1.
The purpose of this study was to evaluate gender and muscle differences in electromyographic (EMG) amplitude and median frequency mean and standard deviation during maximal voluntary contractions of the quadriceps femoris. Thirty recreationally active volunteers were assessed for isometric EMG activity of the vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF) muscles during three 5-s maximal isometric voluntary contractions (MVCs). Median frequency of the three muscles was assessed through a power spectral analysis (fast Fourier transformation, Hanning window processing, 512 points). The power spectral analysis was performed during the middle 3 s of each contraction over 11 consecutive, 512 ms epochs overlapping each other by half their length (256 ms). The median frequency (F(med)) for each of the 11 windows was determined for each muscle. The mean and standard deviation of the F(med) across the 11 overlapping windows were then calculated for each contraction and muscle. EMG amplitude was determined by calculating the root mean square (RMS-50 ms time constant) over the same contraction period for each muscle. The mean amplitude and standard deviation about the mean value were then determined. A three-factor ANOVA with repeated measures was performed on the calculated F(med) mean and standard deviation values, and RMS standard deviations, to assess any gender, muscle, or trial differences, or interactions. A two-factor (gender by muscle) ANOVA with repeated measures was performed on the RMS mean amplitude for each muscle. Intraclass correlation coefficients (ICCs-2,1), standard errors of measurement (SEMs), and associated 95% confidence intervals were then calculated for maximal quadriceps torque and F(med) for each muscle. The results from this study demonstrated that the VL muscle displayed significantly higher F(med) values than the RF and VM muscles. The RF muscle showed significantly higher F(med) values (mean of 11 overlapping windows) than the VM muscle. Intrasession reliability was found to be high for the calculated mean values (ICC=0.85-0.96), but was shown to be low for variability (ICC=0.13-0.45). The major findings of this study support the notion that the EMG signal is "quasi-random" in nature, as demonstrated by the reproducible F(med) means and unreliable variability.  相似文献   

2.
There is a lack of information concerning the prevalence of Toxoplasma gondii infection in dogs from southwestern China. In the present study, serum samples from 314 household dogs were collected from Wenchuan, Heishui, and Jiuzhaigou in Sichuan Province, southwestern China, in May and June 201; sera were assayed for T. gondii antibodies using an indirect haemagglutination test (IHA). Antibodies to T. gondii were found in 11 of 314 (3.5%), with IHA titers of 1:64 in 4 dogs, 1:128 in 3, 1:256 in 2, 1:512 in 1, and 1:1024 in 1. No regional difference was observed among the 3 counties (P > 0.05). The results of the present study indicated that infection with T. gondii in dogs is common in China, including household dogs in Sichuan Province, and should be of public health concern.  相似文献   

3.
The goal of the present study was to compare electromyogram (EMG) power spectra obtained from step (constant force level) and ramp (progressive increase in the force level) isometric contractions. Data windows of different durations were also analysed for the step contractions, in order to evaluate the stability of EMG power spectrum statistics. Fourteen normal subjects performed (1) five ramp elbow extensions ranging from 0 to 100% of the maximum voluntary contraction (MVC) and (2) three stepwise elbow extensions maintained at five different levels of MVC. Spectral analysis of surface EMG signals obtained from triceps brachii and anconeus was performed. The mean power frequency (MPF) and the median frequency (MF) of each power spectrum were obtained from 256-ms windows taken at 10, 20, 40, 60 and 80% MVC for each type of contraction and in addition on 512-, 1024- and 2048-ms windows for the step contractions. No significant differences (P greater than 0.05) were found in the values of both spectral statistics between the different window lengths. Even though no significant differences (P greater than 0.05) were found between the ramp and the step contractions, significant interactions (P less than 0.05) between these two types of contraction and the force level were found for both the MPF and the MF data. These interactions point out the existence of different behaviours for both the MPF and the MF across force levels between the two types of contraction.  相似文献   

4.
Significance of skin temperature changes in surface electromyography.   总被引:4,自引:0,他引:4  
Differing results have been reported concerning the direction and quantity of the electromyogram (EMG) amplitude response to changes in tissue temperature. The EMG signals from the soleus muscle of six healthy human subjects were therefore recorded during dynamic exercise (concentric contractions) at ambient temperatures of 30 degrees C and 14 degrees C. The mean skin temperature (Tsk) above the muscle investigated was 32.9 degrees C and 21.7 degrees C, respectively. The core temperature, estimated by rectal temperature, was unchanged. The cooling of the superficial tissues caused approximately a doubling of the EMG amplitude. For the probability level 0.9 in the amplitude probability distribution function, the average signal level increased from 73 microV to 135 microV (P = 0.02). The average mean power frequency of the EMG signal was reduced from 142 Hz to 83 Hz (P = 0.004). The amplitude increase was not due to shivering but other possible explanations are presented. As the changes in Tsk investigated were within the range which may occur normally during the working hours, it was concluded that Tsk should be carefully controlled in vocational EMG studies.  相似文献   

5.
The aim of the study was to investigate amplitude and frequency content of single motor unit (MU) electromyographic (EMG) and mechanomyographic (MMG) responses. Multi-channel surface EMG and MMG signals were detected from the dominant biceps brachii muscle of 10 volunteers during isometric voluntary contractions at 20%, 50%, and 80% of the maximal voluntary contraction (MVC) force. Each contraction was performed three times in the experimental session which was repeated in three non-consecutive days. Single MU action potentials were identified from the surface EMG signals and their times of occurrence used to trigger the averaging of the MMG signal. At each contraction level, the MUs with action potentials of highest amplitude were identified. Single MU EMG and MMG amplitude and mean frequency were estimated with normalized standard error of the mean within subjects (due to repetition of the measure in different trials and experimental sessions) smaller than 15% and 7%, respectively, in all conditions. The amplitude of the action potentials of the detected MUs increased with increasing force (mean +/- SD, 244 +/- 116 microV at 20% MVC, and 1426 +/- 638 microV at 80% MVC; P < 0.001) while MU MMG amplitude increased from 20% to 50% MVC (40.5 +/- 20.9 and 150 +/- 88.4 mm/s(2), respectively; P<0.001) and did not change significantly between 50% and 80% MVC (129 +/ -82.7 mm/s(2) at 80% MVC). MU EMG mean frequency decreased with contraction level (20% MVC: 97.2 +/- 13.9 Hz; 80% MVC: 86.2 +/- 11.4 Hz; P < 0.001) while MU MMG mean frequency increased (20% MVC: 33.2 +/- 6.8 Hz; 80% MVC: 40.1 +/- 6.1 Hz; P < 0.001). EMG peak-to-peak amplitude and mean frequency of individual MUs were not correlated with the corresponding variables of MMG at any contraction level.  相似文献   

6.
A serological survey of Toxoplasma gondii infection among slaughtered pigs in the largest slaughterhouse located in Taoyuan County of northwestern Taiwan was conducted using the latex agglutination (LA) test during 1998. The overall seroprevalence of T. gondii infection was 28.8% (32/111) with LA titers of 1:32 (6, 18.8%), 1:64 (10, 31.2%), 1:128 (9, 28.1%), 1:256 (6, 18.8%), and 1:512 (1, 3.1%). No significant difference (P > 0.05) in seroprevalence between male (28.6%, 20/70) and female (29.7%, 12/41) slaughtered pigs was observed. A decreasing trend in the seroprevalence among slaughtered pigs examined in the same slaughterhouse was observed because of a lower seroprevalence (P < 0.05) than that (44.4%, 128/288) previously reported about 10 yr ago using the LA test. Nevertheless, it is important to avoid eating raw or undercooked pork in order to prevent the acquisition of T. gondii infection among people in Taiwan.  相似文献   

7.
The aim of this study was to assess the effect on EMG amplitude measures of variations in the thickness of underlying tissue between surface electrodes and the active muscle. 20 normal subjects with different amounts of subcutaneous tissue performed comparable constant force contractions for a 45-second period, during which paraspinal EMG recordings were taken. Three measures of subcutaneous tissue thickness were obtained from each subject: Body Mass Index, total body fat as calculated by Durnin's formula, and skinfold thickness at the recording sites. The results show that (i) the greater the thickness of subcutaneous tissue between the surface recording site and the contracting muscles, the lower the recorded electromyographic activity, and that (ii) up to 81.2% of the variance in the EMG measures can be explained by variation in the amount of subcutaneous tissue. These findings support the view that the absolute level of surface-recorded EMG cannot simply be taken at face value. The amplitude of the signal will be affected by, for example, the amount of body fat.Supported by the Physician's Services Inc. Foundation.  相似文献   

8.
The antimicrobial activity of the dichloromethane extract from aerial parts of Leuzea carthamoides DC. was tested in vitro against 19 Staphylococcus aureus strains (ATCC 25923, CNCTC Mau 43/60, clinical isolates). The extract was fractionated by column chromatography on silica gel into six fractions (petroleum ether, toluene, dichloromethane, ethyl acetate, methanol and water). The minimum inhibitory concentrations (MICs) of the fractions ranged from 64 to 1024 μg/mL. An ethyl acetate fraction (EA 1) with the widest range of activity inhibited all of the strains with MIC in the range 128–512 μg/mL. This fraction exhibited potent activity against strains which showed associated resistance to oxacillin, ciprofloxacin and erythromycin.  相似文献   

9.
目的 探讨土槿乙酸(pseudolaric acid B,PAB)对体外白假丝酵母菌生物膜的影响。方法 甲基四氮盐(XTT)法检测不同浓度PAB和AMB(两性霉素B)对白假丝酵母菌生物膜的抑制作用。血清芽管试验检测不同浓度PAB对芽管生成的影响。结果 PAB对白假丝酵母菌生物膜的SMIC50(抑制生物膜50%的药物浓度)为256~512 μg/mL;1024和512 μg/mL PAB对早期2 h生物膜的抑制率分别为(99.5±0.28)%和(97.1±0.38)%;512 μg/mL PAB对早期(2 h)、中期(8 h)及成熟期(24 h)生物膜的抑制率分别为(97.1±0.38)%、(90.4±0.32)%和(80.1±0.67)%;不同浓度PAB的血清芽管试验显示,64 μg/mL PAB可以完全抑制白假丝酵母菌的出芽生长,16 μg/mL PAB可以抑制83.5%的白假丝酵母菌出芽生长。结论 PAB对体外白假丝酵母菌生物膜有抑制作用,对白假丝酵母菌的出芽生长过程抑制作用显著。  相似文献   

10.
BACKGROUND: S-phase fraction (SPF) measurement by flow cytometry is a clinically useful prognostic factor in patients with breast carcinoma. Standardized SPF determination is essential. As part of a multicenter study, we evaluated the influence of the choice of software and histogram resolution (256, 512, or 1,024 channels) on SPF quantification. METHODS: One hundred thirty-three DNA histograms were analyzed in three laboratories with Modfit 5.2, Modfit LT, and Multicycle AV software. Strict rules for histogram interpretation and software management were applied. The following five options were compared: MF 5.2 1024, MF 5.2 256, MF LT 256, MC AV 256, and MC AV 512. RESULTS: In the DNA diploid and aneuploid groups, SPF distributions were not statistically different among the five options. Excellent quantitative correlations were obtained between pairs of options. When using tertiles as cutpoints for SPF classification, concordance rates ranged from 79.7% to 93.2% for DNA diploid samples and from 87.8% to 95.9% for DNA aneuploid samples, the best results being obtained with software working with a similar histogram resolution. CONCLUSIONS: Standardized use of commercially available software, including the choice of histogram resolution, provides comparable SPF results.  相似文献   

11.
The purpose of this study was to examine the effects of interelectrode distance (IED) on the absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) versus isokinetic and isometric torque relationships for the biceps brachii muscle. Ten adults [mean+/-SD age=22.0+/-3.4 years] performed submaximal to maximal, isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects performed randomly ordered, submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Surface EMG signals were recorded simultaneously from bipolar electrode arrangements placed over the biceps brachii muscle with IEDs of 20, 40, and 60mm. Absolute and normalized EMG amplitude (muVrms and %max) increased linearly with torque during the isokinetic and isometric muscle actions (r(2) range=0.988-0.998), but there were no significant changes for absolute or normalized EMG MPF (Hz or %max) from 10% to 100% PT and MVC. In some cases, there were significant (p<0.05) differences among the three IED arrangements for absolute EMG amplitude and MPF values, but not for the normalized values. These findings suggested that for the biceps brachii muscle, IEDs between 20 and 60mm resulted in similar patterns for the EMG amplitude or MPF versus dynamic and isometric torque relationships. Furthermore, unlike the absolute EMG amplitude and MPF values, the normalized EMG data were not influenced by changes in IED between 20 and 60mm. Thus, normalized EMG data can be compared among previous studies that have utilized different IED arrangements.  相似文献   

12.
The purpose of this study was to determine test-retest reliability for median frequency (MDF) and amplitude of surface EMG during sustained fatiguing contractions of the quadriceps. Twenty-two healthy subjects (11 males and 11 females) were tested on two days held one week apart. Surface EMG was recorded from rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) during sustained isometric contractions at 80% and 20% of maximal voluntary contraction (MVC) held to exhaustion. Quadriceps fatigue was described using four measures for both MDF and amplitude of EMG: initial, final, normalized final and slope. For both MDF and amplitude, the initial, final and normalized EMG showed moderate to high reliability for all three muscle groups at both contraction levels (ICC=0.59-0.88 for MDF; ICC=0.58-0.99 for amplitude). Slope of MDF and amplitude was associated with a large degree of variability and low ICCs for the 80% but not the 20% MVC. MDF and amplitude of EMG during sustained contractions of the quadriceps are reproducible; normalized final values of MDF and amplitude show better reliability than slope.  相似文献   

13.
A preliminary clinical trial using state‐of‐the‐art multiphoton tomography (MPT) and optical coherence tomography (OCT) for three‐dimensional (3D) multimodal in vivo imaging of normal skin, nevi, scars and pathologic skin lesions has been conducted. MPT enabled visualization of sub‐cellular details with axial and transverse resolutions of <2 μm and <0.5 μm, respectively, from a volume of 0.35 × 0.35 × 0.2 mm3 at a frame rate of 0.14 Hz (512 × 512 pixels). State‐of‐the‐art OCT, operating at a center wavelength of 1300 nm, was capable of acquiring 3D images depicting the layered architecture of skin with axial and transverse resolutions ~8 μm and ~20 μm, respectively, from a volume of 7 × 3.5 × 1.5 mm3 at a frame rate of 46 Hz (1024 × 1024 pixels). This study demonstrates the clinical diagnostic potential of MPT/OCT for pre‐screening relatively large areas of skin using 3D OCT to identify suspicious regions at microscopic level and subsequently using high resolution MPT to obtain zoomed in, sub‐cellular level information of the respective regions (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

14.
Trunk electromyographic signals (EMG) are often contaminated with heart muscle electrical activity (ECG) due to the proximity of the collection sites to the heart and the volume conduction characteristics of the ECG through the torso. Few studies have quantified ECG removal techniques relative to an uncontaminated EMG signal (gold standard or criterion measure), or made direct comparisons between different methods for a given set of data. Understanding the impacts of both untreated contaminated EMG and ECG elimination techniques on the amplitude and frequency parameters is vital given the widespread use of EMG. The purpose of this study was to evaluate four groups of current and commonly used techniques for the removal of ECG contamination from EMG signals. ECG recordings at two intensity levels (rest and 50% maximum predicted heart rate) were superimposed on 11 uncontaminated biceps brachii EMG signals (rest, 7 isometric and 3 isoinertial levels). The 23 removal methods used were high pass digital filtering (finite impulse response (FIR) using a Hamming window, and fourth-order Butterworth (BW) filter) at five cutoff frequencies (20, 30, 40, 50, and 60 Hz), template techniques (template subtraction and an amplitude gating template), combinations of the subtraction template and high pass digital filtering, and a frequency subtraction/signal reconstruction method. For muscle activation levels between 10% and 25% of maximum voluntary contraction, the template subtraction and BW filter with a 30 Hz cutoff were the two best methods for maximal ECG removal with minimal EMG distortion. The BW filter with a 30 Hz cutoff provided the optimal balance between ease of implementation, time investment, and performance across all contractions and heart rate levels for the EMG levels evaluated in this study.  相似文献   

15.
Two double-blind studies were performed to examine magnetic field (MF) exposure effects and to determine the impact of temporal variation (continuous vs. intermittent exposure) of 100 mu T(rms) 50 Hz MF diurnal exposure on psychological and psychophysiological parameters in healthy humans. Three cephalic exposure sessions of 30-min, i.e., sham, continuous, and intermittent (15 s ON/OFF cycles) MF conditions, were involved. Each subject participated in all sessions, which were spaced at 1-wk intervals. In each session, mood ratings and performance measures were obtained before, during, or after exposure and several electrophysiological data (event-related brain potentials [ERP]) were recorded after each exposure session. These criteria were chosen to evaluate sensory functions as well as automatic and voluntary attentional processes. In experiment 1, 21 healthy male volunteers (20 to 27 years of age) were studied. Ten subjects were exposed at 13:30 h, and 11 subjects were exposed at 16:30 h. Statistically significant changes in the amplitude of ERP were observed after MF exposure in the dichotic listening task, indexing selective attention processes. Eighteen of the 21 original male volunteers took part in experiment 2, undertaken to better understand the results related to information processing involved in selective attention and control for ultradian rhythmicity. Exposure time for all the subjects was at 13:30 h. The analysis of the data again revealed significant amplitude changes of the ERP recorded in the dichotic listening task. Moreover, they demonstrated ERP latency and reaction time slowing in the oddball paradigm, a visual discrimination task after real MF exposure. These results also indicate that a low level 50 Hz MF may have a slight influence on event-related potentials and reaction time under specific circumstances of sustained attention.  相似文献   

16.
Surface electromyography and turn–amplitude analysis were used to study muscle fatigue after exposure to heating (40°C, 60 min) and under thermoneutral conditions (22°C) in 12 parkinsonian patients from 57 to 65 years of age treated with Nacom, Bromocryptin, and Cyclodol. In the patients, heating caused a twofold increase in the motor performance (number of contractions until exhaustion and nerve conduction velocity) and a decrease in the mean electromyogram (EMG) amplitude and number of turns of spontaneous muscle activity. The spontaneous EMG activity was fully inhibited after exposure to heating and fatigue, suggesting a thermoregulatory dependence of the spontaneous muscle tone (rigidity) in parkinsonian patients. After exposure to heating, fatigue also caused a decrease in the peak ratio with a shift of the mean EMG amplitude to lower values. After-load recovery of the mean EMG amplitude was slower under heating versus thermoneutral conditions and was compensated for by an increased number of turns.  相似文献   

17.
This study sought to characterize muscle loading and fatigue during static shoulder abductions with varying force. In a supine posture, participants maintained fixed shoulder abductions against a time-varying external resistance, generated by a dynamometer-spring mechanism. Patterns (cumulative distribution) of the external resistance were varied by selecting different 10th and 90th percentiles of the distribution. Dynamometer angular velocities were also varied, to reflect different rates of cyclic muscle contraction. The degree of local fatigue development was assessed by common measures, including endurance time, strength reduction, and perceived discomfort. Myoelectric (EMG) signals were continuously obtained from the middle deltoid muscle throughout experimental exercise (60min max). Changes in EMG root-mean-square (RMS) and spectral measures (derived from 1-s windows at peaks in the cyclic contractions) were used as manifestations of muscle fatigue. For each minute, the RMS signal was further reduced using two methods, the cumulative probability distribution of EMG (CPDE) and exposure variation analysis (EVA). The former resulted in three percentile values (10th, 50th, and 90th), whereas the latter method resulted in 10 different measures (grouped by EMG activity level and duration). A main finding of the study was the applicability of several common fatigue indicators for these cyclic, repetitive exertions. Overall, the use of CPDE and EVA to characterize task differences and predict muscle fatigue was found to have limited value.  相似文献   

18.
Twelve male subjects were tested to determine the relationship between motor unit (MU) activities and surface electromyogram (EMG) power spectral parameters with contractions increasing linearly from zero to 80% of maximal voluntary contraction (MVC). Intramuscular spike and surface EMG signals recorded simultaneously from biceps brachii were analyzed by means of a computer-aided intramuscular MU spike amplitude-frequency (ISAF) histogram and an EMG frequency power spectral analysis. All measurements were made in triplicate and averaged. Results indicate that there were highly significant increases in surface EMG amplitude (71 +/- 31.3 to 505 +/- 188 microV, p less than 0.01) and mean power frequency (89 +/- 13.3 to 123 +/- 23.5 Hz, p less than 0.01) with increasing force. These changes were accompanied by progressive increases in the firing frequency of MU's initially recruited, and of newly recruited MU's with relatively larger spike amplitudes. The group data in the ISAF histograms revealed significant increases in mean spike amplitude (412 +/- 79 to 972 +/- 117 microV, p less than 0.01) and mean firing frequency (17.8 +/- 5.4 to 24.7 +/- 4.1 Hz, p less than 0.01). These data suggest that surface EMG spectral analysis can provide a sensitive measure of the relative changes in MU activity during increasing force output.  相似文献   

19.
Bovine viral diarrhoea continues to be an important disease affecting both beef and dairy animals of all ages. One of the quickest means of measuring bovine viral diarrhoea virus (BVDV) exposure and infection in the herd is a serum neutralization (SN) assay. Type 1 and type 2 BVDV SN results from the Animal Disease Research and Diagnostic Laboratory at South Dakota State University were collected over a seven-year period (1995-2001) to determine any trends. These results indicated that in 1996, 31% of the animals had titres > or =512 while in 2001, 74% of the titres were > or = 512. There has been a progressive increase over the seven-year period in the number of cases with titres > or = 512 with the exception of 1999 when there was a slight decrease. When analyzing the titres greater than 512, a further increase was seen. In 1995, 80% of the titres were < or = 1024 and 20% were 2048 and no titres were >2048. In 2001, 47% of the antibody levels were < or = 1024 while 53% were < or =2048 and 30% were >4096. The most dramatic increase in titres occurred in 1997 and the percentage of animals with titres from 512-8192 has remained fairly constant for the last five years (1997-2001). This increase is in part due to more extensive use of vaccination but probably also reflects a rise in field infections. In the future, standardizing existing BVDV SN serology along with developing new BVDV serology methods is necessary to provide continuity for any full-scale eradication programme.  相似文献   

20.
Two microplot experiments in 1981 and 1983 provided information on the effect of different population densities of Meloidogyne incognita race 1 and yield of sweet pepper. Microplots were square concrete pipes (30 × 30 cm and 50 cm long) filled with 40 liters of soil infested with 0, 0.062, 0.125, 0.25, 0.5, 1, 2, 4, 8, 16, 32, 64, 128, 256, and 512 eggs and juveniles/cm³ soil. Tolerance limits of 2.2 and 0.165 eggs and juveniles/cm³ soil and minimum yields of 58% and 20% of the controls were obtained in 1981 and 1983, respectively. Maximum reproduction rates of the nematode were 274 and 1,498 at the lowest initial population density. The population of the nematode declined rapidly after harvest, and only 13% and 6.5% of eggs and juveniles were detected in the soil after 1 and 6 months, respectively.  相似文献   