首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Amperometric glucose biosensor based on single-walled carbon nanohorns   总被引:2,自引:0,他引:2  
Liu X  Shi L  Niu W  Li H  Xu G 《Biosensors & bioelectronics》2008,23(12):1887-1890
The biosensing application of single-walled carbon nanohorns (SWCNHs) was demonstrated through fabrication of an amperometric glucose biosensor. The biosensor was constructed by encapsulating glucose oxidase in the Nafion-SWCNHs composite film. The cyclic voltammograms for glucose oxidase immobilized on the composite film displayed a pair of well-defined and nearly symmetric redox peaks with a formal potential of -0.453 V. The biosensor had good electrocatalytic activity toward oxidation of glucose. To decrease detection potential, ferrocene monocarboxylic acid was used as a redox mediator. The mediated glucose biosensor shows a linear range from 0 to 6.0 mM. The biosensor shows high sensitivity (1.06 microA/mM) and stability, and can avoid the commonly coexisted interference. Because of impressive properties of SWCNHs, such as high purity and high surface area, SWCNHs and their composites are expected to be promising material for biomolecular immobilization and biosensing applications.  相似文献   

2.
This study demonstrated that redox hydrogel-modified carbon nanotube (CNT) electrodes can be developed as an amperometric sensor that are sensitive, specific and fast and do not require auxiliary enzymes. A redox polymer, poly(vinylimidazole) complexed with Os(4,4'-dimethylbpy)(2)Cl (PVI-dmeOs) was electrodeposited on Ta-supported multi-walled CNTs. The resulted PVI-dmeOs thin film did not change the surface morphology of the CNTs, but turned the CNT surface from hydrophobic to hydrophilic, as studied by scanning electron microscopy (SEM) and static water contact angle measurements. Cyclic voltammetry measurements in a Fe(CN)(6)(3-) solution and electrochemical impedance measurements in an equimolar Fe(CN)(6)(3-/4-) solution demonstrated that the PVI-dmeOs hydrogel thin film was electronic conductive with a resistance of about 15Omega. The PVI-dmeOs/CNT electrodes sensed rapidly, sensitively and specifically to model redox enzymes (glucose oxidase (GOD) and lactate oxidase (LOD)) in amperometric experiments in electrolyte solutions containing the substrates of the measured redox enzymes. Both the CNT substrate and the thin PVI-dmeOs film enhanced the sensing sensitivities. Exploration of the mechanisms suggests that the PVI-dmeOs film may enhance the sensing sensitivities by wiring the enzyme molecules through the redox centers tethered on the mobile redox polymer backbones to the CNT electrodes.  相似文献   

3.
A ferrocene-derivatised detergent, (11-ferrocenylundecyl) trimethylammonium bromide (FTMAB), when oxidised to the corresponding ferricinium ion, was found by electrochemical studies to be an effective electron acceptor for reduced glucose oxidase of Aspergillus niger (EC 1.13.4) and thus acts as a electron-transfer mediator between glucose oxidase and a working electrode held at a potential sufficiently positive to reoxidise reduced FTMAB. An increase in mediating activity was produced when FTMAB was present in concentrations above its critical micelle concentration. An 'enzyme electrode' was formed by adsorption of glucose oxidase and FTMAB surfactant on a graphite rod. The electrode functioned as an amperometric biosensor for glucose in phosphate-buffered saline solution. A mixed micelle of glucose oxidase and FTMAB, probably adsorbed on the electrode surface, appears to be advantageous for the amperometric determination of glucose. Additionally, glucose oxidase was treated with alpha-mannosidase. When this partially-deglycosylated glucose oxidase was incorporated in an enzyme electrode, a 100-fold increase in the second-order rate constant (k) for electron transfer between the enzyme and FTMAB was observed, together with increased current densities, with respect to the equivalent values for FTMAB and commercial glucose oxidase. The use of deglycosylated enzymes in biosensors is suggested.  相似文献   

4.
Escherichia coli cells, which contain apo-glucose dehydrogenase, were used in constructing a mediated amperometric glucose sensor. The E. coli modified glucose sensor, which was prepared by immobilizing E. coli cells behind a dialysis membrane on a carbon paste electrode containing 2,3-dimethoxy-5-methyl-1,4-benzoquinone (Q(0)), produced a current for the electrocatalytic oxidation of glucose with Q(0) as an electron transfer mediator only after the addition of a trace amount of pyrroloquinoline quinone (PQQ), the cofactor of the enzyme. This allows a novel method of glucose measurements free from the interference of the redox active substances, if contained, in a sample solution. The glucose sensor was insensitive to dioxygen; the currents measured under anaerobic and aerobic conditions, and even under dioxygen saturated conditions were almost the same in magnitude at a given concentration of glucose over the range of 0.2-10 mM. Response time of the glucose sensor was 2 min to attain 90% level of the steady-state current. The E. coli modified glucose sensor was reusable when treated with ethylenediaminetetraacetic acid (EDTA). When E. coli cells were lyophilized, they could be stored at room temperature in a dry box for more than six months without loss of the catalytic activity.  相似文献   

5.
A novel glucose biosensor was developed based on the adsorption of glucose oxidase at a TiO(2)-Graphene (GR) nanocomposite electrode. A TiO(2)-GR composite was synthesized from a colloidal mixture of TiO(2) nanparticles and graphene oxide (GO) nanosheets by an aerosol assisted self-assembly (AASA). The particle morphology of all TiO(2)-GR composites was spherical in shape. It was observed that micron-sized TiO(2) particles were encapsulated by GR nanosheets and that the degree of encapsulation was proportional to the ratio of GO/TiO(2). The amperometric response of the glucose biosensor fabricated by the TiO(2)-GR composite was linear against a concentration of glucose ranging from 0 to 8mM at -0.6V. The highest sensitivity was noted at about 6.2μA/mMcm(2). The as prepared glucose biosensor based on the TiO(2)-GR composite showed higher catalytic performance for glucose redox than a pure TiO(2) and GR biosensor.  相似文献   

6.
Biomolecule-nanoparticle (NP) [or quantum-dot (QD)] hybrid systems combine the recognition and biocatalytic properties of biomolecules with the unique electronic, optical, and catalytic features of NPs and yield composite materials with new functionalities. The biomolecule-NP hybrid systems allow the development of new biosensors, the synthesis of metallic nanowires, and the fabrication of nanostructured patterns of metallic or magnetic NPs on surfaces. These advances in nanobiotechnology are exemplified by the development of amperometric glucose sensors by the electrical contacting of redox enzymes by means of AuNPs, and the design of an optical glucose sensor by the biocatalytic growth of AuNPs. The biocatalytic growth of metallic NPs is used to fabricate Au and Ag nanowires on surfaces. The fluorescence properties of semiconductor QDs are used to develop competitive maltose biosensors and to probe the biocatalytic functions of proteases. Similarly, semiconductor NPs, associated with electrodes, are used to photoactivate bioelectrocatalytic cascades while generating photocurrents.  相似文献   

7.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

8.
The direct electrocatalytic oxidation of glucose in alkaline medium at nanoscale nickel hydroxide modified carbon ionic liquid electrode (CILE) has been investigated. Enzyme free electro-oxidation of glucose have greatly been enhanced at nanoscale Ni(OH)(2) as a result of electrocatalytic effect of Ni(+2)/Ni(+3) redox couple. The sensitivity to glucose was evaluated as 202 microA mM(-1)cm(-2). From 50 microM to 23 mM of glucose can be selectively measured using platelet-like Ni(OH)(2) nanoscale modified CILE with a detection limit of 6 microM (S/N=3). The nanoscale nickel hydroxide modified electrode is relatively insensitive to electroactive interfering species such as ascorbic acid (AA), and uric acid (UA) which are commonly found in blood samples. Long-term stability, high sensitivity and selectivity as well as good reproducibility and high resistivity towards electrode fouling resulted in an ideal inexpensive amperometric glucose biosensor applicable for complex matrices.  相似文献   

9.
A series of 8-(ferrocenylalkyl)theophylline conjugates were synthesized for evaluation in a homogeneous, competitive electrochemical immunoassay for theophylline with amperometric detection of the ferrocene label at +320 mV. The electrical signal was amplified via redox cycling with the glucose oxidase/glucose system. The resulting catalytic current was strongly inhibited upon binding of the conjugates to anti-theophylline antibodies such that a large excess of theophylline was required to achieve complete reversal leading to an assay with poor sensitivity in the clinical range. A study of the nonspecific interaction of the antibodies with various ferrocene derivatives indicated that this was reduced when a charged functional group was present on the metallocene ring. Consequently, a conjugate was synthesized with a quaternary ammonium group which when incorporated into the assay resulted in improved sensitivity.  相似文献   

10.
An outer ultra-thin-polydimethyldichlorosiloxane film composite membrane has been used as the outer covering barrier in an amperometric glucose oxidase enzyme electrode biosensor. The composite membrane was formed via the condensation polymerisation of dimethyldichlorosilane at the surface of a host porous alumina membrane. Homogeneous polydimethyldichlorosiloxane films of <100 nm thickness acted as effective substrate diffusional barriers and were supported by the underlying porous alumina surface. Glucose and oxygen permeability coefficients were determined using diffusion chamber apparatus. Polysiloxane composite membranes were found to offer some screening functionality towards anionic biological interferents such as ascorbate. On exposure to blood an approximate 25% signal drift was observed during the first 2 h exposure to blood; after this time responses remained almost stable. Whole blood glucose determinations showed a close correlation (r(2)=0.98) to analyses performed via standard hospital analyses.  相似文献   

11.
In this paper we introduce a preliminary work in which a redox mediator containing polyvinylferrocene immobilized on silica gel particles is synthesized. Carbon paste electrodes prepared with this polymeric mediator were studied for their stability in aqueous media for a month. The results indicated that approximately 70% of the initial activity was retained after a month. A steady state amperometric measurement of this carbon paste electrode containing this mediator and glucose oxidase at different potentials showed a linear relationship at elevated glucose concentration.  相似文献   

12.
We recently discovered that post-translational redox modulation of ADP-glucose pyrophosphorylase (AGPase) is a powerful new mechanism to adjust the rate of starch synthesis to the availability of sucrose in growing potato tubers. A strong correlation was observed between the endogenous levels of sucrose and the redox-activation state of AGPase. To identify candidate components linking AGPase redox modulation to sugar supply, we used potato tuber discs as a model system. When the discs were cut from growing wild-type potato tubers and incubated for 2 h in the absence of sugars, redox activation of AGPase decreased because of a decrease in internal sugar levels. The decrease in AGPase redox activation could be prevented when glucose or sucrose was supplied to the discs. Both sucrose uptake and redox activation of AGPase were increased when EDTA was used to prepare the tuber discs. However, EDTA treatment of discs had no effect on glucose uptake. Feeding of different glucose analogues revealed that the phosphorylation of hexoses by hexokinase is an essential component in the glucose-dependent redox activation of AGPase. In contrast to this, feeding of the non-metabolisable sucrose analogue, palatinose, leads to a similar activation as with sucrose, indicating that metabolism of sucrose is not necessary in the sucrose-dependent AGPase activation. The influence of sucrose and glucose on redox activation of AGPase was also investigated in discs cut from tubers of antisense plants with reduced SNF1-related protein kinase activity (SnRK1). Feeding of sucrose to tuber discs prevented AGPase redox inactivation in the wild type but not in SnRK1 antisense lines. However, feeding of glucose leads to a similar activation of AGPase in the wild type and in SnRK1 transformants. AGPase redox activation was also increased in transgenic tubers with ectopic overexpression of invertase, containing high levels of glucose and low sucrose levels. Expression of a bacterial glucokinase in the invertase-expressing background led to a decrease in AGPase activation state and tuber starch content. These results show that both sucrose and glucose lead to post-translational redox activation of AGPase, and that they do this by two different pathways involving SnRK1 and an endogenous hexokinase, respectively.  相似文献   

13.
Fermentation redox potential reflects the momentary physiological status of organisms. Controlling redox potential can modulate the redistribution of intracellular metabolic flux to favor the formation of the desired metabolite. Accordingly, we have developed three redox potential-controlled schemes to maximize their effects on the very-high-gravity (VHG) ethanol fermentation. They are aeration-controlled scheme (ACS), glucose-controlled feeding scheme (GCFS), and combined chemostat and aeration-controlled scheme (CCACS). These schemes can maintain fermentation redox potential at a prescribed level (i.e., -50, -100, and -150 mV) by supplementing sterile air, fresh glucose media, or a combination of sterile air and fresh glucose media into a fermenter to counteract the decline of redox potential due to yeast growth. When ACS was employed, the fermentation efficiency at -150 mV is superior to the other two redox potential levels especially when the initial glucose concentration is higher than 250 g/l. The redox potential-controlled period for ACS, GCFS, and CCACS at -150 mV under the same 200 g glucose/l condition was 2.5, 21.7 and 64.6h and the corresponding fermentation efficiency was 85.9,89.3 and 92.7%, respectively.  相似文献   

14.
In this study, we analyzed how distinct glycolysis inhibitors influenced the redox status of retinal cells, used as a neuronal model. Three different approaches were used to inhibit glycolysis: the cells were submitted to iodoacetic acid (IAA), an inhibitor of glyceraldehyde 3-phosphate dehydrogenase, to 2-deoxy-glucose (DG) in glucose-free medium, which was used as a substitute of glucose, or in the absence of glucose. The redox status of the cells was evaluated by determining the reduction of MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide). By the analysis of dose-response curves of MTT reduction, IAA showed values of IC50 = 7.02 × 10–5 M, whereas DG showed values of IC50 = 7.42 × 10–4 M. Upon 30 min-incubation, glucose deprivation, per se, did not significantly affect MTT reduction. We also evaluated the reduction of MTT as an indicator of cell injury by exposing the cells to 100 M glutamate during the decrement of glycolysis function. In the presence of glutamate, for 2 h, there was a decrease in MTT reduction, which was potentiated in the presence of DG (10-20% decrease), in the presence of IAA (about 30% decrease) or in glucose-free medium (about 30% decrease). Major changes observed by the MTT assay, upon exposure to glutamate, indicative of changes in the redox status of retinal cells, were concomitant with variations in intracellular ATP. Under glucose deprivation, endogenous ATP decreased significantly from 38.9 ± 4.4 to 13.3 ± 0.7 nmol/mg protein after exposure to 100 M glutamate. The results support a different vulnerability of retinal cells after being exposed to distinct forms of glycolysis inhibition.  相似文献   

15.
This work describes an electron transfer mediator-assisted amperometric flow injection method for assessing redox enzyme activity in different subcellular compartments of the phosphoglucose isomerase deletion mutant strain of Saccharomyces cerevisiae, EBY44. The method is demonstrated using the ferricyanide-menadione double mediator system to study the effect of dicoumarol, an inhibitor of cytosolic and mitochondrial oxidoreductases and an uncoupler of the electron transport chain. Evaluation of the role of NAD(P)H-producing pathways in mediating biological effects is facilitated by introducing either fructose or glucose as the carbon source, yielding either NADH or NADPH through the glycolytic or pentose phosphate pathway, respectively. Respiratory noncompetent cells show greater inhibition of cytosolic menadione-reducing enzymes when NADH rather than NADPH is produced. Spectrophotometric in vitro assays show no difference between the cofactors. Respiratory competent cells show cytosolic inhibition only when NADPH is produced, whereas production of NADH reveals uncoupling at low dicoumarol concentrations and inhibition of complexes III and IV at higher concentrations. Spectrophotometric assays only indicate the presence of cytosolic inhibition regardless of the reduced cofactor used. This article shows the applicability of the amperometric method and emphasizes the significance of determining biological effects of chemicals in living cells.  相似文献   

16.
An enzyme electrode was constructed for amperometric determination of xylose and glucose. The electrode is based on the PQQ-dependent membrane-bound aldose dehydrogenase (ALDH) from Gluconobacter oxydans. ALDH was covalently immobilized on a graphite electrode. Immobilized dimethylferrocene, soluble ferrocene carboxylic acid and phenazine methosulphate were used as electron transfer mediators. When xylose was measured electrochemically using an electrode modified with ALDH and dimethylferrocene, the linear measurement range extended to 100 mM. For glucose measurement the linear measurement range was about one-tenth of that for xylose. The electrode showed fairly good stability; 50% of the original electrode response was still obtained after 5 days of intermittent use. The effect of possible leakage of adsorbed mediator was determined by measuring the response of an electrode with soluble mediator as a function of time. The reproducibility of the electrode was good, the standard deviation of the electrode response in ten measurements with the same electrode being only 2.7%.  相似文献   

17.
An interference and cross-talk free dual electrode amperometric biosensor integrated with a microdialysis sampling system is described, for simultaneous monitoring of glucose and lactate by flow injection analysis. The biosensor is based on a conventional thin layer flow-through cell equipped with a Pt dual electrode (parallel configuration). Each Pt disk was modified by a composite bilayer consisting of an electrosynthesised overoxidized polypyrrole (PPYox) anti-interference membrane covered by an enzyme entrapping gel, obtained by glutaraldehyde co-crosslinking of glucose oxidase or lactate oxidase with bovine serum albumin. The advantages of covalent immobilization techniques were coupled with the excellent interference-rejection capabilities of PPYox. Ascorbate, cysteine, urate and paracetamol produced lactate or glucose bias in the low micromolar range; their responses were, however, completely suppressed when the sample was injected through the microdialysis unit. Under these operational conditions the flow injection responses for glucose and lactate were linear up to 100 and 20 mM with typical sensitivities of 9.9 (+/- 0.1) and 7.2 (+/- 0.1) nA/mM. respectively. The shelf-lifetime of the biosensor was at least 2 months. The potential of the described biosensor was demonstrated by the simultaneous determination of lactate and glucose in untreated tomato juice samples; results were in good agreement with those of a reference method.  相似文献   

18.
A novel amperometric glucose biosensor based on the nine layers of multilayer films composed of multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide cross-linking reaction, respectively. A cleaned Pt electrode was immersed in PAA, MWCNTs, cysteamine and GNp, respectively, followed by the adsorption of GOD, assembling the one layer of multilayer films on the surface of Pt electrode (GOD/GNp/MWCNTs/Pt electrode). Repeating the above process could assemble different layers of multilayer films on the Pt electrode. PBS washing was applied at the end of each assembly deposition for dissociating the weak adsorption. Film assembling and characterization were studied by transmission electron microscopy and quartz crystal microbalance, and properties of the resulting glucose biosensors were measured by electrochemical measurements. The marked electrocatalytic activity of Pt electrode based on multilayer films toward H2O2 produced during GOD enzymatic reactions with glucose permitted effective low-potential amperometric measurement of glucose. Taking the sensitivity and selectivity into consideration, the applied potential of 0.35 V versus Ag/AgCl was chosen for the oxidation detection of H2O2 in this work. Among the resulting glucose biosensors, the biosensor based on nine layers of multilayer films was best. It showed a wide linear range of 0.1–10 mM glucose, with a remarkable sensitivity of 2.527 μA/mM, a detection limit of 6.7 μM estimated at a signal-to-noise ratio of 3 and fast response time (within 7 s). Moreover, it exhibited good reproducibility, long-term stability and the negligible interferences of ascorbic acid, uric acid and acetaminophen. The study can provide a feasible approach on developing new kinds of oxidase-based amperometric biosensors, and can be used as an illustration for constructing various hybrid structures.  相似文献   

19.
The energy metabolism of rat thymus cells has been investigated using preparations of isolated cells obtained by mechanical treatment of whole organs. The addition of glycolytic substrates such as glucose, pyruvate and lactate stimulates the endogenous respiration of these cells by 50%. On the other hand, succinate, glutamate and malate do not produce any effect. Oligomycin (10 mug/ml) inhibits both endogenous and glucose stimulated respiration by about 40%; 2, 4-DNP (50 muM) increases by 100% glucose induced respiration. The results obtained by using mitochondrial and glycolytic inhibitors as well as aminoxyacetic acid (AOA) and following pyridine nucleotides redox changes, support the idea that in thymus cells glucose is able to induce a great enhancement of O2 consumption both by raising the level of endogenous pyruvate and feeding the mitochondrial respiratory chain with cytosolic reducing equivalents, through an active malate-aspartate shuttle. Thymus cells exhibit a high Pasteur effect (74%). Both AOA and 2,4 DNP are able to stimulate aerobic lactate accumulation by 200% and 100% respectively, indicating that either the redox or phosphate potential do influence the rate of aerobic glycolysis in isolated thymus cells. Similar experiments are also reported on other cells with well known biochemical characteristics.  相似文献   

20.
A miniaturized glucose biosensor in which glucose oxidase (GOD) and poly(p-phenylenediamine) (poly-PPD) were coimmobilized at the surface of a platinum microdisk electrode was developed and used successfully for amperometric determination of glucose. The performance of sensors prepared at different monomer concentrations and polymerization potentials with different media was investigated in detail. It was found that similarly to poly(o-phenylenediamine) (poly-OPD), (poly-PPD) noticeably eliminated the electrochemical interference of ascorbic acid, uric acid, and l-cysteine. The amperometric response of glucose with the biosensor under optimal conditions exhibited a linear relationship in the range of 5.0 x 10(-5) to 3.0 x 10(-3) M with correlation coefficient 0.9995. According to the Michaelis-Menten equation, the apparent Michaelis constant for glucose and the maximum steady-state current density of the poly-PPD/GOD-modified microelectrode were 3.94 mM and 607.5 microA cm(-2), respectively. The current density of the sensor responding to glucose in the linear range can reach 160 microA cm(-2) mM(-1), which is far greater than that obtained using poly-OPD and poly(phenol) film. In addition, the stability of the sensor was examined over a 2-month period.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号