首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hollow nitrogen-doped carbon microspheres (HNCMS) as a novel carbon material have been prepared and the catalytic activities of HNCMS-modified glassy carbon (GC) electrode towards the electro-oxidation of uric acid (UA), ascorbic acid (AA) and dopamine (DA) have also been investigated. Comparing with the bare GC and carbon nanotubes (CNTs) modified GC (CNTs/GC) electrodes, the HNCMS modified GC (HNCMS/GC) electrode has higher catalytic activities towards the oxidation of UA, AA and DA. Moreover, the peak separations between AA and DA, and DA and UA at the HNCMS/GC electrode are up to 212 and 136 mV, respectively, which are superior to those at the CNTs/GC electrode (168 and 114 mV). Thus the simultaneous determination of UA, AA and DA was carried out successfully. In the co-existence system of UA, AA and DA, the linear response range for UA, AA and DA are 5-30 μM, 100-1000 μM and 3-75 μM, respectively and the detection limits (S/N = 3) are 0.04 μM, 0.91 μM and 0.02 μM, respectively. Meanwhile, the HNCMS/GC electrode can be applied to measure uric acid in human urine, and may be useful for measuring abnormally high concentration of AA or DA. The attractive features of HNCMS provide potential applications in the simultaneous determination of UA, AA and DA.  相似文献   

2.
The performance of a new glucose biosensor based on the combination of biocatalytic activity of glucose oxidase (GOx) with the electrocatalytic properties of CNTs and neutral red (NR) for the determination of glucose is described. This sensor is comprised of a multiwalled carbon nanotubes (MWNTs) conduit functionalized with NR and Nafion (Nf) as a binder and glucose oxidase as a biocatalyst. Neutral red was covalently immobilized on carboxylic acid groups of the CNTs via carbodiimide reaction. The functionalized MWNTs were characterized by microscopic, spectroscopic and thermal methods. The MWNT-NR-GOx-Nf nanobiocomposite was prepared by mixing the GOx solution with NR functionalized CNTs followed by mixing homogeneously with Nafion. The performance of the MWNT-NR-GOx-Nf nanobiocomposite modified electrode was examined by electrochemical impedance spectroscopy and cyclic voltammetry. The catalytic reduction of hydrogen peroxide liberated from the enzymatic reaction of glucose oxidase upon glucose with NR functionalized CNTs leads to the selective detection of glucose. The excellent electrocatalytic activity and the influence of nanobiocomposite film result in good characteristics such as low potential detection of glucose with a large determination range from 1 x 10(-8) to 1 x 10(-3)M with a detection limit of 3 x 10(-9)M glucose, a short response time (with 4s), good stability and anti-interferent ability. The improved electrocatalytic activity and stability made the MWNT-NR-GOx-Nf nanobiocomposite biosensor system a potential platform to immobilize different enzymes for other bioelectrochemical applications.  相似文献   

3.
Liu Q  Lu X  Li J  Yao X  Li J 《Biosensors & bioelectronics》2007,22(12):3203-3209
Because of their unique chemical, physical and electronic properties, Quantum dots (QDs) and carbon nanotubes (CNTs) are now extremely attractive and important nanomaterials in bioanalytical applications. In this work, CdTe QDs with the size of about 3 nm were prepared and a novel electrochemical biosensing platform of glucose based on CdTe/CNTs electrode was explored. This CdTe/CNTs electrode was prepared by first mixing CdTe QDs, CNTs, Nafion, and glucose oxidase (GOD) in appropriate amounts and then modifying this mixture on the glass carbon electrode (GC). Transmission electron microscopy (TEM) was used to observe the dispersion of CdTe QDs on carbon nanotubes and cyclic voltammetry (CV) was used to investigate the electrochemical behavior of the CdTe/CNTs electrode. A pair of well-defined quasi-reversible redox peaks of glucose oxidase were obtained at the CdTe/CNTs based enzyme electrode by direct electron transfer between the protein and the electrode. The immobilized glucose oxidase could retain bioactivity and catalyze the reduction of dissolved oxygen. Due to the synergy between the CdTe QDs and CNTs, this novel biosensing platform based on QDs/CNTs electrode responded even more sensitively than that based on GC electrode modified by CdTe QDs or CNTs alone. The inexpensive, reliable and sensitive sensing platform based on QDs/CNTs electrode provides wide potential applications in clinical, environmental, and food analysis.  相似文献   

4.
Electrocatalytic sensing of NADH using a hybrid thin film derived from multi-wall carbon nanotubes (CNTs), Nafion (Nf) polymer and electrogenerated redox mediator is described. The redox mediator was electrochemically generated by the oxidation of serotonin on the hybrid thin film modified glassy carbon electrode (GC/Nf-CNT). Controlled potential electrolysis of serotonin at 0.1 V in neutral solution results in the generation of the redox mediator 5,5'-dihydroxy-4,4'-bitryptamine (DHB) on the hybrid thin film. The electrogenerated DHB has redox active quinone-imine structure and was electrochemically characterized by studying the pH dependent redox response. DHB on the hybrid thin film exhibits reversible redox peak at -0.05 V and the formal potential shifts by -55 mV while increasing the solution pH by 1 unit. The quinone-imine structure of DHB efficiently catalyzes the oxidation of NADH with a decrease in the overpotential of about 500 mV compared to the unmodified electrode. The CNTs of the hybrid thin film facilitates the mediated electrocatalytic oxidation of NADH. The hybrid thin film modified electrode exhibits stable amperometric response and it linearly responds to NADH (0.5-400 microM). This hybrid thin film modified electrode could detect NADH as low as 0.1 microM at -0.05 V with a sensitivity of 11.1 nA/microM in physiological pH.  相似文献   

5.
An electrochemical biosensor based on a glassy carbon (GC) electrode chemically modified with the perfluorinated cation-exchange polymer Nafion and methyl viologen (MV) is described. The enzyme was immobilized by cross-linking with glutaraldehyde in the presence of bovine serum albumin (BSA), methyl viologen and Nafion. Operating variables such as the enzyme/BSA ratio, cross-linking time in glutaraldehyde vapor, methyl viologen and Nafion percentages were investigated with regard to their influence on the biosensor sensitivity by using glucose oxidase as the enzyme model due to its high stability and low cost. The glutamate biosensor was elaborated by using optimized parameters and its electrochemical properties were investigated by cyclic voltammetry, amperometry and by electrochemical impedance spectroscopy. The glutamate biosensor shows a detection limit of 20 microM and a linear range extended to 0.75 mM. Its selectivity was tested with 15 different amino acids, each with a concentration of 20 microM, 25 microM acetaminophen, 20 microM uric acid and 200 microM ascorbic acid. No amperometric response was observed for the interfering species. This good selectivity allows glutamate detection in biological media without previous separation of the analyte.  相似文献   

6.
Multilayer films of shortened multi-walled carbon nanotubes (MWNTs) are homogeneously and stably assembled on glassy carbon (GC) electrodes using layer-by-layer (LBL) method based on electrostatic interaction of positively charged poly(diallyldimethylammonium chloride) (PDDA) and negatively charged shortened MWNTs. The assembled MWNT multilayer films were studied with respect to the electrocatalytic activity toward ascorbic acid (AA) and dopamine (DA) and were further applied for selective determination of DA in the presence of AA. Scanning electron microscopy (SEM) used for characterization of MWNT films indicates that the assembled MWNTs are almost in a form of small bundles or single nanotubes on the electrodes. Cyclic voltammetric results with assembled MWNT electrode indicate that the strategy based on the LBL method for assembling the MWNT multilayer films on substrate well retains the electrochemical catalytic activity of the MWNTs toward AA and DA, offering some advantages particularly attractive for analytical applications, such as the form of MWNTs assembled on the substrate, i.e., small bundles or single tubes, homogeneity and stability of the as-assembled MWNT films. These features make the assembled MWNTs relatively potential for selective and sensitive determination of DA in the presence of AA.  相似文献   

7.
A novel amperometric biosensor, based on electrodeposition of platinum nanoparticles onto multi-walled carbon nanotube (MWNTs) and immobilizing enzyme with chitosan-SiO(2) sol-gel, is presented in this article. MWNTs were cast on the glass carbon (GC) substrate directly. An extra Nafion coating was used to eliminate common interferents such as acetaminophen and ascorbic acids. The morphologies and electrochemical performance of the modified electrodes have been investigated by scanning electron microscopy (SEM) and amperometric methods, respectively. The synergistic action of Pt and MWNTs and the biocompatibility of chitosan-SiO(2) sol-gel made the biosensor have excellent electrocatalytic activity and high stability. The resulting biosensor exhibits good response performance to glucose with a wide linear range from 1 microM to 23 mM and a low detection limit 1 microM. The biosensor also shows a short response time (within 5s), and a high sensitivity (58.9 microAm M(-1)cm(-2)). In addition, effects of pH value, applied potential, rotating rate, electrode construction and electroactive interferents on the amperometric response of the sensor were investigated and discussed in detail.  相似文献   

8.
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated.  相似文献   

9.
Implantable and miniature carbon fiber microelectrode (CFME)-based third-generation biosensor for superoxide anion (O(2)(-)) was fabricated for the first time. The CFME-based biosensor was constructed by electro-deposition of Au nanoparticles on the CFMEs and then modification of the Au nanoparticles by cysteine followed by immobilization of superoxide dismutase (SOD) on the electrodes. The direct electrochemistry of the SOD immobilized on the CFME-based electrodes was efficiently realized by electron transfer promoter - cysteine molecules confined on the Au nanoparticles deposited on the CFMEs. The CFME-based biosensors were demonstrated to possess striking analytical properties for O(2)(-) determination, such as optional operation potentials, high selectivity and sensitivity as well as good stability. Along with the implantable capacity inherent in the CFMEs, these striking analytical properties of the CFME-based biosensors substantially make them potential for in vivo determination of O(2)(-).  相似文献   

10.
In this work, the excellent catalytic activity of highly ordered mesoporous carbons (OMCs) to the electrooxidation of nicotinamide adenine dinucleotide (NADH) and hydrogen peroxide (H(2)O(2)) was described for the construction of electrochemical alcohol dehydrogenase (ADH) and glucose oxidase (GOD)-based biosensors. The high density of edge-plane-like defective sites and high specific surface area of OMCs could be responsible for the electrocatalytic behavior at OMCs modified glassy carbon electrode (OMCs/GE), which induced a substantial decrease in the overpotential of NADH and H(2)O(2) oxidation reaction compared to carbon nanotubes modified glassy carbon electrode (CNTs/GE). Such ability of OMCs permits effective low-potential amperometric biosensing of ethanol and glucose, respectively, at Nafion/ADH-OMCs/GE and Nafion/GOD-OMCs/GE. Especially, as an amperometric glucose biosensor, Nafion/GOD-OMCs/GE showed large determination range (500-15,000mumoll(-1)), high sensitivity (0.053nAmumol(-1)), fast (9+/-1s) and stable response (amperometric response retained 90% of the initial activity after 10h stirring of 2mmoll(-1) glucose solution) to glucose as well as the effective discrimination to the possible interferences, which may make it to readily satisfy the need for the routine clinical diagnosis of diabetes. By comparing the electrochemical performance of OMCs with that of CNTs as electrode material for the construction of ADH- and GOD-biosensors in this work, we reveal that OMCs could be a favorable and promising carbon electrode material for constructing other electrochemical dehydrogenase- and oxidase-based biosensors, which may have wide potential applications in biocatalysis, bioelectronics and biofuel cells.  相似文献   

11.
This work shows excellent catalytic activity of soluble carbon nanofiber (CNF), which was obtained with a simple nitric acid treatment, toward the electroreduction of dissolved oxygen at a low operating potential. Thus the CNF was applied in the construction of amperometric biosensors for oxidase substrates using glucose oxidase as a model. The good dispersion of CNF led to convenient preparation and acceptable repeatability of the proposed sensors. UV-vis spectra, Fourier transform infrared spectra, X-ray photoelectron spectra and titration curves demonstrated that the good dispersion resulted from the large numbers of surface oxygen-rich groups produced in the treatment process. The membrane of CNF showed good stability and provided fast response to dissolved oxygen with a linear range from 0.1 to 78 microM and detection limit of 0.07 microM. The proposed glucose biosensor could monitor glucose ranging from 10 to 350 microM with detection limit of 2.5 microM and sensitivity of 36.3 nA cm(-2) microM(-1). The coefficients of variation for intra-assay were 4.7 and 3.2% at glucose concentrations of 20 and 210 microM, respectively. The use of a low operating potential (-0.3 V) and Nafion membrane produced good selectivity toward the glucose detection. CNF-based biosensors would provide wide range of bioelectrochemical applications in different fields.  相似文献   

12.
A novel Nafion/bacteria-displaying xylose dehydrogenase (XDH)/multi-walled carbon nanotubes (MWNTs) composite film-modified electrode was fabricated and applied for the sensitive and selective determination of d-xylose (INS 967), where the XDH-displayed bacteria (XDH-bacteria) was prepared using a newly identified ice nucleation protein from Pseudomonas borealis DL7 as an anchoring motif. The XDH-displayed bacteria can be used directly, eliminating further enzyme-extraction and purification, thus greatly improved the stability of the enzyme. The optimal conditions for the construction of biosensor were established: homogeneous Nafion-MWNTs composite dispersion (10 μL) was cast onto the inverted glassy carbon electrode, followed by casting 10-μL of XDH-bacteria aqueous solution to stand overnight to dry, then a 5-μL of Nafion solution (0.05 wt%) is syringed to the electrode surface. The bacteria-displaying XDH could catalyze the oxidization of xylose to xylonolactone with coenzyme NAD(+) in 0.1M PBS buffer (pH7.4), where NAD(+) (nicotinamide adenine dinucleotide) is reduced to NADH (the reduced form of nicotinamide adenine dinucleotide). The resultant NADH is further electrocatalytically oxidized by MWNTs on the electrode, resulting in an obvious oxidation peak around 0.50 V (vs. Ag/AgCl). In contrast, the bacteria-XDH-only modified electrode showed oxidation peak at higher potential of 0.7 V and less sensitivity. Therefore, the electrode/MWNTs/bacteria-XDH/Nafion exhibited good analytical performance such as long-term stability, a wide dynamic range of 0.6-100 μM and a low detection limit of 0.5 μM D-xylose (S/N=3). No interference was observed in the presence of 300-fold excess of other saccharides including D-glucose, D-fructose, D-maltose, D-galactose, D-mannose, D-sucrose, and D-cellbiose as well as 60-fold excess of L-arabinose. The proposed microbial biosensor is stable, specific, sensitive, reproducible, simple, rapid and cost-effective, which holds great potential in real applications.  相似文献   

13.
A poly(3-methylthiophene) modified glassy carbon electrode coated with Nafion/single-walled carbon nanotubes film was fabricated and used for highly selective and sensitive determination of dopamine. The hybrid film surface of the modified electrode was characterized by scanning electrochemical microscopy (SECM) and the results indicated that the carbon nanotubes were dispersed uniformly on the conductive polymer. The experimental results suggest that the hybrid film modified electrode combining the advantages of poly(3-methylthiophene), carbon nanotubes with Nafion exhibits dramatic electrocatalytic effect on the oxidation of dopamine (DA) and results in a marked enhancement of the current response. In 0.1M phosphate buffer solution (PBS) of pH 7.0, the differential pulse voltammetric (DPV) peak heights are linear with DA concentration in three intervals, viz. 0.020-0.10 microM, 0.10-1.0 microM and 1.0-6.0 microM, with correlation coefficients of 0.9993, 0.9996 and 0.9993, respectively. The detection limit of 5.0 nM DA could be estimated (S/N=3). Moreover, the interferences of ascorbic acid (AA) and uric acid (UC) are effectively diminished. This hybrid film modified electrode can be applied to the determination of DA contents in dopamine hydrochloride injection and human serum. These attractive features provide a potential application for either in vitro measurement of DA in the presence of excess AA and UA or as detectors in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).  相似文献   

14.
A high-performance bioanode based on the composite of carbon nanotubes (CNTs)-immobilized mediator and silk film (SF)-immobilized glucose oxidase (GOD) was developed for glucose/O(2) biofuel cell (BFC). Ferrocenecarboxaldehyde (Fc) was used as the mediator and covalently immobilized on the ethylenediamine (EDA)-functionalized CNTs (CNTs-EDA). GOD was cross-linked on the SF with glutaraldehyde (GA) as the cross-linking agent. The resulting electrode (CNTs-Fc/SF-GOD/glassy carbon (GC) electrode) exhibited good catalytic activity towards glucose oxidation and excellent stability. For the assembled glucose/O(2) BFC with the CNTs-Fc/SF-GOD/GC electrode as the bioanode and a commercial E-TEK Pt/C modified GC electrode as the cathode, the open circuit potential is 0.48 V and the maximum power density of 50.70 μW cm(-2) can be achieved at 0.15 V.  相似文献   

15.
Different strategies, including palladium electrodeposition (Pd(CV)), Pd sputtering (Pd(S)) and Nafion-solubilized carbon nanotube casting (Nafion/CNT), were used to modify screen-printed carbon electrodes (SPCEs) for the fabrication of amperometric enzyme biosensors. The electrochemical properties of the bare and modified SPCEs and the optimal conditions for surface modification were determined. The electrochemical response of the bare SPCE to H(2)O(2) under the potential of 0.3 V could be improved about 100-fold by Pd modification by electrodeposition or sputtering. By contrast, the electrochemical response of the bare SPCE was enhanced by only about 11-fold by Nafion/CNT casting. Moreover, the Pd(CV)-SPCEs exhibited better reproducibility of electrochemical response (a relative standard deviation (R.S.D.)<6.0%) than freshly prepared Pd(S)-SPCEs (R.S.D.>10%). The glucose biosensor fabricated from Pd-modified electrodes could be stored for up to 108 days without loosing significant activity. The Pd(CV)-SPCE also showed very reliable signal characteristics upon 50 consecutively repeated measurements of ascorbic acid. The electrocatalytic detection of the Pd-SPCE was combined with additional advantages of resistance to surface fouling and hence good stability. In conclusion, this study demonstrated that deposition of Pd thin film on SPCEs by electrodeposition or sputtering provided superior enhancement of electrochemical properties compared to Nafion/CNT-SPCEs. Despite their high electrochemical response, Pd(S)-SPCEs required an activation process to improve stability and Pd(CV)-SPCEs suffered from poor between electrode reproducibility.  相似文献   

16.
A label-free electrochemical immunosensor based on Nafion/carbon nanotubes (CNTs)/charged pyridinecarboxaldehyde composite film was developed for the detection of hepatitis B surface antigen. Nafion/CNTs/charged pyridinecarboxaldehyde nanocomposites were prepared by dispersing charged pyridinecarboxaldehyde and CNTs in Nafion solution. The nanocomposites were cast on the electrode surface to form aldehyde-terminated composite film that can covalently bind antibody on the film without using other reagent. The immunosensor response was linearly changed with hepatitis B surface antigen concentration in the range from 0.1 to 25 ng ml−1 with a detection limit (signal/noise ratio = 3) of 0.04 ng ml−1. Some important advantages such as simple preparation, good stability, reproducibility, and selectivity of the immunosensor were achieved.  相似文献   

17.
A biofunctional hybrid nanocomposite of carbon nanofiber (CNF) with water-soluble iron(III) meso-tetrakis(N-methylpyridinum-4-yl) porphyrin (FeTMPyP) was designed via non-covalent interaction for preparation of highly sensitive ethanol biosensor. The prepared nanocomposite showed good dispersion in water and was characterized with steady-state electronic absorption spectroscopy and scanning electron microscope. The nanocomposite combined the good conductivity of CNF and the excellent catalytic activity of both CNF and FeTMPyP toward the reduction of dissolved oxygen, producing a method for amperometric detection of oxygen ranging from 6.5 nM to 6.4 microM at a low overpotential. The nanocomposite modified electrode was further used for assembly of alcohol oxidase to construct an amperometric biosensor for ethanol. The biosensor showed rapid and highly sensitive response to ethanol with a linear range from 2.0 microM to 112 microM. The immobilized alcohol oxidase also showed its direct electrochemistry. The biofunctional nanocomposite provides a new way to not only construct the highly sensitive biosensors but also mimic the catalytic activity of enzyme in the life process.  相似文献   

18.
This paper describes highly stable enzyme precipitate coatings (EPCs) on electrospun polymer nanofibers and carbon nanotubes (CNTs), and their potential applications in the development of highly sensitive biosensors and high-powered biofuel cells. EPCs of glucose oxidase (GOx) were prepared by precipitating GOx molecules in the presence of ammonium sulfate, then cross-linking the precipitated GOx aggregates on covalently attached enzyme molecules on the surface of nanomaterials. EPCs-GOx not only improved enzyme loading, but also retained high enzyme stability. For example, EPC-GOx on CNTs showed a 50 times higher activity per unit weight of CNTs than the conventional approach of covalent attachment, and its initial activity was maintained with negligible loss for 200 days. EPC-GOx on CNTs was entrapped by Nafion to prepare enzyme electrodes for glucose sensors and biofuel cells. The EPC-GOx electrode showed a higher sensitivity and a lower detection limit than an electrode prepared with covalently attached GOx (CA-GOx). The CA-GOx electrode showed an 80% drop in sensitivity after thermal treatment at 50°C for 4 h, while the EPC-GOx electrode maintained its high sensitivity with negligible decrease under the same conditions. The use of EPC-GOx as the anode of a biofuel cell improved the power density, which was also stable even after thermal treatment of the enzyme anode at 50°C. The excellent stability of the EPC-GOx electrode together with its high current output create new potential for the practical applications of enzyme-based glucose sensors and biofuel cells.  相似文献   

19.
A novel hydrogen peroxide biosensor was fabricated by using a DNA-Cu(II) complex as a novel electrocatalyst for the reduction of hydrogen peroxide (H2O2). A polyion complex (PIC) membrane composed of DNA and poly(allylamine) (PAA) functioned as a support matrix for immobilization of electrocatalytic element-copper ion. The circular dichroism (CD) spectrum of the DNA-Cu(II)/PAA membrane in wet state showed that the DNA exists in B-like form within the membrane. Electrochemical measurements of the DNA-Cu(II)/PAA membrane-modified glassy carbon (GC) electrode revealed that the copper ion embedded in the DNA/PAA layer exhibits good electrochemical behaviors, and the electrochemical rate constant between the immobilized copper ion and the GC electrode surface was estimated to be 26.4 s(-1). The resulting DNA-Cu(II)/PAA/GC electrode showed an excellent electrocatalytic activity for the H2O2 reduction. The sensitivity of the sensor for the determination of H2O2 was affected by the amount of each component, such as copper ion, DNA and PAA in the DNA-Cu(II)/PAA membrane. Effects of applied potential, pH, temperature, ionic strength and buffer concentrations upon the response currents of the sensor were also investigated for an optimum analytical performance. Even in the presence of dissolved oxygen, the sensor exhibited highly sensitive and rapid (response time, less than 5 s) response to H2O2. The steady-state cathodic current responses of the sensor obtained at -0.2 V versus Ag/AgCl in air-saturated 50 mM phosphate buffer (pH 5.0) increased linearly up to 135 microM with the detection limit of 50 nM. Interference by ascorbic acid and uric acid due to the reduction of Cu(II) was effectively cancelled by further modification of outermost layer of polyion complex film. In addition, the sensor exhibited good reproducibility and stability.  相似文献   

20.
The multidrug resistance (MDR) in cancer is a major chemotherapy obstacle, rendering many currently available chemotherapeutic drugs ineffective. The aim of this study was to explore the new strategy to early diagnose the MDR by electrochemical sensor based on carbon nanotubes-drug supramolecular interaction. The carbon nanotubes modified glassy carbon electrodes (CNTs/GCE) were directly immersed into the cells suspension of the sensitive leukemia cells K562 and/or its MDR cells K562/A02 to detect the response of the electrochemical probe of daunorubicin (DNR) residues after incubated with cells for 1h. The fresh evidence from the electrochemical studies based on CNTs/GCE demonstrated that the homogeneous, label-free strategy could directly measure the function of cell membrane transporters in MDR cancer cells, identify the cell phenotype (sensitive or MDR). When the different ratios of the sensitive leukemia cells K562 and its MDR ones K562/A02 were applied as a model of MDR levels to simulate the MDR occurrence in cancer, the cathodic peak current showed good linear response to the fraction of MDR with a correlation coefficient of 0.995. Therefore, the MDR fraction can be easily predicted based on the calibration curve of the cathodic peak current versus the fraction of MDR. These results indicated that the sensing strategy could provide a powerful tool for assessment of MDR in cancer. The new electrochemical sensor based on carbon nanotubes-drug supramolecular nanocomposites could represent promising approach in the rapid diagnosis of MDR in cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号