相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have determined the resistance (Rrs) and the reactance (Xrs) of the total respiratory system in unsedated spontaneously breathing calves at various frequencies. A pseudorandom noise pressure wave was produced at the nostrils of the animals by means of a loudspeaker adapted to the nose by a tightly fitting mask. A Fourier analysis of the pressure in the nostrils and flow signals yielded mean Rrs and Xrs, over 16 s, at frequencies of 2-26 Hz. A good correlation was found between values of pulmonary resistances measured by the isovolume method at the respiratory frequency of animals and values obtained at a frequency of 6 Hz by use of our technique. The linearity of the respiratory system, the reproducibility of the technique, and the effects of upper airways on results have been studied. In healthy calves, Rrs increases with frequency. Mean resonant frequency is 7.5 Hz. Bronchospasm was induced in six calves by administration of intravenous organophosphates. Rrs tended to decrease with increasing frequency. Resonant frequency exceeded 26 Hz. All parameters returned to initial values after administration of atropine. In healthy calves, atropine produces a decrease in Rrs, especially at low frequencies. Values of resonant frequency are not modified.  相似文献   

2.
Dependences of the mechanical properties of the respiratory system on frequency (f) and tidal volume (VT) in the normal ranges of breathing are not clear. We measured, simultaneously and in vivo, resistance and elastance of the total respiratory system (Rrs and Ers), lungs (RL and EL), and chest wall (Rcw and Ecw) of five healthy anesthetized paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz) delivered at a constant mean lung volume. Each dog showed the same f and VT dependences. The Ers and Ecw increased with increasing f to 1 Hz and decreased with increasing VT up to 200 ml. Although EL increased slightly with increasing f, it was independent of VT. The Rcw decreased from 0.2 to 2 Hz at all VT and decreased with increasing VT. Although the RL decreased from 0.2 to 0.6 Hz and was independent of VT, at higher f RL tended to increase with increasing f and VT (i.e., as peak flow increased). Finally, the f and VT dependences of Rrs were similar to those of Rcw below 0.6 Hz but mirrored RL at higher f. These data capture the competing influences of airflow nonlinearities vs. tissue nonlinearities on f and VT dependence of the lung, chest wall, and total respiratory system. More specifically, we conclude that 1) VT dependences in Ers and Rrs below 0.6 Hz are due to nonlinearities in chest wall properties, 2) above 0.6 Hz, the flow dependence of airways resistance dominates RL and Rrs, and 3) lung tissue behavior is linear in the normal range of breathing.  相似文献   

3.
We evaluated the effect of pulmonary edema on the frequency (f) and tidal volume (VT) dependences of respiratory system mechanical properties in the normal ranges of breathing. We measured resistance and elastance of the lungs (RL and EL) and chest wall of four anesthetized-paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz), delivered at a constant mean airway pressure. Measurements were made before and after severe pulmonary edema was produced by injection of 0.06 ml/kg oleic acid into the right atrium. Chest wall properties were not changed by the injection. Before oleic acid, EL increased slightly with increasing f in each dog but was independent of VT. RL decreased slightly and was independent of VT from 0.2 to 0.4 Hz, but above 0.4 Hz it tended to increase with increasing flow, presumably due to the airway contribution. After oleic acid injection, EL and RL increased greatly. Large negative dependences of EL on VT and of RL on f were also evident, so that EL and RL after oleic acid changed two- and fivefold, respectively, within the ranges of f and VT studied. We conclude that severe pulmonary edema changes lung properties so as to make behavior VT dependent (i.e., nonlinear) and very frequency dependent in the normal range of breathing.  相似文献   

4.
As we previously reported, resonant frequency heart rate variability biofeedback increases baroreflex gain and peak expiratory flow in healthy individuals and has positive effects in treatment of asthma patients. Biofeedback readily produces large oscillations in heart rate, blood pressure, vascular tone, and pulse amplitude via paced breathing at the specific natural resonant frequency of the cardiovascular system for each individual. This paper describes how resonance properties of the cardiovascular system mediate the effects of heart rate variability biofeedback. There is evidence that resonant oscillations can train autonomic reflexes to provide therapeutic effect. The paper is based on studies described in previous papers. Here, we discuss the origin of the resonance phenomenon, describe our procedure for determining an individual's resonant frequency, and report data from 32 adult asthma patients and 24 healthy adult subjects, showing a negative relationship between resonant frequency and height, and a lower resonant frequency in men than women, but no relationship between resonant frequency and age, weight, or presence of asthma. Resonant frequency remains constant across 10 sessions of biofeedback training. It appears to be related to blood volume.  相似文献   

5.
Total respiratory resistance and reactance from 4 to 52 Hz were determined by the method of forced pseudorandom noise oscillation in 20 normal male subjects before and after inhalation of 0.200 mg salbutamol (albuterol) and before and after the subjects were equilibrated with 80% He-20% O2. During air breathing, there was a statistically significant decrease of resistance values at lower frequencies after inhalation of salbutamol. When the subject was equilibrated with 80% He-20% O2, total respiratory resistance markedly decreased at all frequencies, and a negative frequency dependence of resistance was observed between 8 and 20 Hz. Resistance values further decreased during He-O2 breathing after inhalation of salbutamol. After inhalation of salbutamol, reactance values increased during air and He-O2 breathing. The density-dependent decrease of the real part of impedance can be explained by a decrease of turbulence in the larger airways. The bronchodilating effect of salbutamol was not influenced by a change in the physical properties of the inhaled gas. During He-O2 breathing, reactance values significantly decreased, resulting in an increase of resonant frequency due to a decrease of inductive reactance. It is concluded that an increase in the capacitance of the respiratory system must be supposed to explain the increase in reactance values after inhalation of the beta-adrenergic agonist salbutamol.  相似文献   

6.
7.
A gas sampling device is described for continuous monitoring of respiratory gas composition that is applicable to experimental conditions when the breathing frequency is very high (greater than 2 Hz) and the response time of conventional gas analyzers becomes a critical limiting factor. The system utilizes the principle of discontinuous gas collection at any selected point of the respiratory cycle facilitated by ultraspeed piezoelectric valves and includes provision for sample-hold characteristics. Two distinct modes of operation are supported. In phase-locked mode gas sampling is synchronous with breathing frequency. In scanning mode gas collection is asynchronous with breathing frequency. Phase-locked mode may be used for continuous monitoring of end-tidal gas concentrations, whereas scanning mode is intended for assessing the gas concentration profile throughout the respiratory cycle. The system may be applied to steady breathing encountered in mechanical ventilation at high frequency or during quasi-steady breathing observed in panting animals. Combined with a respiratory mass spectrometer, the system has been used for measurement of gas concentrations in alveolar gas mixtures at breathing frequencies ranging from 3 to 30 Hz that were otherwise not amenable to rapid measuring techniques.  相似文献   

8.
Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors of 4mm(2) sensing area were immobilized with antibody specific to Bacillus anthracis (anti-BA) spores or bovine serum albumin (anti-BSA). Detection of pathogen (Bacillus anthracis (BA) at 300 spores/mL) and BSA (1 mg/mL) were investigated under both stagnant and flow conditions. Two flow cell designs were evaluated by characterizing flow-induced resonant frequency shifts. One of the flow cells labeled SFC-2 (hold-up volume of 0.3 mL), showed small fluctuations (+/-20 Hz) around a common resonant frequency response of 217 Hz in the flow rate range of 1-17 mL/min. The total resonant frequency change obtained for the binding of 300 spores/mL in 1h was 90+/-5 Hz (n=2), and 162+/-10 Hz (n=2) under stagnant and flow conditions, respectively. Binding of antibodies, anti-BA and anti-BSA, were more rapid under flow than under stagnant conditions. The sensor was repeatedly exposed to BSA with an intermediate release step. The first and second responses to BSA were nearly identical. The total resonant frequency response to BSA was 388+/-10 (n=2) Hz under flow conditions. Kinetic analysis is carried out to quantify the effect of flow rate on antibody immobilization and the two types of detection experiments.  相似文献   

9.
For respiratory system impedance (Zrs), the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956) suggests three resonant frequencies (f1,f2,f3), where f1 is the result of the sum of tissue and airway inertances and tissue compliance and f2 is the result of alveolar gas compression compliance (Cg) and tissue inertance (Iti). Three such resonant frequencies have been reported in humans. However, the parameter estimates resulting from fitting this model to the data suggested that f2 and f3 were not associated with Cg and Iti but with airway acoustic properties. In the present study, we measured Zrs between 5 and 320 Hz in 10 healthy adult humans breathing room air or 80% He-20% O2 (HeO2) to gain insight as to whether airway or tissue properties are responsible for the f2 and f3. When the subjects breathed room air, f2 occurred at 170 +/- 16 (SD) Hz, and when they breathed HeO2 it occurred at 240 +/- 24 Hz. If this resonance were due to Cg and Iti it should not have been affected to this extent by the breathing of HeO2. We thus conclude that f2 is not due to tissue elements but that it is an airway acoustic resonance. Furthermore, application of the six-element model to analyze Zrs data at these frequencies is inappropriate, and models incorporating the airway acoustic properties should be used. One such model is based on the concept of equivalent length, which is defined as the length of an open-ended, cylindrical tube that has the same fundamental acoustic resonant frequency.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
We studied the influence of three types of breathing [spontaneous, frequency controlled (0.25 Hz), and hyperventilation with 100% oxygen] and apnea on R-R interval, photoplethysmographic arterial pressure, and muscle sympathetic rhythms in nine healthy young adults. We integrated fast Fourier transform power spectra over low (0.05-0.15 Hz) and respiratory (0.15-0.3 Hz) frequencies; estimated vagal baroreceptor-cardiac reflex gain at low frequencies with cross-spectral techniques; and used partial coherence analysis to remove the influence of breathing from the R-R interval, systolic pressure, and muscle sympathetic nerve spectra. Coherence among signals varied as functions of both frequency and time. Partialization abolished the coherence among these signals at respiratory but not at low frequencies. The mode of breathing did not influence low-frequency oscillations, and they persisted during apnea. Our study documents the independence of low-frequency rhythms from respiratory activity and suggests that the close correlations that may exist among arterial pressures, R-R intervals, and muscle sympathetic nerve activity at respiratory frequencies result from the influence of respiration on these measures rather than from arterial baroreflex physiology. Most importantly, our results indicate that correlations among autonomic and hemodynamic rhythms vary over time and frequency, and, thus, are facultative rather than fixed.  相似文献   

11.
To assess the homogeneity of airway responses to inhaled histamine we examined regional alveolar pressure excursions (PA) arising from small-amplitude oscillations applied at the airway opening (Pao). In five anesthetized and vagotomized dogs the sternum was split and the anterior right lung field exposed. PA was sampled using four capsules affixed to the right apical and middle lobes while lung impedance (ZL) and airway impedances (Zaw) were measured during conventional tidal breathing and during forced oscillations (2-60 HZ at 10 cmH2O distending pressure). During tidal breathing after exposure to aerosol histamine regional PA's could be separated into three groups by plotting Lissajous figures of PA vs. Pao: PA in phase with Pao (no looping), PA lagging Pao (moderate looping), and PA decreasing while Pao was increasing and vice versa (paradoxical looping), suggesting unresponsive, responsive, and closed pathways, respectively, between the airway opening and specific alveolar zones. During high-frequency oscillation the corresponding PA spectra were markedly different from control spectra and revealed resonant amplification, overdamped resonance, and marked attenuation, respectively. With induced bronchospasm resonant amplification of PA was damped on average. However, the more obstructed and closed pathways were protected from resonant amplification, and the more open (nonlooping) pathways were subjected to resonant amplification greater than in the control state. In spite of this markedly nonhomogeneous behavior, frequency dependence of ZL was consistent with the model by Mead (J. Appl. Physiol. 26: 670-673, 1969), which ignores nonhomogeneity of peripheral compartments. These data demonstrate that the response of airways to inhaled histamine is nonhomogeneous but that frequency dependence of ZL above 2 Hz is not sufficient to characterize this nonhomogeneity.  相似文献   

12.
Relaxed expirations were obtained from five anesthetized dogs under control conditions and during various rates of intravenous infusion of histamine. All volume vs. time curves obtained from 20 ms to 2 s after the start of expiration were poorly described by a single exponential function but were fitted very well by a biexponential function. The resistance of the respiratory system as a function of frequency from 2 to 26 Hz was also determined by the forced oscillation method in the same dogs. Three two-compartment models of the respiratory system were identified from the exponentials fitted to the relaxed expiration data, and the one that had the most plausible parameter values under control conditions consisted of a homogeneous lung compartment connected to a viscoelastic compartment. Although a two-compartment model is arguably appropriate for describing relaxed expirations in normal dogs, physiological considerations suggest that there should be more than two interacting components with histamine infusion. We cannot identify all these components from our data, however. The equivalent complex impedance of the respiratory system was also calculated from the biexponential curves and showed significant variation in resistance over the frequency range from 0 to 2 Hz and negligible variation above 2 Hz. The calculated resistances at 2 Hz were consistently higher than those obtained by the forced oscillation method, which may be due to the nonlinear behavior of the respiratory system during relaxed expiration. We conclude that the single-breath and forced oscillation methods should be viewed as providing complimentary information about respiratory resistance.  相似文献   

13.
Many previous studies have fit lumped parameter models to respiratory input (Zin) and transfer (Ztr) impedance data. For frequency ranges higher than 4-32 Hz, a six-element model may be required in which an airway branch (with a resistance and inertance) is separated from a tissue branch (with a resistance, inertance, and compliance) by a shunt compliance. A sensitivity analysis is applied to predict the effects of frequency range on the accuracy of parameter estimates in this model obtained from Zin or Ztr data. Using a parameter set estimated from experimental data between 4 and 64 Hz in dogs, both Zin and Ztr were simulated from 4 to 200 Hz. Impedance sensitivity to each parameter was also calculated over this frequency range. The simulation predicted that for Zin a second resonance occurs near 80 Hz and that the impedance is considerably more sensitive to several of the parameters at frequencies surrounding this resonance than at any other frequencies. Also, unless data is obtained at very high frequencies (where the model is suspect), Zin data provides more accurate estimates than Ztr data. After adding random noise to the simulated Zin data, we attempted to extract the original parameters by using a nonlinear regression applied to three frequency ranges: 4-32, 4-64, and 4-110 Hz. Estimated parameters were substantially incorrect when using only 4- to 32-Hz or 4- to 64-Hz data, but nearly correct when fitting 4- to 110-Hz data. These results indicate that respiratory system parameters can be more accurately extracted from Zin than Ztr, and to make physiological inferences from parameter estimates based on Zin impedance data in dogs, the data must include frequencies surrounding the second resonance.  相似文献   

14.
The lumped six-element model of the respiratory system proposed by DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956) has often been used to analyze respiratory system impedance (Zrs) data. This model predicts a resonance (relative minimum in Zrs) at fr between 6 and 10 Hz and an antiresonance (relative maximum in Zrs) at far at higher frequencies (greater than 64 Hz). The far is due to the lumped tissue inertance (Iti) and the alveolar gas compression compliance (Cg). An fr and far have been recently reported in humans, but the far was shown to be not related to Iti and Cg, but instead it is the first acoustic antiresonance of the airways due to their axial dimensions). Zrs data to frequencies high enough to include the far have not been reported in dogs. In this study, we measured Zrs in dogs for frequencies between 5 and 320 Hz and found an fr at 7.5 +/- 1.6 Hz and two far at 97 +/- 13 and 231 +/- 27 Hz (far,1 and far,2, respectively). When breathing 80% He-20% O2, the fr shifted to 14 +/- 2 Hz, far,1 did not change (98 +/- 9 Hz), and far,2 increased to greater than 320 Hz. The behavior of fr and far,1 is consistent with the structure-function implied by the six-element model. However, the presence of an far,2 is not consistent with this model, because it is the airway acoustic antiresonance not represented in the model. These results indicate that, for frequencies that include the fr and far,1, the six-element model can be used to analyze Zrs data and reliable estimates of the model's parameters can be extracted by fitting the model to the data. However, more complex models must be used to analyze Zrs data that include far,2.  相似文献   

15.
beta 2-Adrenergic bronchodilator and muscarinic cholinergic bronchoconstrictor agonists both stimulate ciliary activity in vitro. To test the hypothesis that increases in autonomic activity would result in increases in ciliary beat frequency (CBF) in vivo, a correlation analysis heterodyne laser light-scattering system was developed and validated to measure the stimulating effects of sympathomimetic and parasympathomimetic agonists on tracheal CBF in intact, anesthetized beagles. The mean baseline CBF from 42 studies of 274 measurements in 9 (5 male and 4 female) adult beagles was 6.6 +/- 1.1 Hz. The stimulating effects of a beta 2-adrenergic agonist, fenoterol, and a muscarinic cholinergic agonist, methacholine, on CBF were studied on four and eight beagles, respectively. The studies were randomized and blinded. Aerosolized 10(-5) M fenoterol stimulated the CBF from the base line of 6.8 +/- 2.5 to 32.0 +/- 17.9 Hz in four dogs. Aerosolized methacholine stimulated the CBF from the base line of 5.8 +/- 0.7 to 9.4 +/- 3.0 Hz for 10(-8) M, and to 12.6 +/- 3.1 Hz for 10(-6) M in eight dogs. These are the first data obtained in intact animals that demonstrate CBF in the lower respiratory tract is regulated by autonomic agonists.  相似文献   

16.
The effect of deep breathing controlled in both rate and amplitude on the heart rate variability (HRV) and respiration-dependent blood flow oscillations was studied in the forearm and finger-pad skin of healthy 18- to 25-year-old volunteers. In order to reveal the effects of the divisions of the autonomic nervous system on the amplitudes of respiratory sinus arrhythmia (RSA) and skin blood flow oscillations, we studied the indices of the cardiovascular system in two groups of subjects with respectively lower and higher values of the sympatho-vagal balance. This index was calculated as a ratio of low frequency and high frequency HRV spectral power (LF/HF) under the conditions of spontaneous breathing. It was found that, in subjects with a predominant parasympathetic tone, the amplitudes of RSA and the rate of blood flow in the finger-pad skin were higher compared to subjects with a predominant sympathetic tone during respiration with the frequency lower than 4 cycle/min. In the forearm skin, where sympathetic innervation is weaker compared to the finger-pad skin, there were no significant differences in respiration-dependent oscillations of the rate of blood flow in two groups of subjects.  相似文献   

17.
Respiratory muscle blood flow and organ blood flow during endotoxic shock were studied in spontaneously breathing dogs (SB, n = 6) and mechanically ventilated dogs (MV, n = 5) with radiolabeled microspheres. Shock was produced by a 5-min intravenous injection of Escherichia coli endotoxin (0.55:B5, Difco, 10 mg/kg) suspended in saline. Mean arterial blood pressure and cardiac output in the SB group dropped to 59 and 45% of control values, respectively. There was a similar reduction in arterial blood pressure and cardiac output in the MV group. Total respiratory muscle blood flow in the SB group increased significantly from the control value of 51 +/- 4 ml/min (mean +/- SE) to 101 +/- 22 ml/min at 60 min of shock. In the MV group, respiratory muscle perfusion fell from control values of 43 +/- 12 ml/min to 25 +/- 3 ml/min at 60 min of shock. In the SB group, 8.8% of the cardiac output was received by the respiratory muscle during shock in comparison with 1.9% in the MV group. In both groups of dogs, blood flow to most organs was compromised during shock; however, blood flow to the brain, gut, and skeletal muscles was higher in the MV group than in the SB group. Thus by mechanical ventilation a fraction of the cardiac output used by the working respiratory muscles can be made available for perfusion of other organs during endotoxic shock.  相似文献   

18.
We report that nicotine is responsible for both a blood-borne stimulation of the respiratory center and a direct effect on intrathoracic airway tone in dogs. We introduced cigarette smoke into the lungs of donor dogs and injected arterial blood obtained from them into the circulation of recipient dogs to show that a blood-borne material increased breathing and airway smooth muscle tone. Smoke from cigarettes containing 2.64 mg of nicotine was effective; that from cigarettes containing 0.42 mg of nicotine was not. Nicotine, in doses comparable to the amounts absorbed from smoke, also increased breathing and tracheal smooth muscle tension when injected into the vertebral circulation of recipient dogs. Finally, blockade of nicotine receptors in the central nervous system and in the airway parasympathetic ganglia inhibited the effects of inhaled cigarette smoke and intravenous nicotine on the respiratory center and on bronchomotor tone. We conclude that nicotine absorbed from cigarette smoke is the main cause of cigarette smoke-induced bronchoconstriction. It caused central respiratory stimulation, resulting in increased breathing and airway smooth muscle tension, and had a direct effect on airway parasympathetic ganglia as well.  相似文献   

19.
The dynamics of forced inhale (I series) and exhale (II series) parameters with additional external artificial resistive load was studied under normobaric conditions. The artificial resistance to breathing increased stepwise using removable diaphragms with sequential decrease of hole diameter from 25, 17, 13, 9, 7.5, 4.5 to 3 mm. While studying forced inhale the diaphragms were set up at Fleish pipe airflow input. In the case of forced inhale the diaphragms were set up at the pipe output. A phenomenon is revealed which consists in appearance of respiratory flow oscillations on the "flow-volume" curves during forced breathing with an increase of resistive load. Frequency maxima of the oscillations were located within the range of 6-15 Hz. The possible mechanisms for appearance of respiratory muscle tremor and respiratory flow oscillations are under discussion.  相似文献   

20.
The low-frequency resistances of the respiratory system, lung, and chest wall were investigated in four anesthetized paralyzed dogs mechanically ventilated at various frequencies between 0.08 and 0.83 Hz. The resistances were calculated by three different methods: 1) as the real part of the complex impedance obtained from regular ventilation data, 2) as the effective resistance of a two-compartment model fitted to the same data, and 3) as the resistance of a single-compartment model fitted to data obtained during sinusoidal ventilation at various frequencies. Alveolar pressures were measured by a closed-chest alveolar capsule technique and afforded a direct measure of airways resistance. All three resistance estimates were very similar and decreased markedly with frequency between 0 and 1 Hz. The real part of lung impedance at the higher frequencies investigated (around 5 Hz) closely approximated airways resistance, as predicted by the eight-parameter viscoelastic model of respiratory mechanics proposed by Bates et al. (J. Appl. Physiol. 67:2276-2285, 1989).  相似文献   