoxyguanosine (8OHdG) is one of the most important and has widely been used as a biomarker of in vivo oxidative lesions. Therefore, we examined the effect of regular running exercise on the urinary levels of 8OHdG in 32 long-distance runners and in a group of untrained healthy subjects. The range of 8OHdG in urine was 0.12–6.45 μmol/mol creatinine in both groups, and no significant difference in the mean excretion levels between runners and control probands was observed. This gives no reason to believe that physical exercise in trained individuals may induce a disturbance of the oxidant-to-antioxidant balance. Accepted: 30 January 1997  相似文献   

18.
A flow-type enzyme immunosensor was prepared for the electrochemical determination of human serum albumin (HSA). The immunosensor was constructed from the immobilized antibody (anti-HSA IgG) reactor and an oxygen electrode. The immunochemical reaction of catalase-labelled antibody with HSA was completed with 30 min. After the immunochemical reaction, hydrogen peroxide solution was injected into the system and a peak current was obtained within 2 min. A linear relationship was observed between the current increase and the logarithm of HSA concentration in the range 10−8-10−6 g ml−1. The minimum measurable concentration was 10−8 g ml−1. The current increase was reproducible with 10% of the relative errors when a sample solution containing 10−7 g ml−1 of HSA was used. The minimum measurable concentration increased to 10−9 g ml−1 when hydrogen peroxide was recycled for 5 min in the reactor system. The immobilized antibody reactor could be reused. HSA in human serum was determined by the system proposed.  相似文献   

19.
Fragments of chopped lung from indomethacin treated guinea-pigs had an anti-aggregating effect when added to human platelet rich plasma (PRP), probably due to the production of prostacyclin (PGI2) since the effect was inhibited by 15-hydroperoxy arachidonic acid (15-HPAA, 10 μg ml−1). Both 15-HPAA (1–20 μg ml−1 min−1) and 13-hydroperoxy linoleic acid (13-HPLA, 20 μg ml−1 min−1) caused a marked enhancement of the anaphylactic release of histamine, slow-reacting substance of anaphylaxis (SRS-A) and rabbit aorta contracting substance (RCS) from guinea-pig isolated perfused lungs. This enhancement was not reversed by the concomitant infusion of either PGI2 (5 μg ml−1 min−1) or 6-oxo-prostaglandin F (6-oxo-PGF, 5 μg ml−1 min−1). Anaphylactic release of histamine and SRS-A from guinea-pig perfused lungs was not inhibited by PGI2 (10 ng - 10 μg ml−1 min−1) but was inhibited by PGE2 (5 and 10 μg ml−1 min−1). Antiserum raised to 5,6-dihydro prostacyclin (PGI1) in rabbits, which also binds PGI2, had no effect on the release of anaphylactic mediators. The fatty acid hydroperoxides may enhance mediator release either indirectly by augmenting thromboxane production or by a direct effect on sensitized cells. Further experiments to distinguish between these alternatives are described in the accompanying paper (27).  相似文献   

20.

Background

Vitamin-D-binding protein (VDBP) is a low molecular weight protein that is filtered through the glomerulus as a 25-(OH) vitamin D 3/VDBP complex. In the normal kidney VDBP is reabsorbed and catabolized by proximal tubule epithelial cells reducing the urinary excretion to trace amounts. Acute tubular injury is expected to result in urinary VDBP loss. The purpose of our study was to explore the potential role of urinary VDBP as a biomarker of an acute renal damage.

Method

We included 314 patients with diabetes mellitus or mild renal impairment undergoing coronary angiography and collected blood and urine before and 24 hours after the CM application. Patients were followed for 90 days for the composite endpoint major adverse renal events (MARE: need for dialysis, doubling of serum creatinine after 90 days, unplanned emergency rehospitalization or death).

Results

Increased urine VDBP concentration 24 hours after contrast media exposure was predictive for dialysis need (no dialysis: 113.06 ± 299.61ng/ml, n = 303; need for dialysis: 613.07 ± 700.45 ng/ml, n = 11, Mean ± SD, p<0.001), death (no death during follow-up: 121.41 ± 324.45 ng/ml, n = 306; death during follow-up: 522.01 ± 521.86 ng/ml, n = 8; Mean ± SD, p<0.003) and MARE (no MARE: 112.08 ± 302.00ng/ml, n = 298; MARE: 506.16 ± 624.61 ng/ml, n = 16, Mean ± SD, p<0.001) during the follow-up of 90 days after contrast media exposure. Correction of urine VDBP concentrations for creatinine excretion confirmed its predictive value and was consistent with increased levels of urinary Kidney Injury Molecule-1 (KIM-1) and baseline plasma creatinine in patients with above mentioned complications. The impact of urinary VDBP and KIM-1 on MARE was independent of known CIN risk factors such as anemia, preexisting renal failure, preexisting heart failure, and diabetes.

Conclusions

Urinary VDBP is a promising novel biomarker of major contrast induced nephropathy-associated events 90 days after contrast media exposure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号