首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Thermophysiological responses of heat production and heat loss were measured in seven adult volunteers (six males and one female, aged 31-74 years) during 45 min dorsal exposures of the whole body to 100 MHz continuous wave (CW) radio frequency (RF) energy. Three power densities (PD) (average PD = 4, 6, and 8 mW/cm(2); whole body specific absorption rate [SAR] = 0.068 [W/kg]/[mW/cm(2)]) were tested in each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C), as well as in T(a) controls (no RF). A standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline) was used. Measured responses included esophageal and seven skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow. No changes in metabolic heat production occurred under any test condition. Unlike published results of similar exposures at 450 and 2450 MHz, local skin temperatures, even those on the back that were irradiated directly, changed little or not at all during 100 MHz exposures. The sole exception was the temperature of the ankle skin, which increased by 3-4 degrees C in some subjects at PD = 8 mW/cm(2). During the 45 min RF exposure, esophageal temperature showed modest changes (range = -0.15 to 0.13 degrees C) and never exceeded 37.2 degrees C. Thermoregulation was principally controlled by appropriate increases in evaporative heat loss (sweating) and, to a lesser extent, by changes in skin blood flow. Because of the deep penetration of RF energy at this frequency, effectively bypassing the skin, these changes must have been stimulated by thermal receptors deep in the body rather than those located in the skin.  相似文献   

2.
Because exposure to microwave fields at the resonant frequency may generate heat deep in the body, hyperthermia may result. This problem has been examined in an animal model to determine both the thresholds for response change and the steady-state thermoregulatory compensation for body heating during exposure at resonant (450 MHz) and supra-resonant (2,450 MHz) frequencies. Adult male squirrel monkeys, held in the far field of an antenna within an anechoic chamber, were exposed (10 min or 90 min) to either 450-MHz or 2,450-MHz CW fields (E polarization) in cool environments. Whole-body SARs ranged from 0-6 W/kg (450 MHz) and 0-9 W/kg (2,450 MHz). Colonic and several skin temperatures, metabolic heat production, and evaporative heat loss were monitored continuously. During brief RF exposures in the cold, the reduction of metabolic heat production was directly proportional to the SAR, but 2,450-MHz energy was a more efficient stimulus than was the resonant frequency. In the steady state, a regulated increase in deep body temperature accompanied exposure at resonance, not unlike that which occurs during exercise. Detailed analyses of the data indicate that temperature changes in the skin are the primary source of the neural signal for a change in physiological interaction processes during RF exposure in the cold.  相似文献   

3.
Permission was received from the Brooks AFB Institutional Review Board and the AF Surgeon General's Office to exceed the peak power density (PD = 35 mW/cm(2)) we had previously studied during partial body exposure of human volunteers at 2450 MHz. Two additional peak PD were tested (50 and 70 mW/cm(2)). The higher of these PD (normalized peak local SAR = 15.4 W/kg) is well outside the IEEE C95.1 guidelines for partial body exposure, as is the estimated whole body SAR approximately 1.0 W/kg. Seven volunteers (four males, three females) were tested at each PD in three ambient temperatures (T(a) = 24, 28, and 31 degrees C) under our standard protocol (30 min baseline, 45 min RF exposure, 10 min baseline). The thermophysiological data (esophageal and six skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow) were combined with comparable data at PD = 0, 27, and 35 mW/cm(2) from our 1999 study to generate response functions across PD. No change in esophageal temperature or metabolic heat production was recorded at any PD in any T(a). At PD = 70 mW/cm(2), skin temperature on the upper back (irradiated directly) increased 4.0 degrees C in T(a) = 24 degrees C, 2.6 degrees C in T(a) = 28 degrees C, and 1.8 degrees C in T(a) = 31 degrees C. These differences were primarily due to the increase in local sweat rate, which was greatest in T(a) = 31 degrees C. Also at PD = 70 mW/cm(2), local skin blood flow on the back increased 65% over baseline levels in T(a) = 31 degrees C, but only 40% in T(a) = 24 degrees C. Although T(a) becomes an important variable when RF exposure exceeds the C95.1 partial body exposure limits, vigorous heat loss responses of blood flow and sweating maintain thermal homeostasis efficiently. It is also clear that strong sensations of heat and thermal discomfort will motivate a timely retreat from a strong RF field, long before these physiological responses are exhausted. Published 2001 Wiley-Liss, Inc.  相似文献   

4.
Since 1994, our research has demonstrated how thermophysiological responses are mobilized in human volunteers exposed to three radio frequencies, 100, 450, and 2450 MHz. A significant gap in this frequency range is now filled by the present study, conducted at 220 MHz. Thermoregulatory responses of heat loss and heat production were measured in six adult volunteers (five males, one female, aged 24-63 years) during 45 min whole body dorsal exposures to 220 MHz radio frequency (RF) energy. Three power densities (PD = 9, 12, and 15 mW/cm(2) [1 mW/cm(2) = 10 W/m(2)], whole body average normalized specific absorption rate [SAR] = 0.045 [W/kg]/[mW/cm(2)] = 0.0045 [W/kg]/[W/m(2)]) were tested at each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C) plus T(a) controls (no RF). Measured responses included esophageal (T(esoph)) and seven skin temperatures (T(sk)), metabolic rate (M), local sweat rate, and local skin blood flow (SkBF). Derived measures included heart rate (HR), respiration rate, and total evaporative water loss (EWL). Finite difference-time domain (FDTD) modeling of a seated 70 kg human exposed to 220 MHz predicted six localized "hot spots" at which local temperatures were also measured. No changes in M occurred under any test condition, while T(esoph) showed small changes (< or =0.35 degrees C) but never exceeded 37.3 degrees C. As with similar exposures at 100 MHz, local T(sk) changed little and modest increases in SkBF were recorded. At 220 MHz, vigorous sweating occurred at PD = 12 and 15 mW/cm(2), with sweating levels higher than those observed for equivalent PD at 100 MHz. Predicted "hot spots" were confirmed by local temperature measurements. The FDTD model showed the local SAR in deep neural tissues that harbor temperature-sensitive neurons (e.g., brainstem, spinal cord) to be greater at 220 than at 100 MHz. Human exposure at both 220 and 100 MHz results in far less skin heating than occurs during exposure at 450 MHz. However, the exposed subjects thermoregulate efficiently because of increased heat loss responses, particularly sweating. It is clear that these responses are controlled by neural signals from thermosensors deep in the brainstem and spinal cord, rather than those in the skin.  相似文献   

5.
Six male New Zealand white rabbits were individually exposed to 600 MHz radiofrequency (RF) radiation for 90 min in a waveguide exposure system at an ambient temperature (Ta) of 20 or 30 degrees C. Immediately after exposure, the rabbit was removed from the exposure chamber and its colonic and ear skin temperatures were quickly measured. The whole-body specific absorption rate (SAR) required to increase colonic and ear skin temperature was determined. At a Ta of 20 degrees C the threshold SAR for elevating colonic and ear skin temperature was 0.64 and 0.26 W/kg, respectively. At a Ta of 30 degrees C the threshold SARs were slightly less than at 20 degrees C, with values of 0.26 W/kg for elevating colonic temperature and 0.19 W/kg for elevating ear skin temperature. The relationship between heat load and elevation in deep body temperature shown in this study at 600 MHz is similar to past studies which employed much higher frequencies of RF radiation (2450-2884 MHz). On the other hand, comparison of these data with studies on exercise-induced heat production and thermoregulation in the rabbit suggest that the relationship between heat gain and elevation in body temperature in exercise and from exposure to RF radiation may differ considerably. When combined with other studies, it was shown that the logarithm of the SAR required for a 1.0 degree C elevation in deep body temperature of the rabbit, rat, hamster, and mouse was inversely related to the logarithm of body mass. The results of this study are consistent with the conclusion that body mass strongly influences thermoregulatory sensitivity of the aforementioned laboratory mammals during exposure to RF radiation.  相似文献   

6.
Thermoregulatory responses of heat production and heat loss were measured in two different groups of seven adult volunteers (males and females) during 45‐min dorsal exposures of the whole body to 450 or 2450 MHz continuous‐wave radio frequency (RF) fields. At each frequency, two power densities (PD) were tested at each of three ambient temperatures (Ta = 24, 28, and 31 °C) plus Ta controls (no RF). The normalized peak surface specific absorption rate (SAR), measured at the location of the subject's center back, was the same for comparable PD at both frequencies, i.e., peak surface SAR = 6.0 and 7.7 W/kg. No change in metabolic heat production occurred under any exposure conditions at either frequency. The magnitude of increase in those skin temperatures under direct irradiation was directly related to frequency, but local sweating rates on back and chest were related more to Ta and SAR. Both efficient sweating and increased local skin blood flow contributed to the regulation of the deep body (esophageal) temperature to within 0.1 °C of the baseline level. At both frequencies, normalized peak SARs in excess of ANSI/IEEE C95.1 guidelines were easily counteracted by normal thermophysiological mechanisms. The observed frequency‐related response differences agree with classical data concerning the control of heat loss mechanisms in human beings. However, more practical dosimetry than is currently available will be necessary to evaluate realistic human exposures to RF energy in the natural environment. Bioelectromagnetics 20:12–20, 1999. Published 1999 Wiley‐Liss, Inc.  相似文献   

7.
In vitro experiments were performed to determine whether 2450 MHz microwave radiation induces alkali-labile DNA damage and/or DNA-protein or DNA-DNA crosslinks in C3H 10T(1/2) cells. After a 2-h exposure to either 2450 MHz continuous-wave (CW) microwaves at an SAR of 1.9 W/kg or 1 mM cisplatinum (CDDP, a positive control for DNA crosslinks), C3H 10T(1/2) cells were irradiated with 4 Gy of gamma rays ((137)Cs). Immediately after gamma irradiation, the single-cell gel electrophoresis assay was performed to detect DNA damage. For each exposure condition, one set of samples was treated with proteinase K (1 mg/ml) to remove any possible DNA-protein crosslinks. To measure DNA-protein crosslinks independent of DNA-DNA crosslinks, we quantified the proteins that were recovered with DNA after microwave exposure, using CDDP and gamma irradiation, positive controls for DNA-protein crosslinks. Ionizing radiation (4 Gy) induced significant DNA damage. However, no DNA damage could be detected after exposure to 2450 MHz CW microwaves alone. The crosslinking agent CDDP significantly reduced both the comet length and the normalized comet moment in C3H 10T(1/2) cells irradiated with 4 Gy gamma rays. In contrast, 2450 MHz microwaves did not impede the DNA migration induced by gamma rays. When control cells were treated with proteinase K, both parameters increased in the absence of any DNA damage. However, no additional effect of proteinase K was seen in samples exposed to 2450 MHz microwaves or in samples treated with the combination of microwaves and radiation. On the other hand, proteinase K treatment was ineffective in restoring any migration of the DNA in cells pretreated with CDDP and irradiated with gamma rays. When DNA-protein crosslinks were specifically measured, we found no evidence for the induction of DNA-protein crosslinks or changes in amount of the protein associated with DNA by 2450 MHz CW microwave exposure. Thus 2-h exposures to 1.9 W/ kg of 2450 MHz CW microwaves did not induce measurable alkali-labile DNA damage or DNA-DNA or DNA-protein crosslinks.  相似文献   

8.
Normal human lymphocytes were isolated from the peripheral blood of healthy donors. One-ml samples containing (10(6)) cells in chromosome medium 1A were exposed for 5 days to conventional heating or to continuous wave (CW) or pulsed wave (PW) 2450-MHz radiation at non-heating (37 degrees C) and various heating levels (temperature increases of 0.5, 1.0, 1.5, and 2 degrees C). The pulsed exposures involved 1-microsecond pulses at pulse repetition frequencies from 100 to 1,000 pulses per second at the same average SAR levels as the CW exposures. Actual average SARs ranged to 12.3 W/kg. Following termination of the incubation period, spontaneous lymphoblastoid transformation was determined with an image analysis system. The results were compared among each of the experimental conditions and with sham-exposed cultures. At non-heating levels, CW exposure did not affect transformation. At heating levels both conventional and CW heating enhanced transformation to the same extent and correlate with the increases in incubation temperature. PW exposure enhanced transformation at non-heating levels. This finding is significant (P less than .002). At heating levels PW exposure enhanced transformation to a greater extent than did conventional or CW heating. This finding is significant at the .02 level. We conclude that PW 2450-MHz radiation acts differently on the process of lymphoblastoid transformation in vitro compared with CW 2450-MHz radiation at the same average SARs.  相似文献   

9.
The effects of modafinil on heat thermoregulatory responses were studied in 10 male subjects submitted to a sweating test after taking 200 mg of modafinil or placebo. Sweating tests were performed in a hot climatic chamber (45 degrees C, relative humidity <15%, wind speed = 0.8 m x s(-1), duration 1.5 h). Body temperatures (rectal (Tre) and 10 skin temperatures (Tsk)), sweat rate, and metabolic heat production (M) were studied as well as heart rate (HR). Results showed that modafinil induced at the end of the sweating test higher body temperatures increases (0.50 +/- 0.04 versus 0.24 +/- 0.05 degrees C (P < 0.01) for deltaTre and 3.64 +/- 0.16 versus 3.32 +/- 0.16 degrees C (P < 0.05) for deltaTsk (mean skin temperature)) and a decrease in sweating rate throughout the heat exposure (P < 0.05) without change in M, leading to a higher body heat storage (P < 0.05). AHR was also increased, especially at the end of the sweating test (17.95 +/- 1.49 versus 12.52 +/- 1.24 beats/min (P < 0.01)). In conclusion, modafinil induced a slight hyperthermic effect during passive dry heat exposure related to a lower sweat rate, probably by its action on the central nervous system, and this could impair heat tolerance.  相似文献   

10.
A previous study showed a substantial increase in the colonic temperature of rhesus monkeys (Macaca mulatta) exposed to radiofrequency (RF) fields at a frequency near whole-body resonance and specific absorption rates (SAR) of 2-3 W/kg. The present experiments were conducted to determine the metabolic and vasomotor responses during exposures to similar RF fields. We exposed five adult male rhesus monkeys to 225 MHz radiation (E orientation) in an anechoic chamber. Oxygen consumption and carbon dioxide production were measured before, during, and after RF exposure. Colonic, tail and leg skin temperatures were continuously monitored with RF-nonperturbing probes. The monkeys were irradiated at two carefully-controlled ambient temperatures, either cool (20 degrees C) or thermoneutral (26 degrees C). Power densities ranged from 0 (sham) to 10.0 mW/cm2 with an average whole-body SAR of 0.285 (W/kg)/(mW/cm2). We used two experimental protocols, each of which began with a 120-min pre-exposure equilibration period. One protocol involved repetitive 10-min RF exposures at successively higher power densities with a recovery period between exposures. In the second protocol, a 120-min RF exposure permitted the measurement of steady-state thermoregulatory responses. Metabolic and vasomotor adjustments in the rhesus monkey exposed to 225 MHz occurred during brief or sustained exposures at SARs at or above 1.4 W/kg. The SAR required to produce a given response varied with ambient temperature. Metabolic and vasomotor responses were coordinated effectively to produce a stable deep body temperature. The results show that the thermoregulatory response of the rhesus monkey to an RF exposure at a resonant frequency limits storage of heat in the body. However, substantial increases in colonic temperature were not prevented by such responses, even in a cool environment.  相似文献   

11.
GSM phone signal does not produce subjective symptoms   总被引:8,自引:0,他引:8  
The influence of pulsed radiofrequency (RF) electromagnetic fields of digital GSM mobile phones (902 MHz, 217 Hz pulse modulation) on subjective symptoms or sensations in healthy subjects were studied in two single-blind experiments. The duration of the RF exposure was about 60 min in Experiment 1 and 30 min in Experiment 2. Each subject rated symptoms or sensations in the beginning of the experimental session and at the end of both the exposure and the nonexposure conditions. The symptoms rated were headache, dizziness, fatigue, itching or tingling of the skin, redness on the skin, and sensations of warmth on the skin. The results did not reveal any differences between exposure and non-exposure conditions, suggesting that a 30-60 min exposure to this RF field does not produce subjective symptoms in humans.  相似文献   

12.
The induction of stress proteins in HeLa and CHO cells was investigated following a 2 h exposure to radiofrequency (RF) or microwave radiation. Cells were exposed or sham exposed in vitro under isothermal (37 ± 0.2 °C) conditions. HeLa cells were exposed to 27- or 2450 MHz continuous wave (CW) radiation at a specific absorption rate (SAR) of 25 W/kg. CHO cells were exposed to CW 27 MHz radiation at a SAR of 100 W/kg. Parallel positive control studies included 2 h exposure of HeLa or CHO cells to 40 °C or to 45 μM cadmium sulfate. Stress protein induction was assayed 24 h after treatment by electrophoresis of whole-cell extracted protein labeled with [35S]-methionine. Both cell types exhibited well-characterized responses to the positive control stresses. Under these exposure conditions, neither microwave nor RF radiation had a detectable effect on stress protein induction as determined by either comparison of RF-exposed cells with sham-exposed cells or comparison with heat-stressed or Cd++ positive control cells. Bioelectromagnetics 18:499–505, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

13.
In this study, we investigated whether exposure to 2450 MHz high-frequency electromagnetic fields (HFEMFs) could act as an environmental insult to evoke a stress response in A172 cells, using HSP70 and HSP27 as stress markers. The cells were exposed to a 2450 MHz HFEMF with a wide range of specific absorption rates (SARs: 5-200 W/kg) or sham conditions. Because exposure to 2450 MHz HFEMF at 50-200 W/kg SAR causes temperature increases in culture medium, appropriate heat control groups (38-44 degrees C) were also included. The expression of HSP 70 and HSP 27, as well as the level of phosphorylated HSP 27 ((78)Ser) (p-HSP27), was determined by Western blotting. Our results showed that the expression of HSP 70 increased in a time and dose-dependent manner at >50 W/kg SAR for 1-3 h. A similar effect was also observed in corresponding heat controls. There was no significant change in HSP 27 expression caused by HFEMF at 5-200 W/kg or by comparable heating for 1-3 h. However, HSP 27 phosphorylation increased transiently at 100 and 200 W/kg to a greater extent than at 40-44 degrees C. Phosphorylation of HSP 27 reached a maximum after 1 h exposure at 100 W/kg HFEMF. Our results suggest that exposure to a 2450 MHz HFEMF has little or no apparent effect on HSP70 and HSP27 expression, but it may induce a transient increase in HSP27 Phosphorylation in A172 cells at very high SAR (>100 W/kg).  相似文献   

14.
It has been suggested that chronic, low-level exposure to radiofrequency (RF) radiation may promote the formation of tumors. Previous studies, however, showed that low-level, long-term exposure of mammary tumor-prone mice to 435 MHz or 2450 MHz RF radiation did not affect the incidence of mammary tumors. In this study, we investigated the effects of exposure to a unique type of electromagnetic energy: pulses composed of an ultra-wideband (UWB) of frequencies, including those in the RF range. One hundred C3H/HeJ mice were exposed to UWB pulses (rise time 176 ps, fall time 3.5 ns, pulse width 1.9 ns, peak E-field 40 kV/m, repetition rate 1 kHz). Each animal was exposed for 2 min once a week for 12 weeks. One hundred mice were used as sham controls. There were no significant differences between groups with respect to incidence of palpated mammary tumors, latency to tumor onset, rate of tumor growth, or animal survival. Histopathological evaluations revealed no significant differences between the two groups in numbers of neoplasms in all tissues studied (lymphoreticular tissue, thymus, respiratory, digestive and urinary tracts, reproductive, mammary and endocrine systems, and skin). Our major finding was the lack of effects of UWB-pulse exposure on promotion of mammary tumors in a well-established animal model of mammary cancer.  相似文献   

15.
Helix aspersa neurons were irradiated with continuous-wave (CW) and noise-amplitude-modulated microwaves (carrier frequency 2450 MHz, 20% AM, 2 Hz-20 kHz) in a specially designed waveguide exposure system. Continuous-wave microwave irradiations were conducted at 8 degrees, 21 degrees, and 28 degrees C, while noise-modulated irradiation was performed at 21 degrees C. The results showed that exposure of snail neurons to CW microwaves for 60 min at 12.9 W/kg inhibited spontaneous activity and reduced input resistance at 8 degrees and 21 degrees C but not at 28 degrees C. The relative decrease in resistance at 21 degrees C was half that at 8 degrees C. Exposure of neurons to noise-modulated microwaves at 6.8 and 14.4 W/kg predominately caused excitatory responses characterized by augmented membrane resistance and the appearance of greater activity. The effect differed qualitatively from the inhibition observed with continuous, unmodulated microwave irradiation.  相似文献   

16.
Thermoregulatory responses of heat production and heat loss were measured in seven adult volunteers (four women and three men, aged 21–57 yr) during 45-min dorsal exposures of the whole body to 450 MHz continuous wave radio frequency (RF) fields. Two power densities (PD) (local peak PD = 18 and 24 mW/cm2; local peak specific absorption rate = 0.320 [W/kg]/[mW/cm2]) were tested in each of three ambient temperatures (Ta = 24, 28, and 31 °C) plus Ta controls (no RF). No changes in metabolic heat production occurred under any exposure conditions. Vigorous increases in sweating rate on back and chest, directly related to both Ta and PD, cooled the skin and ensured efficient regulation of the deep body (esophageal) temperature to within 0.1 °C of the normal level. Category judgments of thermal sensation, comfort, sweating, and thermal preference usually matched the measured changes in physiological responses. Some subtle effects related to gender were noted that confirm classic physiological data. Our results indicate that dorsal exposures of humans to a supra-resonant frequency of 450 MHz at local peak specific absorption rates up to 7.68 W/kg are mildly thermogenic and are counteracted efficiently by normal thermophysiologic heat loss mechanisms, principally sweating. Bioelectromagnetics 19:232–245, 1998. Published 1998 Wiley-Liss, Inc.  相似文献   

17.
As of today, only acute effects of RF fields have been confirmed to represent a potential health hazard and they are attributed to non-specific heating (≥ 1 °C) under high-level exposure. Yet, the possibility that environmental RF impact living matter in the absence of temperature elevation needs further investigation. Since HSF1 is both a thermosensor and the master regulator of heat-shock stress response in eukaryotes, it remains to assess HSF1 activation in live cells under exposure to low-level RF signals. We thus measured basal, temperature-induced, and chemically induced HSF1 trimerization, a mandatory step on the cascade of HSF1 activation, under RF exposure to continuous wave (CW), Global System for Mobile (GSM), and Wi-Fi-modulated 1800 MHz signals, using a bioluminescence resonance energy transfer technique (BRET) probe. Our results show that, as expected, HSF1 is heat-activated by acute exposure of transiently transfected HEK293T cells to a CW RF field at a specific absorption rate of 24 W/kg for 30 min. However, we found no evidence of HSF1 activation under the same RF exposure condition when the cell culture medium temperature was fixed. We also found no experimental evidence that, at a fixed temperature, chronic RF exposure for 24 h at a SAR of 1.5 and 6 W/kg altered the potency or the maximal capability of the proteasome inhibitor MG132 to activate HSF1, whatever signal used. We only found that RF exposure to CW signals (1.5 and 6 W/kg) and GSM signals (1.5 W/kg) for 24 h marginally decreased basal HSF1 activity.Electronic supplementary materialThe online version of this article (10.1007/s12192-020-01172-3) contains supplementary material, which is available to authorized users.  相似文献   

18.
The effects of pulsed-(PW) and continuous-wave (CW) 2.8-GHz microwaves were compared on the performance of rodents maintained by a temporally defined schedule of positive reinforcement. The schedule involved food-pellet reinforcement of behavior according to a differential-reinforcement-of-low-rate (DRL) contingency. The rats were independently exposed to PW and to CW fields at power densities ranging from 1 to 15 mW/cm2. Alterations of normal performance were more pronounced after a 30-minute exposure to the PW field than to the CW field. The rate of emission of appropriately timed responses declined after exposure to PW at 10 and 15 mW/cm2, whereas exposure at the same power levels to the CW field did not consistently affect the rate of responding. Change in performance associated with microwave exposure was not necessarily related to a general decline in responding: in some instances, increases in overall rates of responding were observed.  相似文献   

19.
The spatial distributions of induced 27 or 2450 MHz radiofrequency (RF) electric fields (E-fields) and specific absorption rates (SARs) in a three-component spherical cell model (cytoplasm, membrane, extracellular space) were determined by Mie scattering theory. The results were compared to results for the same cell model but with 0.5 nm thick of bound water on the inner (cytoplasmic) and outer (extracellular) membrane surfaces (i.e., five-component cell model). The results provide insight regarding direct frequency-dependent RF radiation effects at the cellular level. Induced E-fields and SARs were calculated for two bound-water characteristic frequencies (400 or 1000 MHz) and ionic conductivities (1–1000 mS/m). In order to estimate the dependence of the results on bound water within the membrane per se, the model was revised to include bound water within the inner and outer membrane surfaces. The results were as follows: (1) On the x-axis, the y- and z-components of the induced E-field were of insignificant magnitude compared to the x-component for an incident E-field parallel to the x-axis; (2) the ratio of transmembrane E-fields induced by 2450 MHz vs. 27 MHz RF [i.e., Ex (2450 MHz)/Ex (27 MHz)] was 0.1; (3) for the three-component cell model, the corresponding SAR ratios [SAR (2450 MHz)/SAR (27 MHz)] in the cytoplasm and extracellular space were 1.66 and 5.0, respectively; (4) the SAR ratios [SAR (2450 MHz)/SAR (27 MHz)] for the cytoplasm and extracellular space for the five-component cell model were 1.66 and 5.0, respectively; (5) the ratio of the E-fields induced in the cytoplasmic and extracellular layers of bound water in the five-component cell model [E (2450 MHz)/E (27 MHz)] were 0.62 and 0.63, respectively; (6) the SAR ratios [SAR (2450 MHz)/SAR (27 MHz)] for the cytoplasmic and extracellular bound-water layers were 66 and 65.3, respectively; and (7) variation of bound-water characteristic frequency, ionic conductivity, or bound-water incorporation inside the membrane surfaces, per se, did not significantly affect the E-field or SAR ratios. These results indicate that frequency-dependent nonuniformities may occur in the distribution of induced RF E-fields and SARs at the cellular level. © 1995 Wiley-Liss, Inc.  相似文献   

20.
We have studied the non-thermal effects of radiofrequency (RF) electromagnetic fields (EMFs) on Ba(2+) currents (I Ba 2+) through voltage-gated calcium channels (VGCC), recorded in primary cultures of rat cortical neurons using the patch-clamp technique. To assess whether low-level acute RF field exposure could modify the amplitude and/or the voltage-dependence of I Ba 2+, Petri dishes containing cultured neurons were exposed for 1-3 periods of 90 s to 900 MHz RF-EMF continuous wave (CW) or amplitude-modulated according to global system mobile communication standard (GSM) during whole-cell recording. The specific absorption rates (SARs) were 2 W/kg for CW and 2 W/kg (time average value) for GSM-modulated signals, respectively. The results obtained indicate that single or multiple acute exposures to either CW or GSM-modulated 900 MHz RF-EMFs do not significantly alter the current amplitude or the current-voltage relationship of I Ba 2+, through VGCC.  相似文献   