首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

2.
Alzheimer disease (AD) is characterized by a complex heterogeneity of pathological changes, and any therapeutic approach categorically requires a multi‐targeted way. It has been demonstrated that together with the hallmarks of the disease such as neurofibrillary tangles and senile plaques, oxidative and inflammatory stress covered an important role. Dimethyl fumarate (DMF) is an orally bioavailable methyl ester of fumaric acid and activator of Nrf2 with potential neuroprotective and immunomodulating activities. Therefore, the aim of the present work was to evaluate the potential beneficial effects of DMF, compared with its active metabolite monomethyl fumarate (MMF) (both at 30 μM) in an in vitro Alzheimer's model using SH‐SY5Y human neuroblastoma cell lines stimulated with amyloid‐beta (Aβ). Moreover, the effect of DMF, compared with MMF, was evaluate by an ex vivo model using organotypic hippocampal slice cultures stimulated with Aβ1‐42 (1 μg/ml), to better understand its action in a pathological setting. In both models, DMF pre‐treatment (30 μM) preserved cellular viability from Aβ stimulation, reducing tau hyper‐phosphorylation, much more efficiently then MMF (30 μM). Moreover, DMF was able to induce an activation of manganese superoxide dismutase (MnSOD) and heme‐oxygenase‐1 (HO‐1), decreasing the severity of oxidative stress. Our results showed important multi‐protective effects of DMF pre‐treatment from Aβ stimulation both in in vitro and ex vivo models, highlighting an Nrf2/NF‐κB‐dependent mechanism, which could provide a valuable support to the therapies for neurodegenerative diseases today.  相似文献   

3.
A method is reported for determination of allantoin in urine and plasma based on high-performance liquid chromatography (HPLC) and pre-column derivatization. In the derivatization procedure, allantoin is converted to glyoxylic acid which forms a hydrazone with 2,4-dinitrophenylhydrazine. The hydrazone appears as syn and anti isomers at a constant ratio. These derivatives are separated by HPLC using a reversed-phase C18 column from hydrazones of other keto acids possibly present in urine and plasma and then monitored at 360 nm. All components were completely resolved in 15 min. Both the reagents and derivatization products are stable. Recovery of allantoin added to urine and plasma was 95 ± 3.7% (n = 45) and 100 ± 7.5% (n = 64), respectively. The lowest allantoin concentration that gave a reproducible integration was 5 μmol/l. The between-assay and within-day coefficients of variation were 2.8 and 0.6%, respectively.  相似文献   

4.
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(−)-α-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C18 silica column and detected using fluorescence (excitation λ: 215 nm, emission λ: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r2≥0.998 over the concentration range 8–100 ng ml−1 for plasma and 0.1–2.5 μg ml−1 for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently <10%. Assay parameters are similar to those of previously published assays for pindolol enantiomers, however this assay is significantly easier and cheaper to run. Clinically relevant concentrations of each pindolol enantiomer can readily be measured.  相似文献   

5.
PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart® (125 mm×4 mm I.D.) Nucleosil 100-5 μm C18 AB cartridge column, using a gradient elution of MeOH–buffer pH 3.9 1:99→15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate–citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2±2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (ClS) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73±0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87±0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.  相似文献   

6.
A simple, specific, and sensitive high-performance liquid chromatographic (HPLC) method for the determination of riboflavin directly in urine samples using a fixed-wave-length spectrofluorometer is described. Centrifuged raw urine samples (50 μl) are injected onto a reversed-phase microparticulate C18 column. The eluent is 0.01 M KH2PO4 (pH 5.0)—methanol (65:35). This method is capable of differentiating riboflavin from riboflavin-5-phosphate, non-riboflavin fluorescing components in urine, and photo-degraded riboflavin. The method shows good reproducibility and is linear to at least 12 μg/ml. The sensitivity of this procedure, at the 95% confidence limit, determined by linear regression analysis, is estimated to be 0.05 μg/ml using peak height and 0.07 μg/ml using peak area. This HPLC method is compared to an automated fluorometric method for riboflavin. The coefficient of linear regression of this comparison is Y = 0.858 + 0.893X, where X is the HPLC method and Y is the fluorometric method.  相似文献   

7.
Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C30 column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H2O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R2) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3 pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine.  相似文献   

8.
Determination of four toxic Aconitum alkaloids, aconitine, mesaconitine, hypaconitine and jesaconitine, in blood and urine samples has been established using high-performance liquid chromatography (HPLC) combined with ultraviolet absorbance detection, solid-phase extraction and mass spectrometry (MS). These alkaloids were hydrolyzed rapidly in alkaline solution (half lives (t1/2)<one day), were stable in solutions of acetonitrile, tetrahydrofuran and diluted hydrochloric acid (t1/2>five months) and were unstable in solutions of methanol and ethanol (t1/2<one month). These alkaloids were separated on an octadecylsilica column with isocratic elution using a solvent mixture of tetrahydrofuran and 0.2% trifluoroacetic acid (14:86, v/v), which was found to be the optimal solvent of the elution systems examined. Calibration curves with UV detection were linear on injection of amounts ranging from 2.5 to 500 ng, and the limit of detection was 1 ng (S/N = 3). These four alkaloids in aqueous solution were recovered almost totally by solid-phase extraction using the styrene polymer resin, Sep-Pak Plus PS-1, and were eluted using a mixture of acetonitrile and hydrochloric acid. These Aconitum alkaloids were confirmed by HPLC coupled with fast atom bombardment MS, giving their protonated molecular ions as base peaks. These alkaloids were detected by HPLC with UV detection from blood samples spiked with more than 50 ng ml−1 of alkaloids, but were not detectable from urine samples spiked with 5 μg ml−1 of alkaloids because of severe sample interference.  相似文献   

9.
A method based on reversed-phase HPLC is reported for the separation and quantification of various urinary aromatic metabolites: hippuric, phenylaceturic, salicyluric, benzoic, phenylacetic, salicylic. 3-phenylpropionic and cinnamic acids and several phenols in ruminant urine. In this method, a Nova-Pak C18 (4 μm) 150×3.9 mm I.D. column, two solvents [A: 15°b methanol in 20 mM acetic acid (pH 3.3); B: methanol] in a gradient mode at a flow-rate of 0.8 ml/min, and UV detection at 210 nm were used. Quantification of the total (free and conjugated) benzoic, phenylacetic and salicylic acids present in urine was achieved by hydrolysis of the samples in 3 M HCl at 100°C for 24 h prior to HPLC analysis. The lowest detection concentration was 50 μmol/I. This method is useful for scanning the profile of aromatic metabolites in urine of ruminants, which provides information on the diets the animals receive.  相似文献   

10.
A systematic optimization of the HPLC separation of a complex mixture containing 19 diuretics by micellar liquid chromatography using sodium dodecyl sulphate (SDS), a Hypersil (150 mm×3.0 mm I.D., 5 μm) C18 column, a flow-rate of 0.5 ml min−1 and UV absorbance detection has been carried out. Several mobile phases consisting of SDS and organic modifiers such as acetonitrile, tetrahydrofuran, propanol, butanol or pentanol, and the pH adjusted to 3.2, were tested. The effect of the organic modifier and SDS concentration on the retention behavior and separation of the diuretics was investigated. A mobile phase containing 40 mM SDS and 4% tetrahydrofuran was finally selected. Under these conditions, 14 out of 19 diuretics were separated in about 31 min. A bivariant optimization method for the mobile phase SDS–tetrahydrofuran corroborated the above results. The effect of temperature on the retention was also studied, and 50°C was selected. The optimized method was applied to human urine samples of subjects administered Diurex® (tablets containing 20 mg of the active ingredient xipamide) without sample preparation.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method is described for the determination of apigenin and the 4′-methylated derivative acacetin in human urine using column-switching and ultraviolet (UV) absorbance detection. Urine samples were enzymatically hydrolysed and solid-phase extracted prior to injection onto the HPLC system. Prior to elution of apigenin and the internal standard, 5,7,8-trihydroxyflavone, from the first column used for sample clean-up, the six-port valve was switched to the second column for analysis with UV detection. Detection of apigenin was precise and reproducible, with a limit of quantification of 10 ng ml−1 urine. Detection and quantification of acacetin was linear down to 70 ng ml−1 urine. The method has been successfully applied to determine the level of apigenin in 100 human urine samples from an intervention study with parsley.  相似文献   

12.
A sensitive and selective method for the quantification of mycophenolate mofetil and its active metabolite mycophenolic acid in different human skin layers after dermal administration is presented. The skin layers were separated after in vitro penetration experiments and a methanolic extraction was performed. Positive ion electrospray HPLC–MS in selected ion monitoring mode was used to quantify the substances after isocratic separation by a C18 analytical column. The minimum detectable concentrations were 850 pg/ml for MMF and 1 ng/ml for MPA. The peak areas depended linearly on the concentration of both drugs over the range of 25–1000 ng/ml (r2≥0.996) with accuracy ≤9.8% and precision ≤13.2%. Total imprecision at quantification limits was 15.2% at 10 ng/ml and 16.3% at 1500 ng/ml for MMF and 15.1% at 21.0 ng/ml and 17.5% at 1300 ng/ml for MPA. This HPLC–MS method will be applicable to the profiling of MMF amounts in skin and its conversion to MPA after application of different formulations.  相似文献   

13.
A new high-performance liquid chromatograhic procedure for simultaneous determination of pyrazinamide (PZA) and its three metabolites 5-hydroxypyrazinamide (5-OH-PZA), pyrazinoic acid (PA), and 5-hydroxypyrazinoic acid (5-OH-PA), in rat urine was developed. 5-OH-PZA and 5-OH-PA standards were obtained by enzymatic synthesis (xanthine oxidase) and checked by HPLC and GC–MS. Chromatographic separation was achieved in 0.01 M KH2PO4 (pH 5.2), circulating at 0.9 ml/min, on a C18 silica column, at 22°C. The limits of detection were 300 μg/l for PZA, 125 μg/l for PA, 90 μg/l for 5-OH-PZA and 70 μg/l for 5-OH-PA. Good linearity (r2>0.99) was observed within the calibration ranges studied: 0.375–7.50 mg/l for PZA, 0.416–3.33 mg/l for PA, 0.830–6.64 mg/l for 5-OH-PZA and 2.83–22.6 mg/l for 5-OHPA. Accuracy was always lower than ±10.8%. Precision was in the range 0.33–5.7%. The method will constitute a useful tool for studies on the influence of drug interactions in tuberculosis treatment.  相似文献   

14.
A simple and sensitive HPLC method has been developed for the determination of marbofloxacin (MAR) in plasma. Sample preparations were carried out by adding phosphate buffer (pH 7.4, 0.1 M), followed by extraction with trichloromethane. MAR and the internal standard, enrofloxacin (ENR), were separated on a reversed-phase column and eluted with aqueous solution–acetonitrile (80:20). The fluorescence of the column effluent was monitored at λex=338 and λem=425 nm. The retention times were 2.20 and 3.30 min for MAR and ENR, respectively. The method was shown to be linear from 15 to 1500 ng/ml (r2=0.999). The detection limit was 15 ng/ml. Mean recovery was determined as 90% by the analysis of plasma standards containing 150, 750, and 1500 ng/ml. Inter- and intra-assay precisions were 3.3% and 2.7%, respectively.  相似文献   

15.
Compound I, 5-chloro-3-(4-methanesulfonylphenyl)-6′-methyl-[2,3′]bipyridinyl, has been found to be a specific inhibitor of the enzyme cyclooxygenase II (COX II). The anti-inflammatory properties of this compound are currently being investigated. HPLC assays for the determination of this analyte in human plasma and human urine have been developed. Isolation of I and the internal standard (II) was achieved by solid-phase extraction (SPE) in the 96-well format. A C8 SPE plate was used for the extraction of the drug from human plasma (recovery >90%) while a mixed-mode (C8/Cation) SPE plate was used to isolate the analytes from human urine (recovery approximately 71%). The analyte and internal standard were chromatographed on a Keystone Scientific Prism-RP® guard column (20×4.6 mm) connected to a Prism-RP® analytical column (150×4.6 mm), using a mobile phase consisting of 45% acetonitrile in 10 mM acetate buffer (pH=4); the analytes eluted at retention times of 5.2 and 6.9 min for I and II, respectively. Compounds I and II were found to form highly fluorescent products after exposure to UV light (254 nm). Thus, the analytes were detected by fluorescence (λex=260 nm, λem=375 nm) following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 5–500 ng/ml for human plasma and human urine yielded a linear response (R2>0.99) when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n=5) of spiked standards, the within-day precision for both assays was better than 7% C.V. at all points on the calibration curve; within-day accuracy was within 5% of nominal at all standard concentrations. The between-run precision and accuracy of the assays, as calculated from the results of the analysis of quality control samples, was better than 8% C.V. and within 8% of nominal. I was found to be stable in human plasma and urine for at least 8 and 2 months, respectively. In addition, the human plasma assay was semi-automated in order to improve sample throughput by utilizing a Packard liquid handling system and a Tom-Tec Quadra 96 SPE system. The precision and accuracy of the semi-automated procedure were comparable to the manual procedure. Over 5000 clinical samples have been analyzed successfully using these methods.  相似文献   

16.
An HPLC method for the direct and simultaneous determination of estriol 3- and 16-glucuronides in pregnancy urine is described. The method is based on direct derivatization of the glucuronic acid moiety in estriol glucuronides in urine with 6,7-dimethoxy-1-methyl-2(1H)-quinoxalinone-3-propionylcarboxylic acid hydrazide. The derivatization reaction proceeds in aqueous solution (or urine sample) in the presence of pyridine and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide at 37°C. The resulting fluorescent derivatives were separated by column-switching chromatography using a first column (YMC-Pack C4) for clean-up of the derivatives and a second column (YMC Pack Ph) for the complete separation of the derivatives. The derivatives were detected spectrofluorimetrically at 445 nm with excitation at 367 nm. The detection limits (signal-to-noise ratio=3) for estriol 3- and 16-glucuronides were 150 and 180 fmol in a 5 μl of urine (14 and 17 ng ml−1 urine), respectively. The present method is highly sensitive and simple without any clean-up such as conventional solid-phase extraction.  相似文献   

17.
Various β2-agonists are used as illegal growth promoters in man and in animals. We developed a multiresidue procedure for the analysis of four β-agonists in human and calf urine. The sample was pre-extracted with an Extrelut column at alkaline pH. The β-agonists were eluted with a mixture of tert.-butylmethyl ether and hexane. Then the extract was further cleaned with a mixed mode SPE column, or with a combination of immunoaffinity chromatography (IAC) and the mixed mode SPE column. The IAC column contained antibodies against salbutamol, which were suitable for multiresidue extractions. The extract was then brought onto a mixed mode SPE column at an acidic pH. The column was washed with 70% methanol in water. Thereafter, the β-agonists were eluted with ammoniated ethanol–hexane. The extract was analysed with an HPLC method with electrochemical detection. The β-agonists were separated on a reversed-phase column using a mobile phase buffered at pH 5.5 and containing an ion-pair reagent. Recoveries were higher when the IAC procedure was not performed (90–105% vs. 65–75%), but the extracts were cleaner when the latter step was included. Detection limits in human and calf urine were in the low ng/ml range. The study indicated that β2-agonists can be analysed in human and calf urine without the selectivity of a mass spectrometer, but that comprehensive clean-up is required to avoid the interference of urine matrix components.  相似文献   

18.
Human biotransformation of the industrial solvent N,N-dimethylformamide gives raise to N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC) which has the longest half-life (about 23 h) among urinary metabolites of N,N-dimethylformamide. It could be used for monitoring industrial exposure over several workdays, by measuring it in urine samples collected at the end of the working week. This is consistent with the suggestions of the American Conference of Governmental Industrial Hygienists, which established a limit of 40 mg/l for the year 2000. An easy, cheap and user-friendly method has been developed for determination of urinary AMCC. Unlike currently available methods, it requires neither a time-consuming preparation phase nor gas chromatographic analysis with a nitrogen-phosphorus or mass detector. The method uses high-performance liquid chromatography (HPLC), with an UV detector at 436 nm. A 10-μl volume of urine is added to a carbonate–hydrogen carbonate buffer and mixed with a dabsyl chloride solution in acetonitrile. The reaction between AMCC and the reagent is performed at 70°C for 10 min. The ‘dabsylated’ product is stable for at least 12 h. After brief centrifugation, the solution is ready for HPLC analysis using a C18 column (250×4.6 mm, 5 μm). The method is sensitive (detection limit 1.8 mg/l) and specific. It identified urinary AMCC in urine of 40 subjects not exposed to N,N-dimethylformamide with a median concentration of 3.9 mg/l. In urine samples from 20 workers exposed to N,N-dimethylformamide (5–40.8 mg/m3), AMCC concentrations ranged from 16 to 170 mg/l. Industrial toxicology laboratories with limited instrumentation will be able to use it in the biological monitoring of workers exposed to N,N-dimethylformamide.  相似文献   

19.
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 μl of plasma) and 25 ng/ml (50 μl of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.  相似文献   

20.
A high-performance liquid chromatographic method for the routine determination of elevated urinary levels of the serotonin metabolite 5-hydroxytryptophol (5-HTOL) is described. Urine samples were treated with β-glucuronidase, and 5-HTOL was isolated by solid-phase extraction on a small Sephadex G-10 column prior to injection onto an isocratically eluted C18 reversed-phase column. Detection of 5-HTOL was performed electrochemically at +0.60 V vs. Ag/AgCl. The limit of detection was ca. 0.05 μM, and the intra-assay coefficients of variation were below 6% with urine samples containing 0.2 and 2.1 μM 5-HTOL and a standard solution of 2.0 μM (n = 5). The recovery of 5-HTOL after the sample clean-up procedure was close to 100%. A good correlation (r2 = 0.97; n = 12) was obtained between the present method and a sensitive and specific gas chromatographic—mass spectrometric method. The total (free plus conjugated) 5-HTOL levels in urine were normally below 0.2 μM, but after an acute dose of alcohol they increased to 0.5–15 μM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号