首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
R N Praihad 《Biorheology》1990,27(6):971-974
Some errors have been observed in the analytical expression for the resistance to flow (lambda R), and in the computation of shear stress distribution (tau R) in the analysis of Prawal Sinha and Chandan Singh (1). These errors have been rectified in the present analysis. Also, better values have been suggested for the couple stress parameter alpha for getting better results for lambda R and tau R.  相似文献   

2.
The effects of peripheral layer viscosity on physiological characteristics of blood flow through the artery with mild stenosis have been studied. It has been shown that the resistance to flow and the wall shear decrease as the peripheral layer viscosity decreases.  相似文献   

3.
The effect of the shape of stenosis on the resistance to blood flow through an artery with mild local narrowing has been studied. It is shown that the resistance to flow decreases as the shape of stenosis changes and the maximum resistance is attained in the case of symmetric stenosis.  相似文献   

4.
It has been shown that the resistance of flow and the wall shear increase with the size of the stenosis but these increases are comparatively small due to non-Newtonian behaviour of the blood indicating the usefulness of its rheological character in the functioning of the diseased arterial circulation.  相似文献   

5.
A generalized dispersion model is used to obtain exact solution for unsteady convective diffusion in the presence of couple stresses. The effect of the couple stress parameter 'a' on the most dominant dispersion coefficient is clearly depicted. The dimensionless mean concentration distribution is obtained as a function of dimensionless axial distance, time and 'a'. The results for 'pure convection' are also reported. It is shown that the effect of couple stress is predominant only for small values of 'a' and when a----infinity the flow characteristics tend to their equivalents in Newtonian theory. The results of Taylor's dispersion model are recovered as a particular case in the limit tau----infinity.  相似文献   

6.
Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.  相似文献   

7.
The objective of this paper is to study the mechanical effects caused by the local stiffening of an artery (due to the vascular prosthesis, for instance). At the junction of the host artery and the more rigid implantant, the abrupt change in compliance creates an abnormal stress concentration that initiates an adaptive response in the vascular tissue. The roles of both fluid and solid mechanical phenomena must be considered in the prosthesis design optimization. In this context, even the simple models could provide helpful tools for designing process. We present here a model of blood flow in compliant vessel. The artery is supposed to be an orthotropical thin elastic shell. We obtain the solution by matched asymptotic expansions. The results prove the high flexure concentration close to the compliance jump. It is shown that the use of orthotropical graft may reduce the peak value of these shear forces to a remarkable extent. Waves reflected from the suture and pressure increase in the prosthesis are discussed. Compliance mismatch is shown to reduce the peak value of maximal wall shear stress.  相似文献   

8.
This study is concerned with the surgical technique for the injection of a catheter through arteries with overlapping stenosis in the presence of externally applied magnetic field and Hall currents influences. The nature of blood is analyzed mathematically by considering it as a micropolar fluid. The analysis is carried out for an artery with a mild stenosis. The governing equations with the corresponding boundary conditions solved numerically using Crank–Nicolson implicit finite difference scheme. The numerical technique give excellent agreement for axial velocity of the fluid, the circumferential microrotation, the wall shear stress distribution and the contour plots of stream lines. The obtained results show that the value of axial velocity is higher for a Newtonian fluid than that for a micropolar fluid model, the effect of suitable moving magnetic field (Hall currents influences) accelerates the speed of blood, the size of trapped bolus for the stream lines decrease if the spinning movement of the fluid molecules have considerable value regardless of small or large size of the fluid molecules and the flow of fluid is better with increasing the Hall current effect and the size of trapping bolus increase clearly by increasing the maximum height of stenosis where the fluid moves as a bulk.  相似文献   

9.
In this paper, the behavior of a viscous fluid described by Newtonian constitutive theory is compared with that predicted by a model based on micropolar continuum theory. The geometry chosen for this comparative analysis is a stenosis in which gradient effects should be pronounced. A range of boundary conditions for fluid microspin are considered. Although velocities and streamlines are found to be similar for the two continuum models, striking differences in shear stresses are revealed. These differences may be as high as 50% for vanishing microspin boundary conditions. Such significant discrepancies highlight the need for further study of higher order modeling of blood flow.  相似文献   

10.
The effects of the viscosity-concentration dependence and of the concentration profile on blood flow through a vessel with stenosis have been studied. The flow resistance and the wall shear stress have been found to be smaller than in the two-fluid model with constant viscosities.  相似文献   

11.
12.
The laminar steady flow of non-Newtonian fluid (biviscosity fluid) through an axisymmetric stenosis is calculated using the finite element methods. The flow pattern, the separation and reattachment points, and the distributions of pressure and shear stress at the wall are obtained. Then, the axial force acting on the stenosis is evaluated. It is suggested by the authors that this force can become one of the causes of post-stenotic dilatation. Calculated results show that the non-Newtonian property of blood weakens the distortion of flow pattern, pressure and shear stress at the wall associated with the stenosis and that the non-Newtonian property of blood decreases the axial force acting on the stenosis.  相似文献   

13.
Mathematical modelling of flow through an irregular arterial stenosis.   总被引:2,自引:0,他引:2  
A mathematical model of flow through an irregular arterial stenosis is developed. The model is two-dimensional and axi-symmetric with the stenosis outline obtained from a three-dimensional casting of a mildly stenosed artery. Agreement between modelled and experimental pressure drops (obtained from an axi-symmetric machined stenosis with the same profile) is excellent. Results are also obtained for a smooth stenosis model, similar to that used for most mathematical modelling studies. This model overestimates the pressure drop across the stenosis, as well as the wall shear stress and separation Reynolds number. Also, the smooth model predicts one instead of three recirculation zones present in the irregular model. The original stenosis is modified to increase the severity from 48 and 87% areal occlusion, while maintaining the same general shape. This has the effect of increasing the pressure drop by an order of magnitude and decreasing the number of recirculation zones to one, with a lower separation Reynolds number.  相似文献   

14.
Steady laminar flow of a non-Newtonian fluid based on couple stress fluid theory, through narrow tubes of varying cross-sections has been studied theoretically. Asymptotic solutions are obtained for the basic equations and the expressions for the velocity field and the wall shear stress are derived for a general cross-section. Computation and discussions are carried out for the geometries which occur in the context of physiological flows or in particular blood flows. The tapered tubes and constricted tubes are of special importance. It is observed that increase in certain parameters results in erratic flow behaviour proximal to the constricted areas which is further enhanced by the increase in the geometric parameters. This elucidates the implications of the flow in the development of vascular lesions.  相似文献   

15.
A simple mathematical model depicting blood flow in the capillary is developed with an emphasis on the permeability property of the blood vessel based on Starling's hypothesis. In this study the effect of inertia has been neglected in comparison with the viscosity on the basis of the smallness of the Reynolds number of the flow in the capillary. The capillary blood vessel is approximated by a circular cylindrical tube with a permeable wall. The blood is represented by a couple stress fluid. With such an ideal model the velocity and pressure fields are determined. It is shown that an increase in the couple stress parameter increases the resistance to the flow and thereby decreases the volume rate flow. A comparison of the results with those of the Newtonian case has also been made.  相似文献   

16.
H Niimi  Y Kawano  I Sugiyama 《Biorheology》1984,21(4):603-615
A fine structure of blood flow through a curved vessel with an aneurysm was studied in in vitro experiments in relation to rheological factors of arterial diseases such as arteriosclerosis or thrombosis. On the basis of the in vivo data related to cerebral circulation, red blood cell suspension was flowed through curved vessel models with an asymmetrical aneurysm. Flow visualization was made with a microscope 16 mm cinecamera-TV monitor system, and the velocity profile was measured using the laser Doppler velocimeter. Vortices induced in aneurysm influenced flow structure and velocity at the presence of the secondary flow due to the vessel curvature. This suggests strongly that blood flow in curved arteries with an aneurysm must be understood under the influence of the secondary flow.  相似文献   

17.
Effects of histamine on bronchial artery blood flow and bronchomotor tone   总被引:5,自引:0,他引:5  
The effects of aerosolized 5% histamine (10 breaths) on bronchial artery blood flow (Qbr), airflow resistance (RL), and pulmonary and systemic hemodynamics were studied in mechanically ventilated sheep anesthetized with pentobarbital sodium. Histamine increased mean Qbr and RL to 252 +/- 45 and 337 +/- 53% of base line, respectively. This effect was significantly different from base line for 30 min after challenge. The histamine-induced increase in RL was blocked by pretreatment with the histamine H1 receptor antagonist, chlorpheniramine, whereas the histamine-induced elevation in Qbr was prevented by the H2 antagonist, metiamide. Both responses were blocked only when both antagonists were present. Changes in Qbr were not directly associated with alterations in systemic and pulmonary hemodynamics or arterial blood gas composition. In vitro histamine caused a dose-dependent contraction of ovine bronchial artery strips that was prevented by H1 antagonist. The H2 agonist, impromidine, caused relaxation of precontracted arterial strips and was more potent and efficacious than histamine, whereas H1 agonists failed to elicit a relaxant response. Thus these findings indicate that histamine aerosol induces a vasodilation in the bronchial vascular bed; histamine has a direct effect on Qbr that is independent of alterations in RL, systemic and pulmonary hemodynamics, or arterial blood gas composition; and, histamine-induced bronchoconstriction is mediated predominantly by H1-receptors, whereas increased Qbr is controlled predominantly by H2-receptors, probably located in resistance vessels. This local effect of histamine on Qbr may have important implications in the pathophysiology of bronchial asthma and pulmonary edema.  相似文献   

18.
Flow of couple stress fluid through stenotic blood vessels   总被引:3,自引:0,他引:3  
The effects of an axially symmetric mild stenosis on the flow of blood, when blood is represented by a couple stress fluid model, have been studied. It is found that, for a fixed stenosis size, the resistance to flow and wall shear stress increase as the couple stress parameter eta decreases from unity. A comparison of the results with those of the Newtonian case shows that the magnitude of resistance to flow and wall shear under a given set of conditions, is greater in the case of the couple stress fluid model. It is seen that even in the case of a mild stenosis (19% area reduction), resistance to flow and wall shear values are increased over those for no stenosis by 60% and 62%, respectively, when compared with the case of a Newtonian fluid.  相似文献   

19.
K Perktold  R Peter  M Resch 《Biorheology》1989,26(6):1011-1030
Blood flow is analysed by means of computer simulation in an idealized arterial bifurcation model which is pathologically altered by a saccular aneurysm. The theoretical study of the flow pattern and the paths of fluid particles is carried out under pulsatile Newtonian and non-Newtonian flow conditions. The governing equations are solved numerically with the use of the finite element method. The results show the disturbed blood flow in the bifurcation and the relatively low intra-aneurysmal flow circulation. In addition to the study of basic flow patterns in the segment, a comparison of non-Newtonian and Newtonian results is carried out. This comparison proves that for the considered large artery model under physiological flow conditions where the yield number is relatively low there is no essential difference in the results.  相似文献   

20.
The unsteady blood flow through an indented tube with atherosclerosis in the presence of mild stenosis has been studied numerically by finite difference method. The effects of hematocrit, frequency parameter, height of stenosis, parameter determining the shape of the constriction on velocity field, volumetric flow rate, pressure gradient of the fluid in stenotic region and wall shear stress at the surface of stenosis are obtained and shown graphically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号