首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study presents the implementation of a mathematical bone remodeling algorithm to bone adaptation in the premolar area of the mandible around various dental implant systems, and thus sheds a new perspective to the complex interactions in dental implant mechanics. A two-dimensional, plane strain model of the bone was built from a CT-scan. The effect of implant contour on internal bone remodeling was investigated by considering four dental implant systems with contours similar to commercially available ones and another four with cylindrical and conical cross-sections. The remodeling algorithm predicts non-homogeneous density/elastic modulus distribution; and, implant contour has some effect on how this is distributed. Bone density is predicted to increase on the tips of the threads of the implants, but to decrease inside the grooves. Threadless implants favor to develop a softer bone around their periphery, compared to implant systems that have threads. The overall contour (dimensions and the shape) of an implant affect the bone density redistribution, but the differences between different implant systems are relatively small.  相似文献   

2.
The objective of this study was to see whether a mathematical model of fracture healing was able to mimic bone formation around an unloaded screw-shaped titanium implant as it is well-believed that both processes exhibit many biological similarities. This model describes the spatio-temporal evolution of cellular activities, ranging from mesenchymal stem cell migration, proliferation, differentiation to bone formation, which are initiated and regulated by the growth factors present at the peri-implant site. For the simulations, a finite volume code was used and adequate initial and boundary conditions were applied. Two sets of analyses have been performed, in which either initial and boundary condition or model parameter values were changed with respect to the fracture healing model parameter values. For a number of combinations, the spatio-temporal evolution of bone density was well-predicted. However reducing cell proliferation rate and increasing osteoblast differentiation and osteogenic growth factor synthesis rates, the simulation results were in agreement with the experimental data.  相似文献   

3.
Biomechanics and Modeling in Mechanobiology - Peri-prosthetic bone adaptation has usually been predicted using subject-specific finite element analysis in combination with remodelling algorithms...  相似文献   

4.
It is becoming apparent that anti-cancer chemotherapies are increasingly associated with cardiac dysfunction or even congestive heart failure (Minotti et al., 2004; Eliott, 2006; Suter et al., 2004; Ren, 2005). Our data suggest that one of the contributing factors to the cardiotoxicitiy of these drugs may be the activation of the AhR-response (including the increased expression of Cyp1a1) and/or other detoxification program in cardiac myocytes themselves. The induction of such responses may have secondary effects (e.g. to increase the level of intracellular oxidative stress), which may influence the contractility or even survival of cardiac myocytes. Furthermore, the specific response of cardiac myocytes, both with respect to the metabolizing enzymes and the export channels, potentially differs from other cells (e.g. we failed to detect any increase in expression of other “classical” AhR-responsive genes, Ugt1a1 and Ugt1a6). This could account for, for example, the observation that doxoribicinol (the 13-hydroxy form of doxorubicin) accumulates in cardiac myocytes but not in hepatocytes (Del Tacca et al., 1985; Olson et al., 1988). Given the vulnerability of the heart and the almost irreparable damage that can be done by severe oxidative stress, further studies would seem to be merited specifically on the effects of chemotherapeutic agents on cardiac myocytes.  相似文献   

5.
Resurfacing of the femur has experienced a revival, particularly in younger and more active patients. The implant is generally cemented onto the reamed trabecular bone and theoretical remodelling for this configuration, as well as uncemented variations, has been studied with relation to component positioning for the most common designs. The purpose of this study was to investigate the influence of different interface conditions, for alternative interior implant geometries, on bone strains in comparison to the native femur, and its consequent remodelling. A cylindrical interior geometry, two conical geometries and a spherical cortex-preserving design were compared with a standard implant (ASR, DePuy International, Ltd., UK), which has a 3° cone. Cemented as well as uncemented line to line and press-fit conditions were modelled for each geometry. A patient-specific finite element model of the proximal femur was used with simulated walking loads. Strain energy density was compared between the reference and resurfaced femur, and input into a remodelling algorithm to predict density changes post-operatively. The common cemented designs (cylindrical, slightly conical) had strain shielding in the superior femoral head (>35% reduction) as well as strain concentrations (strain>5%) in the neck regions near the implant rim. The cortex-preserving (spherical) and strongly conical designs showed less strain shielding. In contrast to the cemented implants, line to line implants showed a density decrease at the centre of the femoral head, while all press-fit versions showed a density increase (>100%) relative to the native femur, which suggests that uncemented press-fit implants could limit bone resorption.  相似文献   

6.
Hip resurfacing arthroplasty is an alternative to traditional hip replacement that can conserve proximal bone stock and has gained popularity but bone resorption may limit implant survival and remains a clinical concern. The goal of this study was to analyze bone remodelling patterns around an uncemented resurfacing implant and the influence of ingrowth regions on resorption. A computed tomography-derived finite element model of a proximal femur with a virtually implanted resurfacing component was simulated under peak walking loads. Bone ingrowth was simulated by six interface conditions: fully bonded; fully friction; bonded cap with friction stem; a small bonded region at the stem-cup intersection with the remaining surface friction; fully frictional, except for a bonded band along the distal end of the cap and superior half of the cap bonded with the rest frictional. Interface condition had a large influence on remodelling patterns. Bone resorption was minimized when no ingrowth occurred at the bone-implant interface. Bonding only the superior half of the cap increased bone resorption slightly but allowed for a large ingrowth region to improve secondary stability.  相似文献   

7.
Bone cells derived from the human jaw were cultured on titanium, titanium coated with hydroxyapatite (THA) or with plasma spray (TPS) to study the behaviour of the cells anchored to implant substrates. Bone cells were cultured in MEM with the addition of [3H]-thymidine to evaluate cellular proliferation, and [3H]-glucosamine to evaluate GAG synthesis and accumulation in the extra-cellular matrix (ECM). Moreover, to study the degradation of GAG bone cells were cultured in the presence of NH4Cl, an amine known to inhibit lysosomal activity. Our results show that TPS is the substrate that favours both cellular proliferation and the accumulation of GAG in the ECM. © 1997 John Wiley & Sons, Ltd.  相似文献   

8.
This study aimed to improve understanding of the mechanical aspects of cemented implant loosening. After aggressive fatigue loading of stem/cement/femur constructs, micro-cracks and stem/bone micro-motions were quantified to answer three research questions: Are cracks preferentially associated with the stem/cement interface, the cement/bone interface or voids? Is cement damage dependent on axial position? Does cement damage correlate with micro-motion between the stem and the bone? Eight Charnley Cobra stems were implanted in cadaveric femora. Six stem/cement/femur constructs were subjected to "stair-climbing" loads for 300 kcycles at 2Hz. Loads were normalized by construct stiffness to avoid fracture. Two additional constructs were not loaded. Transverse sections were cut at 10mm intervals, stained with a fluorescent dye penetrant and examined using epi-fluorescence stereomicroscopy. Crack lengths and cement areas were recorded for 9 sections per specimen. Crack length-density was calculated by dividing summed crack length by cement mantle area. To isolate the effect of loading, length-density data were offset by the baseline length-density measured in the non-loaded specimens. Significantly more cracks were associated with the interdigitated area (35.1%+/-11.6%) and the cement/bone interface (31.0%+/-6.2%) than with the stem/cement interface (11.0%+/-5.2%) or voids (6.1%+/-4.8%) (p<0.05). Load-induced micro-crack length-density was significantly dependent on axial position, increasing proximally (p<0.001). Micro-motions were small, all stems rotated internally. Cement damage did not correlate with micro-motion.  相似文献   

9.
10.
11.
Abstract

Objectives: The purpose of the present study was to evaluate the distribution and magnitude of stresses through the bone tissue surrounding Morse taper dental implants at different positioning relative to the bone crest. Materials and Methods: A mandibular bone model was obtained from a computed tomography scan. A three-dimensional (3D) model of Morse taper implant-abutment systems placed at the bone crest (equicrestal) and 2?mm bellow the bone crest (subcrestal) were assessed by finite element analysis (FEA). FEA was carried out on axial and oblique (45°) loading at 150 N relatively to the central axis of the implant. The von Mises stresses were analysed considering magnitude and volume of affected peri-implant bone. Results: On vertical loading, maximum von Mises stresses were recorded at 6-7?MPa for trabecular bone while values ranging from 73 up to 118?MPa were recorded for cortical bone. On oblique loading at the equiquestral or subcrestal positioning, the maximum von Mises stresses ranged from 15 to 21?MPa for trabecular bone while values at 150?MPa were recorded for the cortical bone. On vertical loading, >99.9vol.% cortical bone volume was subjected to a maximum of 2?MPa while von Mises stress values at 15?MPa were recorded for trabecular bone. On oblique loading, >99.9vol.% trabecular bone volume was subjected to maximum stress values at 5?MPa, while von Mises stress values at 35?MPa were recorded for >99.4vol.% cortical bone. Conclusions: Bone volume-based stress analysis revealed that most of the bone volume (>99% by vol) was subjected to significantly lower stress values around Morse taper implants placed at equicrestal or subcrestal positioning. Such analysis is commentary to the ordinary biomechanical assessment of dental implants concerning the stress distribution through peri-implant sites.  相似文献   

12.
Bone formation and growth are controlled by genetic, hormonal and biomechanical factors. In this study, an established rat disuse osteoporosis model, hindlimb-suspension (HLS), was used to relate morphological change and gene expression to altered mechanical load in the underloaded femora and the ostensibly normally loaded humeri of the suspended rats (39 days old at onset; 1, 3, 7 and 14 days suspension). Morphological change was measured by labelling new bone formation with fluorescent agents during the experimental period and subsequent histological analysis of bone sections post-sacrifice. Hindlimb suspension reduced both the total amount of bone present, assessed as cross-sectional area, and the bone formation rate at the mid-diaphysis of the unloaded femora while no significant effect was found in the loaded humeri. In addition, the femora of the suspended animals were found to have a markedly increased circularity as a result of unloading. A sensitive semi-quantitative method of gene expression analysis, involving the creation of SMART cDNA arrays, was successfully implemented. This technique amplified all populations of mRNA to levels where they could be assessed using standard molecular biology protocols. Gene expression patterns of two candidate genes, c-fos and osteocalcin were assessed in periosteal tissue. Altered gene expression patterns were identified and tracked over the suspension period. The altered levels of both candidate genes were found to be consistent with the changes observed in the histological analysis.  相似文献   

13.

Background  

Aberrant reprogramming of donor somatic cell nuclei may result in many severe problems in animal cloning. To assess the extent of abnormal epigenetic modifications and gene expression in clones, we simultaneously examined DNA methylation, histone H4 acetylation and expression of six genes (β-actin, VEGF, oct4, TERT, H19 and Igf2) and a repetitive sequence (art2) in five organs (heart, liver, spleen, lung and kidney) from two cloned cattle groups that had died at different stages. In the ED group (early death, n = 3), the cloned cattle died in the perinatal period. The cattle in the LD group (late death, n = 3) died after the perinatal period. Normally reproduced cattle served as a control group (n = 3).  相似文献   

14.
Neuropeptide Y (NPY) is considered the major stimulant for food intake in mammals and fish. Previous results indicate that NPY is involved in the feeding behaviour of the Brazilian flounder, Paralichthys orbignyanus. In this study, we evaluated hypothalamic NPY expression before (-2 h), during (0 h) and after feeding (+2 h) in two independent experiments: (1) during a normal feeding schedule and (2) in fish fasted for 2 weeks. During normal feeding, changes in the levels of NPY mRNA were periprandial, with expression levels being significantly elevated at meal time (P less than 0.05) and significantly reduced 2 h later (P less than 0.05). Comparing the fasting and unfasted groups, NPY mRNA levels were significantly higher (P less than 0.05) at -2 h and +2 h in the fasting group, but there was no difference at 0 h. In addition, the higher NPY mRNA levels that were observed in the fasting group were maintained throughout the sampling period. In summary, our results show that NPY expression was associated with meal time (0 h) in food intake regulation.  相似文献   

15.
16.
17.
18.
19.
20.
For biochemical modification of the root-soil interface, the engineered secretion of stable enzymes from trichoblasts (= root hair bearing rhizodermal cells) is proposed. As a reporter activity, we chose to express a synthetic gene encoding a secretory phytase (PHY) directed by a trichoblast-specific promoter in root hair cells of the crop plant potato. Transgenic plants produced and secreted phytase in sufficient amounts to release phosphate from phytate in liquid medium. When grown in an unsterile substrate containing phytate, transgenic plants accumulated 40% more P in leaves than wild-type plants. The improved P nutrition driven by trichoblast-targeted expression and subsequent secretion of PHY illustrates the potential of using trichoblast-targeted expression of suitable enzymes for future applications in plant nutrition, phytoremediation and molecular farming.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号