首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Clinical reports suggest that large bone defects could be effectively restored by allograft bone transplantation, where allograft bone selection acts an important role. Besides, there is a huge demand for developing the automatic allograft bone selection methods, as the automatic methods could greatly improve the management efficiency of the large bone banks. Although several automatic methods have been presented to select the most suitable allograft bone from the massive allograft bone bank, these methods still suffer from inaccuracy. In this paper, we propose an effective allograft bone selection method without using the contralateral bones. Firstly, the allograft bone is globally aligned to the recipient bone by surface registration. Then, the global alignment is further refined through band registration. The band, defined as the recipient points within the lifted and lowered cutting planes, could involve more local structure of the defected segment. Therefore, our method could achieve robust alignment and high registration accuracy of the allograft and recipient. Moreover, the existing contour method and surface method could be unified into one framework under our method by adjusting the lift and lower distances of the cutting planes. Finally, our method has been validated on the database of distal femurs. The experimental results indicate that our method outperforms the surface method and contour method.  相似文献   

2.
The use of massive bone allografts is increasing year by year and selection method remains unchanged. Superposition of patient’s radiograph over allograft image and comparison of distances is the gold standard. Experiment was led to test selection procedure of a major european tissue bank. Four observers were asked to select an allograft for 10 fictive recipients. Nine allografts were provided. To simulate a perfect allograft, recipient himself was inserted in the pool of allografts (trap graft). The 10 potential bone transplants were classified in four categories (from adequate to unacceptable). In addition, observers were asked to choose the three best grafts for a given recipient. Quadratic kappa measuring agreement on classification between two observers ranged between 0.74 (substantial) and 0.47 (moderate). Trap graft was quoted by observers as adequate four times (10%) and was cited eight times (20%) among the three best matching allografts. None of the observers discovered that recipient was among allograft panel. This study demonstrates that current selection method is inaccurate for hemipelvic allograft selection. New methods should be developed and tested to assist tissue banks in bone allograft selection.  相似文献   

3.
Migration of fibroblasts into heart valve leaflet tissue in vitro   总被引:1,自引:0,他引:1  
Heart valve allografts are widely used for surgical treatment of the heart. In recent years a new field of research has emerged dealing with allograft modification by cells of recipient by means of tissue engineering. This method involves culturing fibroblasts and endothelial cells, using recipient tissue, followed by introduction of the fibroblasts into tissues of allograft and coating its surface by the endothelial cells. This modification is expected to ensure the structural maintenance of implanted tissues and to reduce its thrombogenecity. This procedure may promote the allograft adhering to the recipient tissues, thus prolonging the terms of the valve normal functioning after implantations. For this purpose, methods of luminescent microscopy are suggested using double staining of tissue with fluorescent dyes Hoechst 33,342 and ethidium bromide, or with fluorescein diacetate and ethidium bromide. Experimental results are presented indicative of fibroblast migration from the surface to the human heart valve leaflets.  相似文献   

4.
Magnetic resonance imaging has revolutionized the detection of structural abnormalities in patients with epilepsy. However, many focal abnormalities remain undetected in routine visual inspection. Here we use an automated, surface-based method for quantifying morphometric features related to epileptogenic cortical malformations to detect abnormal cortical thickness and blurred gray-white matter boundaries. Using MRI morphometry at 3T with surface-based spherical averaging techniques that precisely align anatomical structures between individual brains, we compared single patients with known lesions to a large normal control group to detect clusters of abnormal cortical thickness, gray-white matter contrast, local gyrification, sulcal depth, jacobian distance and curvature. To assess the effects of threshold and smoothing on detection sensitivity and specificity, we systematically varied these parameters with different thresholds and smoothing levels. To test the effectiveness of the technique to detect lesions of epileptogenic character, we compared the detected structural abnormalities to expert-tracings, intracranial EEG, pathology and surgical outcome in a homogeneous patient sample. With optimal parameters and by combining thickness and GWC, the surface-based detection method identified 92% of cortical lesions (sensitivity) with few false positives (96% specificity), successfully discriminating patients from controls 94% of the time. The detected structural abnormalities were related to the seizure onset zones, abnormal histology and positive outcome in all surgical patients. However, the method failed to adequately describe lesion extent in most cases. Automated surface-based MRI morphometry, if used with optimized parameters, may be a valuable additional clinical tool to improve the detection of subtle or previously occult malformations and therefore could improve identification of patients with intractable focal epilepsy who may benefit from surgery.  相似文献   

5.
The rotational cutting method has been used in needle biopsy technologies to sample tough tissues, such as calcifications in the breast. The rotational motion of the needle introduces shear forces to the cutting surface such that the cutting force in the axial direction is reduced. As a result, tissue samples with large volume and better quality can be obtained. In order to comprehensively understand the effect of the needle rotation to the axial cutting force under a wide range of the needle insertion speed, this paper demonstrates a computational approach that incorporates the surface-based cohesive behavior to simulate a rotating needle cutting soft tissue. The computational model is validated by comparing with a cutting test dataset reported in the literature. The validated model is then used to generate response surfaces of the axial cutting force and torque in a large parameter space of needle rotation and insertion speeds. The results provide guidelines for selecting optimal speed configurations under different design situations.  相似文献   

6.
It is known that experimental vascularized bone allografts are subject to host rejection. To be useful clinically, this rejection response would need to be controlled. Cyclosporin is a potent immunosuppressant whose precise role in vascularized bone allograft transplantation has not been established. Using a proven reliable vascularized knee allograft model in inbred rats, cyclosporin was used postoperatively both continuously and short term (14 days after transplant) at 10 mg/kg per day as recipient treatment. Across a strong histocompatibility barrier, continuous cyclosporin was required for long-term graft survival. Short-term therapy delayed rejection for 4 to 6 weeks. However, across a weak histocompatibility barrier, short-term therapy was as effective as continuous therapy in achieving long-term graft survival. The implication is that a limited course of cyclosporin may be clinically successful in sustaining vascularized bone allograft survival, provided the genetic disparity between graft and host has been minimized by genetic matching techniques.  相似文献   

7.
The presence of donor-specific alloantibodies (DSAs) against the MICA antigen results in high risk for antibody-mediated rejection (AMR) of a transplanted kidney, especially in patients receiving a re-transplant. We describe the incidence of acute C4d+ AMR in a patient who had received a first kidney transplant with a zero HLA antigen mismatch. Retrospective analysis of post-transplant T and B cell crossmatches were negative, but a high level of MICA alloantibody was detected in sera collected both before and after transplant. The DSA against the first allograft mismatched MICA*018 was in the recipient. Flow cytometry and cytotoxicity tests with five samples of freshly isolated human umbilical vein endothelial cells demonstrated the alloantibody nature of patient’s MICA-DSA. Prior to the second transplant, a MICA virtual crossmatch and T and B cell crossmatches were used to identify a suitable donor. The patient received a second kidney transplant, and allograft was functioning well at one-year follow-up. Our study indicates that MICA virtual crossmatch is important in selection of a kidney donor if the recipient has been sensitized with MICA antigens.  相似文献   

8.
The anti-TNP IgM plaque-forming cells (PFC) were generated in the spleen and bone marrow of non-immunodeficient normal mice after intraperitoneal administration of TNP-LPS. Irradiation of normal mice while shielding bone marrow completely abrogated the generation of bone marrow PFC, indicating that they are derived from extramedullary sites. The bone marrow PFC, response to TNP-LPS was low in X-linked immunodeficient CBA/N strain mice, while the spleen response was comparable to that seen in the normal mice. To further study the basis of the deficient bone marrow PFC response in CBA/N mice, spleen cells were adoptively transferred to irradiated syngeneic mice stimulated with TNP-LPS. While spleen cells from normal mice generated high numbers of PFC in recipient bone marrow and spleen, those from CBA/N strain mice could not generate bone marrow PFC. This result was obtained regardless of whether normal or CBA/N recipients were used. These results indicate that TNP-LPS administration normally results in the migration of B lymphocytes from the periphery into the bone marrow and that B cells from immunodeficient CBA/N strain mice bear an inherent defect in this migratory function. This migratory defect was shown to be X-linked, as are the other previously reported B cell defects in this inbred mouse strain. The possible relationship between this migratory defect and the maturational defects of B cell lineage as reported previously in CBA/N strain mice is discussed.  相似文献   

9.
Suitability of the scapular flap for reconstructions of the foot   总被引:3,自引:0,他引:3  
Eighteen patients with mainly a traumatic soft-tissue defect of the foot underwent reconstruction with a microvascular free scapular flap. Of the 17 successful transfers, 13 were to the weight-bearing parts of the foot. The stability and contour of the flaps were assessed after an average follow-up time of 3 years (range 1 to 5 years). The thicknesses of the scapular donor site and flap and the recipient site were measured by an ultrasound technique. The resistance of the flap to shear was measured with a dynamometer. The ultrasound measurements aided in refining our operative technique. In early cases, the flap thickness after transfer could be more than double what it was in the donor area. With proper tightening, the thickness could be reduced, with improvement in contour but no increase in soft-tissue stability or shear resistance of the flap. Without proper tightening, the scapular flap tended to be redundant when transferred to the foot. For good results, the patient should be lean, since the optimal thickness of the scapular donor site was less than 6 mm and the maximum thickness should not exceed 8 to 10 mm. The differences in shear resistance between the flaps were not associated with the soft-tissue stability of the reconstruction. The relative laxity of the flap on the plantar surface was found by several patients to be subjectively unpleasant. Although good contour could be achieved when covering the plantar heel, the tendency of the flap to develop abrasions and superficial breakdowns made it unsatisfactory for covering this area.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Osteoarticular allograft is one possible treatment in wide surgical resections with large defects. Performing best osteoarticular allograft selection is of great relevance for optimal exploitation of the bone databank, good surgery outcome and patient’s recovery. Current approaches are, however, very time consuming hindering these points in practice. We present a validation study of a software able to perform automatic bone measurements used to automatically assess the distal femur sizes across a databank. 170 distal femur surfaces were reconstructed from CT data and measured manually using a size measure protocol taking into account the transepicondyler distance (A), anterior-posterior distance in medial condyle (B) and anterior-posterior distance in lateral condyle (C). Intra- and inter-observer studies were conducted and regarded as ground truth measurements. Manual and automatic measures were compared. For the automatic measurements, the correlation coefficients between observer one and automatic method, were of 0.99 for A measure and 0.96 for B and C measures. The average time needed to perform the measurements was of 16 h for both manual measurements, and of 3 min for the automatic method. Results demonstrate the high reliability and, most importantly, high repeatability of the proposed approach, and considerable speed-up on the planning.  相似文献   

11.
An automated procedure that refines the nuclear contour of a previously segmented nucleus is described. The algorithm makes use of intensity information, edge magnitude information and both object and edge connectivity information. This automated procedure generates a closed contour precisely along the edge of the nucleus. The procedure was tested on a database of 3,680 red-green-blue images of thionin-SO2 and orange II-stained cervical cells obtained from normal and dysplastic samples. When used in conjunction with a simple threshold selection algorithm and an artifact removal routine, this edge relocation algorithm resulted in the correct segmentation of over 98% of the nuclei. Only 63 (1.7%) of all nuclei were incorrectly segmented.  相似文献   

12.
A heterotopic subcutaneous model for experimental vascularized bone allograft transplantation has been presented. This model uses genetically defined rats and allows serial assessment of graft viability. The reliability of this model has been proven by successful isograft transplantation. This model was used to study the effect of matching at the major histocompatibility complex on vascularized bone allograft survival. Whereas grafts transplanted across a minor histocompatibility barrier survived until sacrifice, grafts transplanted across a major histocompatibility barrier were victims of an acute rejection process. This study, therefore, showed genetic disparity to be a critical determinant of vascularized bone allograft survival. It indicates that primary vascularized bone allografts are as susceptible to rejection as heart and kidney allografts. For these reasons, it can be anticipated that genetic matching will be important in clinical vascularized bone allograft transplantation. The model used in this study should be useful for obtaining further fundamental immunologic information concerning vascularized bone allograft transplantation.  相似文献   

13.
Head and neck cancer is the sixth most common cancer in the world and one of the most lethal cancers. Microsatellite instability is an important characteristic of tumor cells and is observed both in presence and absence of mismatch repair gene mutations. The importance of microsatellite instability in head and neck cancer is not well established due to the lack of a consensus panel and selection of different markers, criteria and methodological variances. The main objective of this study was to investigate the performance of a consensus panel of microsatellite repeats by automated fragment analysis. Matched tumor and normal tissue samples from 99 patients were analyzed using five mononucleotide markers. Following PCR the amplified fragments were analyzed by capillary electrophoresis on an ABI 310 genetic analyzer. Microsatellite instability was observed in 26 patients. In 17 patients instability was detected at multiple loci. NR21 and BAT25 were the most frequently altered targets. These two mononucleotide markers could detect all samples displaying high-instability. In this study we describe a standardized fluorescent multiplex PCR combined with computerized analysis, which allows rapid and accurate analysis of a high number of samples and obviates the need to compare tumors with matching normal tissue.  相似文献   

14.
Good segmentation of the outer bone cortex from medical images is a prerequisite for applications in the field of finite element analysis, surgical planning environments and personalised, case dependent, bone reconstruction. However, current segmentation procedures are often unsatisfactory. This study presents an automated filter procedure to generate a set of adapted contours from which a surface mesh can be deduced directly. The degree of interaction is user determined. The bone contours are extracted from the patients CT data by quick grey value segmentation. An extended filter procedure then only retains contour information representing the outer cortex as more specific internal loops and shape irregularities are removed, tailoring the image for the above-mentioned applications. The developed medical image based design methodology to convert contour sets of multiple bone types, from tibia tumour to neurocranium, is reported and discussed.  相似文献   

15.
An improved surface-based method for DNA computation   总被引:36,自引:0,他引:36  
Wu H 《Bio Systems》2001,59(1):1-5
DNA computing is a novel method for solving a class of intractable computational problems, in which the computing time can grow exponentially with problem size. Up to now, many accomplishments have been achieved to improve its performance and increase its reliability, among which a surface-based method is an efficient candidate. In this paper, the surface-based approach proposed by Liu, Q., Wang, L., Frutos, A.G., Condon, A.E., Corn, R.M., and Smith, L.M., 2000, DNA computing on surfaces. Nature 403, 175-179 is analyzed and an improved surface-based method for DNA computation (i.e. the hybrid DNA/optical computing method) is proposed. Compared with Liu et al.'s approach, our method has some significant advantages such as low cost, short operating time, reusable surface and simple experimental steps. Moreover, the concept of combining easily patterned DNA computing steps with equally parallel, but generally uniform and not easily patterned optical computing steps is an important new direction.  相似文献   

16.
For several decades, a dose of 25 kGy of gamma irradiation has been recommended for terminal sterilization of medical products, including bone allografts. Practically, the application of a given gamma dose varies from tissue bank to tissue bank. While many banks use 25 kGy, some have adopted a higher dose, while some choose lower doses, and others do not use irradiation for terminal sterilization. A revolution in quality control in the tissue banking industry has occurred in line with development of quality assurance standards. These have resulted in significant reductions in the risk of contamination by microorganisms of final graft products. In light of these developments, there is sufficient rationale to re-establish a new standard dose, sufficient enough to sterilize allograft bone, while minimizing the adverse effects of gamma radiation on tissue properties. Using valid modifications, several authors have applied ISO standards to establish a radiation dose for bone allografts that is specific to systems employed in bone banking. These standards, and their verification, suggest that the actual dose could be significantly reduced from 25 kGy, while maintaining a valid sterility assurance level (SAL) of 10−6. The current paper reviews the methods that have been used to develop radiation doses for terminal sterilization of medical products, and the current trend for selection of a specific dose for tissue banks.  相似文献   

17.
Trabecular alignment theory has been used to quantify Wolff's Law of bone remodeling. A three-dimensional finite element scheme was developed to analyze the bone remodeling phenomenon. The mathematical model proposed by Mullender et al. and later modified by Smith et al. was adopted to simulate the surface-based trabecular resorption and formation processes. Enhancements incorporated into the previous model include: mapping into three-dimensions, controlling the remodeling signal's passage through marrow, controlling the finite distance the signal may pass through the bone matrix, and including non-bone material in the finite element model. After the model is explained and thoroughly studied, three-dimensional implant surface geometries are simulated.  相似文献   

18.
Bone allograft is widely used to treat large bone defects or complex fractures. However, processing methods can significantly compromise allograft osteogenic activity. Adjuvants that can restore the osteogenic activity of processed allograft should improve clinical outcomes. In this study, zinc was tested as an adjuvant to increase the osteogenic activity of human allograft in a Rag2 null rat femoral defect model. Femoral defects were treated with human demineralized bone matrix (DBM) mixed with carboxy methyl cellulose containing ZnCl2 (0, 75, 150, 300 µg) or Zn stearate (347 µg). Rat femur defects treated with DBM-ZnCl2 (75 µg) and DBM-Zn stearate (347 µg) showed increased calcified tissue in the defect site compared to DBM alone. Radiograph scoring and µCT (microcomputed tomography) analysis showed an increased amount of bone formation at the defects treated with DBM-Zn stearate. Use of zinc as an adjuvant was also tested using human cancellous bone chips. The bone chips were soaked in ZnCl2 solutions before being added to defect sites. Zn adsorbed onto the chips in a time- and concentration-dependent manner. Rat femur defects treated with Zn-bound bone chips had more new bone in the defects based on µCT and histomorphometric analyses. The results indicate that zinc supplementation of human bone allograft improves allograft osteogenic activity in the rat femur defect model.  相似文献   

19.
Fan Y  Fan Y  Li Z  Lv C  Zhang B 《PloS one》2012,7(3):e32926
Bone shape is an important factor to determine the bone's structural function. For the asymmetrically shaped and anisotropically distributed bone in vivo, a surface mapping method is proposed on the bases of its geometric transformation invariance and its uniqueness of the principal axes of inertia. Using spiral CT scanning, we can make precise measurements to bone in vivo. The coordinate transformations lead to the principal axes of inertia, with which the prime meridian and the contour can be set. Methods such as tomographic reconstruction and boundary development are employed so that the surface of bone in vivo can be mapped. Experimental results show that the surface mapping method can reflect the shape features and help study the surface changes of bone in vivo. This method can be applied to research into the surface characteristics and changes of organ, tissue or cell whenever its digitalized surface is obtained.  相似文献   

20.
Infectious disease transmission through the use of human donor allografts can be a catastrophic complication in an otherwise straightforward surgical procedure. The use of bone allograft in reconstructive orthopedic surgeries is increasing, yet severe complications, including death, can result if the transplanted tissues transmit a communicable disease to the tissue recipient. The BioCleanse((R)) tissue sterilization process is a fully automated, low-temperature chemical sterilization process that renders allograft tissue sterile. The purpose of this study was to evaluate the effect of a chemical tissue sterilization process on the mechanical strength of cortical bone allografts prior to implantation. Cylindrical cortical bone specimens were harvested from seven human cadaver donors and treated either by: chemical sterilization alone; chemical sterilization and terminal sterilization by gamma irradiation; chemical sterilization, lyophilization, terminal sterilization by STERRAD and rehydration; or untreated. The specimens were tested to failure in axial compression, diametral compression, shear, or bending. There were no significant differences in ultimate stress, strain, or fracture energy between the chemically sterilized and control groups in any of the testing modes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号