首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Responses to exchange transfusion using red blood cells (RBCs) with normal and reduced flexibility were studied in the hamster window chamber model during acute moderate isovolemic hemodilution to determine the role of RBC membrane stiffness in microvascular perfusion and tissue oxygenation. Erythrocyte stiffness was increased by 30-min incubation in 0.02% glutaraldehyde solution, and unreacted glutaraldehyde was completely removed. Filtration pressure through 5-microm pore size filters was used to quantify stiffness of the RBCs. Anemic conditions were induced by two isovolemic hemodilution steps using 6% 70-kDa dextran to a hematocrit (Hct) of 18% (moderate hemodilution). The protocol continued with an exchange transfusion to reduce native RBCs to 75% of baseline (11% Hct) with either fresh RBCs (RBC group) or reduced-flexibility RBCs (GRBC group) suspended in 5% albumin at 18% Hct; a plasma expander (6% 70-kDa dextran; Dex70 group) was used as control. Systemic parameters, microvascular perfusion, capillary perfusion [functional capillary density (FCD)], and oxygen levels across the microvascular network were measured by noninvasive methods. RBC deformability for GRBCs was significantly decreased compared with RBCs and moderate hemodilution conditions. The GRBC group had a greater mean arterial blood pressure (MAP) than the RBC and Dex70 groups. FCD was substantially higher for RBC (0.81 +/- 0.07 of baseline) vs. GRBC (0.32 +/- 0.10 of baseline) and Dex70 (0.38 +/- 0.10 of baseline) groups. Microvascular tissue Po(2) was significantly lower for Dex70 and GRBC vs. RBC groups and the moderate hemodilution condition. Results were attributed to decreased oxygen uploading in the lungs and obstruction of tissue capillaries by rigidified RBCs, indicating that the effects impairing RBC flexibility are magnified at the microvascular level, where perfusion and oxygenation may define transfusion outcome.  相似文献   

2.
The hamster window chamber model was used to study systemic and microvascular hemodynamic responses to extreme hemodilution with low- and high-viscosity plasma expanders (LVPE and HVPE, respectively) to determine whether plasma viscosity is a factor in homeostasis during extreme anemic conditions. Moderated hemodilution was induced by two isovolemic steps performed with 6% 70-kDa dextran until systemic hematocrit (Hct) was reduced to 18% (level 2). In a third isovolemic step, hemodilution with LVPE (6% 70-kDa dextran, 2.8 cP) or HVPE (6% 500-kDa dextran, 5.9 cP) reduced Hct to 11%. Systemic parameters, cardiac output (CO), organ flow distribution, microhemodynamics, and functional capillary density, were measured after each exchange dilution. Fluorescent-labeled microspheres were used to measure organ (brain, heart, kidney, liver, lung, and spleen) and window chamber blood flow. Final blood and plasma viscosities after the entire protocol were 2.1 and 1.4 cP, respectively, for LVPE and 2.8 and 2.2 cP, respectively, for HVPE (baseline = 4.2 and 1.2 cP, respectively). HVPE significantly elevated mean arterial pressure and CO compared with LVPE but did not increase vascular resistance. Functional capillary density was significantly higher for HVPE [87% (SD 7) of baseline] than for LVPE [42% (SD 11) of baseline]. Increases in mean arterial blood pressure, CO, and shear stress-mediated factors could be responsible for maintaining organ and microvascular perfusion after exchange with HVPE compared with LVPE. Microhemodynamic data corresponded to microsphere-measured perfusion data in vital organs.  相似文献   

3.
The oxygen transport capacity of fluorocarbons was investigated in the hamster chamber window model microcirculation to determine the rate at which oxygen is delivered to the tissue in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Hydroxyethlyl starch (HES 200; 200 kDa molecular mass) was used as a plasma expander for two isovolemic hemodilutions performed with 10% HES 200 until a Hct of 65%. A third step reduced the Hct to 75% of baseline and was performed with either HES 200 or a 60% perfluorocarbon (PFC) emulsion. Comparisons of HES 200-only-hemodiluted animals versus 4.2 g/kg PFC emulsion-hemodiluted animals were made at 21% and 100% normobaric oxygen ventilation. It was found that systemic and microvascular oxygen delivery was 25% and 400% higher in the PFC animals compared with HES 200 animals, respectively, showing that PFCs deliver oxygen to the tissue when combined with hyperoxic ventilation in the present experiments, with no evidence of vasoconstriction or impaired microvascular function. Oxygen ventilation (100%) led to a positive base excess for the PFC group (5.5 +/- 2.5 mmol/l) versus a negative balance (-0.8 +/- 1.4 mmol/l) for the HES 200 group, suggesting that microvascular findings corresponded to systemic events.  相似文献   

4.
The oxygen transport capacity of phospholipid vesicles encapsulating purified Hb (HbV) produced with a Po(2) at which Hb is 50% saturated (P 50 ) of 8 (HbV(8)) and 29 mmHg (HbV(29)) was investigated in the hamster chamber window model by using microvascular measurements to determine oxygen delivery during extreme hemodilution. Two isovolemic hemodilution steps were performed with 5% recombinant albumin (rHSA) until Hct was 35% of baseline. Isovolemic exchange was continued using HbV suspended in rHSA solution to a total [Hb] of 5.7 g/dl in blood. P(50) was modified by coencapsulating pyridoxal 5'-phosphate. Final Hct was 11% for the HbV groups, with a plasma [Hb] of 2.1 +/- 0.1 g/dl after exchange with HbV(8) or HbV(29). A reference group was hemodiluted to Hct 11% with only rHSA. All groups showed stable blood pressure and heart rate. Arterial oxygen tensions were significantly higher than baseline for the HbV groups and the rHSA group and significantly lower for the HbV groups compared with the rHSA group. Blood pressure was significantly higher for the HbV(8) group compared with the HbV(29) group. Arteriolar and venular blood flows were significantly higher than baseline for the HbV groups. Microvascular oxygen delivery and extraction were similar for the HbV groups but lower for the rHSA group (P < 0.05). Venular and tissue Po(2) were statistically higher for the HbV(8) vs. the HbV(29) and rHSA groups (P < 0.05). Improved tissue Po(2) is obtained when red blood cells deliver oxygen in combination with a high- rather than low-affinity oxygen carrier.  相似文献   

5.
A surface-modified polyethylene glycol-conjugated human hemoglobin (MP4) and alpha alpha-cross-linked human hemoglobin (alpha alpha Hb) were used to restore oxygen carrying capacity in conditions of extreme hemodilution (hematocrit 11%) in the hamster window model preparation. Changes in microvascular function were analyzed in terms of effects on capillary pressure and functional capillary density (FCD). MP4, at 1.0 +/- 0.2 g/dl blood concentration, significantly lowered mean arterial pressure (MAP) below baseline (99.6 +/- 7.6 mmHg) to 82.4 +/- 6.9 mmHg (P < 0.05) and decreased of FCD to 70 +/- 9%. alpha alpha Hb caused a greater recovery in MAP to 94.4 +/- 6.2 mmHg and lowered FCD to 62 +/- 8%. However, differences between alpha alpha Hb and MP4 in FCD were not statistically significant. Capillary pressures were in the ranges of 17-21 mmHg for MP4 and 15-19 mmHg for alpha alpha Hb, with both significantly lower than baseline (P < 0.05). Pressure in 80-microm-diameter arterioles was significantly increased with alpha alpha Hb relative to MP4 (P < 0.05). These results were compared with previous findings on the relation between capillary pressure and FCD; they supported the concept of a relationship between FCD and capillary pressure. Measurement of changes in arteriolar diameter, microvascular blood flow, and FCD show that there was no statistical difference between using alpha alpha Hb and MP4 in extreme hemodilution. Microvascular resistance in arterioles with a diameter range of 70-80 microm showed an increase relative to control with alpha alpha Hb, whereas MP4 caused a decrease.  相似文献   

6.
The rate of oxygen release from arterioles ( approximately 55 microm diameter) was measured in the hamster window chamber model during flow and no-flow conditions. Flow was stopped by microvascular transcutaneous occlusion using a glass pipette held by a manipulator. The reduction of the intra-arteriolar oxygen tension (Po2) was measured by the phosphorescence quenching of preinfused Pd-porphyrin, 100 microm downstream from the occlusion. Oxygen release from arterioles was found to be 53% greater during flow than no-flow conditions (2.6 vs. 1.7 x 10(-5) ml O2.cm(-2).s(-1), P < 0.05). Acute hemodilution with dextran 70 was used to reduce vessel oxygen content, significantly increase wall shear stress (14%, P < 0.05), reduce Hct to 28.4% (SD 1.0) [vs. 48.8% (SD 1.8) at baseline], lower oxygen supply by the arterioles (10%, P < 0.05), and increase oxygen release from the arterioles (39%, P < 0.05). Hemodilution also increased microcirculation oxygen extraction (33% greater than nonhemodilution, P < 0.05) and oxygen consumption by the vessel wall, as shown by an increase in vessel wall oxygen gradient [difference in Po2 between the blood and the tissue side of the arteriolar wall, nonhemodiluted 16.2 Torr (SD 1.0) vs. hemodiluted 18.3 Torr (SD 1.4), P < 0.05]. Oxygen released by the arterioles during flow vs. nonflow was increased significantly after hemodilution (3.6 vs. 1.8 x 10(-5) ml O2.cm(-2).s(-1), P < 0.05). The oxygen cost induced by wall shear stress, suggested by our findings, may be >15% of the total oxygen delivery to tissues by arterioles during flow in this preparation.  相似文献   

7.
Orthogonal polarization spectral (OPS) imaging is a new technique that can be used to visualize the microcirculation with reflected light. It uses hemoglobin absorption to visualize the red blood cells (RBCs). Thus the method could fail at low hematocrit (Hct). The aim of this study was to validate OPS imaging for quantitative measurements of diameter and functional capillary density (FCD) under conditions of hemodilution of varying degrees to achieve a wide range of Hcts. The validation was performed in the dorsal skinfold chamber of nine awake Syrian golden hamsters. Measurements of vessel diameter and FCD were performed off-line using Cap-Image on video sequences captured using OPS imaging and standard intravital fluorescence microscopy at baseline, 85, 70, 55, and 40% of the initial Hct. For hemodilution, isovolumic exchange of blood for 6% Dextran 60 was performed. Bland-Altman plots for the vessel diameter and FCD show good agreement between the two methods for both parameters at all studied Hcts. As expected, there was a systematic bias of approximately 4 microm in the diameter measurements since the RBC column was measured and not the intravascular diameter. In conclusion, OPS imaging can be used to measure diameter and FCD at a wide range of Hcts.  相似文献   

8.
The aim of this study was to test whether oxygenation in acutely ischemic, collateralized tissue may be improved by normovolemic hemodilution with a solution containing liposome-encapsulated human Hb (HbV). A skin flap model in anesthetized hamsters was used, which consisted of two parts receiving either anatomic or collateral perfusion. Microhemodynamics were investigated with intravital microscopy. Partial tissue oxygen tension was measured with a Clark-type microprobe. Hemodilution was obtained by exchanging 50% of the total blood volume with HbV suspended in 8% human serum albumin (HSA8) or 6% Dextran 70 (Dx70). The size of the vesicles was 276 nm, the P(50) was 22 mmHg, and the Hb concentration of the solutions was 7.5 g/dl. Colloid osmotic pressure and viscosity were 49.9 mmHg and 8.7 cP for HbV-Dx70 and 40.0 mmHg and 2.9 cP for HbV-HSA8, respectively. Hemodilution with HbV-Dx70 led to an increase in microvascular blood flow in the ischemic microvessels to maximally 158% (median, P < 0.01), whereas blood flow remained virtually unchanged after hemodilution with HbV-HSA8. In the ischemic tissue, oxygen tension was improved from 11.9 to 17.0 mmHg (P < 0.01) after hemodilution with HbV-Dx70 but remained virtually unchanged after hemodilution with HbV-HSA8. Our study suggests that the oxygenation in acutely ischemic, collateralized tissue may be improved by normovolemic hemodilution with HbV suspended in Dx70. The effect was achieved by an increase in microcirculatory blood flow related to the rheological properties of the suspending medium.  相似文献   

9.
Mathematical simulations of oxygen delivery to tissue from capillaries that take into account the particulate nature of blood flow predict the existence of oxygen tension (Po(2)) gradients between erythrocytes (RBCs). As RBCs and plasma alternately pass an observation point, these gradients are manifested as rapid fluctuations in Po(2), also known as erythrocyte-associated transients (EATs). The impact of hemodilution on EATs and oxygen delivery at the capillary level of the microcirculation has yet to be elucidated. Therefore, in the present study, phosphorescence quenching microscopy was used to measure EATs and Po(2) in capillaries of the rat spinotrapezius muscle at the following systemic hematocrits (Hct(sys)): normal (39%) and after moderate (HES1; 27%) or severe (HES2; 15%) isovolemic hemodilution using a 6% hetastarch solution. A 532-nm laser, generating 10-micros pulses concentrated onto a 0.9-microm spot, was used to obtain plasma Po(2) values 100 times/s at points along surface capillaries of the muscle. Mean capillary Po(2) (Pc(O(2)); means +/- SE) significantly decreased between conditions (normal: 56 +/- 2 mmHg, n = 45; HES1: 47 +/- 2 mmHg, n = 62; HES2: 27 +/- 2 mmHg, n = 52, where n = capillary number). In addition, the magnitude of Po(2) transients (DeltaPo(2)) significantly decreased with hemodilution (normal: 19 +/- 1 mmHg, n = 45; HES1: 11 +/- 1 mmHg, n = 62; HES2: 6 +/- 1 mmHg, n = 52). Results suggest that the decrease in Pc(O(2)) and DeltaPo(2) with hemodilution is primarily dependent on Hct(sys) and subsequent microvascular compensations.  相似文献   

10.
The oxygen transport capacity of nonhypertensive polyethylene glycol (PEG)-conjugated hemoglobin solutions were investigated in the hamster chamber window model. Microvascular measurements were made to determine oxygen delivery in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Two isovolemic hemodilution steps were performed with a 6% Dextran 70 (70-kDa molecular mass) plasma expander until Hct was 35% of control. Isovolemic blood volume exchange was continued using two surface-modified PEGylated hemoglobins (P5K2, P(50) = 8.6, and P10K2, P(50) = 8.3; P(50) is the hemoglobin Po(2) corresponding to its 50% oxygen saturation) until Hct was 11%. P5K2 and P10K2 are PEG-conjugated hemoglobins that maintain most of the hemoglobin allosteric properties and have a cooperativity index of n = 2.2. The effects of these molecular solutions were compared with those obtained in a previous study using MP4, a PEG-modified hemoglobin whose P(50) was 5.4 and cooperativity was 1.2 (Tsai et al., Am J Physiol Heart Circ Physiol 285: H1411-H1419, 2003). Tissue oxygen levels were higher after P5K2 (7.0 +/- 2.5 mmHg) and P10K2 (6.3 +/- 2.3 mmHg) versus MP4 (1.7 +/- 0.5 mmHg) or the nonoxygen carrier Dextran 70 (1.3 +/- 1.2 mmHg). Microvascular oxygen delivery was higher after P5K2 and P10K2 (2.22 and 2.34 ml O(2)/dl blood) compared with MP4 (1.41 ml O(2)/dl blood) or Dextran 70 (0.90 ml O(2)/dl blood); however, all these values were lower than control (7.42 ml O(2)/dl blood). The total hemoglobin in blood was similar in all cases; therefore, the improvement in tissue Po(2) and oxygen delivery appears to be due to the increased cooperativity of the new molecules.  相似文献   

11.
Isovolemic hemodilution to 11% systemic hematocrit was performed in the hamster window chamber model using 6% dextran 70 kDa (Dx 70) and 5% human serum albumin (HSA). Systemic and microvascular effects of these solutions were compared with polyethylene glycol (PEG)-conjugated 5% albumin (MPA) and PEG-conjugated 4.2% Hb (MP4). These studies were performed for the purpose of comparing systemic and microvascular responses of PEG vs. non-PEG plasma expanders and similar oxygen-carrying vs. noncarrying blood replacement fluids. Mean arterial blood pressure was statistically significantly reduced for all groups compared with baseline (P < 0.05), HSA, MPA, and MP4 higher than Dx 70 (P < 0.05). MP4 and MPA had a significantly higher cardiac index than HSA and Dx 70, in addition to a positive base excess. Microvascular blood flow and capillary perfusion were significantly higher for the PEG compounds compared with HSA and Dx 70. Intravascular PO2 for MP4 and MPA was higher in arterioles (P < 0.05) compared with HSA and Dx 70, but there was no difference in either tissue or venular PO2 between groups. Total Hb in the MP4 group was 4.8 +/- 0.4 g/dl, whereas the remaining groups had a range of 3.6-3.8 g/dl. The hemodilution results showed that PEG compounds maintained microvascular conditions with lower concentrations than conventional plasma expanders. Furthermore, microvascular oxygen delivery and extraction in the window chamber tissue were significantly higher for the PEG compounds. MP4 was significantly higher than MPA (P < 0.05) and was not statistically different from baseline, an effect due to the additional oxygen release to the tissue by the Hb MP4.  相似文献   

12.
We tested the hypothesis that high-viscosity (HV) plasma in extreme hemodilution causes wall shear stress to be greater than low-viscosity (LV) plasma, leading to enhanced production of nitric oxide (NO). The perivascular concentration of NO was measured in arterioles and venules and the tissue of the hamster chamber window model, subjected to acute extreme hemodilution, with a hematocrit (Hct) of 11% using Dextran 500 (n = 6) or Dextran 70 (n = 5) with final plasma viscosities of 1.99 +/- 0.11 and 1.33 +/- 0.04 cp, respectively. HV plasma significantly increased the periarteriolar, perivenular, and tissue NO concentration by 2.0, 1.9, and 1.4 times the control (n = 7). The NO concentration with LV plasma was not statistically different from control. Arteriolar shear stress was significantly increased in HV plasma relative to LV plasma in arterioles but not in venules. Aortic endothelial NO synthase (eNOS) protein expression was increased with HV plasma but not with LV plasma. There was a weak correlation between perivascular NO concentration and the locally calculated shear stress induced by the procedures, when blood viscosity was corrected according to Hct values previously determined in studies of microvascular Hct distribution. The finding that the periarteriolar and venular NO concentration in HV plasma was the same although arteriolar shear stress was significantly greater than venular shear stress maybe be due to differences in vessel wall metabolism between arterioles and venules and the presence of NO transport through the blood stream in the microcirculation. Results support the concept that in extreme hemodilution HV plasma maintains functional capillary density through a NO-mediated vasodilatation.  相似文献   

13.
14.
Extreme hemodilution was performed in the hamster chamber window model using 6% Dextran 70, lowering systemic hematocrit by 60%. Animals were subsequently divided into three groups and hemodiluted to a hematocrit of 11% using 6% Dextran 70, 6% Dextran 500, and a 4% Dextran 70 + 0.7% alginate solution (n = 6 each group). Final plasma viscosities were 1.4 +/- 0.2, 2.2 +/- 0.1, and 2.7 +/- 0.2 cp, respectively, (P < 0.05, high viscosity vs. low viscosity). Blood viscosities were 2.1 +/- 0.2, 2.9 +/- 0.4, and 3.9 +/- 0.3 cp, respectively. The lowest blood and plasma viscosity group had a significantly lower functional capillary density, 37 +/- 16%, whereas the two high-viscosity solutions were 71 +/- 15% and 76 +/- 12% (P < 0.05, high viscosity vs. low viscosity), respectively. Arteriolar and venular flow in the Dextran 500 and alginate groups was higher than baseline (i.e., normal nontreated animals), whereas the low-viscosity group showed a reduction in flow. These microvascular changes were paralleled by changes in base excess, which was negative for the Dextran 70 group and positive for the other groups. However, tissue Po(2) was uniformly low for all groups (average of 1.4 mmHg). Calculation of tissue oxygen consumption in the window chamber based on the microvascular data, flow, and intravascular Po(2) showed that only the alginate + Dextran 70 solution-exchanged animals returned to baseline oxygen consumption, whereas the other groups were lower than baseline (P < 0.05). These results show that hemodilution performed with high-viscosity plasma expanders yields systemic arterial pressures and functional capillary densities that are significantly higher (P < 0.05) than those obtained with 6% Dextran 70, a fluid whose viscosity is similar to that of plasma. A condition for obtaining these results is that the oncotic pressure of the plasma expander be titrated to near normal, so that autotransfusion of fluid from the tissue into the vascular compartment does not reduce the effects of increasing plasma viscosity and increased shear stress on the microvascular wall.  相似文献   

15.
The objective of the study was to investigate the effects of plasma viscosity after hemodilution on the thickness of the erythrocyte cell free layer (CFL) and on the interface between the flowing column of erythrocytes and the vascular endothelium. The erythrocyte CFL thickness was measured in the rat cremaster muscle preparation. Plasma viscosity was modified in an isovolemic hemodilution, in which the systemic hematocrit (Hctsys) was lowered to 30%. The plasma expanders (PE) of similar nature and different viscosities were generated by glutaraldehyde polymerization of human serum albumin (HSA) at various molar ratios glutaraldehyde to HSA: (i) unpolymerized HSA; (ii) PolyHSA24:1, molar ratio = 24 and (iii) PolyHSA60:1, molar ratio = 60. The HSA viscosities determined at 200 s(-1) were 1.1, 4.2 and 6.0 dyn x cm(-2), respectively. CFL thickness, vessel diameter and blood flow velocity were measured, while volumetric flow, shear rate and stress were calculated. Hemodilution with PolyHSA60:1 increased plasma viscosity and the blood showed marked shear thinning behavior. CFL thickness decreased as plasma viscosity increased after hemodilution; thus the CFL thickness with HSA and PolyHSA24:1 increased compared to baseline. Conversely, the CFL thickness of PolyHSA60:1 was not different from baseline. Blood flow increased with both PolyHSA's compared to baseline. Wall shear rate and shear stress increased for PolyHSA60:1 compared to HSA and PolyHSA24:1, respectively. In conclusion, PE viscosity determined plasma viscosity after hemodilution and affected erythrocyte column hydrodynamics, changing the velocity profile, CFL thickness, and wall shear stress. This study relates the perfusion caused by PolyHSA60:1 to hemodynamic changes induced by the rheological properties of blood diluted with PolyHSA60:1.  相似文献   

16.
The effect of small hematocrit (Hct) increases on cardiac index (cardiac output/body wt) and oxygen release to the microcirculation was investigated in the awake hamster window chamber model by means of exchange transfusions of homologous packed red blood cells. Increasing Hct between 8 and 13% from baseline increased cardiac index by 5-31% from baseline (P < 0.05) and significantly lowered systemic blood pressure (P < 0.05). The relationship between Hct and cardiac index is described by a second-order polynomial (R2 = 0.84; P < 0.05) showing that Hct increases up to 20% from baseline increase cardiac index, whereas increases over 20% from baseline decrease cardiac index. Combining this data with measurements of blood pressure allowed to determine total peripheral vascular resistance, which was a minimum at 8-13% Hct increase and was described by a second-order polynomial (R2 = 0.83; P < 0.05). Oxygen measurements in arterioles, venules, and the tissue at 8-13% Hct increase were identical to control; thus, as a consequence of increased flow and oxygen-carrying capacity, oxygen delivery and extraction increased, but the change was not statistically significant. Previous results with the same model showed that the observed effects are related to shear stress-mediated release of nitric oxide, an effect that should be also present in the heart microcirculation, leading to increased blood flow, myocardial oxygen consumption, and contractility. We conclude that a minimum viscosity level is necessary for generating the shear stress required for maintaining normal cardiovascular function.  相似文献   

17.
Hematocrit (Hct) of awake hamsters and CD-1 mice was acutely increased by isovolemic exchange transfusion of packed red blood cells (RBCs) to assess the relation between Hct and blood pressure. Increasing Hct 7-13% of baseline decreased mean arterial blood pressure (MAP) by 13 mmHg. Increasing Hct above 19% reversed this trend and caused MAP to rise above baseline. This relationship is described by a parabolic function (R2 = 0.57 and P < 0.05). Hamsters pretreated with the nitric oxide (NO) synthase (NOS) inhibitor N(omega)-nitro-L-arginine methyl ester (L-NAME) and endothelial NOS-deficient mice showed no change in MAP when Hct was increased by <19%. Nitrate/nitrite plasma levels of Hct-augmented hamsters increased relative to control and L-NAME treated animals. The blood pressure effect was stable 2 h after exchange transfusion. These findings suggest that increasing Hct increases blood viscosity, shear stress, and NO production, leading to vasodilation and mild hypotension. This was corroborated by measuring A1 arteriolar diameters (55.0 +/- 21.5 microm) and blood flow in the hamster window chamber preparation, which showed statistically significant increased vessel diameter (1.04 +/- 0.1 relative to baseline) and microcirculatory blood flow (1.39 +/- 0.68 relative to baseline) after exchange transfusion with packed RBCs. Larger increases of Hct (>19% of baseline) led blood viscosity to increase >50%, overwhelming the NO effect through a significant viscosity-dependent increase in vascular resistance, causing MAP to rise above baseline values.  相似文献   

18.
The effect of isovolemic hemodilution on the circulation of red blood cells (RBCs) in the cerebrocortical capillary network was studied by intravital videomicroscopy with use of a closed-cranial-window technique in the rat. Velocity and supply rate of RBCs were measured by tracking the movement and counting the number of fluorescently labeled cells. Arterial blood was withdrawn in increments of 2 ml and replaced by serum albumin. Arterial blood pressure was maintained constant with an infusion of methoxamine. Both velocity and supply rate of RBCs increased, by approximately equal amounts, as arterial hematocrit was reduced from 44 to 15%. The maximum increase in RBC velocity was 4.6 and in RBC supply rate was 5.2 times the baseline value. Calculated lineal density of RBC, an index of capillary hematocrit, did not change with hemodilution. The results suggest that RBC flow and oxygen supply in the cerebral capillary network are maintained during isovolemic hemodilution. The "optimal hematocrit" is as low as 15%.  相似文献   

19.
1. There is an exponential relationship between blood viscosity (cP) and hematocrit (%) for the bullfrog; eta = 1.81 e0.033Hct. The in vitro optimal hematocrit calculated for blood flow through tubes, from this relationship for bullfrog blood, is 30%. 2. Amphibian blood is a non-Newtonian fluid with viscosity dependent on shear rate. It has a finite yield shear stress of about 1.5 dynes cm-2. 3. Hematocrit of bullfrogs was increased from 27% (control) to 57% by isovolemic erythrocythemia (constant volume blood-doping). There was a slight increase in systolic, diastolic and venous blood pressure with elevated hematocrit. 4. Systemic arch blood flow rate was inversely related to blood viscosity for erythrocythemic bullfrogs. The decrease in systemic arch blood flow at high hematocrits was due primarily to reduced pulse volume rather than reduced heart rate. 5. Systemic arch blood flow, when standardised between individuals, was inversely related to blood viscosity; Qbl = 0.185 + 3.73 eta -1. This relationship was significantly different from that predicted by the Poiseuille-Hagen flow formula. The in vivo optimal hematocrit calculated from this relationship was 41%. 6. Optimal hematocrit theory appears to be generally applicable for Rana catesbeiana in vitro and in vivo. Most individuals had an in vivo optimal hematocrit, but the absence of a clear optimal hematocrit for some individuals could reflect methodological variability, or in vivo physiological compensation for the increased blood viscosity at high hematocrit.  相似文献   

20.
The aim of this study was to test the influence of oxygen affinity of Hb vesicles (HbVs) and level of blood exchange on the oxygenation in collateralized, ischemic, and hypoxic hamster flap tissue during normovolemic hemodilution. Microhemodynamics were investigated with intravital microscopy. Tissue Po2 was measured with Clark-type microprobes. HbVs with a P50 of 15 mmHg (HbV15) and 30 mmHg (HbV30) were suspended in 6% Dextran 70 (Dx70). The Hb concentration of the solutions was 7.5 g/dl. A stepwise replacement of 15%, 30%, and 50% of total blood volume was performed, which resulted in a gradual decrease in total Hb concentration. In the ischemic tissue, hemodilution led to an increase in microvascular blood flow to maximally 141-166% of baseline in all groups (median; P < 0.01 vs. baseline, not significant between groups). Oxygen tension was transiently raised to 121 +/- 17% after the 30% blood exchange with Dx70 (P < 0.05), whereas it was increased after each step of hemodilution with HbV15-Dx70 and HbV30-Dx70, reaching 217 +/- 67% (P < 0.01) and 164 +/- 33% (P < 0.01 vs. baseline and other groups), respectively, after the 50% blood exchange. We conclude that despite a decrease in total Hb concentration, the oxygenation in the ischemic, hypoxic tissue could be improved with increasing blood exchange with HbV solutions. Furthermore, better oxygenation was obtained with the left-shifted HbVs.  相似文献   