首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 μl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid–liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography–tandem mass spectrometry (LC–MS–MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from −8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC–MS–MS are discussed in this paper.  相似文献   

2.
A liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed for the quantitation of urinary leukotriene E4 (LTE4). LTE4 and its internal standard were extracted by solid-phase extraction and analysed using LC–MS–MS in the selected reaction monitoring (SRM) mode. A good linear response over the range of 10 pg to 10 ng was demonstrated. The accuracy of added LTE4 ranged from 97.0% to 108.0% with a mean and SD of 100.6±2.4%. We detected LTE4 (63.1±18.7 pg/mg creatinine, n=10) in healthy human urine. This method can be used to determine LTE4 in biological samples.  相似文献   

3.
For the first time, an LC–MS–MS method has been developed for the simultaneous analysis of buprenorphine (BUP), norbuprenorphine (NBUP), and buprenorphine–glucuronide (BUPG) in plasma. Analytes were isolated from plasma by C18 SPE and separated by gradient RP-LC. Electrospray ionization and MS–MS analyses were carried out using a PE-Sciex API-3000 tandem mass spectrometer. The m/z 644→m/z 468 transition was monitored for BUPG, whereas for BUP, BUP-d4, NBUP, and NBUP-d3 it was necessary to monitor the surviving parent ions in order to achieve the required sensitivity. The method exhibited good linearity from 0.1 to 50 ng/ml (r2≥0.998). Extraction recovery was higher than 77% for BUPG and higher than 88% for both BUP and NBUP. The LOQ was established at 0.1 ng/ml for the three analytes. The method was validated on plasma samples collected in a controlled intravenous and sublingual buprenorphine administration study. Norbuprenorphine–glucuronide was also tentatively detected in plasma by monitoring the m/z 590→m/z 414 transition.  相似文献   

4.
A simple multidimensional liquid chromatography system utilizing an isocratic pump and a HPLC system is described for the comprehensive proteomic analysis of complex peptide digest mixtures by coupled LC–LC–MS–MS techniques. A binary ion-exchange separation was achieved through the use of a strong cation-exchange column followed by a reversed-phase column for data-dependent LC–MS–MS analysis of the unbound analytes, and following salt elution (and concomitant column reequilibration), the bound analytes. Off-line validation of the platform showed near quantitative recovery of fractionated peptides and essentially complete ion-exchange partitioning. In comparative analyses of a highly complex peptide digest mixture a >40% increase in the number of peptide and protein identifications was achieved using this multidimensional platform compared to an unfractionated control.  相似文献   

5.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration.  相似文献   

6.
A liquid chromatography–electrospray ionization tandem mass spectrometric method was developed for the simultaneous determination of losartan and its major active metabolite, EXP-3174, in human plasma. The two analytes and the internal standard (DuP-167) were extracted from plasma under acidic conditions by using solid-phase extraction cartridges containing a sorbent of copolymer, poly(divinylbenzene-co-N-vinylpyrrolidone). The analytes were separated by LC equipped with a reversed-phase C18 column, and introduced into the mass spectrometer via the electrospray ion source with pneumatically-assisted nebulization. For LC–MS–MS samples, an isocratic mobile phase consisting of [0.1% triethylamine–0.1% acetic acid (pH 7.1)]–acetonitorile (65:35, v/v) was used, and the assay was monitored for the negative fragment ions of the analytes. The method demonstrated linearity from 1 to 1000 ng/ml for both losartan and EXP-3174. The limit of quantification for both compounds in plasma was 1 ng/ml. This assay method may be useful for the measurement of levels of the two compounds in clinical studies of losartan.  相似文献   

7.
We present fast LC–MS–MS analyses of multicomponent mixtures containing flavones, sulfonamides, benzodiazepines and tricyclic amines. Using a short microbore HPLC column with small particle size, five to eight compounds were partially resolved within 15 to 30 s. TurboIonSpray and atmospheric pressure chemical ionization interfaces were well suited to tolerate the higher eluent flow-rates of 1.2 to 2 ml/min. The methods were applied to biological sample matrices after clean-up using solid-phase or liquid–liquid extraction. Good precision and accuracy (average 8.9 and 97.7%, respectively) were achieved for the determination of tricyclic amines in human plasma. Benzodiazepines were determined in human urine with average precision of 9% and average accuracy of 95% for intra- and inter-assay. Detection limits in the low ng/ml range were obtained. An example for 240 injections per hour of demonstrated the feasibility of rapid LC–MS–MS analysis.  相似文献   

8.
A fast, robust and sensitive LC–MS–MS method for the determination of zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL) and β-zearalenol (β-ZOL) in beer samples is described. Sample preparation was performed by direct RP-18 solid-phase extraction of undiluted beer samples followed by selective determination of analytes by LC–MS–MS applying an atmospheric pressure chemical ionization (APCI) interface. Using the negative ion mode limits of determination of 0.03–0.06 μg l−1 beer and limits of quantification of 0.07–0.15 μg l−1 beer were achieved, which was distinctly more sensitive than in the positive ion mode. Twenty-three beer samples from different countries, produced from different grains and under different brewing conditions, were investigated by this method, but only in one sample could β-ZOL and ZON be detected. Independently of the type of beer, relative standard deviations between 2.1% and 3.3%, a linear working range of 0.15 μg l−1 to 500 μg l−1 beer and recovery rates around 100% could be achieved when zearalanone (ZAN) was used as internal standard.  相似文献   

9.
Morphine (MOR) is an opioid analgesic used for the treatment of moderate to severe pain. MOR is extensively metabolized to morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). A rapid and sensitive method that was able to reliably detect at least 0.5 ng/ml of MOR and 1.0 ng/ml of M6G was required to define their pharmacokinetic profiles. An LC–MS–MS method was developed in our laboratory to quantify all three analytes with the required sensitivity and a rapid turnaround time. A solid-phase extraction (SPE) was used to isolate MOR, M3G, M6G, and their corresponding deuterated internal standards from heparinized plasma. The extract was injected on a LC tandem mass spectrometer with a turbo ion-spray interface. Baseline chromatographic separation among MOR, M3G, and M6G peaks was achieved on a silica column with an aqueous organic mobile phase consisting of formic acid, water, and acetonitrile. The total chromatographic run time was 3 min per injection, with retention times of 1.5, 1.9 and 2.4 min for MOR, M6G, and M3G, respectively. Chromatographic separation of M3G and M6G from MOR was paramount in establishing the LC–MS–MS method selectivity because of fragmentation of M3G and M6G to MOR at the LC–MS interface. The standard curve range in plasma was 0.5–50 ng/ml for MOR, 1.0–100 ng/ml for M6G, and 10–1000 ng/ml for M3G. The inter-day precision and accuracy of the quality control (QC) samples were <7% relative standard deviation (RSD) and <6% relative error (R.E.) for MOR, <9% RSD and <5% R.E. for M6G, and <3% RSD and <6% R.E. for M3G. Analyte stability during sample processing and storage were established. Method ruggedness was demonstrated by the reproducible performance from multiple analysts using several LC–MS–MS systems to analyze over one thousand samples from clinical trials.  相似文献   

10.
We report here the development and validation of an LC–MS method for quantitation of loperamide (LOP) and its N-demethyl metabolite (DMLOP) in human plasma. O-Acetyl-loperamide (A-LOP) was synthesized by us for use as an internal standard in the assay. After addition of the internal standard, the compounds of interest were extracted with methyl tert.-butylether and separated by HPLC on a C18 reversed-phase column using an acetonitrile–water gradient containing 20 mM ammonium acetate. The three compounds were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in plasma. Analytes were quantitated using positive electrospray ionization in a triple quadrupole mass spectrometer operating in the MS–MS mode. Selected reaction monitoring was used to quantify LOP (m/z 477→266), DMLOP (m/z 463→252) and A-LOP (m/z 519→266) on ions formed by loss of the 4-(p-chlorophenyl)-4-hydroxy-piperidyl group upon low energy collision-induced dissociation. Calibration curves, which were linear over the range 1.04 to 41.7 pmol/ml (LOP) and 1.55 to 41.9 pmol/ml (DMLOP), were run contemporaneously with each batch of samples, along with low (4.2 pmol/ml), medium (16.7 pmol/ml) and high (33.4 pmol/ml) quality control samples. The lower limit of quantitation (LLQ) of LOP and DMLOP was about 0.25 pmol/ml in plasma. The extraction efficiency of LOP and DMLOP from human plasma was 72.3±1.50% (range: 70.7–73.7%) and 79.4±12.8% (64.9–88.8%), respectively. The intra- and inter-assay variability of LOP and DMLOP ranged from 2.1 to 14.5% for the low, medium and high quality control samples. The method has been used successfully to study loperamide pharmacokinetics in adult humans.  相似文献   

11.
Different hyphenated liquid chromatographic (LC) and mass spectrometric (MS) techniques were investigated in order to set-up a method for the fast, direct analysis of betamethasone in hydrolysed and non-hydrolysed urine using large-volume sample injection. After the optimisation of the LC parameters using a traditional UV detector and of the thermospray and mass spectrometric parameters by flow injection, urine samples (0.5 ml) were submitted to analysis by either LC combined with tandem mass spectrometry (MS–MS), coupled-column LC (LC–LC) combined with single quadrupole MS, and LC–LC–MS–MS. Both the three-step configurations (LC–MS–MS and LC–LC–MS) did not provide satisfactory results: loss of sensitivity was noted in the case of LC–MS–MS (likely due to reduced efficiency in the ionisation of betamethasone in the thermospray owing to the presence of large amounts of matrix interference), while in the case of LC–LC–MS a high chemical noise resulting in insufficient selectivity of detection was observed. On the contrary, LC–LC–MS–MS analysis proved to meet the demand of high speed of analysis (sample throughput, 4.5 h−1), selectivity, and sensitivity (LOQ, 1 ng/ml; LOD, 0.2 ng/ml). Notwithstanding the complex analytical system adopted, the developed procedure was manageable and very robust, provided that at the beginning of each analytical session the performance of the system was controlled by checking the retention time of the analytes on the first analytical column with UV detection and by optimising vaporiser temperature of the thermospray by flow injection.  相似文献   

12.
The characteristics of the mass spectra of vitamin D3 related compounds were investigated by GC–MS and LC–MS using 22-oxacalcitriol (OCT), an analog of 1,25-dihydroxyvitamin D3, and related compounds. Fragmentation during GC–MS (electron impact ionization) of TMS-derivatives of OCT and the postulated metabolites gave useful structural information concerning the vitamin D3-skeleton and its side-chain, especially with respect to the oxidation positions of metabolites. In contrast, few fragment ions were observed in LC–MS (atmospheric pressure chemical ionization), showing that LC–MS gave poor structural information, except for molecular mass. However, when comparing the signal-to-noise ratio (S/N) observed during GC–MS and LC–MS analysis for OCT in plasma extracts, the S/N in LC–MS was over ten-times greater than in GC–MS, possibly due to the low recovery on derivatization and thermal-isomerization in GC–MS. Furthermore, both the GC–MS and the LC–MS allowed the analysis of many postulated metabolites in a single injection without any prior isolation of target metabolites from biological fluids by LC. These results suggest that GC–MS and LC–MS analysis for vitamin D3 related compounds such as OCT each have unique and distinct advantages. Therefore, the complementary use of both techniques enables the rapid and detailed characterization of vitamin D3 related compounds.  相似文献   

13.
A selected-ion monitoring (SIM) determination of serum lycopene, α-carotene and β-carotene by an atmospheric pressure chemical ionization mass spectrometry (APCI–MS) was developed. A large amount of serum cholesterols disturbed the SIM determination of carotenoids by contaminating the segment of interface with the LC–MS. Therefore, separation of carotenoids from the cholesterols was performed using a mixed solution of methanol and acetonitrile (70:30) as the mobile phase on a C18 column of mightsil ODS-5 (75 mm×4.6 mm I.D.). The SIM determination was carried out by introducing only the peak portions of carotenoids and I.S. (squalene) by means of an auto switching valve. In the positive mode of APCI–MS, lycopene, α-carotene and β-carotene were monitored at m/z 537 and I.S. was monitored at m/z 411. This method was linear for all analytes in the range of 15–150 ng for lycopene, 7–70 ng for α-carotene and 25–50 ng for β-carotene. The detection limit of LC–APCI–MS-SIM for carotenoids was about 3 ng per 1 ml of serum (S/N=3). The repeatabilities, expressed as C.V.s, were 10%, 8.4% and 5.3% for lycopene, α-carotene and β-carotene, respectively. The intermediate precisions, expressed as C.V.s, were 11. 2%, 8.8% and 6.5% for lycopene, α-carotene and β-carotene, respectively.  相似文献   

14.
Use of silica stationary phase and aqueous–organic mobile phases could significantly enhance LC–MS–MS method sensitivity. The LC conditions were compatible with MS detection. Analytes with basic functional groups were eluted with acidic mobile phases and detected by MS in the positive ion mode. Analytes with acid functional groups were eluted with mobile phases at neutral pH and detected by MS in the negative ion mode. Analytes poorly retained on reversed-phase columns showed good retention on silica columns. Compared with reversed-phase LC–MS–MS, 5–8-fold sensitivity increases were observed for basic polar ionic compounds when using silica columns and aqueous–organic mobile phase. Up to a 20-fold sensitivity increase was observed for acidic polar ionic compounds. Silica columns and aqueous–organic mobile phases were used for assaying nicotine, cotinine, and albuterol in biological fluids.  相似文献   

15.
A column-switching liquid chromatography–electrospray ionization-tandem mass spectrometric (LC–ESI-MS–MS) method was developed for the direct analysis of entacapone glucuronide in plasma. The plasma samples (5 μl) were injected onto a C18-alkyl-diol silica (ADS) column and the matrix compounds were washed to waste with a mixture of 20 mM ammonium acetate solution at pH 4.0–acetonitrile (97:3). The retained analyte fraction containing (E)- and (Z)-isomers of glucuronides of entacapone and tolcapone glucuronide (internal standard) was backflushed to the analytical C18 column, with a mixture of 20 mM ammonium acetate–acetonitrile (85:15) for the final separation at pH 7.0. The eluate was directed to the mass spectrometer after splitting (1:100). The mass spectrometer was operated in the negative ion mode and the deprotonated molecules [M−H] were chosen as precursor ions for the analytes and internal standard. Collisionally induced dissociation of [M−H] in MS–MS resulted in loss of the neutral glucuronide moiety and in the appearance of intensive negatively charged aglycones [M−H−Glu], which were chosen as the product ions for single reaction monitoring. Quantitative studies showed a wide dynamic range (0.0025–100 μg/ml) with correlation coefficients better than 0.995. The method was repeatable within-day (relative standard deviation, RSD<7%) and between-day (RSD<14%) and the recovery (78–103%) was better than with the traditional, laborious pretreatment method. The use of tandem mass spectrometry permitted low limits of detection (1 ng/ml of entacapone glucuronide). The method was applied for the quantitation of (E)- and (Z)-isomers of entacapone glucuronide in plasma of rats used in absorption studies.  相似文献   

16.
An HPLC–MS–MS method for the quantitative analysis of flunitrazepam in human serum was established. The method features a very simple liquid–liquid extraction, the use of a standard 4-mm HPLC column, isocratic elution using a buffer-free solvent, short retention times in connection with good peak resolution and the sensitivity and selectivity of an ion trap MS–MS detector. The procedure enables unambiguous identification of analytes by their product ion spectra, as well as sensitive quantitation (limit of quantitation for flunitrazepam=0.5 ng/ml). This feature was used for the confirmation of HPLC–UV results for nitrazepam.  相似文献   

17.
An LC–MS–MS method for the analysis of the neuraminidase inhibitor, zanamivir, in human serum is described. Zanamivir was extracted from protein precipitated human serum samples using Isolute SCX solid-phase extraction cartridges and analysed using reversed-phase chromatography with TurboIonSpray atmospheric pressure ionisation followed by mass spectrometric detection. The method uses a stable isotope internal standard, is highly specific and sensitive for a compound of this type and has been used for the analysis of human serum and urine samples from clinical studies. The method was extended to the analysis of serum and plasma samples from pre-clinical studies involving the rat, ferret and cell culture media. The method has been shown to be robust and valid over a concentration range of 10–5000 ng/ml using a 0.2-ml sample volume. The main advantages of this method compared to earlier procedures are primarily specificity, sensitivity, ease of sample preparation, small sample volume and short analysis time (ca. 5 min).  相似文献   

18.
An ion-paring HPLC–MS–MS method with positive ion mode electrospray ionization has been developed to simultaneously quantify Ziagen, carbovir monophosphate, carbovir diphosphate and carbovir triphosphate. N′,N′-Dimethylhexylamine was used as the ion-pairing agent. The presence of this ion-pairing agent allowed the retention and separation of the four compounds on a reversed-phase HPLC column as well as the detection of the nucleotides with positive ion mode electrospray ionization. The limits of detection were found to be better than 25 nM for all the analytes. Calibration curves of the analytes showed excellent linearity over the range of 25 nM to 5 μM. The relative standard deviations and accuracies for replicate analyses of quality control samples were less than 15%. The method has been successfully applied to the analysis of these compounds in human liver cells treated with Ziagen.  相似文献   

19.
This work presents the development and the validation of an LC–MS–MS method with atmospheric pressure chemical ionization for the quantitative determination of levamisole, an anthelmintic for veterinary use, in porcine tissue samples. A liquid–liquid back extraction procedure using hexane–isoamylalcohol (95:5, v/v) as extraction solvent was followed by a solid-phase extraction procedure using an SCX column to clean up the tissue samples. Methyllevamisole was used as the internal standard. Chromatographic separation was achieved on a LiChrospher® 60 RP-select B (5 μm) column using a mixture of 0.1 M ammonium acetate in water and acetonitrile as the mobile phase. The mass spectrometer was operated in MS–MS full scanning mode. The method was validated for the analysis of various porcine tissues: muscle, kidney, liver, fat and skin plus fat, according to the requirements defined by the European Community. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r>0.99 and goodness of fit <10%). Limits of quantification of 5.0 ng/g were obtained for the analysis of levamisole in muscle, kidney, fat and skin plus fat tissues, and of 50.0 ng/g for liver analysis, which correspond in all cases to half the MRLs (maximum residue limits). Limits of detection ranged between 2 and 4 ng/g tissue. The within-day and between-day precisions (RSD, %) and the results for accuracy fell within the ranges specified. The method has been successfully used for the quantitative determination of levamisole in tissue samples from pigs medicated via drinking water. Moreover the product ion spectra of the levamisole peak in spiked and incurred tissue samples were in close agreement (based on ion ratio measurements) with those of standard solutions, indicating the worthiness of the described method for pure qualitative purposes.  相似文献   

20.
Nodularins are cyanobacterial hepatotoxins, which may cause intoxication at very low exposure levels. The nodularin-producing cyanobacterium Nodularia spumigena usually forms massive blooms in much of the Baltic Sea during the summer season. Breast feathers and liver samples from common eider (Somateria mollissima) were analysed for nodularins by liquid chromatography–mass spectrometry (LC–MS) and enzyme-linked immunosorbent assay (ELISA). Fifteen eiders from the western Gulf of Finland were caught by hunters between June and September 2005. Blue mussels (Mytilus edulis), a dietary component of the birds, were also obtained by diving near the same marine area and time as the collection of the ducks. Eider breast feathers contained 6–52 μg nodularin-R (Nod-R)/kg dry weight (dw) by ELISA, and 8–43 μg Nod-R/kg dw by LC–MS. No Nodularia filaments were adhered to feather samples according to light microscopy assessment. Liver samples from the same individuals contained Nod-R between 3 and 48 μg/kg dw by LC–MS. Mussel samples from the area contained Nod-R at concentrations of 12–80 μg/kg dw by LC–MS. Analysis of bird feathers offers a facile and non-invasive means of assessing the exposure of birds to nodularins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号