共查询到20条相似文献,搜索用时 8 毫秒
1.
Alexander Ciritsis Daniel Truhn Nienke L. Hansen Jens Otto Christiane K. Kuhl Nils A. Kraemer 《PloS one》2016,11(5)
ObjectIn MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients.ResultsOn GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely “sufficient”.ConclusionBoth “positive contrast” techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient. 相似文献
2.
Purpose
To determine if applying an arrival time correction (ATC) to dynamic susceptibility contrast (DSC) based permeability imaging will improve its ability to identify contrast leakage in stroke patients for whom the shape of the measured curve may be very different due to hypoperfusion.Materials and Methods
A technique described in brain tumor patients was adapted to incorporate a correction for delayed contrast delivery due to perfusion deficits. This technique was applied to the MRIs of 9 stroke patients known to have blood-brain barrier (BBB) disruption on T1 post contrast imaging. Regions of BBB damage were compared with normal tissue from the contralateral hemisphere. Receiver operating characteristic (ROC) analysis was performed to compare the detection of BBB damage before and after ATC.Results
ATC improved the area under the curve (AUC) of the ROC from 0.53 to 0.70. The sensitivity improved from 0.51 to 0.67 and the specificity improved from 0.57 to 0.66. Visual inspection of the ROC curve revealed that the performance of the uncorrected analysis was worse than random guess at some thresholds.Conclusions
The ability of DSC permeability imaging to identify contrast enhancing tissue in stroke patients improved considerably when an ATC was applied. Using DSC permeability imaging in stroke patients without an ATC may lead to false identification of BBB disruption. 相似文献3.
4.
Kourosh Jafari-Khouzani Kyrre E. Emblem Jayashree Kalpathy-Cramer Atle Bj?rnerud Mark G. Vangel Elizabeth R. Gerstner Kathleen M. Schmainda Kamran Paynabar Ona Wu Patrick Y. Wen Tracy Batchelor Bruce Rosen Steven M. Stufflebeam 《Translational oncology》2015,8(3):137-146
OBJECTIVES
This study evaluates the repeatability of brain perfusion using dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a variety of post-processing methods.METHODS
Thirty-two patients with newly diagnosed glioblastoma were recruited. On a 3-T MRI using a dual-echo, gradient-echo spin-echo DSC-MRI protocol, the patients were scanned twice 1 to 5 days apart. Perfusion maps including cerebral blood volume (CBV) and cerebral blood flow (CBF) were generated using two contrast agent leakage correction methods, along with testing normalization to reference tissue, and application of arterial input function (AIF). Repeatability of CBV and CBF within tumor regions and healthy tissues, identified by structural images, was assessed with intra-class correlation coefficients (ICCs) and repeatability coefficients (RCs). Coefficients of variation (CVs) were reported for selected methods.RESULTS
CBV and CBF were highly repeatable within tumor with ICC values up to 0.97. However, both CBV and CBF showed lower ICCs for healthy cortical tissues (up to 0.83), healthy gray matter (up to 0.95), and healthy white matter (WM; up to 0.93). The values of CV ranged from 6% to 10% in tumor and 3% to 11% in healthy tissues. The values of RC relative to the mean value of measurement within healthy WM ranged from 22% to 42% in tumor and 7% to 43% in healthy tissues. These percentages show how much variation in perfusion parameter, relative to that in healthy WM, we expect to observe to consider it statistically significant. We also found that normalization improved repeatability, but AIF deconvolution did not.CONCLUSIONS
DSC-MRI is highly repeatable in high-grade glioma patients. 相似文献5.
6.
Peter P. Pott Markus L. R. Schwarz Ralf Gundling Kai Nowak Peter Hohenberger Eric D. Roessner 《PloS one》2012,7(10)
Background
Hernia repair is the most common surgical procedure in the world. Augmentation with synthetic meshes has gained importance in recent decades. Most of the published work about hernia meshes focuses on the surgical technique, outcome in terms of mortality and morbidity and the recurrence rate. Appropriate biomechanical and engineering terminology is frequently absent. Meshes are under continuous development but there is little knowledge in the public domain about their mechanical properties. In the presented experimental study we investigated the mechanical properties of several widely available meshes according to German Industrial Standards (DIN ISO).Methodology/Principal Findings
Six different meshes were assessed considering longitudinal and transverse direction in a uni-axial tensile test. Based on the force/displacement curve, the maximum force, breaking strain, and stiffness were computed. According to the maximum force the values were assigned to the groups weak and strong to determine a base for comparison. We discovered differences in the maximum force (11.1±6.4 to 100.9±9.4 N/cm), stiffness (0.3±0.1 to 4.6±0.5 N/mm), and breaking strain (150±6% to 340±20%) considering the direction of tension.Conclusions/Significance
The measured stiffness and breaking strength vary widely among available mesh materials for hernia repair, and most of the materials show significant anisotropy in their mechanical behavior. Considering the forces present in the abdominal wall, our results suggest that some meshes should be implanted in an appropriate orientation, and that information regarding the directionality of their mechanical properties should be provided by the manufacturers. 相似文献7.
Yen-Chu Huang Ho-Ling Liu Jiann-Der Lee Jen-Tsung Yang Hsu-Huei Weng Meng Lee Mei-Yu Yeh Yuan-Hsiung Tsai 《PloS one》2013,8(7)
Background
The aim of this study was to evaluate whether arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC) perfusion MRI.Methods
Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans within 30 hours after stroke onset and 31 patients underwent follow-up MRI scans. ASL cerebral blood flow (CBF) and DSC time to maximum (Tmax) maps were used to calculate the perfusion defects. The ASL CBF lesion volume was compared to the DSC Tmax lesion volume by Pearson''s correlation coefficient and likewise the ASL CBF and DSC Tmax lesion volumes were compared to the final infarct sizes respectively. A repeated measures analysis of variance and least significant difference post hoc test was used to compare the mean lesion volumes among ASL CBF, DSC Tmax >4–6 s and final infarct.Results
Mean patient age was 72.6 years. The average time from stroke onset to MRI was 13.9 hours. The ASL lesion volume showed significant correlation with the DSC lesion volume for Tmax >4, 5 and 6 s (r = 0.81, 0.82 and 0.80; p<0.001). However, the mean lesion volume of ASL (50.1 ml) was significantly larger than those for Tmax >5 s (29.2 ml, p<0.01) and Tmax >6 s (21.8 ml, p<0.001), while the mean lesion volumes for Tmax >5 or 6 s were close to mean final infarct size.Conclusion
Quantitative measurement of ASL perfusion is well correlated with DSC perfusion. However, ASL perfusion may overestimate the perfusion defects and therefore further refinement of the true penumbra threshold and improved ASL technique are necessary before applying ASL in therapeutic trials. 相似文献8.
9.
10.
11.
Current research on spoken language does not provide a consistent picture as to whether prosody, the melody and rhythm of speech, conveys a specific meaning. Perception studies show that English listeners assign meaning to prosodic patterns, and, for instance, associate some accents with contrast, whereas Dutch listeners behave more controversially. In two ERP studies we tested how Dutch listeners process words carrying two types of accents, which either provided new information (new information accents) or corrected information (corrective accents), both in single sentences (experiment 1) and after corrective and new information questions (experiment 2). In both experiments corrective accents elicited a sustained positivity as compared to new information accents, which started earlier in context than in single sentences. The positivity was not modulated by the nature of the preceding question, suggesting that the underlying neural mechanism likely reflects the construction of an interpretation to the accented word, either by identifying an alternative in context or by inferring it when no context is present. Our experimental results provide strong evidence for inferential processes related to prosodic contours in Dutch. 相似文献
12.
Aiping Yao Earl Zastrow Eugenia Cabot Bryn Lloyd Beatrice Schneider Wolfgang Kainz Niels Kuster 《Bioelectromagnetics》2019,40(7):458-471
The Virtual Population (ViP) phantoms have been used in many dosimetry studies, yet, to date, anatomical phantom uncertainty in radiofrequency (RF) research has largely been neglected. The objective of this study is to gain insight, for the first time, regarding the uncertainty in RF‐induced fields during magnetic resonance imaging associated with tissue assignment and segmentation quality and consistency in anatomical phantoms by evaluating the differences between two generations of ViP phantoms, ViP1.x and ViP3.0. The RF‐induced 10g‐average electric (E‐) fields, tangential E‐fields distribution along active implantable medical devices (AIMD) routings, and estimated AIMD heating were compared for five phantoms that are part of both ViP1.x and ViP3.0. The results demonstrated that differences exceeded 3 dB (?29%, +41%) for local quantities and 1 dB (±12% for field, ±25% for power) for integrated and volume‐averaged quantities (e.g., estimated AIMD‐heating and 10 g‐average E‐fields), while the variation across different ViP phantoms of the same generation can exceed 10 dB (?68% and +217% for field, ?90% and +900% for power). In conclusion, the anatomical phantom uncertainty associated with tissue assignment and segmentation quality/consistency is larger than previously assumed, i.e., 0.6 dB or ±15% (k = 1) for AIMD heating. Further, multiple phantoms based on different volunteers covering the target population are required for quantitative analysis of dosimetric endpoints, e.g., AIMD heating, which depend on patient anatomy. Phantoms with the highest fidelity in tissue assignment and segmentation should be used, as these ensure the lowest uncertainty and possible underestimation of exposure. To verify that the uncertainty decreases monotonically with improved phantom quality, the evaluation of differences between phantom generations should be repeated for any improvement in segmentation. Bioelectromagnetics. 2019;40:458–471. © 2019 Bioelectromagnetics Society 相似文献
13.
Janine Ring Verena Hoerr Lorena Tuchscherr Michael T. Kuhlmann Bettina L?ffler Cornelius Faber 《PloS one》2014,9(9)
Infective endocarditis (IE) is a severe and often fatal disease, lacking a fast and reliable diagnostic procedure. The purpose of this study was to establish a mouse model of Staphylococcus aureus-induced IE and to develop a MRI technology to characterize and diagnose IE. To establish the mouse model of hematogenous IE, aortic valve damage was induced by placing a permanent catheter into right carotid artery. 24 h after surgery, mice were injected intravenously with either iron particle-labeled or unlabeled S. aureus (strain 6850). To distinguish the effect of IE from mere tissue injury or recruited macrophages, subgroups of mice received sham surgery prior to infection (n = 17), received surgery without infection (n = 8), or obtained additionally injection of free iron particles to label macrophages (n = 17). Cardiac MRI was performed 48 h after surgery using a self-gated ultra-short echo time (UTE) sequence (TR/TE, 5/0.31 ms; in-plane/slice, 0.125/1 mm; duration, 12∶08 min) to obtain high-resolution, artifact-free cinematographic images of the valves. After MRI, valves were either homogenized and plated on blood agar plates for determination of bacterial titers, or sectioned and stained for histology. In the animal model, both severity of the disease and mortality increased with bacterial numbers. Infection with 105
S. aureus bacteria reliably caused endocarditis with vegetations on the valves. Cinematographic UTE MRI visualised the aortic valve over the cardiac cycle and allowed for detection of bacterial vegetations, while mere tissue trauma or labeled macrophages were not detected. Iron labeling of S. aureus was not required for detection. MRI results were consistent with histology and microbial assessment. These data showed that S. aureus-induced IE in mice can be detected by MRI. The established mouse model allows for investigation of the pathophysiology of IE, testing of novel drugs and may serve for the development of a clinical diagnostic strategy. 相似文献
14.
Cell-mediated immunity to antigens prepared from both serum and liver of patients positive for hepatitis-associated antigen (H.A.A.) was measured by using the leucocyte migration test. Altogether, 43 patients with H.A.A.-positive acute and chronic liver disease, eight with serum antibody to H.A.A., and 13 controls were studied. The cell-mediated immunity detected was specific for H.A.A. or other antigenic determinants of the associated infective agent and could be found only in patients with evidence of previous contact with H.A.A.Cell-mediated immunity to the H.A.A.-positive test antigens was found in all but one of the patients with acute hepatitis, in about half of the patients with chronic aggressive hepatitis or cirrhosis, rarely in those with chronic persistent hepatitis, and in none of the apparently healthy carriers.Our results support the hypothesis that the cellular immune response plays an important part in the clearance of the infective agent from H.A.A.-positive patients and in the pathogenesis of the associated liver cell injury. 相似文献
15.
16.
Daniel Grum Stefan Franke Oliver Kraff Dominik Heider Alexander Schramm Daniel Hoffmann Peter Bayer 《PloS one》2013,8(6)
Magnetic resonance imaging (MRI) offers a non-radioactive alternative for the non-invasive detection of tumours. Low molecular weight MRI contrast agents currently in clinical use suffer either from a lack of specificity for tumour tissue or from low relaxivity and thus low contrast amplification. In this study, we present the newly designed two domain fusion protein Zarvin, which is able to bind to therapeutic IgG antibodies suitable for targeting, while facilitating contrast enhancement through high affinity binding sites for Gd3+. We show that the Zarvin fold is stable under serum conditions, specifically targets a cancer cell-line when bound to the Cetuximab IgG, and allows for imaging with high relaxivity, a property that would be advantageous for the detection of small tumours and metastases at 1.5 or 3 T. 相似文献
17.
18.
19.
Bárbara Pérez-K?hler Francisca García-Moreno Thierry Brune Gemma Pascual Juan Manuel Bellón 《PloS one》2015,10(11)