首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
A sensitive plasma assay for acyclovir has been developed and validated. Acyclovir was separated from plasma components using Oasis HLB columns. Separation was obtained with no plasma interference using micellar electrokinetic chromatography (175 mM SDS) and hydroxypropyl-beta-cyclodextrin (100 mM) in 90 mM borate buffer (pH 8.8) containing 0.2% NaCl. High sensitivity was achieved by large volume sample introduction and stacking. The linear range was from 20 to 10000 ng/ml with a limit of quantitation of 20 ng/ml. This method is a viable alternative to HPLC because of its high separation and sensitivity, reproducibility, and adaptability to other nucleoside analogs.  相似文献   

2.
A high-performance micellar electrokinetic capillary chromatography (MEKC) has been demonstrated for the determination of meropenem in human plasma and in cerebrospinal fluid (CSF) and application in meningitis patients after intravenous (IV) administration. Plasma sample was pretreated by means of solid-phase extraction (SPE) on C(18) cartridge and CSF sample was by direct injection without sample pretreatment, with subsequent quantitation by MEKC. The separation of meropenem was carried out in an untreated fused-silica capillary (40.2 cm x 50 microm I.D., effective length 30 cm) and was performed at 25 degrees C using a background electrolyte consisting of Tris buffer (40 mM, pH 8.0) solution with sodium dodecyl sulfate (SDS) as the running buffer and on-column detection at 300 nm. Several parameters affecting the separation and sensitivity of the drug were studied, including pH, the concentrations of Tris buffer and surfactant. Using cefotaxime as an internal standard (IS), the linear ranges of the method for the determination of meropenem in plasma and in CSF were all over 0.5-50 microg/mL; the detection limits (signal-to-noise ratio=3) of meropenem in plasma and in CSF were 0.2 microg/mL and 0.3 microg/mL, respectively.  相似文献   

3.
A rapid and sensitive capillary electrophoretic method for the determination of idarubicin and its metabolite idarubicinol in plasma has been developed and validated. Plasma is extracted by liquid-liquid extraction using chloroform. Idarubicin, idarubicinol and the internal standard daunorubicin can be separated in less than 5 min using a phosphate buffer of pH 5 with 70% acetonitrile. Laser-induced fluorescence detection with an Ar ion laser operated at 488 nm provides a sensitive and selective detection method without interferences from biological fluids. The small sample volume of 100 μl is of particular advantage for studies in pediatric oncology. The reproducibility of the method has been shown to be sufficient for drug monitoring or pharmacokinetic studies. The limit of quantification for idarubicin in plasma is 0.5 ng/ml.  相似文献   

4.
A capillary zone electrophoresis method for the separation and analysis of nitrate and nitrite in water and urine was developed. No interference in the electropherogram from other anions is observed by using a polyacrylamide-coated column with a modified phosphate buffer at pH 3 for the separation, and UV absorption at 214 nm for the detection. The method does not require sample pretreatment or the use of organic solvents. The limit of detection for each analyte (S/N = 3), using a 75 μm I.D. capillary, is 0.5 μg/ml. Urine samples require 40-fold dilution in order to maintain migration time reproducibility to within 1% relative standard deviation.  相似文献   

5.
A simple, rapid and sensitive method has been developed and validated for the analysis of a mixed-backbone oligonucleotide (GEM 231) in tumor tissues. The analysis was performed using a capillary electrophoresis (CE) system with UV detection. An extended light path (bubble cell) capillary column of 64.5 cm (effective length 56 cm)×50 μm I.D. is used as the separation column. The optimized chromatographic conditions were background electrolyte: sodium borate buffer (60 mM, pH 9.1), electrokinetic injection: 10 s, applied voltage: 30 kV, detection at λ=210 nm. A linear relationship was observed between the peak area and the amount of GEM 231 in the range of 1.0–1000 μg/ml. The lower detection limit of the drug was 100 pg with an average recovery of about 75±5%. The inter-day and intra-day relative standard deviations were <10%. Assay validation studies revealed that CE method is reproducible and specific for the determination of GEM 231 in tissue homogenates with a run time of less than 5 min.  相似文献   

6.
Enantioselective separation methods and the enantioselective determination of the anti-allergic drug azelastine and of three of its main phase I metabolites in a biological matrix underwent chromatographic and electrophoretic investigations. An enantioselective assay of a coupling of HPLC using a beta-cyclodextrin chiral stationary phase to ionspray tandem mass spectrometry is presented. Additionally, this assay is compared to another enantioselective assay using electrokinetic capillary chromatography with beta-cyclodextrin and carboxymethyl-beta-cyclodextrin in polyacrylamide-coated capillaries. For capillary electrophoresis (CE) the importance of polyacrylamide coating for the validation of this separation method is highlighted. Extracted rat plasma samples of enantioselective metabolism studies were measured by both validated assays. Differences in the pharmacokinetics and pharmacodynamics were evaluated for the main substance azelastine and its main metabolite demethylazelastine. So, a first hint about the enantioselectivity of biotransformation of azelastine in rats was seen after oral application of either enantiomer or the racemate to rats.  相似文献   

7.
A micellar electrokinetic capillary electrophoresis (MEKCE) method for the determination of cholic acid (CA), hyodeoxycholic acid (HDCA) and chenodeoxycholic acid (CDCA) in artificial Calculus Bovis and its four medicinal preparations is described. The buffer solution consisted of 40 mM disodic phosphate and 40 mM sodium dodecylsulfate (SDS) adjusted to pH 9.0. UV detection was set to 200 nm. Under optimum conditions, the analytes were baseline separated within 11min. The linear calibration range was 12.1-970 microgml(-1) for CA and 18.8-950 microgml(-1) for HDCA and CDCA, respectively. It was found that overall recoveries were within the range of 98-102%, and R.S.D.s were less than 5% for the analytes. This method, due to its convenience, high accuracy and good reproducibility can be employed in quality control of artificial Calculus Bovis and its medicinal preparations.  相似文献   

8.
A method for the separation of a mixture of opiates comprising pholcodine, 6-monoacetylmorphine, morphine, heroin, codeine and dihydrocodeine by capillary electrophoresis using a running buffer of 100 mM disodium hydrogenphosphate at pH 6 is described. The characteristics of an analytical method based on this separation for the determination of these drugs following extraction from urine and using levallorphan as internal standard are reported. Detection limits in the region of 10 ng cm−3 are achieved when using electrokinetic injection. A comparison is made of the sensitivity and reproducibility of electrokinetic and hydrodynamic injection for these drugs. Data are presented to show the results obtained when the proposed method is applied to urine spiked with all the above opiates and also to urine from a subject following consumption of dihydrocodeine and pholcodine. The concentrations found are compared with those obtained by LC.  相似文献   

9.
A micellar electrokinetic capillary chromatographic method to separate prednisolone, prednisolone acetate, naphazoline, Zn-bacitracin, sulfacetamide and phenylefrine is described. The separation was carried out by using a fused-silica capillary (57 cmx75 micrometer I.D.) at 25 degrees C and 30 kV, using a 5 mM phosphate-5 mM borate buffer adjusted to pH 8.2, 50 mM sodium dodecyl sulfate (SDS) and 10% methanol-water (v/v) as background electrolyte. Under these conditions, the run time was 8 min and the limits of quantification were about 1.0 mg/l for every component. The method was applied to pharmaceutical preparations and the results provided recoveries close to 100% and the method gave good results when compared with a reference multivariate calibration spectrophotometric method.  相似文献   

10.
This work aimed to develop a chiral separation method of ketoconazole enantiomers using electrokinetic chromatography. The separation was achieved using heptakis (2, 3, 6‐tri‐O‐methyl)‐β‐cyclodextrin (TMβCD), a commonly used chiral selector (CS), as it is relatively inexpensive and has a low UV absorbance in addition to an anionic surfactant, sodium dodecyl sulfate (SDS). The influence of TMβCD concentration, phosphate buffer concentration, SDS concentration, buffer pH, and applied voltage were investigated. The optimum conditions for chiral separation of ketoconazole was achieved using 10 mM phosphate buffer at pH 2.5 containing 20 mM TMβCD, 5 mM SDS, and 1.0% (v/v) methanol with an applied voltage of 25 kV at 25 °C with a 5‐s injection time (hydrodynamic injection). The four ketoconazole stereoisomers were successfully resolved for the first time within 17 min (total analysis time was 28 min including capillary conditioning). The migration time precision of this method was examined to give repeatability and reproducibility with RSDs ≤5.80% (n =3) and RSDs ≤8.88% (n =9), respectively. Chirality 27:223–227, 2015. © 2014 Wiley Periodicals, Inc.  相似文献   

11.
Data presented in this paper show that bromhexine and its pharmacologically active metabolite can easily be determined by capillary zone electrophoresis. The composition of the running buffer had a significant effect on the reproducibility of the migration time for which a carrier solution containing 30 mM phosphate buffer (pH 3.0), 5 M urea and 10% (v/v) acetonitrile was used. The method was validated with respect to its response linearity and reproducibility. The method is suitable for the determination of bromhexine and ambroxol in several samples such as pharmaceuticals, urine and serum. Photodiode-array detection permitted the rapid identification of both drugs in the sample analyzed.  相似文献   

12.
A capillary electrophoresis method was described for the determination of metformin in human plasma based on the extraction of the ion-pair with bromothymol blue into chloroform. Phenformin was used as internal standard. Field-amplified sample stacking injection was employed with an electrokinetic injection voltage of 10 kV for 10 s. The running buffer was 0.1 M phosphate buffer (pH 2.5), running voltage was 20 kV and the UV absorbance detection was set at 195 nm. The limit of quantitation was 0.25 μg/ml. Linearity range of calibration curve was 0.25 to 3.5 μg/ml. Recoveries for three levels (0.25, 1 and 2 μg/ml) were 80.24%, 67.44% and 58.97% (n=5 for each level), respectively. The intra-day precisions for the three levels were 11.9%, 3.09% and 4.33% and the inter-day precisions were 12.4%, 4.57% and 4.94%, respectively. The concentrations of metformin hydrochloride in human plasma of eight volunteers were measured after orally administrating metformin enteric-capsule and tablet.  相似文献   

13.
A modified capillary electrophoretic method for the determination of nitric oxide correlated nitrate in several tissue homogenates is described in this study. The method was developed using a running buffer consisting of 200 mM lithium chloride and 10 mM borate buffer at pH 8.5, in a fused-silica column total 82 cm, effective 43 cm length and 75 μm I.D. The signal was measured at 214 nm and controlled current of 200 μA (equivalent to 12.7 kV) was applied in the reversed polarity direction. The sample was injected by vacuum pressure 50 ms (25 nl). In these conditions, bromide as internal standard and nitrate appeared at 7.2 and 8.9 min, respectively. Whole validation procedures were applied and satisfactory results were obtained. The nitrate levels of the tissue homogenates of control and -NAME applied (heart, brain, kidney, stomach, lung, testis and liver) were monitored by the present method and it was decided that the method is precise and accurate.  相似文献   

14.
A new capillary electrophoresis (CE) method was developed and validated for the screening of human urine for nineteen drugs of abuse. In order to achieve sufficient separation, the electrolyte composition was modified using beta-cyclodextrin (beta-CD) and organic solvents. To process each sample, a sequential injection-solid-phase extraction (SI-SPE) system was constructed. Using this device, matrix clean-up, extraction, and preconcentration of analytes were performed onto a C(18) cartridge. Optimal separation and detection were obtained using a background electrolyte consisting of 100mM phosphate adjusted to pH 6.0, with 20 mM beta-CD, 5% acetonitrile and 20% isopropanol. Electrokinetic injection was performed at 5 kV for 10s, separation voltage was 25 kV and column temperature was set to 25 degrees C. The separation was carried out in a 67.0 cm x 50 microm fused-silica capillary with UV detection at 214 nm. The combination of SI-SPE and sample stacking showed significant sensitivity enhancement with limits of detection in the range of 5-30 ng ml(-1). A validation study showed good reproducibility of both migration time (RSD=0.003-0.088%) and peak area (RSD=0.54-4.8%). Overall, this automated and miniaturized SI-SPE system provides a rapid, sensitive, and robust procedure for analysis; as well as minimizes sample and solvent consumption.  相似文献   

15.
An efficient and reliable micellar electrokinetic capillary chromatography (MEKC) method has been developed for the simultaneous determination of isoniazid (ISO) and pyridoxine hydrochloride (PYR) in pharmaceutical formulations. A chemometric two level full factorial design approach was used to search for the optimum conditions of separation. Three parameters were selected for this study: the buffer pH, the buffer concentration and sodium dodecyl sulphate (SDS) concentrations. Resolution, peak symmetry and analysis time were established as response. The two analytes were separated within 6 min with the optimized conditions: 50 mM borate buffer, 25 mM SDS pH 7.8, 35 degrees C, at 50 mbar 4s injection and 30 kV by using a fused silica capillary (72 cm effective length, 50 microm i.d.). The detection wavelength was set to 205 nm. Meloxicam was used as internal standard. The method was validated with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity and robustness. The detection limits of the method were 1.0 microg mL(-1) for ISO and 0.40 microg mL(-1) for PYR and the method was linear at least in the range of 3.0-100 microg mL(-1) for ISO and 1.0-100 microg mL(-1) for PYR with excellent correlation coefficients (0.9995 for ISO and 0.9998 for PYR). Relative standard deviations (R.S.D.s) of the described method ranged between 0.54 and 2.27% for intra-day precision and between 0.65 and 2.69% for inter-day precision. The developed method was applied to the tablet form of ISO and PYR-containing the pharmaceutical preparations and the data were compared with obtained from the standard addition method. No statistically significant difference was found.  相似文献   

16.
A simple and rapid capillary zone electrophoresis determination method with UV detection of grepafloxacin and clinafloxacin has been developed. The separation was performed in 35 mM borate-35 mM phosphate buffer solution (pH 8.6), containing 6% (v/v) of acetonitrile. Analyses were realised using fused-silica capillaries (57 cm length x 75 microm I.D.) and the operating conditions were: 15 kV applied voltage, 30 degrees C and detection at 279 nm. Piromidic acid was used as an internal standard. The linear concentration range of application was 1.0-120.0 microg ml(-1) for both compounds, with a detection limit of 0.2 microg ml(-1) for grepafloxacin and 0.3 microg ml(-1) for clinafloxacin. The analysis yielded good reproducibility (RSD between 3.37 and 1.74%). It was applied to the determination of grepafloxacin and clinafloxacin in human and rat urine samples. The method was validated using HPLC as a reference method. Recovery levels were between 94.5 and 103%.  相似文献   

17.
A capillary electrophoresis (CE) method has been developed and validated for separating the tetrapeptide H-Tyr-(D)Arg-Phe-Phe-NH2 and nine related substances. The method was developed using experimental design in a four-step procedure, in which eight variables were investigated in a total of 47 experiments. The preferred background electrolyte (BGE) consisted of 0.1M malonic acid at pH 2.5 with 7 mM heptakis(2,6-di-O-methyl)-beta-cyclodextrin (2,6-DM-beta-CD). The separation of H-Tyr-(D)Arg-Phe-Phe-NH2 and the related substances was accomplished within 15 min, with a resolution greater than 1.5 between all peaks. The method was then investigated with respect to its selectivity, linearity, precision, detection limit (LOD) and quantitation limit (LOQ). In addition, a system suitability test was performed and response factors were determined, essentially following International Conference of Harmonization guidelines for the validation of analytical methods. LOD and LOQ for the related substance H-Arg-Phe-NH2 were found to be 0.3 and 0.8 microg/ml, respectively, at a target H-Tyr-(D)Arg-Phe-Phe-NH concentration of 1mg/ml. The method performed well with respect to all of the validation parameters.  相似文献   

18.
A new micellar electrokinetic capillary chromatographic method has been developed to analyze the pharmaceutical preparations containing ternary combination of paracetamol (PAR), caffeine (CAF) and propyphenazone (PRO). Best results were obtained by using 20mM pH 9.0 borate buffer containing 30mM sodiumdodecylsulphate as the background electrolyte. Diflunisal (DIF) was used as internal standard (IS). The separation was performed through a fused silica capillary (50microm internal diameter, 44cm total length, 35.5cm effective length) at 25 degrees C with the application of 3s of hydrodynamic injection at 50mbar pressure and a potential of 29kV. Detection wavelength was 200nm. Under these conditions, the migration times were found to be 5.174min for PAR, 5.513min for CAF, 7.195min for DIF, and 9.366min for PRO. Linearity ranges for the method were determined as 2-200microgmL(-1) for PAR and CAF and 3-200microgmL(-1) for PRO. Limit of detections were found as 0.6microgmL(-1) for PAR and CAF and 0.8microgmL(-1) for PRO. According to the validation study, the developed method was proved to be accurate, precise, sensitive, specific, rugged and robust. Three pharmaceutical preparations, which are produced by different drug companies in Turkey, were analyzed by the developed method. One of the same preparations was also analyzed by the derivative ratio spectro zero-crossing spectrophotometric method reported in literature. No significant differences were found statistically.  相似文献   

19.
The micellar electrokinetic chromatographic (MEKC) separation of seven bisbenzylisoquinoline alkaloids has been developed. The effects of various separating factors were studied. Optimum separation was achieved using a buffer (pH 9.2) of 20 mM sodium borate and 20 mM sodium dihydrogen phosphate buffer containing 55 mM sodium cholate; the optimum voltage and injection time were 21 kV and 0.05 min, respectively. Highest peak efficiency was obtained when the analytes were dissolved in 10 mM sodium dodecyl sulphate as sample matrix for injection. The elution order of the bisbenzylisoquinoline alkaloids was related to their lipophilicity. The resolution, run time and detection limits of the MEKC method were compared with those of an HPLC method developed previously.  相似文献   

20.
A reversed-phase high-performance liquid chromatographic method has been developed and validated for the quantification of the novel anticancer drug Ecteinascidin 743 in human plasma. The sample pretreatment of the plasma samples involved a solid-phase extraction (SPE) on cyano columns. Propyl-p-hydroxybenzoate was added after the sample pretreatment to correct for variability in injection volumes. The separation was performed on a Zorbax SB-C18 column (75×4.6 mm I.D., particle size 3.5 μm) with acetonitrile–25 mM phosphate buffer, pH 5.0 (70:30, v/v) as the mobile phase. The flow-rate was 1.0 ml/min and the eluent was monitored at 210 nm. The accuracies and precisions of the assay fall within ±15% for all quality control samples and within ±20% for the lower limit of quantitation, which was 1.0 ng/ml using 500 μl of plasma. The overall recovery of the sample pretreatment procedure for Ecteinascidin 743 was 87.0±5.9%. The drug was found to be stable in human plasma at −30°C for at least 2 months. At room temperature Ecteinascidin 743 was stable in human plasma for 5 h at most.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号