首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
R(−)-Ondansetron and S(+)-ondansetron in human serum were resolved and quantified using a stereospecific HPLC method. Each enantiomer and the internal standard prazosin were isolated from serum using a solid-phase extraction procedure on a cyanopropyl column. Recoveries of 97, 96 and 88% were obtained for the R(−)-enantiomer, the S(+)-enantiomer, and the internal standard, respectively. A cellulose-based chiral analytical column (Chiralcel OD) was used with a mobile phase consisting of hexane—95% ethanol—2-propanol—acetonitrile (65:25:10:1, v/v). Linear calibration curves were obtained for each enantiomer in serum in the concentration range 10–200 ng/ml. The limit of quantitation of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using UV detection at 216 nm was 2.5 ng/ml (signal-to-noise ratio of 3).  相似文献   

2.
A stereoselective high-performance liquid chromatography assay method was developed for the quantitation of R-(+)- and S_-(−)-mepivacaine in human serum. The assay uses a Pirkle brush-type. ((S)-tert.-leucine, (R)-(-naphthyl)ethylamine stationary phase (Sumichiral OA-4700, 250×4 mm I.D.) at ambient temperature with a mobile phase of hexane-ethylenedichloride-absolutte methanol (85:10:5, v/v) for the separation of R-(+) and (S)-(−)-mepivacaine. The eluents were monitored using UV detection at 220 nm. Isolation of the analytes from serum was performed using a 1-ml C18 solid-phase extraction cartridge with high recovery and selectivity. The detection limits were 100 ng/ml for each enantiomer and the limits of quantitation were 150 ng/ml for both enantiomers. Linear calibration curves in the 150–2400 ng/ml range showed good correlation coefficients (r>0.9994, N=3). Precision and accuracy of the method were within 2.1–5.3 and 2.0–3.6%, respectively, for (R)-(+)-mepivacaine and 2.7–5.7% and 1.7–4.2%, respectively, for S-(−)-mepivacaine.  相似文献   

3.
A direct chiral-phase high-performance liquid chromatographic method for measuring the ratio of S-warfarin/R-warfarin in patient plasma is described. Plasma samples are first extracted using solid-phase C18 extraction columns, and the concentrated extracts analyzed using an (R,R) Whelk-O 1 column with a mobile phase of 0.5% glacial acetic acid in acetonitrile. The resulting chromatography provides baseline resolution of the warfarin enantiomers and internal standard (racemic ethylwarfarin), and is free from interference from other plasma components. Calibration curves were linear (mean r2 of 0.999 for both enantiomers) over the concentration range 0.25–1.5 μg/ml. The intra-day and inter-day coefficients of variation for analysis of plasma spiked with 0.33 μg/ml S-warfarin and 0.67 μg/ml R-warfarin (S/R=0.5:1) was less than 7% for each enantiomer, with an accuracy of more than 93%. Plasma extracts from thirty-one patients homozygous for wild-type CYP2C9*1 provided an S/R ratio of 0.51±0.15. Two warfarin patients homozygous for the mutant CYP2C9*2 and CYP2C9*3 alleles exhibited elevated S/R ratios relative to the mean for individuals homozygous for the wild-type CYP2C9*1 allele. This method is suitable for population studies aimed at establishing the effect of polymorphic expression of CYP2C9 alleles on S-warfarin elimination in humans.  相似文献   

4.
A stereoselective high-performance liquid chromatographic (HPLC) method is described for the selective and sensitive quantitation in human plasma of R-(+)- and S-(−)-enantiomers of remoxipride. Remoxipride was extracted from basified plasma into hexane-methyl-tert.-butyl ether (20:80, v/v), washed with sodium hydroxide (1.0 M), then back-extracted into phosphoric acid (0.1 M). A structural analog of remoxipride was used as an internal standard. The sample extracts were chromatographed using a silica-based derivatized cellulose chiral column, Chiralcel OD-R, and a reversed-phase eluent containing 30–32% acetonitrile in 0.1 M potassium hexafluorophosphate. Ultraviolet (UV) absorbance detection was performed at 214 nm. Using 0.5-ml plasma aliquots, the method was validated in the concentration range 0.02-2.0 μg/ml and was applied in the investigation of systemic inversion of remoxipride enantiomers in man.  相似文献   

5.
A sensitive HPLC method for the quantification of praziquantel enantiomers in human serum is described. The method involves the use of a novel disc solid-phase extraction for sample clean-up prior to HPLC analysis and is also free of interference from trans-4-hydroxypraziquantel, the major metabolite of praziquantel. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OJ-R) under isocratic conditions using a mobile phase consisting of 0.1 M sodium perchlorate–acetonitrile (66:34, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R-(−)- and S-(+)-praziquantel enantiomers were in the range of 84–89% at 50–500 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 3–8% and 1–8% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.2–5% and 0.3–8% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 10–600 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 5 ng/ml (S/N=2).  相似文献   

6.
An HPLC method for the quantification of ketoprofen enantiomers in human plasma is described. Following extraction with a disposable C18 solid-phase extraction column, separation of ketoprofen enantiomers and I.S. (3,4-dimethoxy benzoic acid) was achieved using a chiral column [Chirex 3005; (R)-1-naphthylglycine 3,5-dinitrobenzoic acid] with the mobile phase, 0.02 M ammonium acetate in methanol, set at a flow-rate of 1.2 ml/min. Baseline separation of ketoprofen enantiomers and I.S., free from interferences, was achieved in less than 20 min. The calibration curves (n = 14) were linear over the concentration range of 0.16 to 5.00 μg/ml per enantiomer [mean r2 of 0.999 for both enantiomers, root mean square error were 0.015 for R(−) and 0.013 for S(+)]. The inter-day coefficient of variation for duplicate analysis of spiked samples was less than 7% and the accuracy was more than 93% over the concentration range of 0.2 to 4.0 μg/ml for individual enantiomer using 1 ml of plasma sample. This method has been applied to a pharmacokinetic study from healthy human volunteers following the administration of a ketoprofen extended release product (200 mg). This method is simple, fast and should find wide application in monitoring pharmacokinetic studies of ketoprofen.  相似文献   

7.
A simple, rapid, sensitive and selective method has been developed for the stereospecific determination of verapamil and its metabolite, norverapamil in urine. For sample preparation we utilized a membrane-based solid-phase extraction (SPE) disk consisting of a thin, particle-loaded membrane inserted in a plastic syringe-like barrel. The particles, which may be C8 or C18 bonded phase (C8 in this work), are embedded within a matrix of PTFE (Teflon) fibrils. Overall analyte recoveries were above 85%, even at low concentration of 3.0 ng/ml with reproducibilities (C.V. values) below 13.1%. This method of extraction has the advantage of speed and considerable reduction in solvent volumes compared to conventional SPE and solvent extraction. The separation of all the enantiomers was achieved using a single chiral stationary phase column, the cellulose-based reversed-phase, Chiralcel OD-R. Analyte concentrations of less than 3.0 ng/ml could be quantitated with C.V. values below 14%. Calibration curves were linear in the range 2.5–300 ng/ml. Intra-day and inter-day reproducibilities were 10.5–14.2% at 3 ng/ml, 4.8–9.3% at 138.5 ng/ml and 7.8–10.1% at 280 ng/ml level, respectively, for all the enantiomers.  相似文献   

8.
An enantioselective high-performance liquid chromatographic method for the determination of E3810, a new anti-ulcer agent, in Beagle dog plasma and rat plasma has been developed. After extraction from plasma with ethyl acetate. E3810 enantiomer were measured by reversed-phase high-performance liquid chromatography on a Chiralcel OD-R column. The enantiomers were detected by ultraviolet absorbance detection at 290 nm. The recoveries of E3810 enantiomers and internal standard were greater than 91%. The calibration curves were linear from 0.03 to 20 μg/ml for Beagle dog plasma and from 0.1 to 100 μg/ml for rat plasma. The limits of quantification of both enantiomers were 0.03 μg/ml for Beagle dog plasma and 0.1 μg/ml for rat plasma. The intra- and inter-day accuracy and precision data showed good reproducibility of the method. The assay was applied for the analysis of E3810 enantiomers in plasma after intravenous administration of racemic E3810 to Beagle dogs and rats. This method should be very useful for enantioselective pharmacokinetic studies of E3810.  相似文献   

9.
A direct, isocratic, and simple reversed-phase HPLC method was described for the separation of enantiomers of the proton pump inhibitor, rac-pantoprazole (PAN) using cellulose-based chiral stationary phases (Chiralcel OD-R and Chiralcel OJ-R). Some structurally related chiral benzimidazole sulfoxides, rac-omeprazole (OME) and raclansoprazole (LAN), were also studied. Chiralcel OJ-R was successful in the resolution of enantiomers of rac-PAN and rac-OME, while Chiralcel OD-R was most suitable for resolving the enantiomers of rac-LAN. Highest enantioselectivity to rac-PAN and rac-OME was achieved on Chiralcel OJ-R by using acetonitrile as an organic modifier, whereas methanol afforded better resolution of rac-LAN on Chiralcel OD-R than acetonitrile. Increases in buffer concentration and column temperature decreased retention and did not improve the resolution of the enantiomers on both columns. Using a mixture of 50 mM sodium perchlorate solution and acetonitrile as a mobile phase at a flow rate of 0.5 ml/min, maximum separation factors of 1.26 and 1.13 were obtained for the enantiomers of rac-PAN and rac-OME using a Chiralcel OJ-R column, while maximum separation factor of 1.16 was obtained for the enantiomers of rac-LAN using a Chiralcel OD-R column. © 1995 Wiley-Liss, Inc.  相似文献   

10.
We present a method for the enantioselective analysis of propafenone in human plasma for application in clinical pharmacokinetic studies. Propafenone enantiomers were resolved on a 10-μm Chiralcel OD-R column (250×4.6 mm I.D.) after solid-phase extraction using disposable solid-phase extraction tubes (RP-18). The mobile phase used for the resolution of propafenone enantiomers and the internal standard propranolol was 0.25 M sodium perchlorate (pH 4.0)–acetonitrile (60:40, v/v), at a flow-rate of 0.7 ml/min. The method showed a mean recovery of 99.9% for (S)-propafenone and 100.5% for (R)-propafenone, and the coefficients of variation obtained in the precision and accuracy study were below 10%. The proposed method presented quantitation limits of 25 ng/ml and was linear up to a concentration of 5000 ng/ml of each enantiomer.  相似文献   

11.
The simultaneous determination of methadone (Mtd) enantiomers and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), in human urine and serum by enantioselective HPLC using a new Cyclobond I-2000 RSP column is described. After alkaline extraction from urine or serum with estazolam as an internal standard, Mtd enantiomers and its metabolite (EDDP) are separated on the previous column with reversed-mobile phase and detected at 210 nm. Peak resolutions are about 2.0 for Mtd enantiomers. The relative standard deviations (R.S.D.) of Mtd and EDDP standards are between 0.5 and 4.5%. Most drugs of abuse are shown not to interfere with this technique. The method has been applied to study levels of each Mtd enantiomer and of its racemic metabolite in urine and serum of patients under maintenance treatment for opiate dependence. In urine, R-(−)-Mtd levels are always higher (about 2±0.5-fold_ than those of S-(+)-Mtd and in most cases, metabolite concentrations are greater than those of global Mtd enantiomers. However, the R-(−) enantiomer levels of residual drug in serum of some patients were lower than those of its antipode. This method is suitable for pharmacokinetic and toxicological studies of Mtd enantiomers and its major metabolite in biological fluids.  相似文献   

12.
Enantioselective separations on chiral stationary phases with or without derivatization were developed and compared for the HPLC analysis of (+)-(R)- and (-)-(S)-metoprolol acidic metabolite in human plasma and urine. The enantiomers were analysed in plasma and urine without derivatization on a Chiralcel OD-R column, and in urine after derivatization using methanol in acidic medium on a Chiralcel OD-H column. The quantitation limits were 17 ng of each enantiomer/ml plasma and 0.5 microgram of each enantiomer/ml urine using both methods. The confident limits show that the methods are compatible with pharmacokinetic investigations of the enantioselective metabolism of metoprolol. The methods were employed in a metabolism study of racemic metoprolol administered to a patient phenotyped as an extensive metabolizer of debrisoquine. The enantiomeric ratio (+)-(R)/(-)-(S)-acid metabolite was 1.1 for plasma and 1.2 for urine. Clearances were 0.41 and 0.25 l/h/kg, respectively, for the (+)-(R)- and (-)-(S)-enantiomers. The correlation coefficients between the urine concentrations of the acid metabolite enantiomers obtained by the two methods were >0.99. The two methods demonstrated interchangeable application to pharmacokinetics.  相似文献   

13.
A specific and reproducible HPLC method using a Chiral-AGP column and UV detection was developed for the evaluation of the pharmacokinetic profile of oxodipine enantiomers in dog and man. Each enantiomer was determined in plasma in the concentration range 1–400 ng/ml using the internal standard calibration method with linear regression analysis. After extraction of oxodipine and the internal standard at alkaline pH with diethyl ether—n-hexane (50:50, v/v), this method permitted the determination of each enantiomer at levels down to 10 ng/ml in dog plasma and 25 ng/ml in human plasma with sufficient accuracy (relative error <11%, n = 6) and precision (coefficient of variation <16%, n = 6). The extracted plasma volume was 500 μl and after evaporation of the organic phase, the dry residue was dissolved in 100 μl of water—2-propanol; an aliquot of 80 μl was injected into the HPLC system.  相似文献   

14.
A reliable and sensitive high-performance liquid chromatographic (HPLC) method is presented for the determination of total (free and conjugated) plasma dopamine and the enantiomers R- and S-salsolinol. Plasma is purified on two cartridges, containing primary and secondary amines and phenylboronic acid. Dopamine, R- and S-salsolinol are then separated by HPLC using a β-cyclodextrin-OH phase column. The eluate is monitored electrochemically, without further purification nor derivatization. The method is suited for routine analysis. It allows the detection of total (free and conjugated) dopamine and R- and S-salsolinol in human plasma in concentrations as low as 0.02 ng/ml plasma. The sensitivity is sufficient to measure the naturally occurring levels of salsolinol.  相似文献   

15.
Citalopram (CITA) is available as a racemic mixture and as a pure enantiomer. Its antidepressive action is related to the (+)-(S)-CITA and to the metabolite (+)-(S)-demethylcitalopram (DCITA). In the present investigation, a method for the analysis of CITA and DCITA enantiomers in human and rat plasma was developed and applied to the study of pharmacokinetics. Plasma samples (1 ml) were extracted at pH 9.0 with toluene:isoamyl alcohol (9:1, v/v). The CITA and DCITA enantiomers were analyzed by LC-MS/MS on a Chiralcel OD-R column. Recovery was higher than 70% for both enantiomers. The quantification limit was 0.1 ng/ml, and linearity was observed up to 500 ng/ml plasma for each CITA and DCITA enantiomer. The method was applied to the study of the kinetic disposition of CITA administered in a single oral dose of 20 mg to a healthy volunteer and in a single dose of 20 mg/kg (by gavage) to Wistar rats (n = 6 for each time). The results showed a higher proportion of the (-)-(R)-CITA in human and rat plasma, with S/R AUC ratios for CITA of 0.28 and 0.44, respectively. S/R AUC ratios of DCITA were 0.48 for rats and 1.04 for the healthy volunteer.  相似文献   

16.
An efficient route to the pharmaceutically important (6S,9R)-11-oxo-5,6,7,8,9,10-hexahydro-6,9-methanobenzocyclooctene intermediate has been demonstrated via kinetic resolution of 11-oxo-5,6,7,8,9,10-hexahydro-6,9-methanobenzocyclooctene using a commercially available ketoreductase. Biocatalytics KRED 101 has been shown to selectively reduce the (6R,9S) enantiomer leaving behind the desired (6S,9R) enantiomer. This novel reaction is the first demonstration of a high yielding (44% versus 50% maximum theoretical yield) highly stereoselective (>99% ee) resolution of a bicyclic ketone, via enzymatic reduction using a commercially available ketoreductase, where the stereochemistry of the substrate is determined by a bridged ring system. Several challenges were overcome, including enhancing the selectivity of the enzyme by controlling temperature and increasing substrate solubility by employing a combination of cyclodextrin and organic co-solvent in the aqueous reaction system.  相似文献   

17.
A sensitive gas chromatographic assay using mass selective-detection has been developed for the simultaneous quantitation of the enantiomers of (±)-gacyclidine (a non competitive N-methyl-

-aspartate antagonist) in human plasma. Gacyclidine enantiomers and phencyclidine (PCP), the internal standard, were extracted using a single-step liquid–liquid extraction with hexane at pH 8.0. Each enantiomer was separated on a chiral gas chromatography capillary column and specifically detected by mass spectrometry (MS) in selected-ion monitoring (SIM) mode. Gacyclidine enantiomers and PCP were monitored using the fragment ions at m/z 206 and 200, respectively. No interference was observed from endogenous components. The limit of quantitation (LOQ) for each enantiomer of gacyclidine was 300 pg/ml by using plasma samples of 500 μl. The calibration curves were linear (r2=0.998) over a range of 0.3125 to 20 ng/ml. The extraction efficiency was higher than 95% for both enantiomers. Intra- and inter-day bias were less than 10% at every standard curve concentration. Intra-day precision was less than 19% for (−)-gacyclidine and 15% for (+)-gacyclidine. Inter-day precision was below 15% for both enantiomers. The assay was validated for an enantioselective pharmacokinetic study in healthy male volunteers.  相似文献   

18.
A method has been developed for the determination of total celiprolol (sum of enantiomers) or the enantiomers (R)-celiprolol and (S)-celiprolol in plasma by high-performance liquid chromatography with UV and fluorescence detection. After extraction from alkalinized plasma with methyl-tert-butyl ether and back-extraction into 0.01 M HCl (for total celiprolol determination) or after evaporation of the organic phase and derivatisation with R(−)-1-(1-naphthyl)ethyl isocyanate (enantiomer determination), total celiprolol or its diastereomeric derivatives were chromatographed on a reversed-phase HPLC column with a mixture of acetonitrile and phosphate buffer pH 3.5 (+0.05% triethylamine). Acebutolol was used as internal standard. Linearity was obtained in the range of 5 to 2000 ng/ml for total and 2.5 to 500 ng/ml for enantiomer determination. Intra-day and inter-day variation was lower than 10%. The method can be applied for analysis of plasma samples obtained from patients treated with oral racemic celiprolol doses.  相似文献   

19.
Enantiomers of disopyramide (DP), flecainide (FLC) and verapamil (VP) were extracted from rat plasma and tissues (brain, lung, heart, liver, kidney and muscle), followed by quantitative determination using enantioselective high-performance liquid chromatography with chiral stationary-phase columns. The recoveries of S-(+)- and R-(−)-DP from tissues were higher than 69%, and the within- and between-day coefficients of variation were very low (0.5 – 5.7%). The lower limits of detection in each tissue were less than 289 ng/g tissue. The recoveries of S-(+)- and R-(−)-FLC from tissues were higher than 88%, and the within- and between-day coefficients of variation were 1.2–6.0%. The lower limits of detection in each tissue were less than 37 ng/g tissue. The recoveries of S-(−)- and R-(+)-VP from tissues were higher than 80%, and the within- and between-day coefficients of variation were 0.5–6.2%. The lower limits of detection in each tissue were less than 51 ng/g tissue. The analytical methods established in this study will be suitable for determining the concentrations of the enantiomers of these anti-arrhythmic agents in rat plasma and tissues.  相似文献   

20.
An analytical method for the enantioselective determination of selfotel in human urine has been developed and validated. The method is based on high-performance liquid chromatography and utilizes CGS 20005 (a selfotel analog) as the internal standard. Urine samples were derivatized in situ with o-phthalic dicarboxaldehyde–3-mercaptopropionic acid and 9-fluorenylmethyl chloroformate (FMOC). Chromatographic separations of the FMOC derivatives of selfotel enantiomers and the internal standard were achieved using a column switching system consisting of an Inertsil ODS-2 column (75×4.6 mm I.D., 5 μm) and a Chiralcel OD-R column (250×4.6 mm I.D., 10 μm). The composition of the mobile phase was acetonitrile–0.1 M phosphate buffer, pH 2.50 (35:65) for the Inertsil ODS-2 column and acetonitrile–0.1 M phosphate buffer, pH 2.00 (35:65) for the Chiralcel OD-R column. The analytes were monitored using fluorescence detection at an excitation wavelength of 262 nm and an emission wavelength of 314 nm. The limit of quantification (LOQ) for this method is 0.25 μg/ml for each selfotel enantiomer. The method was successfully utilized to determine preliminary selfotel stereospecific pharmacokinetics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号