首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sol-gel technique has been used for the covalent immobilization of the water-soluble mediator, thionin to construct a bulk modified, leak free composite electrode. This renewable composite electrode provides stable immobilization matrix for thionin via glutaraldehyde crosslinking. In the electrode composition the sol-gel precursor 3-aminopropyltrimethoxy silane serves as the host for immobilization of thionin, thereby preventing its leakage. An additional precursor methyl trimethoxy silane endows hydrophobicity and limits the wetting section of the modified electrode. Cyclic voltammetric characterization of the modified electrode in the potential range of 0.2 to -0.6 V exhibited stable redox peaks with a formal potential of -0.273 V, corresponding to immobilized thionin. This chemically modified electrode exhibits good electrocatalytic activity for the reduction of H(2)O(2) at a lower potential of -0.35 V. The reduction current of the modified electrode increases linearly in the range of 3.44 x 10(-6)M to 3.07 x 10(-3)M H(2)O(2) with a detection limit of 1.38 x 10(-6)M. The stable and quick response (5s) during chronoamperometry shows the potential application of the modified electrode for flow system analysis. The low potential operation (-0.35 V) favoured selective determination of H(2)O(2). The composite electrode exhibits distinct advantages of polishing in the event of surface fouling as well as simple preparation, good chemical and mechanical stability, economical and remarkable long-term stability (more than 1 year). The applicability of the present sensor for H(2)O(2) determination proposes a method for the detection of other biologically significant analytes.  相似文献   

2.
Poly(ionic liquid) (PIL) coated ordered mesoporous carbons (OMCs) were prepared by in situ polymerization of 3-ethyl-1-vinylimidazolium tetrafluoroborate ([VEIM]BF(4)) monomer on OMCs matrix. PIL on the surface of OMCs can provide sufficient binding sites to anchor the precursors of metal ion. PIL/OMCs were employed as support material for the deposition and formation of ultra-fine Pt nanoparticles, via the self-assembly between the negative Pt precursor and positively charged functional groups of PIL-functionalized OMCs. The combination of the unique properties of each component endows Pt/PIL/OMCs as a good electrode material. Compared with the Pt/OMCs nanocomposite, the Pt/PIL/OMCs modified electrode displays high electrocatalytic activity towards hydrogen peroxide (H(2)O(2)) and gives linear range from 1.0 × 10(-7) to 3.2 × 10(-3) M (R=0.999). The Pt/PIL/OMCs responds very rapidly to the changes in the level of H(2)O(2), producing steady-state signals within 4-5s. A high sensitivity of 24.43 μA mM(-1) and low detection limit of 0.08 μM was obtained at Pt/PIL/OMCs modified electrode towards the reduction of H(2)O(2). The improved activity makes Pt/PIL/OMCs nanocomposite promising for being developed as an attractive robust and new electrode material for electrochemical sensors and biosensors design.  相似文献   

3.
A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.  相似文献   

4.
Cui L  Yin H  Dong J  Fan H  Liu T  Ju P  Ai S 《Biosensors & bioelectronics》2011,26(7):3278-3283
An enzymeless biosensor was explored from Cu-Mg-Al calcined layered double hydroxide (CLDH) modified electrode in this study. The Cu-Mg-Al CLDH greatly promotes the electron transfer between H(2)O(2) and GCE, and it is exemplified toward the non-enzymatic sensing of H(2)O(2). The results indicate that the Cu-Mg-Al CLDH exhibits excellent electrocatalytic property, high sensitivity, good reproducibility, long-term stability, and fast amperometric response toward reduction of H(2)O(2), thus is promising for the future development of man-made mimics of enzyme in H(2)O(2) sensors. This work opens a way to utilize simply Cu-Mg-Al CLDH as an electron mediator to fabricate an efficient H(2)O(2) biosensor, which exhibits great potential applications in varieties of simple, robust, and easy-to-make analytical approaches in the future.  相似文献   

5.
A new highly catalytic and intensely sensitive amperometric sensor based on PtM (where M=Pd, Ir) bimetallic nanoparticles (NPs) for the rapid and accurate estimation of hydrogen peroxide (H(2)O(2)) by electrooxidation in physiological conditions is reported. PtPd and PtIr NPs-decorated multiwalled carbon nanotube nanocatalysts (PtM/MWCNTs) were prepared by a modified Watanabe method, and were characterized by XRD, TEM, ICP, and XAS. The sensors were constructed by immobilizing PtM/MWCNTs nanocatalysts in a Nafion film on a glassy carbon electrode. Both PtPd/MWCNTs and PtIr/MWCNTs assemblies catalyzed the electrochemical oxidation of H(2)O(2). Cyclic voltammetry characterization measurements revealed that both the PtM (M=Pd, Ir)/MWCNTs/GCE possessed similar electrochemical surface areas (~0.55 cm(2)), and electron transfer rate constants (~1.23 × 10(-3)cms(-1)); however, the PtPd sensor showed a better performance in H(2)O(2) sensing than did the PtIr counterpart. Explanations were sought from XAS measurements to explain the reasons for differences in sensor activity. When applied to the electrochemical detection of H(2)O(2), the PtPd/MWCNTs/GC electrode exhibited a low detection limit of 1.2 μM with a wide linear range of 2.5-125 μM (R(2)=0.9996). A low working potential (0V (SCE)), fast amperometric response (<5s), and high sensitivity (414.8 μA mM(-1)cm(-2)) were achieved at the PtPd/MWCNTs/GC electrode. In addition, the PtPd/MWCNTs nanocatalyst sensor electrode also exhibited excellent reproducibility and stability. Along with these attractive features, the sensor electrode also displayed very high specificity to H(2)O(2) with complete elimination of interference from UA, AA, AAP and glucose.  相似文献   

6.
In this study, the Fe-based layered double hydroxides (Mg(3)Fe LDH) were used to immobilize heme proteins including hemoglobin (Hb), myoglobin (Mb) and horseradish peroxidase (HRP) for fabrication of heme/Mg(3)Fe LDH film on glassy carbon electrode (Mg(3)Fe-heme/GCE). The possible role of iron in framework of LDH to promote direct electron transfer (DET) of heme proteins was investigated using an LDH containing non-iron as a reference. Hb was selected as a model protein for studying the electrocatalytic activity of immobilized heme in LDH film. The Mg(3)Fe-Hb/GCE displayed an enhanced electrocatalytic reduction towards H(2)O(2). The biosensor showed a very low detection limit (0.036μM) and apparent Michaelis-Menten constant (7.98μM). This work outlines that Fe-based LDH modified electrode provides a promising platform for immobilization of heme proteins and development of sensitive biosensors.  相似文献   

7.
Horseradish peroxidase (HRP) was successfully immobilized on vertically oriented TiO(2) nanotube arrays (NTAs), which was prepared by a seeded-growth mechanism. The nanotubular structure of TiO(2) was characterized by scanning electron microscope (SEM). After encapsulated HRP on TiO(2) nanotube arrays, the direct electron transfer of HRP was observed. Owing to the redox reaction of electroactive center of HRP, the HRP/TiO(2) NTAs modified electrode exhibited a pair of quasi-reversible peaks with the peak-to-peak separation of 70mV and the formal potential of -0.122V (vs. SCE) in 0.2molL(-1) phosphate buffer solution (PBS, pH 7.0). The number of transference electron was 0.84 and the direct electron transfer (ET) constant (k(s)) was 3.82s(-1). The HRP/TiO(2) NTAs modified electrode displayed an excellent electrocatalytic performance for H(2)O(2) and the formal Michaelis-Menten constant (K(m)(app)) was 1.9mmolL(-1). The response currents had a good linear relation with the concentration of H(2)O(2) from 5.0x10(-7)molL(-1) to 1.0x10(-5)molL(-1) and 5.0x10(-5)molL(-1) to 1.0x10(-3)molL(-1), respectively.  相似文献   

8.
A novel inexpensive and simple amperometric biosensor, based on the immobilization of HRP into redox active [Zn-Cr-ABTS] layered double hydroxide, is applied to the determination of cyanide. The electrochemical transduction step corresponds to the reduction at 0.0 V of ABTS+* enzymatically formed in the presence of H2O2. The biosensor has a fast response to H2O2 (8s) with a linear range of 1.7 x 10(-9) to 2.1 x 10(-6) M and a sensitivity of 875 mA M(-1) cm(-2). The apparent Michaelis-Menten constant (KMapp) is 12 microM. The detection of cyanide is performed via its non competitive inhibiting action on the HRP/[Zn-Cr-ABTS] electrode. The concentration range of the linear response and the apparent inhibition constant (ki) are 5 x 10(-9) to 4 x 10(-8) and 1.4 x 10 (-7) M, respectively.  相似文献   

9.
Direct electrochemical and electrocatalytic behaviors of hemoglobin (Hb) immobilized on carbon paste electrode (CPE) by a silica sol-gel film derived from tetraethylorthosilicate (TEOS) were investigated for the first time. Hb/sol-gel film modified electrodes showed a pair of well-defined and nearly reversible cyclic voltammetric peaks for Hb Fe(III)/Fe(II) redox couple at about -0.312 V (versus Ag/AgCl) in a pH 7.0 phosphate buffer. The formal potential of Hb heme Fe(III)/Fe(II) couple varied linearly with the increase of pH in the range of 5.0-10.0 with a slope of 49.44 mV pH(-1), which suggests that a proton transfer is accompanied with each electron transfer (ET) in the electrochemical reaction. The immobilized Hb displayed the features of peroxidase and gave excellent electrocatalytic performance to the reduction of O2, NO2(-) and H2O2. The calculated apparent Michaelis-Menten constant was 8.98 x 10(-4)M, which indicated that there was a large catalytic activity of Hb immobilized on CPE by sol-gel film toward H2O2. In comparison with other electrodes, the chemically modified electrodes, used in this direct electrochemical study of Hb, are easy to be fabricated and rather inexpensive. Consequently, the Hb/sol-gel film modified electrode provides a convenient approach to perform electrochemical research on this kind of proteins. It also has potential use in the fabrication of the third generation biosensors and bioreactors.  相似文献   

10.
A novel electrochemical immunosensor for ultrasensitive detection of subgroup J of avian leukosis virus (ALVs-J) was designed by using graphene sheets (GS)-layered double hydroxides (LDHs) composites modified electrode with multifunctional Fe(3)O(4) core/Ni-Al LDHs shell (LDHs@Fe(3)O(4)) nanospheres as labels. At first, the GS-LDHs were used for the immunosensor platform for improving the electronic transmission rate as well as increasing the surface area to capture a large amount of primary antibodies (Ab(1)). After that, ferrocene (Fc), secondary antibodies (Ab(2)) and horseradish peroxidase (HRP) multifunctional LDHs@Fe(3)O(4) nanospheres were used as labels with high load amount and good biological activity. Subsequently, in presence of H(2)O(2), amplified signals were obtained by an electrochemical sandwich immunoassay protocol. To embody the signal amplification property of the protocol, the analytical properties of various immunosensor platform and labels were compared in detail. Under optimal conditions, the reduction peak currents of the electrochemical immunosensor were proportional to the ALVs-J concentration over the range from 10(2.32) to 10(5.50) TCID(50)/mL with a low detection limit (180 TCID(50)/mL, S/N=3). The resulting immunosensor also displayed a good selectivity, reproducibility and stability.  相似文献   

11.
Herein, we reported for the first time one step procedure for the preparation of cytochrome c (cyt c)-poly (5-amino-2-napthalenesulfonic acid) (PANS) modified glassy carbon electrode by cyclic voltammetrically (CV). Hereafter, we called the above modified electrode as cyt c-PANS electrode. The presence of cyt c on modified electrode was investigated with electrochemical quartz crystal microbalance (EQCM), CV, and superoxide radicals reaction studies. The reaction between cyt c in the modified electrode and superoxide radicals in solution, was exemplified by cyclic voltammetric measurements. Surface morphology of the modified electrode was investigated by using atomic force microscopy (AFM). The modified electrode showed a pair of well defined redox peak in PBS solution, pH 6.7. The modified electrode utilized for electrocatalytic reduction as well as amperometric determination of hydrogen peroxide (H(2)O(2)). The detection limit and linear range for H(2)O(2) were 5 and 50 microM to 7 mM, respectively.  相似文献   

12.
Direct electron transfer of immobilized horseradish peroxidase on gold colloid and its application as a biosensor were investigated by using electrochemical methods. The Au colloids were associated with a cysteamine monolayer on the gold electrode surface. A pair of redox peaks attributed to the direct redox reaction of horseradish peroxidase (HRP) were observed at the HRP/Au colloid/cysteamine-modified electrode in 0.1 M phosphate buffer (pH 7.0). The surface coverage of HRP immobilized on Au colloid was about 7.6 x 10(-10) mol/cm(2). The sensor displayed an excellent electrocatalytic response to the reduction of H(2)O(2) without the aid of an electron mediator. The calibration range of H(2)O(2) was 1. 4 microM to 9.2 mM with good linear relation from 1.4 microM to 2.8 mM. A detection limit of 0.58 microM was estimated at a signal-to-noise ratio of 3. The sensor showed good reproducibility for the determination of H(2)O(2). The variation coefficients were 3. 1 and 3.9% (n = 10) at 46 microM and 2.8 mM H(2)O(2), respectively. The response showed a Michaelis-Menten behavior at higher H(2)O(2) concentrations. The K(app)(M) value for the H(2)O(2) sensor was found to be 2.3 mM.  相似文献   

13.
A method for recording O2 concentrations in nonconducting organic media with the Clark oxygen electrode was developed. Spontaneous oxidation of Na2S2O4 and the enzymatic reduction of NaBO3 or H2O2 by bovine liver catalase trapped in hydrated micelles of dioctylsulfosuccinate (AOT)/toluene were used as model systems. O2 titration with the above systems showed that air-saturated 1.6 M H2O/0.2 M AOT/toluene media contain seven times more O2 (1.4 mM) than aqueous solutions (0.2 mM). The measured Km values of catalase for NaBO3 and H2O2 in organic media were Kmov = 15 and 17 mM, respectively, whereas in aqueous buffer the values were 45 and 54 mM. In the toluene media, catalase activity increased with the W0 (H2O/AOT molar ratio) of the micellar preparation, reaching maximal activity at W0 = 10-12; under this condition, the catalytic center activity (Kp) of H2O2 was 7 x 10(6) min-1, similar to that obtained in the aqueous buffer (H2O2 = 7 x 10(6) min-1). It was found that the optimal pH for catalase in toluene media (pH 8.0) was shifted 1.0 unit compared to that in the aqueous buffer (pH 7.0). On the other hand, catalase was severely inhibited by NaN3 in both media. Thus, polarography based on the Clark oxygen electrode seems to be an easy, rapid, and sensitive technique for studying enzyme reactions consuming or evolving O2 in apolar media.  相似文献   

14.
Wei N  Xin X  Du J  Li J 《Biosensors & bioelectronics》2011,26(8):3602-3607
The three-dimensionally ordered macroporous gold-nanoparticle-doped titanium dioxide (3DOM GTD) film was modified on the indium-tin oxide (ITO) electrode surface. Hemoglobin (Hb) has been successfully immobilized on the 3DOM GTD film and the fabrication process was characterized by Raman and UV-vis spectra. The results indicated that the Hb immobilized on the film retained its biological activity and the secondary structure of Hb was not destroyed. The direct electrochemistry and electrocatalysis of Hb immobilized on this film have been investigated. The Hb/3DOM GTD/ITO electrode exhibited two couples of redox peaks corresponding to the Hb intercalated in the mesopores and adsorbed on the external surface of the film with the formal potential of -0.20 and -0.48 V in 0.1M PBS (pH7.0), respectively. The Hb/3DOM GTD/ITO electrode exhibits an excellent eletrocatalytic activity, a wide linear range for H(2)O(2) from 5.0 μM to 1.0mM with a limit of detection of 0.6μM, high sensitivity (144.5 μA mM(-1)), good stability and reproducibility. Compared with the TiO(2) nanoneedles modified electrode, the GTD modified electrode has higher sensitivity and response peak current. The 3DOM GTD provided a good matrix for bioactive molecules immobilization, suggesting it has the potential use in the fields of H(2)O(2) biosensors.  相似文献   

15.
Intercalation of horseradish peroxidase (HRP) into layered titanate by assembling it with titanate nano-sheets (TNS) was firstly used for fabrication of enzyme electrode (HRP-TNS electrode). XRD result revealed that HRP-TNS film featured layered structure with HRP monolayer intercalated between the titanate layers. UV-vis spectra result indicated the intercalated HRP in TNS film well retained its native structure. The HRP-TNS film was uniform with porous structures which were confirmed by SEM. The immobilized HRP in the TNS film exhibited fast direct electron transfer and showed a good electrocatalytic performance to H2O2 with high sensitivity, wide linear range and low detection. The excellent electrochemical performance of the HRP-TNS electrode was attributed to biocompatibility of the titanate sheets, porous architectures of the HRP-TNS film which retained activity of HRP to large extent, avoided aggregation of HRP, provided better mass transport and allowed more HRP loading per unit area. Thus, the simple method described here provides a novel and effective platform for immobilization of enzyme in realizing direct electrochemistry and has a promising application in fabrication of the third-generation electrochemical biosensors.  相似文献   

16.
Direct electrochemistry and thermal stability of hemoglobin (Hb) immobilized on a nanometer-sized zirconium dioxide (ZrO2) modified pyrolytic graphite (PG) electrode were studied. The immobilized Hb displayed a couple of stable and well-defined redox peaks with an electron transfer rate constant of (7.90 +/- 0.93)s(-1) and a formal potential of -0.361 V (-0.12 V versus NHE) in 0.1M pH 7.0 PBS. Both nanometer-sized ZrO2 and dimethyl sulfoxide (DMSO) could accelerate the electron transfer between Hb and the electrode. Spectroscopy analysis of the Hb/ZrO2/DMSO film showed that the immobilized Hb could retain its natural structure. This modified electrode showed a high thermal stability up to 74 degrees C and an electrocatalytic activity to the reduction of hydrogen peroxide (H2O2) without the aid of an electron mediator. The electrocatalytic response showed a linear dependence on the H2O2 concentration ranging from 1.5 to 30.2 microM with a detection limit of 0.14 microM at 3sigma. The apparent Michaelis-Menten constant KMapp for H2O2 sensor was estimated to be (0.31 +/- 0.02) mM, showing a high affinity.  相似文献   

17.
The direct electrochemistry of horseradish peroxidase (HRP) on a novel sensing platform modified glassy carbon electrode (GCE) has been achieved. This sensing platform consists of Nafion, hydrophilic room-temperature ionic liquid (RTIL) and Au nanoparticles dotted titanate nanotubes (GNPs-TNTs). The composite of RTIL and GNPs-TNTs was immobilized on the electrode surface through the gelation of a small amount of HRP aqueous solution. The composite was characterized by transmission electron microscopy (TEM), powder X-ray diffraction (XRD) and infrared spectroscopy (IR). UV-Vis and IR spectroscopy demonstrated that HRP in the composite could retain its native secondary structure and biochemical activity. The HRP-immobilized electrode was investigated by cyclic voltammetry and chronoamperometry. The results from both techniques showed that the direct electron transfer between the nanocomposite modified electrodes and heme in HRP could be realized. The biosensor responded to H(2)O(2) in the linear range from 5×10(-6) to 1×10(-3) mol L(-1) with a detection limit of 2.1×10(-6) mol L(-1) (based on the S/N=3).  相似文献   

18.
A new film for the fabrication of an unmediated H2O2 biosensor   总被引:2,自引:0,他引:2  
A novel and stable film made from polyethylene glycol (PEG) on pyrolytic graphite (PG) electrode was presented in this paper for incorporating horseradish peroxidase (HRP) to study the direct electrochemistry of the enzyme. In PEG film, HRP showed a thin-layer electrochemistry behavior. The apparent standard potential (E degrees ') was -0.379 V versus SCE at pH 7.2. Moreover, the PEG-HRP modified electrode exhibited excellent electrocatalytical response to the reduction of H2O2 with a calibration range between 2.0 x 10(-6) and 6.0 x 10(-4) M and a good linear relation from 2.0 x 10(-6) to 1.0 x 10(-4) M, on which an unmediated H2O2 biosensor was based. The detection limit of 6.7 x 10(-7) M was estimated when the signal-to-noise ratio was 3. The relative standard deviation (R.S.D.) was 4.7% for six successive determinations at a concentration of 4.0 x 10(-5) M. The apparent Michaelis-Menten constant (Km app) of the sensor was found to be 1.38 mM. Epinephrine, dopamine, and ascorbic acid did not interfere with the sensitive determination of H2O2.  相似文献   

19.
In this work, the excellent catalytic activity of highly ordered mesoporous carbons (OMCs) to the electrooxidation of nicotinamide adenine dinucleotide (NADH) and hydrogen peroxide (H(2)O(2)) was described for the construction of electrochemical alcohol dehydrogenase (ADH) and glucose oxidase (GOD)-based biosensors. The high density of edge-plane-like defective sites and high specific surface area of OMCs could be responsible for the electrocatalytic behavior at OMCs modified glassy carbon electrode (OMCs/GE), which induced a substantial decrease in the overpotential of NADH and H(2)O(2) oxidation reaction compared to carbon nanotubes modified glassy carbon electrode (CNTs/GE). Such ability of OMCs permits effective low-potential amperometric biosensing of ethanol and glucose, respectively, at Nafion/ADH-OMCs/GE and Nafion/GOD-OMCs/GE. Especially, as an amperometric glucose biosensor, Nafion/GOD-OMCs/GE showed large determination range (500-15,000mumoll(-1)), high sensitivity (0.053nAmumol(-1)), fast (9+/-1s) and stable response (amperometric response retained 90% of the initial activity after 10h stirring of 2mmoll(-1) glucose solution) to glucose as well as the effective discrimination to the possible interferences, which may make it to readily satisfy the need for the routine clinical diagnosis of diabetes. By comparing the electrochemical performance of OMCs with that of CNTs as electrode material for the construction of ADH- and GOD-biosensors in this work, we reveal that OMCs could be a favorable and promising carbon electrode material for constructing other electrochemical dehydrogenase- and oxidase-based biosensors, which may have wide potential applications in biocatalysis, bioelectronics and biofuel cells.  相似文献   

20.
Highly sensitive amperometric enzyme immunosensors for human immunoglobulin G (IgG) were prepared on the basis of electrogenerated polytyramine (PTy, tyramine = p-(2-aminoethyl)-phenol) modified electrodes. Properties of PTy films changed depending on electrolysis conditions. On the basis of the found properties of the films, an effective IgG sensor was prepared: a PTy film was formed first from an acid solution on a Pt electrode, and the surface was further covered with a PTy film from an alkaline methanol solution to give a PTy doubly coated electrode on which anti-IgG was then immobilized. This electrode provided a large surface area with little non-specific adsorption of proteins. By means of the competitive enzyme immunoassay technique using glucose oxidase (GOD) labeled IgG conjugates, IgG was determined in the concentration range of c. 10 pg/ml-1 mg/ml from the oxidation current of H2O2 generated by the enzyme (GOD) reaction using the above IgG sensor. Also, an anti-IgG immobilized electrode, prepared by using a Pt electrode singly covered with a PTy film from an alkaline methanol solution, acted as an effective IgG sensor with a detection limit for IgG of c. 100 pg/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号