首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
The accuracy of a computerized metabolic system, using inspiratory and expiratory methods of measuring ventilation, was assessed in eight male subjects. Gas exchange was measured at rest and during five stages on a cycle ergometer. Pneumotachometers were placed on the inspired and expired side to measure inspired (VI) and expired ventilation (VE). The devices were connected to two systems sampling expired O(2) and CO(2) from a single mixing chamber. Simultaneously, the criterion (Douglas bag, or DB) method assessed VE and fractions of O(2) and CO(2) in expired gas (FE(O(2)) and FE(CO(2))) for subsequent calculation of O(2) uptake (VO(2)), CO(2) production (VCO(2)), and respiratory exchange ratio. Both systems accurately measured metabolic variables over a wide range of intensities. Though differences were found between the DB and computerized systems for FE(O(2)) (both inspired and expired systems), FE(CO(2)) (expired system only), and VO(2) (inspired system only), the differences were extremely small (FE(O(2)) = 0.0004, FE(CO(2)) = -0.0003, VO(2) = -0.018 l/min). Thus a computerized system, using inspiratory or expiratory configurations, permits extremely precise measurements to be made in a less time-consuming manner than the DB technique.  相似文献   

2.
Some infants sleep facedown for long periods with no ill effects, whereas others become hypoxemic. Rebreathing of expired air has been determined by CO(2) measurement; however, O(2) levels under such conditions have not been determined. To evaluate this and other factors influencing inspired gas concentrations, we studied 21 healthy infants during natural sleep while facedown on soft bedding. We measured gas exchange with the environment and bedding, ventilatory response to rebreathing, and concentrations of inspired CO(2) and O(2). Two important factors influencing inspired gas concentrations were 1) a variable seal between bedding and infants' faces and 2) gas gradients in the bedding beneath the infants, with O(2)-poor and CO(2)-rich air nearest to the face, fresher air distal to the face, and larger tidal volumes being associated with fresher inspired air. Minute ventilation increased significantly while rebreathing because of an increase in tidal volume, not frequency. The measured drop in inspired O(2) was significantly greater than the accompanying rise in inspired CO(2). This appears to be due to effects of the respiratory exchange ratio and differential tissue solubilities of CO(2) and O(2) during unsteady conditions.  相似文献   

3.
A method is described for breath-by-breath measurement of alveolar gas exchange corrected for changes of lung gas stores. In practice, the subject inspires from a spirometer, and each expired tidal volume is collected into a rubber bag placed inside a rigid box connected to the same spirometer. During the inspiration following any given expiration the bag is emptied by a vacuum pump. A computer monitors inspiratory and expiratory tidal volumes, drives four solenoid valves allowing appropriate operation of the system, and memorizes end-tidal gas fractions as well as mixed expired gas composition analyzed by mass spectrometer. Thus all variables for calculating alveolar gas exchange, based on the theory developed by Auchincloss et al. (J. Appl. Physiol. 21: 810-818, 1966), are obtained on a single-breath basis. Mean resting and steady-state exercise gas exchange data are equal to those obtained by conventional open-circuit measurements. Breathing rates up to 30 X min-1 can be followed. The breath-to-breath variability of O2 uptake at the alveolar level is less (25-35%) than that measured at the mouth as the difference between the inspired and expired volumes, both at rest and during exercise up to 0.7 of maximum O2 consumption.  相似文献   

4.
Previous studies (J. Appl. Physiol. 58: 978-988 and 989-995, 1985) have shown both worsening ventilation-perfusion (VA/Q) relationships and the development of diffusion limitation during heavy exercise at sea level and during hypobaric hypoxia in a chamber [fractional inspired O2 concentration (FIO2) = 0.21, minimum barometric pressure (PB) = 429 Torr, inspired O2 partial pressure (PIO2) = 80 Torr]. We used the multiple inert gas elimination technique to compare gas exchange during exercise under normobaric hypoxia (FIO2 = 0.11, PB = 760 Torr, PIO2 = 80 Torr) with earlier hypobaric measurements. Mixed expired and arterial respiratory and inert gas tensions, cardiac output, heart rate (HR), minute ventilation, respiratory rate (RR), and blood temperature were recorded at rest and during steady-state exercise in 10 normal subjects in the following order: rest, air; rest, 11% O2; light exercise (75 W), 11% O2; intermediate exercise (150 W), 11% O2; heavy exercise (greater than 200 W), 11% O2; heavy exercise, 100% O2 and then air; and rest 20 minutes postexercise, air. VA/Q inequality increased significantly during hypoxic exercise [mean log standard deviation of perfusion (logSDQ) = 0.42 +/- 0.03 (rest) and 0.67 +/- 0.09 (at 2.3 l/min O2 consumption), P less than 0.01]. VA/Q inequality was improved by relief of hypoxia (logSDQ = 0.51 +/- 0.04 and 0.48 +/- 0.02 for 100% O2 and air breathing, respectively). Diffusion limitation for O2 was evident at all exercise levels while breathing 11% O2.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
A newly designed gas-sampling device using end-tidal CO(2) to separate dead space gas from alveolar gas was evaluated in 12 mechanically ventilated patients. For that purpose, CO(2)-controlled sampling was compared with mixed expiratory sampling. Alveolar sampling valves were easily controlled via CO(2) concentration. Concentrations of four volatile substances were determined in the expired and inspired gas. Isoflurane and isoprene, which did not occur in the inspired air, had ratios of end-tidal to mixed expired concentrations of 1.75 and 1.81, respectively. Acetone and pentane, found in both the inspired and expired air, showed ratios of 0.96 and 1.0, respectively. Precision of concentration measurements was between 2.4% (isoprene) and 11.2% (isoflurane); reproducibility (as coefficient of variation) was 5%. Because the only possible source of isoflurane and isoprene in this setting was patients' blood, selective enrichment of alveolar gas was demonstrated. By using the new sampling technique, sensitivity of breath analysis was nearly doubled.  相似文献   

6.
We have developed a rapid gas-dilution technique, with which pulmonary gas volume can be measured in only 20 s, even in the presence of maldistribution of ventilation. The subject rebreathes from a 0.75-liter anesthetic bag filled with 10% He and 30% O2 in argon. Breath-by-breath flow-weighted inspired concentrations of all gases present are calculated from continuous measurement by mass spectrometry. Insoluble gas concentrations are corrected continuously for shrinkage of the system volume. By use of these corrected values a mathematical extrapolation predicts the equilibrium concentration for He in the absence of complete mixing. Validation of the technique was carried out by comparing volumes calculated from the predicted equilibrium value with those obtained by whole-body plethysmography in 7 normal subjects and 12 patients with lung disease. In normal subjects equilibrium was usually attained within the 20 breaths and no extrapolation was required. In most of the patients, however, equilibrium was not reached and the use of the extrapolation technique increased the proportion of the lung volume measured by gas dilution from 0.82 +/- 0.16 (SD) to 0.95 +/- 0.12 of that measured by plethysmography.  相似文献   

7.
A well-defined relationship has to exist between substance concentrations in blood and in breath if blood-borne volatile organic compounds (VOCs) are to be used as breath markers of disease or health. In this study, the impact of inspired substances on this relationship was investigated systematically. VOCs were determined in inspired and expired air and in arterial and mixed venous blood of 46 mechanically ventilated patients by means of SPME, GC/MS. Mean inspired concentrations were 25% of expired concentrations for pentane, 7.5% for acetone, 0.7% for isoprene and 0.4% for isoflurane. Only if inspired concentrations were <5% did substance disappearance rates from blood and exhalation rates correlate well. Exhaled substance concentrations depended on venous and inspired concentrations. Patients with sepsis had higher n-pentane and lower acetone concentrations in mixed venous blood than patients without sepsis (2.27 (0.37-8.70) versus 0.65 (0.33-1.48) nmol L-1 and 69 (22-99) versus 18 (6.7-56) micromol L-1). n-Pentane and acetone concentrations in breath showed no differences between the patient groups, regardless whether or not expired concentrations were corrected for inspired concentrations. In mechanically ventilated patients, concentration profiles of volatile substances in breath may considerably deviate from profiles in blood depending on the relative amount of inspired concentrations. A simple correction for inspired substance concentrations was not possible. Hence, substances having inspired concentrations>5% of expired concentrations should not be used as breath markers in these patients without knowledge of concentrations in blood and breath.  相似文献   

8.
Although exercise testing is useful in the diagnosis and management of cardiovascular and pulmonary diseases, a rapid comprehensive method for measurement of ventilation and gas exchange has been limited to expensive complex computer-based systems. We devised a relatively inexpensive, technically simple, and clinically oriented exercise system built around a desktop calculator. This system automatically collects and analyzes data on a breath-by-breath basis. Our calculator system overcomes the potential inaccuracies of gas exchange measurement due to water vapor dilution and mismatching of expired flow and gas concentrations. We found no difference between the calculator-derived minute ventilation, CO2 production, O2 consumption, and respiratory exchange ratio and the values determined from simultaneous mixed expired gas collections in 30 constant-work-rate exercise studies. Both tabular and graphic displays of minute ventilation, CO2 production, O2 consumption, respiratory exchange ratio, heart rate, end-tidal O2 tension, end-tidal CO2 tension, and arterial blood gas value are included for aid in the interpretation of clinical exercise tests.  相似文献   

9.
Abstract

A well-defined relationship has to exist between substance concentrations in blood and in breath if blood-borne volatile organic compounds (VOCs) are to be used as breath markers of disease or health. In this study, the impact of inspired substances on this relationship was investigated systematically. VOCs were determined in inspired and expired air and in arterial and mixed venous blood of 46 mechanically ventilated patients by means of SPME, GC/MS. Mean inspired concentrations were 25% of expired concentrations for pentane, 7.5% for acetone, 0.7% for isoprene and 0.4% for isoflurane. Only if inspired concentrations were <5% did substance disappearance rates from blood and exhalation rates correlate well. Exhaled substance concentrations depended on venous and inspired concentrations. Patients with sepsis had higher n-pentane and lower acetone concentrations in mixed venous blood than patients without sepsis (2.27 (0.37–8.70) versus 0.65 (0.33–1.48) nmol L?1 and 69 (22–99) versus 18 (6.7–56) µmol L?1). n-Pentane and acetone concentrations in breath showed no differences between the patient groups, regardless whether or not expired concentrations were corrected for inspired concentrations. In mechanically ventilated patients, concentration profiles of volatile substances in breath may considerably deviate from profiles in blood depending on the relative amount of inspired concentrations. A simple correction for inspired substance concentrations was not possible. Hence, substances having inspired concentrations >5% of expired concentrations should not be used as breath markers in these patients without knowledge of concentrations in blood and breath.  相似文献   

10.
The effect of the partial pressure of O(2) and CO(2) on the acid protease production in solid state fermentation by Aspergillus niger on wheat bran was studied. A fermentation system was used, which allowed on-line reactor measurements and continuous data acquisition of pH, temperature, gas flow, pressure drop and CO(2) production. Six paired combinations of CO(2) and O(2) concentrations were studied. The results showed a direct relationship between pressure drop, production of CO(2) and temperature increase. The pH evolution patterns were similar in all cases but different if the measurements were made on-line or on a liquid homogenate of the fermented substrate. Acid protease production was increased when the gas had 4% CO(2), (vol/vol), and it reached its highest level, a 43% increase over air, with a mixture of 4% CO(2) and 21% O(2). The protease production was strongly related to the mold metabolic activity as represented by the total CO(2) evolved.  相似文献   

11.
In 12 anesthetized paralyzed dogs, pulmonary gas exchange and intrapulmonary inspired gas distribution were compared between continuous-flow ventilation (CFV) and conventional mechanical ventilation (CMV). Nine dogs were studied while they were lying supine, and three dogs were studied while they were lying prone. A single-lumen catheter for tracheal insufflation and a double-lumen catheter for bilateral endobronchial insufflation [inspired O2 fraction = 0.4; inspired minute ventilation = 1.7 +/- 0.3 (SD) 1.kg-1.min-1] were evaluated. Intrapulmonary gas distribution was assessed from regional 133Xe clearances. In dogs lying supine, CO2 elimination was more efficient with endobronchial insufflation than with tracheal insufflation, but the alveolar-arterial O2 partial pressure difference was larger during CFV than during CMV, regardless of the type of insufflation. By contrast, endobronchial insufflation maintained both arterial PCO2 and alveolar-arterial O2 partial pressure difference at significantly lower levels in dogs lying prone than in dogs lying supine. In dogs lying supine, the dependent lung was preferentially ventilated during CMV but not during CFV. In dogs lying prone, gas distribution was uniform with both modes of ventilation. The alveolar-arterial O2 partial pressure difference during CFV in dogs lying supine was negatively correlated with the reduced ventilation of the dependent lung, which suggests that increased ventilation-perfusion mismatching was responsible for the increase in alveolar-arterial O2 partial pressure difference. The more efficient oxygenation during CFV in dogs lying prone suggests a more efficient matching of ventilation to perfusion, presumably because the distribution of blood flow is also nearly uniform.  相似文献   

12.
Six subjects pedaled a stationary cycle ergometer to exhaustion on three separate occasions while breathing gas mixtures of 17, 21, or 60% O2 in N2. Each subject rode for 3 min at work rates of 60, 90, 105 W, followed by 15-W increases every 3 min until exhaustion. Inspired and expired gas fractions, ventilation (V), heart rate, and blood lactate were measured. O2 uptake (VO2) and CO2 output (VCO2) were calculated for the last minute of each work rate; blood samples were drawn during the last 5 s. "Break points" for lactate, V, VCO2, V/VO2, and expired oxygen fraction (FEO2) were mathematically determined. VO2 was not significantly different at any work rate among the three different conditions. Nor did maximal VO2 differ significantly among the three treatments (P greater than 0.05). Lactate concentrations were significantly lower during hyperoxia and significantly higher during hypoxia compared with normoxia. Lactate values at exhaustion were not significantly different among the three treatments. Four subjects were able to work for a longer period of time during hyperoxic breathing. The variations in lactate accumulation as reported in this study cannot be explained on the basis of differences in VO2. The results of this research lend support to the hypothesis that differences in the performance of subjects breathing altered fractions of inspired oxygen may be caused by differences in lactate (or H+) accumulation.  相似文献   

13.
The coupled conservation of mass equations for oxygen, carbon dioxide and nitrogen are written down for a lung model consisting of two homogeneous alveolar compartments (with different ventilation-perfusion ratios) and a shunt compartment. As inspired oxygen concentration and oxygen consumption are varied, the flux of oxygen, carbon dioxide and nitrogen across the alveolar membrane in each compartment varies. The result of this is that the expired ventilation-perfusion ratio for each compartment becomes a function of inspired oxygen concentration and oxygen consumption as well as parameters such as inspired ventilation and alveolar perfusion. Another result is that the "inspired ventilation-perfusion ratio and the "expired ventilation-perfusion ratio differ significantly, under some conditions, for poorly ventilated lung compartments. As a consequence, we need to distinguish between the "inspired ventilation-perfusion distribution, which is independent of inspired oxygen concentration and oxygen consumption, and the "expired ventilation-perfusion distribution, which we now show to be strongly dependent on inspired oxygen concentration and less dependent oxygen consumption. Since the multiple inert gas elimination technique (MIGET) estimates the "expired ventilation-perfusion distribution, it follows that the distribution recovered by MIGET may be strongly dependent on inspired oxygen concentration.  相似文献   

14.
In 19 pentobarbital sodium-anesthetized kittens aged 5-34 days, inspired O2 was reduced from 21 to 6-12%. Respiratory frequency (f) and tidal volume (VT) increased within 30 s. Over 5 min f fell to about 60% below control; VT usually fell but remained above control. Arterial pressure fell in 80% of trials, sometimes before f fell. Arterial CO2 was below control, but raising inspired CO2 to keep expired CO2 at control did not prevent the fall in f and VT. The relation between VT and esophageal pressure or diaphragm electromyogram (EMG) did not change consistently, nor was the ratio of high to low frequencies in the diaphragm EMG altered. Carotid chemoreceptor discharge increased within 15 s, and at 5 min it was much above control. We conclude that the change in the breathing pattern in hypoxia is probably due to the activation of a central mechanism.  相似文献   

15.
Influence of airway resistance on hypoxia-induced periodic breathing.   总被引:2,自引:0,他引:2  
We studied the effects of changing upper airway pressure on the variability of the dynamic response of ventilation to a hypoxic disturbance in 11 spontaneously breathing dogs. Supralaryngeal pressure, instantaneous inspiratory flow, end-expiratory lung volume, and the inspiratory and expiratory O2 and CO2 concentrations were continuously recorded at baseline and after a 1.5-min hypoxic stimulus (abrupt normoxic recovery). Arterial blood gases were obtained at baseline, at the end of the hypoxic period, and after 1 min of recovery. Airway resistances were modified during the recovery by changing the composition of the inspired gas (all with an inspiratory O2 fraction of 20.9%) among four different trials: two trials were realized with air (density 1.12 g/l), and the other two were with He or SF6 (respective density 0.42 and 4.20) in random order. There was no difference between baseline minute ventilation, arterial blood gases, and supralaryngeal resistance values preceding the trials. The hypoxemic and hypocapnic levels and the hypoxia-induced hyperventilation reached during the hypoxic tests were identical for the different hypoxic stimuli. The supralaryngeal resistance measured at peak flow was dramatically influenced by the composition of the inspired gas: 8.8 +/- 1.8 and 6.9 +/- 1.7 (SE) cmH2O.l-1.s with air, 7.2 +/- 2.2 with He, 21.9 +/- 5.5 with SF6 (P less than 0.05). Ventilatory fluctuations were consistently seen during the posthypoxic period. They were characterized by a strength index value (M) (Waggener et al. J. Appl. Physiol. 56: 576-581, 1984).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Recent computed tomography studies show that inspired gas composition affects the development of anesthesia-related atelectasis. This suggests that gas absorption plays an important role in the genesis of the atelectasis. A mathematical model was developed that combined models of gas exchange from an ideal lung compartment, peripheral gas exchange, and gas uptake from a closed collapsible cavity. It was assumed that, initially, the lung functioned as an ideal lung compartment but that, with induction of anesthesia, the airways to dependent areas of lung closed and these areas of lung behaved as a closed collapsible cavity. The main parameter of interest was the time the unventilated area of lung took to collapse; the effects of preoxygenation and of different inspired gas mixtures during anesthesia were examined. Preoxygenation increased the rate of gas uptake from the unventilated area of lung and was the most important determinant of the time to collapse. Increasing the inspired O2 fraction during anesthesia reduced the time to collapse. Which inert gas (N2 or N2O) was breathed during anesthesia had minimal effect on the time to collapse.  相似文献   

17.
In the study of the physiological regulation of respiration through a control system model it is necessary to test the ventilatory response to various forcing functions of either the parrtial pressure of alveolar carbon dioxide (PACO2) or oxygen (PAO2). Since PACO2 and PAO2 are both functions of alveolar ventilation and metabolic rate, such a result cannot be obtained by merely changing the composition of the inspired gases without a feedback control. Thus a servomechanism is necessary. The input to the servomechanism is an instantaneous determination of PACO2 and PAO2. This is accomplished by using the criterion of equality of the exchange ratio in mean alveolar gas and mean expired gas. The servomechanism described has three essential characteristics: rapidity, accuracy, and stability. In experiments of step, ramp, and sinusoidal forcing functions, variations of PACO2 have been obtained without change in PAO2, and step variations of PAO2 have been obtained without change in PACO2.  相似文献   

18.
Alveolar exchange of a gas is governed by the ventilation-perfusion ratio (VA/Q) and the Ostwald partition coefficient for that species. We altered the Ostwald coefficients for O2 and CO2 by considering an animal breathing water or a fluorocarbon (FC-80) and studied the effects on gas exchange. Among our conclusions are the following. 1) When the ratio of the CO2 to O2 solubility in the inspirate exceeds the ratio of the O2 to the CO2 slope of the blood dissociation curve, as in water breathing, the VA/Q line becomes concave upward, and elements having a low VA/Q differ from each other more in terms of CO2 than of O2. 2) As the ratio of the CO2 to O2 solubility in the inspired medium increases, CO2 elimination becomes more dependent on perfusion. 3) At times, the same R will prevail in areas having different VA/Q values. 4) The alveolar-to-arterial O2 and CO2 differences resulting from a given VA/Q distribution do not depend on the O2 and CO2 solubility coefficients of the inspired medium, but on the inspired and mixed venous concentrations necessary to maintain adequate arterial gas levels in the presence of different inspired media.  相似文献   

19.
We applied high-frequency oscillatory ventilation (HFOV) of low amplitude to the pleural surface of the isolated rat lung (IPL) perfused at 10 ml X min-1 with Krebs bicarbonate containing 4.5% albumin (hematocrit 34%). Lung volume was held constant by a continuous positive airways pressure (CPAP) of 5 cmH2O. Varying CPAP from 2 to 15 cmH2O did not affect O2 uptake. Tidal volume (VT) was estimated with an impedance pneumograph, and it bore a direct linear relationship to the amplitude of both the loudspeaker input signal and the pressure change in the chamber up to 30 Hz; VT was inversely proportional to the frequency (f). However, at a constant loudspeaker input of 10 V, minute expired ventilation (VE) remained constant (mean 104 ml X min-1) as f increased from 5 to 30 Hz. Hemoglobin saturation increased by more than 80% during HFOV of 5-40 Hz and amplitude of 10 V, the maximum O2 uptake being 14.6 ml O2 per 100 ml perfusate. Whereas dead space was approximately 335 microliters, a VT of less than 40 microliters could effect normal O2 uptake, suggesting that bulk flow is playing only a minor role in gas exchange. HFOV for 60 min (CPAP 5 cmH2O) did not affect the amount of alveolar surfactant compared with conventional ventilation at the same mean airway pressure. We conclude that normal O2 uptake can be maintained by applying HFOV to the pleural surface of the IPL held at constant volume.  相似文献   

20.
Convective mixing in human respiratory tract: estimates with aerosol boli   总被引:1,自引:0,他引:1  
Convective gas mixing in the respiratory tract of 17 healthy male subjects was studied by an aerosol bolus technique. The monodisperse 1 micron di(2-ethylhexyl)sebacate droplets we used behaved as a nondiffusing gas. As the bolus was inspired to different depths and then expired, we measured the extent to which the bolus spread. We found that the deeper the bolus penetrated into the lungs, the more it became dispersed. The half-width of the expired bolus was a linear function of the volume to which the bolus penetrated at volumetric penetrations of 100-800 cm3. This suggests that convective mixing is not confined to central airways but can also occur in the lung periphery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号