共查询到20条相似文献,搜索用时 15 毫秒
1.
Magali Ferrero Frdrique Spyratos Andre Desplaces Catherine Andrieu Edelmira Phillips Jacques Rouëss 《Biology of the cell / under the auspices of the European Cell Biology Organization》1989,65(3):305-308
Using four human tumor cell lines, MCF-7 and T47-D from breast tumors, MOLT-4 and K-562 from leukemia, flow cytometric DNA analysis of pure and mixed cell population was performed using monoclonal antibodies to cytokeratin to distinguish cytokeratin-containing carcinoma cells from leukemia cells which do not contain cytokeratins. Surprisingly, on pure or mixed K-562 cells, we found positive labeling with KL1, CK8, and CK18 antibodies (results confirmed by immunocytology). This preliminary study has allowed a DNA analysis on epithelial cells of human breast tumors. 相似文献
2.
Laser scanning cytometry (LSC) is a relatively new slide-based technology developed for commercial use by CompuCyte (Cambridge, MA) for performing multiple fluorescence measurements on individual cells. Because techniques developed for performing four or more measurements on individual lymphoid cells based on light scatter as a triggering parameter for cell identification are not suitable for the identification of fixed epithelial tumor cells, an alternative approach is required for the analysis of such cells by LSC. Methods for sample preparation, event triggering, and the performance of multiple LSC measurements on disaggregated fixed human cells were developed using normal lymphocytes and two human breast cancer cell lines, JC-1939 and MCF-7, as test populations. Optimal conditions for individual cell identification by LSC were found to depend on several factors, including deposited cell density (cells per unit area), the dynamic range of probe fluorescence intensities, and intracellular distribution of the fluorescent probe. Sparsely deposited cells exhibited the least cell overlap and the brightest immunofluorescent staining. Major advantages of using DNA probes over a cytoplasmic immunofluorescent protein marker such as tubulin for event triggering are that the former exhibit greater fluorescence intensity within a relatively sharply demarcated nuclear region. The DNA-binding dye LDS-751 was found to be suboptimal for quantitative DNA measurements but useful as a triggering measurement that permits the performance of simultaneous fluorescein isothiocyanate-, phycoerythrin-, and indodicarbocyanine-based measurements on each cell. A major potential advantage of LSC over flow cytometry is the high yields of analyzable cells by LSC, permitting the performance of multiple panels of multicolor measurements on each tumor. In conclusion, we have developed and optimized a technique for performing multiple fluorescence measurements on fixed epithelial cells by LSC based on event triggering using the DNA-binding dye LDS 751. Although not ideal for quantitative measurements of cell DNA content, the large Stokes shift of this dye permits the performance of three or more additional fluorescence measurements on each cell. 相似文献
3.
B K Seon K Yoshizaki D Pressman 《Journal of immunology (Baltimore, Md. : 1950)》1979,122(5):1951-1959
4.
DNA content analysis of insect cell lines by flow cytometry 总被引:1,自引:0,他引:1
The DNA content of insect cell lines (6 lepidoptera, 1 coleoptera and 1 diptera) was determined by flow cytometry. The DNA
profiles of the 8 cell lines tested were different. They were characterized by the presence of several peaks (2 to 7) corresponding
to different ploidy levels, by differences in the fluorescence intensity of each peak and by the proportion of cells in each
peak. Two cell lines (Cf124 and BmN) were constituted of 2 distinct populations of cells. The DNA profiles of the cell lines
were stable among the passages and during the length of time culture. This technique was demonstrated to be useful for the
detection of mixed cell lines and nucleopolyhedrovirus cell infection, using Autographa californica MNPV. The flow cytometry
gives interesting results on the cell cycle and the ploidy level; it appears as a good tool for insect cell lines characterization.
This revised version was published online in July 2006 with corrections to the Cover Date. 相似文献
5.
BACKGROUND: Naturally induced antibodies binding to surface antigens of Plasmodium falciparum-infected erythrocytes can be detected by direct agglutination of infected erythrocytes or by indirect immunofluorescence on intact, unfixed, infected erythrocytes. Agglutinating antibodies have previously been shown to recognise Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1). This protein is inserted by the parasite into the host cell membrane and mediates the adhesion to the venular endothelium of the host organism in vivo. METHODS: Erythrocytes infected at high parasitaemias with ethidium-bromide-labelled mature forms of P. falciparum parasites were sequentially exposed to immune plasma, goat anti-human immunoglobulin (Ig) G, and fluorescein-isothiocyanate-conjugated rabbit anti-goat Ig. Plasma antibodies recognising antigens exposed on the surface of parasitised erythrocytes were subsequently detected by two-colour flow cytometry. RESULTS: Binding of human antibodies to the surface of erythrocytes infected with adhesive strains of Plasmodium falciparum can be measured by the two-colour flow cytometry (FCM) assay described. In addition, we demonstrate that the adhesive capacity of a parasite isolate correlates with the capacity of human immune plasmas to label the isolate as detected by FCM. We also show that the antigens recognised by the labelling antibodies are strain specific and that their molecular weights are in the range previously described for PfEMP1 antigens. CONCLUSIONS: Our FCM assay predominantly detects antibodies that recognise PfEMP1 and thus constitutes a convenient assay for the analysis of acquisition, maintenance, and diversity of anti-PfEMP1-specific antibodies and for the examination of class and subclass characteristics. 相似文献
6.
A A Amoscato R M Sramkoski G F Babcock J W Alexander 《Biochimica et biophysica acta》1990,1041(3):317-319
Seven human tumor cell lines were studied for their neutral surface aminopeptidase (AP) activity. The activity was shown to exist on all cell lines to varying degrees. The neutral AP activity of the cell lines had similar Km values and were affected by the same inhibitors as those reported for AP's of peripheral blood lymphocytes (PBL, Refs. 1 and 2). However, a difference was seen in the Vmax values of the various cell lines. These values were shown to correlate (r = 0.767, P less than 0.05) with cell surface area. 相似文献
7.
Human immunodeficiency virus (HIV) infection heavily compromises the immune system. The decrease of the T cell CD4+ subset along the evolution to acquired immunodeficiency syndrome has been considered as a hallmark of HIV infection. In this paper we review some aspects of the immunopathology of HIV infection and discuss the importance of the flow cytometry for the evaluation of the T lymphocyte subsets in the follow-up of HIV infected children and adults, and for the monitoring of the immune reconstitution upon antiretroviral therapy. 相似文献
8.
HL-A antigens of human tumor-derived cell lines and viral transformed fibroblasts in culture 总被引:1,自引:0,他引:1
J H Kersey E J Yunis G J Todaro S A Aaronson 《Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine (New York, N.Y.)》1973,143(2):453-456
9.
Production of MUC1 and MUC2 mucins by human tumor cell lines. 总被引:2,自引:0,他引:2
P L Devine G T Layton B A Clark G W Birrell B G Ward P X Xing I F McKenzie 《Biochemical and biophysical research communications》1991,178(2):593-599
A mucus secreting, clonal derivative (HT29-SB) of the human colonic adenocarcinoma cell line HT29, and the LS174T colon cancer cell line, secrete mucin into the culture medium as a viscoelastic gel. Mab BC2, which defines a peptide epitope present in the variable number of tandem repeats (VNTR) of the MUC1 core protein, reacted with this material after deglycosylation. Two high molecular weight bands were detected in TFMSA treated gel-formed mucin from HT29-SB and LS174T by western blotting (Mr 580 kDa and 420 kDa). A similar pattern of reactivity was seen with the culture supernatants from HT29-SB, the ovarian tumor cell line COLO-316, and the breast cancer cell line MCF-7. Mab CCP58 (anti-MUC2 VNTR) reacted with a 580 kDa band in gel-formed mucin produced by LS174T, but was not reactive with mucin produced by the other cell lines. The findings indicate that human colonic cell lines, in addition to breast and ovarian cell lines, may both express and secrete the MUC1 protein core, and that the LS174T cell line expresses and secretes both the MUC1 and MUC2 core proteins. 相似文献
10.
Spleen cells from BALB/c females exposed to or neonatally infected with mammary tumor virus (MTV) are cytotoxic to MTV-induced mammary tumor cells in microcytotoxocity assay. This activity can be partially or completely blocked by pretreatment of spleen cells with MTV purified from milk. Murine leukemia virus (MuLV) has no effect. T cell responses of virgin and multiparous BALB/cfC3H females are effectively blocked. Non-T cell responses of multiparous BALB/cfC3H females or of virgin BALB/c females are blocked by some but not all of the MTV antigen preparations. MuLV, but not MTV, can block activity of spleen cells from MuLV-sensitized donors against target MuLV-producing tumor cells. 相似文献
11.
By indirect immunoelectron microscopy we tested for the presence of H-2 antigens on murine mammary tumor virus (MMTV) and murine leukemia virus (MuLV) particles. The association of H-2 antigens and viral antigens on the virus-infected cell surface was investigated with antibody-induced redistribution. Mammary tumor cells and leukemia cell lines with different H-2 genotypes and carrying different MuMTV or MuLV were used. No H-2 antigens could be demonstrated on the envelope of MMTV and MuLV particles, even after the permeabilization of their envelopes with saponin. On the surface of virus-infected cells antibody-induced patching or capping of the viral antigens did not result in copatching or cocapping of the H-2 antigens. In the reciprocal tests no co-redistribution of viral antigens with H-2 antigens was seen. Our experiments failed to show any physical association between H-2 antigens and MMTV or MuLV antigens on the cell surface.Abbreviations used in this paper MMTV
mammary tumor virus
- MuLV
murine leukemia virus
- MHC
major histocompatibility complex
- IEM
immunelectron microscopy 相似文献
12.
Simultaneous cell surface phenotype and cell cycle analysis of lymphocytes by flow cytometry 总被引:1,自引:0,他引:1
A method for the simultaneous measurement of cell surface components and nucleic acids (DNA and RNA) of human lymphocytes by flow cytometry has been developed, thereby providing a means of analyzing cell surface changes during the various phases of the cell cycle. Unfixed cells were coated with fluorescein-conjugated concanavalin A (F Con A) or surface antigen-specific antibody, fixed sequentially with paraformaldehyde and methanol, treated with specific nucleases, and then stained with propidium iodide. Neither portion of the procedure (cell surface staining, nucleic acid staining) interfered significantly with the other. Cell cycle phases of phytohemagglutinin-stimulated human lymphocytes as determined by this method were comparable with those identified by acridine orange staining. Cell cycle-specific blocking agents were used to additionally demonstrate the specificity of the staining procedure. Simultaneous measurement of cell cycle phase and detection of surface receptors for Con A and T lymphocyte surface determinants was performed with this method. 相似文献
13.
Afjehi-Sadat L Shin JH Felizardo M Lee K Slavc I Lubec G 《Biochimica et biophysica acta》2005,1747(1):67-80
14.
Detection of acid-beta-galactosidase activity in viable human fibroblasts by flow cytometry 总被引:3,自引:0,他引:3
The fluorogenic substrate fluorescein-di-beta-D-galactopyranoside was used to detect acid beta-galactosidase in intact cultured human fibroblasts. The accumulation of intracellular fluorescein, as measured by flow cytophotometry was linear with the incubation time in three control strains. The two fibroblast strains from patients with acid beta-galactosidase deficiency did not show an accumulation of intracellular fluorescence. Within one control cell population there was a positive correlation between the amount of accumulated intracellular fluorescein fluorescence and the specific acid beta-galactosidase activity as measured biochemically on sorted cells from different zones of the fluorescence distribution. No correlation was found between the specific acid beta-galactosidase activity and the fluorescein fluorescence of three different control cell strains. 相似文献
15.
Stefan Korec Ronald B. Herberman Jack H. Dean Grace B. Cannon 《Cellular immunology》1980,53(1):104-115
Purified peripheral blood granulocytes from normal adult donors were tested for cytolytic and cytostatic activity against a variety of tumor-derived, virus-transformed, and normal cell lines. Altogether, 45 donors and 16 cell lines were tested. Although granulocytes mediated antibody-dependent cell-mediated cytolysis, no spontaneous cytolysis, as measured by chromium-51 (51Cr) or [3H]thymidine ([3H]TdR) release could be detected in assays performed for up to 12 hr, even at an effector:target (E:T) cell ratio of 100:1. In contrast, granulocytes exhibited substantial growth-inhibitory activity (GIA) against most target cells, as measured by uptake of [3H]TdR by the target cells. These results were confirmed by visual counting of target cells. The degree of cytostasis was dependent on the E:T ratio, with a plateau of 80–95% inhibition usually reached at a ratio of 40:1. Inhibition of growth of adherent tumor target cells was accompanied by cell detachment, with both effects apparent by 5 hr and reaching a peak after 15 hr of incubation. With nonadherent targets, the onset and the peak of cytostasis were delayed, being observed after 8 and 24 hr, respectively. Growth of target cells remained inhibited for up to 4 days of culture. A wide variety of target cells were sensitive to granulocyte-mediated cytostasis, including tumor-derived human and mouse cell lines, lymphoblastoid cell lines from normal donors, and embryo fibroblasts. Normal human fibroblasts were inhibited only at high E:T ratios (40:1). PHA-induced lymphoblasts were the only target cells tested that were completely resistant to the cytostatic effects of granulocytes and in fact, their growth was slightly stimulated. There appeared to be two somewhat different mechanisms of growth inhibition by granulocytes, which varied with the target cell. Trypsinization of granulocytes markedly reduced their reactivity against adherent target cells but had little effect on GIA against suspension target cells. Also, the activity against F-265, but not against other target cells, was almost completely abrogated in the presence of catalase, suggesting an important role of hydrogen peroxide in one mechanism of granulocytemediated cytostasis. 相似文献
16.
17.
Rapid titration of retroviral vectors encoding intracellular antigens by flow cytometry. 总被引:2,自引:1,他引:2 下载免费PDF全文
Flow cytometry was used to detect cells infected with retroviral vectors encoding both simian virus 40 large T antigen and G418 resistance after indirect immunofluorescence staining using a T-antigen-specific monoclonal antibody and a fluorescein-conjugated secondary antibody. Titers of viral stocks determined by flow cytometry were equivalent to those determined by quantitation of G418-resistant colonies. 相似文献
18.
Detection of intracytoplasmic cytokines by flow cytometry 总被引:1,自引:0,他引:1
Santiago MA Luca PM Bertho AL Azeredo-Coutinho RB Coutinho SG 《Memórias do Instituto Oswaldo Cruz》2000,95(3):401-402
Flow cytometry has been used as a powerful technique for studying cell surface antigen expression as well as intracellular molecules. Its capability of analyzing multiple parameters simultaneously on a single cell has allowed identification and studies of functional cell subsets within heterogeneous populations. In this respect, several techniques have been developed during the past few years to study cytokine-producing cells by flow cytometry in humans and several animal models. 相似文献
19.
A new flow cytometer with a very small observation volume has been developed to detect individual viruses with good resolution, and has been used to discriminate between two types of viral particles based on differences in their light scattering. Measurements of light scattering and fluorescence made with such an instrument can provide a basis for quantitative analysis and sorting of viruses and other particles in the micron and submicron size range. 相似文献
20.
Summary Mycoplasma contamination of established cell lines is a well-known but often poorly controlled artefactual problem in immunological studies of human tumor cell lines. We have evaluated four methods for detecting mycoplasmas in cell lines, namely direct culture, DNA staining, uridine phosphorylase assay, and a fourth technique based on our finding that the supernatant medium of mycoplasma-infected cell cultures inhibits thymidine uptake of mitogen-stimulated peripheral blood lymphocytes. In our hands the simplest, most reliable, and least expensive means of monitoring cell cultures for mycoplasma proved to be DNA staining. The uridine phosphorylase assay was unsuitable for use with melanoma cell lines, as six of eight lines that were negative with the other three techniques were positive with this assay.Of 14 contaminated cell lines injected to nude mice, eitht produced tumors, five of which were shown to be mycoplasma-free after one to five passages, confirming the usefulness of this approach for salvaging contaminated cell lines. 相似文献