首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Although ion exchange chromatography has been used in separating amino acids from mineral salts, quantitative recovery has not been possible for the basic amino acids or for subnanomole concentrations of amino acids.As an analytical tool for amino acid analysis, ion-exchange chromatography has made it possible to resolve a relatively complex mixture of amino acids in less than an hour with detection limits of less than 10–12 moles of amino acids. Reasonable specificity for amino acids is achieved by multiple wavelength detection of the reaction product found with ninhydrin. Unequivocal specificity must be obtained in conjunction with other methods such as mass spectrometry.In the analysis of subnanomole levels of amino acids, it is necessary to carry both reagent blanks and low-level amino acid standards through the entire sample preparation step since both contamination and selective losses occur and must be monitored.  相似文献   

2.
Nitric oxide (NO*) is a diatomic free radical which has recently been found to have a key role in both normal physiological processes and disease states. The presence of NO in biological systems leads to the formation of reactive nitrogen species (RNS) such as peroxynitrite which reacts avidly with tyrosine residues in proteins to form nitrotyrosine (NTYR). Since peroxynitrite has a very short half-life at neutral pH, the presence of NTYR has been used as a marker of RNS production in various tissues. A number of methods for separation, detection, and quantitation of NTYR in biological samples have been developed. These methods include immunochemical techniques such as immunhistochemistry, ELISA, and Western blotting, high-performance liquid chromatography (HPLC) in combination with various detection systems including UV and electrochemical detection (ECD), gas chromatography (GC), gas chromatography-mass spectrometry (GC-MS), and electrospray mass spectrometry. In terms of sensitivity and specificity, it would appear that methods based on combinations of HPLC and various types of ECD are very versatile giving a limit of detection of 20 fmol per injection of protein hydrolysate. They are only limited by the sample quantity and the preparation that is required to achieve acceptable chromatograms. In addition to the detection of NTYR as a marker of RNS, its role in biological systems may be more subtle with nitration of key tyrosine residues likely to profoundly affect cellular function such as signaling cascades. Further advances are likely to be made in the localization of NTYR residues in peptide fragments using mass spectrometry.  相似文献   

3.
A rapid and sensitive analytical method has been developed for the simultaneous determination of 16 non-steroidal anti-inflammatory drugs (NSAIDs) in human plasma by capillary liquid chromatography (LC) and quadrupole mass spectrometry with electrospray ionization operated in the negative ion mode. The sample clean-up and enrichment on a pre-column were accomplished on-line to improve the sensitivity. This method greatly reduced sample preparation time and sample volume compared with off-line sample extraction methods and conventional LC methods, respectively. The recoveries of NSAIDs from human plasma were 56.7-96.9%. The total analytical time for a single analytical run was approximately 15 min. The detection limits of NSAIDs were 0.001-0.075 microg ml(-1) using a selected ion monitoring mode.  相似文献   

4.
Analytical methods to determine phytoestrogenic compounds   总被引:1,自引:0,他引:1  
The analytical methods for the determination of phytoestrogenic compounds in edible plants, plant products and biological matrices are reviewed. The detection, qualitative and quantitative methods based on different chromatographic separations of gas chromatography (GC), high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) coupled with various detections by ultraviolet absorption (UV), electrochemical detection (ED), fluorescence detection, mass spectrometry (MS) and nuclear magnetic resonance spectroscopy (NMR), as well as non-chromatographic immunoassay are each extensively examined and compared. An overview on phytoestrogen chemistry, bioactivities and health effects, plant precursors, metabolism and sample preparation is also presented.  相似文献   

5.
Polyclonal antibodies with high specificity for C1-immobilised (+)-cis,trans-abscisic acid (ABA) were raised, characterised by enzyme-linked immunosorbent assay (ELISA) and used for preparation of an immunoaffinity chromatography (IAC) gel. The detection limit of the ELISA was approximately 4.6x10(-10)mol/L. Sensitive electrospray liquid chromatography-mass spectrometry (LC-ESI-MS) methods were also developed with detection limits below 0.1x10(-12)mol. The IAC allowed quick, single-step processing of samples prior to the analyses. The LC-ESI-MS and LC-ELISA techniques were used for comparative estimation of endogenous ABA levels in immunoaffinity purified extracts of normal and water-stressed Nicotiana tabacum L. leaves. The analytical approaches were validated using deuterium- and tritium-labelled internal standards, respectively. The IAC method was found to be highly effective, sensitive and convenient for isolating the target analyte from plant material.  相似文献   

6.
This report describes the use of FRIT fast atom bombardment (FAB) liquid chromatography/mass spectrometry for the analysis of acetylcholine in rat brain regions. Direct assessment of acetylcholine levels is possible without the need for either derivatization or extensive sample preparation. Quantification is accomplished by monitoring intact molecular cations of acetylcholine and a deuterated internal standard. The results are compared with those obtained by conventional pyrolysis gas chromatography/mass spectrometry and by liquid chromatography with electrochemical detection.  相似文献   

7.
The analysis of antimalarials by high-performance liquid chromatography (HPLC)/mass spectrometry demonstrates a new dimension in specificity along with increased sensitivity compared to conventional HPLC detection methods. Both direct liquid introduction and thermospray HPLC/mass spectrometry interfaces provided molecular weight information as well as characteristic fragment ions for antimalarials not normally amenable to direct probe or gas chromatographic/mass spectrometric techniques. The direct liquid introduction interface, which incorporated a 1/100 split, showed a detection limit of 30 ng using selected ion monitoring. The thermospray technique showed less than 1 ng detection limits using selected ion monitoring.  相似文献   

8.
Therapeutic drug monitoring can involve quantitation in either microgram, nanogram or picogram concentrations present in a complex biological matrix (whole blood, urine or tissue).The chemical structure of a compound influences not only the analytical method best suited to its quantitation, but also its acid/base character (PKa) and its extractability. The dose administered, the bioavailability of the dosage form, and the pharmacokinetic profile of the drug govern the circulating concentrations of either the parent drug and/or its metabolites present in vivo, and dictate the ultimate sensitivity and specificity required of the analytical method.The degree of sample preparation required is dependent on the analytical method used (gas—liquid chromatography, thin-layer chromatography, high-performance liquid chromatography) and on the tolerance of the specific type of detection system to contamination. Factors leading to compound losses during sample preparation (adsorption, stability) are critical at low concentrations and can adversely affect the reliability of an assay, therefore maximizing the overall recovery of the assay is essential not only for high sensitivity but also for good precision and accuracy. Therefore, the criteria to be used in sample preparation should aim to optimize all of the above factors in the overall development of a reliable and validated method for the compound suitable for use in clinical therapeutic monitoring.  相似文献   

9.
Metalloproteinase inhibitors are being explored for the treatment of a wide variety of human diseases including cancers, arthritis, cardiovascular disorders, human immunodeficiency virus infection, and central nervous system illnesses. This review provides an overview of various analytical sample preparation, separation, detection, and identification techniques employed for the quantitative and qualitative determination of these inhibitor compounds. Special emphasis is placed on biological sample preparation by automated solid-phase extraction, liquid–liquid extraction, and protein precipitation by centrifugation or filtration. Other sample preparation methodologies are also evaluated. Applications of high-performance liquid chromatography, gas chromatography, and capillary electrophoresis to the quantitative determination of metalloproteinase inhibitors are described. Examples of qualitative analysis of metalloproteinase inhibitors by hyphenated liquid chromatography with mass spectrometry and nuclear magnetic resonance are also presented. The advantages and limitations of these separation and identification methodologies as well as other less frequently employed techniques are assessed and discussed.  相似文献   

10.
This article reviews the analysis of 31 drugs and drug metabolites in human hair by thin-layer chromatography, high-performance liquid chromatography, gas chromatography, gas chromatography—mass spectrometry and mass spectrometry. The most important detection method after chromatographic separation of the components is the mass spectrometry because of its sensitivity and specifity. Washing steps to exclude external contamination, extraction, derivatization, stationary phases, detection modes and detection limits of the mass spectrometric and gas chromatographic-mass spectrometric procedures are presented in five tables. Additionally, a method for a gas chromatographic-mass spectrometric screening procedure is presented.  相似文献   

11.
A simple, derivatization free method for the direct determination of dimethylsulfoniopropionate (DMSP) using hydrophilic interaction liquid chromatography (HILIC)/mass spectrometry is introduced. DMSP is a zwitterionic osmolyte which is produced from marine plankton, macro algae and higher plants. Due to its central role in climate relevant geochemical processes as well as in plant physiology and chemical ecology there is a great interest in methods for its quantification. Since DMSP is labile and difficult to extract currently most protocols for quantification are based on indirect methods. Here we show that ultra performance liquid chromatography/mass spectrometry using a HILIC stationary phase is suitable for the direct quantification of DMSP from aqueous samples and microalgal extracts. The protocol requires minimal sample preparation and phytoplankton samples can be investigated after filtration of small volumes. The limit of detection is 20nM and the calibration curve is linear in the range of 60nM to 50μM. The use of [(2)H(6)]-DMSP as internal standard allows prolonged sample storage since it is transformed with the same kinetics as natural DMSP. This makes the method suitable for both laboratory and field studies.  相似文献   

12.
United States Pharmacopeia updated its 100 years old metal analysis method with inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). These sensitive instruments require that sample preparation be at least as sophisticated as the instrumentation used in the analysis. Sample contamination during sample preparation has to be controlled to an acceptable level given the low detection limit of these instruments and the ubiquitous presence of elements. This article focused on sample contamination during sample preparation. Contaminations from environment, reagents, and lab apparatus were investigated for their impact on trace element analysis. Advice on clean lab practice was offered to the pharmaceutical industry in regard to contamination control in elemental analysis labs at a time when the industry is preparing for compliance with elemental impurities in drug products.  相似文献   

13.
A review of chromatographic methods for the determination of 2,3-benzodiazepines (2,3-BZs) is presented. The determinations are performed to investigate the presence of potential impurities in drug substances and to study their pharmacokinetic profile in biological samples, either in animals or in humans. Several methods dealt with a pretreatment of samples, i.e., liquid–liquid extraction by using a variety of solvents, solid-phase extraction, direct injection of specimens into the chromatographic apparatus. Different chromatographic techniques have been used. High-performance liquid chromatography allows optimal sensitivity and specificity by using ultraviolet or diode array detection methods. Gas chromatography-mass spectrometry and gas chromatography with nitrogen-phosphorous or electron-capture detectors have been also reported. Suitable methods for the separation of enantiomers of 2,3-BZs have been described. Thin-layer chromatography has been shown to be capable to isolate analytes from biological samples as urine or faeces. The reported chromatographic techniques are currently applied to define the metabolic pathways of 2,3-BZs in experimental and clinical studies.  相似文献   

14.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   

15.
Atomoxetine is the first, non-stimulant alternative to other stimulant medications used for the treatment of Attention-Deficit/Hyperactivity Disorder (ADHD). Reported methods for the determination of atomoxetine include expensive liquid chromatography tandem mass spectrometry (LCMS) and high performance liquid chromatography (HPLC) with liquid scintillation counting (LSC) detection. Till date, no method has been reported in literature to determine atomoxetine using HPLC with UV detection. In this paper, we describe a new HPLC method for the determination of atomoxetine using liquid-liquid extraction with tertiary butyl methyl ether and UV detector. This method was found to be linear over the concentration range of 0.05-3.0 microg/ml. The limit of quantification was 0.05 microg/ml. Intra- and inter-day precision was <15% and accuracy was in the range of 95.67-108.80%. Stability studies showed that atomoxetine was stable in human plasma for short- and long-term period for sample preparation and analysis. This method was used for sample analysis in a pharmacokinetic study of atomoxetine (25mg) in five healthy adult female volunteers. The observed mean+/-S.D. pharmacokinetic parameters Cmax, Tmax and AUC(0-t) were 0.40+/-0.06 microg/ml, 3.40+/-0.42 h and 1.34+/-0.52 microg h/ml, respectively.  相似文献   

16.
《Free radical research》2013,47(4):531-540
Abstract

The analysis of oxidized nucleic acid metabolites can be performed by a variety of methodologies: liquid chromatography coupled with electrochemical or mass-spectrometry detection, gas chromatography coupled with mass spectrometry, capillary electrophoresis and ELISA (Enzyme-linked immunosorbent assay). The major analytical challenge is specificity. The best combination of selectivity and speed of analysis can be obtained by liquid chromatography coupled with tandem mass spectrometric detection. This, however, is also the most demanding technique with regard to price, complexity and skills requirement. The available ELISA methods present considerable specificity problems and cannot be recommended at present. The oxidized nucleic acid metabolites in urine are assumed to originate from the DNA and RNA. However, direct evidence is not available. A possible contribution from the nucleotide pools is most probably minimal, if existing. Recent investigation on RNA oxidation has shown conditions where RNA oxidation but not DNA oxidation is prominent, and while investigation on DNA is of huge interest, RNA oxidation may be overlooked. The methods for analyzing oxidized deoxynucleosides can easily be expanded to analyze the oxidized ribonucleosides. The urinary measurement of oxidized nucleic acid metabolites provides a non-invasive measurement of oxidative stress to DNA and RNA.  相似文献   

17.
The analysis of oxidized nucleic acid metabolites can be performed by a variety of methodologies: liquid chromatography coupled with electrochemical or mass-spectrometry detection, gas chromatography coupled with mass spectrometry, capillary electrophoresis and ELISA (Enzyme-linked immunosorbent assay). The major analytical challenge is specificity. The best combination of selectivity and speed of analysis can be obtained by liquid chromatography coupled with tandem mass spectrometric detection. This, however, is also the most demanding technique with regard to price, complexity and skills requirement. The available ELISA methods present considerable specificity problems and cannot be recommended at present. The oxidized nucleic acid metabolites in urine are assumed to originate from the DNA and RNA. However, direct evidence is not available. A possible contribution from the nucleotide pools is most probably minimal, if existing. Recent investigation on RNA oxidation has shown conditions where RNA oxidation but not DNA oxidation is prominent, and while investigation on DNA is of huge interest, RNA oxidation may be overlooked. The methods for analyzing oxidized deoxynucleosides can easily be expanded to analyze the oxidized ribonucleosides. The urinary measurement of oxidized nucleic acid metabolites provides a non-invasive measurement of oxidative stress to DNA and RNA.  相似文献   

18.
The identification of new contaminants is critical in the development of new medicinal products. Many impurities, such as pentanedioic acid, hexanedioic acid, heptanedioic acid, octanedioic acid, decanedioic acid, undecanedioic acid, dodecanedioic acid, tridecanedioic acid, and tetradecanedioic acid, have been identified in samples of azelaic acid. The aim of this study was to identify impurities observed during the stability tests of a new liposomal dosage form of azelaic acid that is composed of phosphatidylcholine and a mixture of ethyl alcohol and water, using high-performance liquid chromatography with evaporative light-scattering detector (HPLC-ELSD), gas chromatography–flame ionisation detection (GC-FID), and gas chromatography–mass spectrometry (GC-MS) methods. During the research and development of a new liposomal formulation of azelaic acid, we developed a method for determining the contamination of azelaic acid using HPLC-ELSD. During our analytical tests, we identified a previously unknown impurity of a liposomal preparation of azelaic acid that appeared in the liposomal formulation of azelaic acid during preliminary stability studies. The procedure led to the conclusion that the impurity was caused by the reaction of azelaic acid with one of the excipients that was applied in the product. The impurity was finally identified as an ethyl monoester of azelaic acid. The identification procedure of this compound was carried out in a series of experiments comparing the chromatograms that were obtained via the following chromatographic methods: HPLC-ELSD, GC-FID, and GC-MS. The final identification of the compound was carried out by GC with MS.  相似文献   

19.
An improved method of detection of the isoflavone aglycones, genistein and daidzein, is reported using solid-phase microextraction–high-performance liquid chromatography–electrospray ionization mass spectrometry (SPME–HPLC–ESI-MS). Extraction of the isoflavonoids from urine using SPME with a Carbowax–templated resin fiber coating allows rapid preconcentration of the analytes without the usual sample preparation required by other methods. Detection of the analytes is accomplished by HPLC–ESI-MS. Analysis of spiked samples of urine resulted in a linear range of 0.25 to 250 ng/ml for daidzein and 0.27 to 27.0 ng/ml for genistein. Limits of detection of daidzein and genistein were measured at 25.4 pg/ml for daidzein and 2.70 pg/ml for genistein. Daidzein and genistein were detected in urine following consumption of a soy drink.  相似文献   

20.
An automated approach for the rapid analysis of protein structure has been developed and used to study acid-induced conformational changes in human growth hormone. The labeling approach involves hydrogen/deuterium exchange (H/D-Ex) of protein backbone amide hydrogens with rapid and sensitive detection by mass spectrometry (MS). Briefly, the protein is incubated for defined intervals in a deuterated environment. After rapid quenching of the exchange reaction, the partially deuterated protein is enzymatically digested and the resulting peptide fragments are analyzed by liquid chromatography mass spectrometry (LC-MS). The deuterium buildup curve measured for each fragment yields an average amide exchange rate that reflects the environment of the peptide in the intact protein. Additional analyses allow mapping of the free energy of folding on localized segments along the protein sequence affording unique dynamic and structural information. While amide H/D-Ex coupled with MS is recognized as a powerful technique for studying protein structure and protein–ligand interactions, it has remained a labor-intensive task. The improvements in the amide H/D-Ex methodology described here include solid phase proteolysis, automated liquid handling and sample preparation, and integrated data reduction software that together improve sequence coverage and resolution, while achieving a sample throughput nearly 10-fold higher than the commonly used manual methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号