首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Maximum oxygen uptake (VO2max) was measured directly and predicted from cardiac frequency measurements in 54 healthy Chilean industrial workers aged 20 to 55 years, together with assessment of their dietary intake, body composition and blood chemistry. Measurement of VO2 was performed on a motor-driven treadmill. The predicted VO2max was obtained using a cycle ergometer by two methods: 1) the Astrand-Ryhming nomogram and 2) the linear relationship between "steady state" heart rate (HR) and submaximum work, with subsequent extrapolation to "maximum" heart rate. Extrapolation of the HR/load regression line to 170 bpm permitted determination of the physical working capacity at 170 bpm (W170). VO2max for the 20-29 year group (Group I) averaged 3624 ml.min-1 and decreased to 3066 ml.min-1 in the 50-55 year group (Group IV). Lower values were obtained using the Astrand-Ryhming nomogram and HR/load regression (-15% and -9% respectively). W170 was also affected by age (Group I: 190.6 W and Group IV: 158.5 W). No significant correlation were found between VO2max and plasma variables, with the exception of cholesterol (r = 0.59). On the contrary, anthropometric variables showed significant correlations with VO2max, which permitted the prediction of VO2max using multiple regression equations. The two best correlations were: 1. VO2max = 0.800 - 0.0225.(A) +0.0189.(W)+1.26.(H) (r = 0.87; p less than 0.001) 2. VO2max = 0.996 - 0.0176.(A) + 0.025.(W) + 0.838.(H) + 0.0255.(LBM) (r = 0.88; p less than 0.001) where A = years of age; W = body weight in kg; H = height in m and LBM = lean body mass in kg.  相似文献   

2.
The relationship between fat-free mass (FFM) and excess post-exercise oxygen consumption (EPOC) has not been well researched because of the relatively small number of subjects studied. This study investigated the effects of FFM on EPOC and EPOC/maximum oxygen consumption. 250 Japanese male athletes between 16 and 21 years old from Nagasaki prefecture had their EPOC measured up to 40 minutes after short-duration exhaustive exercise. The value was named as EPOC40 min. The proportions of EPOC up to 1, 3, 6, 10, and 25 minutes to EPOC40 min were calculated and named as P1, P3, P6, P10, and P25, respectively. Body size and composition, VO2max and resting metabolic rate (RMR) were also measured. Mean EPOC40 min was 9.04 L or 158 ml/kg FFM. EPOC40 min was related to FFM (r=0.55, p<0.001) and VO2max (r=0.37, p<0.001). The ratio of EPOC40 min to VO2max was related to FFM (r=0.28, p<0.001). P1, P3, P6, P10, and P25 were negatively related to EPOC40 min/FFM, EPOC40 min/VO2max, and FFM. Athletes who had larger FFM had larger EPOC40 40 min and EPOC40 40 min/VO2max, and smaller P1, P3, P10, and P25.  相似文献   

3.
A multi-stage, repetitive lifting maximal oxygen uptake (VO2max) test was developed to be used as an occupational research tool which would parallel standard ergometric VO2max testing procedures. The repetitive lifting VO2max test was administered to 18 men using an automatic repetitive lifting device. An intraclass reliability coefficient of 0.91 was obtained with data from repeated tests on seven subjects. Repetitive lifting VO2max test responses were compared to those for treadmill, cycle ergometer and arm crank ergometer. The mean +/- SD repetitive lifting VO2max of 3.20 +/- 0.42 l.min-1 was significantly (p less than 0.01) less than treadmill VO2max (delta = 0.92 l.min-1) and cycle ergometer VO2max (delta = 0.43 l.min-1) and significantly greater than arm crank ergometer VO2max (delta = 0.63 l.min-1). The correlation between repetitive lifting oxygen uptake and power output was r = 0.65. VO2max correlated highly among exercise modes, but maximum power output did not. The efficiency of repetitive lifting exercise was significantly greater than that for arm cranking and less than that for leg cycling. The repetitive lifting VO2max test has an important advantage over treadmill or cycle ergometer tests in the determination of relative repetitive lifting intensities. The individual curves of VO2 vs. power output established during the multi-stage lifting VO2max test can be used to accurately select work loads required to elicit given percentages of maximal oxygen uptake.  相似文献   

4.
Maximal oxygen uptake (VO2max.), glucose tolerance (K-value), and insulin response (IRI-area) were studied in seventeen young, non-obese, non-diabetic males. The ratio between K-value and IRI-area correlated significantly with VO2 max. (r = 0.70, p less than 0.01) also when differences in body fat mass were eliminated by partial correlation analysis (r = 0.56, p less than 0.05). Subjects with a high VO2 max. thus maintained a given glucose tolerance with a lower insulin response than did subjects in whom VO2 max. was low.  相似文献   

5.
Sixteen men were tested to determine VO2max (ml X kg-1 X min-1), anaerobic threshold VO2 (ATVO2) and oxygen kinetics (time constant, T.C.) during running on a treadmill. For measuring maximal calf blood flow (maxBF, ml X 100 ml-1 X min-1), venous occlusion plethysmography was employed immediately following a combination of arterial occlusion and toe raising exercise to exhaustion. In addition, supramaximal electrical stimulations were given to determine maximal calf twitch force (Fmax, N), maximal rate of twitch force development (dF/dt) and relaxation (R X dF/dt, N X ms-1) and electro-mechanical delay time (EMD, ms). Results demonstrated that VO2max, ATVO2 and maxBF were all inversely related to T.C. (p less than 0.05). MaxBF and ATVO2 showed the highest correlation (r = 0.89, p less than 0.01). Stepwise multiple linear regression analyses revealed that variance in VO2max (60%) and ATVO2 (84%) could be accounted for by the combined effects of the following peripheral factors: VO2max = 51,25-3.24(dF/dt) + 0.14(maxBF), and ATVO2 = 11.68 + 0.42(maxBF) - 0.2(Fmax). These findings, together with the results of cluster analysis, suggest a tight link between ATVO2 and peripheral blood flow capacity. On the other hand, a moderate correlation (r = 0.64, p less than 0.01) between VO2max and maxBF might be due in part to individual differences in oxygen extraction-utilization capacity during heavy exercise above anaerobic threshold.  相似文献   

6.
Ten men and 11 women were studied to determine the effect of experimentally equating haemoglobin concentration ([Hb]) on the sex difference in maximal oxygen uptake (VO2max). VO2max was measured on a cycle ergometer using a continuous, load-incremented protocol. The men were studied under two conditions: 1) with normal [Hb] (153 g X L-1) and 2) two days following withdrawal of blood, which reduced their mean [Hb] to exactly equal the mean of the women (134 g X L-1). Prior to blood withdrawal, VO2max expressed in L X min-1 and relative to body weight and ride time on the cycle ergometer test were greater (p less than .01) in men by 1.11 L X min-1 (47%), 4.8 ml X kg-1 min-1 (11.5%) and 5.9 min (67%), respectively, whereas VO2max expressed relative to fat-free weight (FFW) was not significantly different. Equalizing [Hb] reduced (p less than .01) the mean VO2max of the men by 0.26 L X min-1 (7.5%), 3.2 ml X kg-1 min-1 (6.9%) or 4.1 ml X kg FFW-1 min-1 (7.7%), and ride time by 0.7 min (4.8%). Equalizing [Hb] reduced the sex difference for VO2max less than predicted from proportional changes in the oxygen content of the arterial blood and arteriovenous oxygen content difference during maximal exercise. It was concluded that the sex difference in [Hb] accounts for a significant, but relatively small portion of the sex difference in VO2max (L X min-1). Other factors such as the dimensions of the oxygen transport system and musculature are of greater importance.  相似文献   

7.
Fifty-five male runners aged between 30 to 80 years were examined to determine the relative roles of various cardiovascular parameters which may account for the decrease in maximal oxygen uptake (VO2max) with aging. All subjects had similar body fat composition and trained for a similar mileage each week. The parameters tested were VO2max, maximal heart rate (HRmax), cardiac output (Q), and arteriovenous difference in oxygen concentration (Ca-Cv)O2 during graded, maximal treadmill running. Average body fat and training mileage were roughly 12% and 50 km.week-1, respectively. The average 10-km run-time slowed significantly by 6.0%.decade-1 [( 10-km run-time (min) = 0.323 x age (years) + 24.4] (n = 49, r = 0.692, p less than 0.001]. A strong correlation was found between age and VO2max [( VO2max (ml.kg-1.min-1) = -0.439 x age + 76.5] (n = 55, r = -0.768, p less than 0.001]. Thus, VO2max decreased by 6.9%.decade-1 along with reductions of HRmax (3.2%.decade-1, p less than 0.001) and Q (5.8%.decade-1, p less than 0.001), while no significant change with age was observed in estimated (Ca-Cv)O2. It was concluded that the decline of VO2max with aging in runners was mainly explained by the central factors (represented by the decline of HR and Q in this study), rather than by the peripheral factor (represented by (Ca-Cv)O2).  相似文献   

8.
Nineteen healthy male subjects, differing in training status and Vo2max (52 +/- 1 ml.min-1.kg-1, mean +/- SEM; 43-64 ml.min-1.kg-1, range), exercised for 1 h at an absolute workload of 192 +/- 8 W (140-265 W); this was equivalent to 70 +/- 1% Vo2max (66-74%). Each exercise test was performed on an electrically braked cycle ergometer at a constant ambient temperature (22.5 +/- 0.0 degrees C) and relative humidity (85 +/- 0%). Nude body weight was recorded prior to and after each exercise test. Absolute sweat loss (body weight loss corrected for respiratory weight loss) during each test was 910 +/- 82 g (426-1665 g); this was equivalent to 1.3 +/- 0.1% (0.7-2.2%) of pre-exercise body weight (relative sweat loss). Weighted mean skin temperature and rectal temperature increased after 5 min of exercise from 30.5 +/- 0.3 degrees C and 37.2 +/- 0.1 degrees C respectively to 32.5 +/- 0.2 degrees C and 38.8 +/- 0.1 degrees C respectively, recorded immediately prior to the end of exercise. Bivariate linear regression and Pearson's correlation demonstrated absolute sweat loss was related to Vo2max (r = 0.72, p less than 0.001), absolute exercise workload (r = 0.66, p less than 0.01), body surface area (r = 0.62, p less than 0.01), weight (r = 0.60, p less than 0.01) and height (r = 0.53, p less than 0.05). Relative sweat loss was related to VO2max (r = 0.77, P less than 0.001) and absolute exercise workload (R = 0.59, P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
The purpose of this investigation was to determine whether sweat lactate secretion during exercise [approximately 70% maximum O2 consumption (VO2max), 60 min] differed in active vs. sedentary female subjects. Sweat rate, total sweat lactate secretion, and sweat lactate concentration were monitored in a group of sedentary (VO2max = 41.0 +/- 1.62 ml X kg-1 X min-1) and active (VO2max = 51.2 +/- 3.20 ml X kg-1 X min-1) women. Sweat rate was significantly (P less than 0.05) greater in the active subjects. There was a significant difference between groups in total amount of sweat lactate secreted (P less than 0.05), with the active group secreting less lactate (29.8 +/- 5.03 mmol, mean +/- SE) than the sedentary group (50.2 +/- 6.61 mmol). Concomitant with the lower total sweat lactate secretion in the active subjects was a significantly (P less than 0.05) more dilute sweat lactate concentration (42.6 +/- 14.08 vs. 100.4 +/- 32.37 mM). In these female subjects, sweat lactate concentration was inversely correlated (r = -0.79, P less than 0.01, n = 10) to sweat rate. It is concluded that total sweat lactate loss is significantly less in active than in sedentary women and that the active subjects secrete a greater quantity of lactate dilute sweat.  相似文献   

10.
Maximal and submaximal metabolic and cardiovascular measures and work capacity were studied in control (n = 7) and experimental (n = 9) subjects (S's) during arm work prior to and following 10 wk of interval arm training. These measures were oxygen uptake (VO2), minute ventilation (VE), heart rate (HR), respiratory exchange ratio (R), cardiac output (Q), stroke volume (SV), and arteriovenous oxygen difference ((a--v)O2 diff). In addition, maximal oxygen uptake (VO2max) was measured in both groups during treadmill running. Experimental S's showed significant increases (P less than 0.01) in peak VO2 (438 ml.min-1), max VE (17.7 l.min-1), max (a--v)O2 diff (20.8 ml.l-1), and work time (9.2 min) during arm ergometry, while maximum values of Q, SV, HR, and R remained unchanged. In addition, submaximal heart rates were significantly lower during arm ergometry after training. VO2max during treadmill running remained essentially unchanged. No changes in metabolic and physiological measures were noted for the controls after the 10-wk training period. The results support the concept of training specificity for VO2max, and indicate that the improvement in peak VO2 in arm ergometry reflects enhanced oxygen utilization due to an expanded (a--v)O2 diff.  相似文献   

11.
Familial resemblance in maximal heart rate, blood lactate and aerobic power   总被引:1,自引:0,他引:1  
There are considerable interindividual differences in maximal oxygen uptake per kilogram of body weight (VO2 max/kg), maximal heart rate (max HR) and maximal blood lactate (max blood La) measured during a progressive exercise test. The aim of the study was to quantify the familial relationships for these variables. Parents and children of 38 families of French-Canadian descent were submitted to a modified Balke treadmill test. VO2 max/kg and max HR were the highest values reached during the test for 1 min. Max blood La was obtained from a blood sample taken 2 min after the test. The effects of age and sex were significant for max blood La and VO2 max/kg in each generation. Scores were thus adjusted through multiple regression procedures (age + sex + age X sex + age2), yielding residuals which were submitted to further analysis. Intraclass correlations (ri) were significant in pairs of sibs for max blood La and max HR, i.e. 0.28 (p less than 0.01) and 0.43 (p less than 0.05), respectively. For VO2 max/kg, pairs of spouses and sibs were about similarly correlated (ri = 0.20 and 0.15; p less than 0.05). Data suggested that children were more related to their mother than to their father for VO2 max/kg, VO2 max/kg of fat-free weight, and particularly for max HR. It was concluded that familial resemblance and heritability estimates for maximal aerobic power, max HR and max blood La were quite low and generally nonsignificant. Correlations between biological sibs were, however, consistently significant for max HR and max blood La. The suggestion of a maternal effect in maximal aerobic power should be further investigated.  相似文献   

12.
Recent evidence suggests that heavy exercise may lower the percentage of O2 bound to hemoglobin (%SaO2) by greater than or equal to 5% below resting values in some highly trained endurance athletes. We tested the hypothesis that pulmonary gas exchange limitations may restrict VO2max in highly trained athletes who exhibit exercise-induced hypoxemia. Twenty healthy male volunteers were divided into two groups according to their physical fitness status and the demonstration of exercise-induced reductions in %SaO2 less than or equal to 92%: 1) trained (T), mean VO2max = 56.5 ml.kg-1.min-1 (n = 13) and 2) highly trained (HT) with maximal exercise %SaO2 less than or equal to 92%, mean VO2max = 70.1 ml.kg-1.min-1 (n = 7). Subjects performed two incremental cycle ergometer exercise tests to determine VO2max at sea level under normoxic (21% O2) and mild hyperoxic conditions (26% O2). Mean %SaO2 during maximal exercise was significantly higher (P less than 0.05) during hyperoxia compared with normoxia in both the T group (94.1 vs. 96.1%) and the HT group (90.6 vs. 95.9%). Mean VO2max was significantly elevated (P less than 0.05) during hyperoxia compared with normoxia in the HT group (74.7 vs. 70.1 ml.kg-1.min-1). In contrast, in the T group, no mean difference (P less than 0.05) existed between treatments in VO2max (56.5 vs. 57.1 ml.kg-1.min-1). These data suggest that pulmonary gas exchange may contribute significantly to the limitation of VO2max in highly trained athletes who exhibit exercise-induced reductions in %SaO2 at sea level.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
There are conflicting reports in the literature which imply that the decrement in maximal aerobic power experienced by a sea-level (SL) resident sojourning at high altitude (HA) is either smaller or larger for the more aerobically "fit" person. In the present study, data collected during several investigations conducted at an altitude of 4300 m were analyzed to determine if the level of aerobic fitness influenced the decrement in maximal oxygen uptake (VO2max) at HA. The VO2max of 51 male SL residents was measured at an altitude of 50 m and again at 4300 m. The subjects' ages, heights, and weights (mean +/- SE) were 22 +/- 1 yr, 177 +/- 7 cm and 78 +/- 2 kg, respectively. The subjects' VO2max ranged from 36 to 60 ml X kg -1 X min -1 (mean +/- SE = 48 +/- 1) and the individual values were normally distributed within this range. Likewise, the decrement in VO2max at HA was normally distributed from 3 ml X kg-1 X min-1 (9% VO2max at SL) to 29 ml X kg-1 X min-1 (54% VO2max at SL), and averaged 13 +/- 1 ml X kg-1 X min-1 (27 +/- 1% VO2max at SL). The linear correlation coefficient between aerobic fitness and the magnitude of the decrement in VO2max at HA expressed in absolute terms was r = 0.56, or expressed as % VO2max at SL was r = 0.30; both were statistically significant (p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
To test the hypothesis that maximal O2 uptake (VO2max) can be limited by O2 diffusion in the peripheral tissue, we kept O2 delivery [blood flow X arterial O2 content (CaO2)] to maximally contracting muscle equal between 1) low flow-high CaO2 and 2) high flow-low CaO2 conditions. The hypothesis predicts, because of differences in the capillary PO2 profile, that the former condition will result in both a higher VO2max and muscle effluent venous PO2 (PVO2). We studied the relations among VO2max, PVO2, and O2 delivery during maximal isometric contractions in isolated, in situ dog gastrocnemius muscle (n = 6) during these two conditions. O2 delivery was matched by varying arterial O2 partial pressure and adjusting flow to the muscle accordingly. A total of 18 matched O2 delivery pairs were obtained. As planned, O2 delivery was not significantly different between the two treatments. In contrast, VO2max was significantly higher [10.4 +/- 0.5 (SE) ml.100 g-1.min-1; P = 0.01], as was PVO2 (25 +/- 1 Torr; P less than 0.01) in the low flow-high CaO2 treatment compared with the high flow-low CaO2 treatment (9.1 +/- 0.4 ml.100 g-1.min-1 and 20 +/- 1 Torr, respectively). The rate of fatigue was greater in the high flow-low CaO2 condition, as was lactate output from the muscle and muscle lactate concentration. The results of this study show that VO2max is not uniquely dependent on O2 delivery and support the hypothesis that VO2max can be limited by peripheral tissue O2 diffusion.  相似文献   

15.
Maximal exercise responses were measured before and after 10 weeks of training in two groups of men, one trained on a treadmill (n = 12) and the other on a step ergometer (n = 9); the groups were pre- and post-tested on both machines to examine the specificity of the training modes. Training for both groups consisted of 3 days week-1, 30 min day-1, progressing to 50 min day-1, at an intensity of 75%-80% heart rate maximum reserve. Pre-training maximal oxygen uptake (VO2max) was significantly higher on the treadmill for both groups (X = 8.5%). VO2max increased 6.9% on the treadmill (P less than 0.05) and 6.9% (P greater than 0.05) on the step ergometer after treadmill training. The small increases may be attributed to the specificity of the testing protocols used to elicit VO2max. Significant (P less than 0.01) increases in VO2max were found for both modalities after step-ergometry training (treadmill = 11.8%; step ergometer = 23.2%). These increases resulted in equal post-test VO2max values (4.05 l min-1; 51 ml kg-1 min-1) on the step ergometer and treadmill. The significant increases in VO2max found for both modalities after step-ergometry training shows that (1) step ergometry is an effective training modality, and (2) its effects can be measured on the treadmill and therefore it is not task-specific training.  相似文献   

16.
The main purpose of this study was to assess the validity of the Cosmed Fitmate (FM) for the prediction of maximal oxygen consumption (VO(2)max). In addition, this study examined whether measuring submaximal VO(2), rather than predicting it, can improve upon the prediction of VO(2)max. Participants for the study were 48 young to middle-age adults (32 men, 16 women), with a mean age of 31 yr. Each participant completed a submaximal and maximal treadmill test on 2 separate occasions. During the submaximal test, VO(2)max was predicted using the FM. This device extrapolates the linear regression relating heart rate (HR) and measured VO(2) at submaximal work rates to age-predicted maximum HR (HR = 220 - age). The criterion measure was obtained using a graded, maximal treadmill test, with VO(2) measured by the Douglas bag (DB) method. There was no significant difference between VO(2)max predicted by the FM and VO(2)max measured by the DB method. The results of this study showed that a strong positive correlation (r = 0.897) existed between VO(2)max predicted by the FM and VO(2)max measured by the DB method, with a standard error of the estimate (SEE) = 3.97 ml·kg(-1)·min(-1). There was a significant difference in VO(2)max predicted by the American College of Sports Medicine (ACSM) metabolic equations and VO(2)max measured by the DB method (p = 0.01). The correlation between these variables was r = 0.758 (SEE = 5.26 ml·kg(-1)·min(-1)). These findings indicate that a small, portable, and easy-to-use metabolic system provides valid estimates of VO(2)max, and improves upon predictive accuracy, compared to using generalized ACSM metabolic equations.  相似文献   

17.
Size at birth, fat-free mass and resting metabolic rate in adult life.   总被引:5,自引:0,他引:5  
Resting metabolic rate is an important predictor of obesity and is closely related to fat-free mass. There is evidence that fat-free mass may be partly determined during critical periods of growth before and after birth. The objective of this study was to examine the relationship between size at birth, childhood growth and fat-free mass and resting metabolic rate in adult life. 318 men and women with detailed records of body size at birth and growth during school years participated in the study. Fat-free mass correlated positively with birth weight among both sexes (r = 0.264, p < 0.001). Those having a higher birth weight had a higher fat-free mass at any adult BMI. Fat-free mass among men increased by 2.2 kg (95 % Cl 0.5 to 3.9; p = 0.01) for every kg increase in birth weight and by 1.5 kg (95 % Cl 1.3 to 1.7, p < 0.0001) for every kg/m(2) BMI in adult life. In women, fat-free mass increased by 2.7 kg (95 % Cl 1.6 - 3.9; p < 0.001) for every kg increase in birth weight and by 0.8 kg (95 % CI 0.7 to 1.0, p < 0.001) for every kg/m(2) of BMI in adult life. Height, weight and body mass index at each age from 7 to 15 years were also strongly, positively associated with fat-free mass. A negative correlation between birth weight and resting metabolic rate expressed per unit of fat-free mass (r = - 0.158; p < 0.001) was found. Fat-free mass may be determined during critical periods of muscle growth in utero and during childhood. The muscle tissue of people who had a lower birth weight is more metabolically active than those with a higher birth weight. This may protect them from the increased risk of obesity associated with low fat-free mass.  相似文献   

18.
The thermogenic response to an insulin and glucose infusion was determined in 10 healthy lean volunteers using a euglycemic clamp technique in conjunction with respiratory exchange measurements. The progressive rise in resting metabolic rate (RMR) from 4.295 ± 0.360 kJ/min during the baseline to 4.771 ± 0.410 kJ/min during the 90–120 min period of the euglycemic clamp (p < 0.01) correlated with the progressive increase in the glucose infusion rate (r = 0.836, p < 0.01), with the glucose storage rate (r = 0.812, p < 0.01), but not with the significant rise in insulin or norepinephrine concentrations. Storage of nutrients, as well as increased sympathetic nervous system (SNS) activity are known to increase RMR. Two thirds to three quarters of the observed increment in RMR following the insulin and glucose infusion in this study can be accounted for by the metabolic processing of the infused glucose for storage purposes. The rest of the thermogenic response (24–35%) must be explained by other mechanisms such as increased SNS activity.  相似文献   

19.
Twenty-eight subjects (6 normal men, 14 distance runners, and 8 rowers) were tested for maximal oxygen uptake (VO2max) and associated physiological measures during bicycle ergometer exercise with toe stirrups while standing (BEts) and during treadmill exercise (TM). Correlation between BEts VO2max and TM VO2max was high (r = 0.901, p less than 0.05). No significant difference existed between the two VO2max values (60.3 +/- 8.9 vs. 60.5 +/- 9.7 ml.kg-1.min-1; n = 28). No differences were found even when three different subgroups were separately compared. It is concluded that the higher VO2max elicited during BEts as compared with normal sitting cycling may be attributed to the increased muscle blood flow and/or involvement of a larger muscle mass, the latter being partly evidenced by the observation of greater electromyographic activity during BEts.  相似文献   

20.
The purpose of this study was to determine whether a test developed to predict maximal oxygen consumption (VO2max) during over-ground walking, was similarly valid as a predictor of peak oxygen consumption (VO2) when administered during a 1-mile (1.61 km) treadmill walk. Treadmill walk time, mean heart rate over the last 2 full min of the walk test, age, and body mass were entered into both generalized (GEN Eq.) and gender-specific (GSP Eq.) prediction equations. Overall results indicated a highly significant linear relationship between observed peak VO2 and GEN Eq. predicted values (r = 0.91), a total error (TE) of 5.26 ml.kg-1.min-1 and no significant difference between observed and predicted peak VO2 mean values. The peak VO2 for women (n = 75) was predicted accurately by GSP Eq. (r = 0.85; TE = 4.5 ml.kg-1.min-1), but was slightly overpredicted by GEN Eq. (overall mean difference = 1.4 ml.kg-1.min-1; r = 0.86; TE = 4.56 ml.kg-1.min-1). No significant differences between observed peak VO2 and either GEN Eq. (r = 0.85; TE = 4.3 ml.kg-1.min-1) or GSP Eq. (r = 0.85; TE = 4.8 ml.kg-1.min-1) predicted values were noted for men (n = 48) with peak VO2 values less than or equal to 55 ml.kg-1.min-1. However, both equations significantly underpredicted peak VO2 for the remaining high peak VO2 men (n = 22). In conclusion, the over-ground walking test, when administered on a treadmill, is a valid method of predicting peak VO2 but underpredicts peak VO2 of subjects with observed high peak VO2 values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号