首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ABSTRACT:?

This review focuses on the hydrodynamic and mass transfer characteristics of various three-phase, gaslift fluidized bioreactors. The factors affecting the mixing and volumetric mass transfer coefficient (kLa), such as liquid properties, solid particle properties, liquid circulation velocity, superficial gas velocity, bioreactor geometry, are reviewed and discussed. Measurement methods, modeling and empirical correlations are reviewed and compared. To the authors' knowledge, there is no 'generalized' correlation to calculate the volumetric mass transfer coefficient, instead, only 'type-specific' correlations are available in the literature. This is due to the difficulty in modeling the gaslift bioreactor, caused by the variation in geometry, fluid dynamics, and phase interactions. The most important design parameters reported in the literature are: gas hold-up, liquid circulation velocity, 'true' superficial gas velocity, mixing, shear rate, aeration rate and volumetric mass transfer coefficient, kLa.  相似文献   

2.
Although a lot of research has been done into modelling microbial processes, the applicability of these concepts to problems specific for bioreactor design and optimization of process conditions is limited. This is partly due to the tendency to separate the two essential factors of bioreactor modelling, i.e. physical transport processes and microbial kinetics. The deficiencies of these models become especially evident in industrial production processes where O2 supply is likely to become the limiting factor, e.g. production of gibberellic acid and other organic acids. Hydrodynamics, mass transfer and rheology of gibberellic acid production by Gibberella fujikuroi in an airlift bioreactor is presented in this work. Important hydrodynamic parameters such as gas holdup, liquid velocity in the riser and in the downcomer, and mixing time were determined and correlated with superficial gas velocity in the riser. Mass transfer was studied evaluating the volumetric mass transfer coefficient, which was determined as a function of superficial gas velocity in the riser and as a function of fermentation time. Culture medium rheology was studied through fermentation time and allowed to explain the volumetric mass transfer coefficient behaviour. Rheological behaviour was explained in terms of changes in the morphology of the fungus. Finally, rheological studies let us obtain correlations for gas holdup and volumetric mass transfer coefficient estimation using the superficial gas velocity in the riser and the culture medium apparent viscosity.  相似文献   

3.
The hydrodynamic characteristics and the overall volumetric oxygen transfer coefficient of a new multi-environment bioreactor which is an integrated part of a wastewater treatment system, called BioCAST, were studied. This bioreactor contains several zones with different environmental conditions including aerobic, microaerophilic and anoxic, designed to increase the contaminant removal capacity of the treatment system. The multi-environment bioreactor is designed based on the concept of airlift reactors where liquid is circulated through the zones with different environmental conditions. The presence of openings between the aerobic zone and the adjacent oxygen-depleted microaerophilic zone changes the hydrodynamic properties of this bioreactor compared to the conventional airlift designs. The impact of operating and process parameters, notably the hydraulic retention time (HRT) and superficial gas velocity (U G), on the hydrodynamics and mass transfer characteristics of the system was examined. The results showed that liquid circulation velocity (V L), gas holdup (ε) and overall volumetric oxygen transfer coefficient ( $ k_{\text{L}} a_{\text{L}} $ ) increase with the increase of superficial gas velocity (U G), while the mean circulation time (t c) decreases with the increase of superficial gas velocity. The mean circulation time between the aerobic zone (riser) and microaerophilic zone (downcomer) is a stronger function of the superficial gas velocity for the smaller openings (1/2 in.) between the two zones, while for the larger opening (1 in.) the mean circulation time is almost independent of U G for U G ≥ 0.023 m/s. The smaller openings between the two zones provide higher mass transfer coefficient and better zone generation which will contribute to improved performance of the system during treatment operations.  相似文献   

4.
The influence of Aspergillus niger broth rheology, bioreactor geometry, and superficial gas velocity on the volumetric liquid phase oxygen transfer coefficient (k(L)a(L)), riser gas holdup (epsilon(GR)), and circulating liquid velocity (u(LR)) was studied in a bubble column (BC) and two external-circulation-loop airlift (ECLAL) bioreactors. The results are compared to those of previous studies on homogeneous fluids and in particular with a recent study on non-Newtonian carboxymethylcellulose (CMC) solutions conducted in the same contactors used for the A. niger fermentations. As expected from the CMC-based studies, in the heterogeneous broths of A. niger epsilon(GR), k(L)a(L), and u(LR) decreased with increasing broth apparent viscosity; epsilon(GR) and k(L)a(L) decreased with increasing downcomer-to-riser cross-sectional area ratio, A(d)/A(r), whereas u(LR) increased with increasing A(d)/A(r). Gas holdup data in the airlift fermentations of A. niger were well predicted by the CMC-based correlation. However, the CMC-based correlations produced conservative estimations of k(L)a(L) and overestimates of u(LR) compared to the observed values in the A. niger broths.  相似文献   

5.
Conventional airlift reactors are not adequate to carry out variable volume processes since it is not possible to achieve a proper liquid circulation in these reactors until the liquid height is higher than that of the downcomer. To carry out processes of variable volume, the use of a split-cylinder airlift reactor is proposed, in the interior of which two multi-perforated vertical baffles are installed in order to provide several points of communication between the reactor riser and downcomer. This improves the liquid circulation and mixing at any liquid volume. In fed-batch cultures, it is important to know how liquid height affects the hydrodynamic characteristics and the volumetric oxygen transfer coefficient since this impacts on the kinetic behavior of any fermentation. Thus, in the present work, the effect of the liquid height on the mixing time, the overall gas hold-up, and the volumetric oxygen transfer coefficient of the proposed airlift reactor were determined. The mixing time was increased and the volumetric oxygen transfer coefficient decreased due to the increase of the liquid height in the reactor in all the superficial gas velocities tested, which corresponded to a pseudohomogeneous flow regime. The experimental values of the mixing time and the mass-transfer coefficient were properly described through correlations in which the UGR/HL ratio was used as the independent variable. Thus, this variable might be used to describe the hydrodynamic behavior and the oxygen transfer coefficient of airlift reactors when such reactors are used in processes where the liquid volume changes with time. However, these correlations are useful for the particular device and for the particular operating conditions at which they were obtained. These empirical correlations are useful to understand some factors that influence the mixing time and volumetric oxygen transfer coefficient, but such correlations do not have a sufficient predictive potential for a satisfactory reactor design. The overall gas hold-up values were not significantly affected when the liquid height was lower than the downcomer height. However, the values decreased abruptly when the reactor was operated with liquid heights over the downcomer height, especially at high superficial gas velocities.  相似文献   

6.
This work describes the engineering characterization of miniature (2 mL) and laboratory-scale (100 mL) bubble column bioreactors useful for the cultivation of microbial cells. These bioreactors were constructed of glass and used a range of sintered glass gas diffusers with differently sized pores to disperse humidified air within the liquid biomedium. The effect of the pressure of this supplied air on the breakthrough point for gas diffusers with different pore sizes was examined and could be predicted using the Laplace-Young equation. The influence of the superficial gas velocity (u(g)) on the volumetric mass transfer coefficient (k(L)a) was determined, and values of up to 0.09 s(-1) were observed in this work. Two modeling approaches were considered in order to predict and provide comparison criteria. The first related the volumetric power consumption (P/V) to the k(L)a and a good correlation was obtained for differently sized reactors with a given pore size, but this correlation was not satisfactory for bubble columns with different gas diffusers. Values for P/V ranged from about 10 to 400 W.m(-3). Second, a model was developed predicting bubble size (d(b)), bubble rising velocity (u(b)), gas hold-up (phi), liquid side mass transfer coefficient (k(L)), and thus the k(L)a using established theory and empirical correlations. Good agreement was found with our experimental data at different scales and pore sizes. Values for d(b) varied from 0.1 to 0.6 mm, and k(L) values between 1.7 and 9.8 x 10(-4) m.s(-1) were determined. Several E. coli cultivations were performed in the miniature bubble column at low and high k(L)a values, and the results were compared to those from a conventional stirred tank operated under identical k(L)a values. Results from the two systems were similar in terms of biomass growth rate and carbon source utilization.  相似文献   

7.
The aerated stirred reactor (ASR) has been widely used in biochemical and wastewater treatment processes. The information describing how the activated sludge properties and operation conditions affect the hydrodynamics and mass transfer coefficient is missing in the literature. The aim of this study was to investigate the influence of flow regime, superficial gas velocity (U(G)), power consumption unit (P/V(L)), sludge loading, and apparent viscosity (mu(ap)) of activated sludge fluid on the mixing time (t(m)), gas hold-up (epsilon), and volumetric mass transfer coefficient (k(L)a) in an activated sludge aerated stirred column reactor (ASCR). The activated sludge fluid performed a non-Newtonian rheological behavior. The sludge loading significantly affected the fluid hydrodynamics and mass transfer. With an increase in the U(G) and P/V(L), the epsilon and k(L)a increased, and the t(m), decreased. The epsilon, k(L)a, and t(m), were influenced dramatically as the flow regime changed from homogeneous to heterogeneous patterns. The proposed mathematical models predicted the experimental results well under experimental conditions, indicating that the U(G), P/V(L), and mu(ap) had significant impact on the t(m), epsilon, and k(L)a. These models were able to give the t(m), epsilon, and k(L)a values with an error around +/-8%, and always less than +/-10%.  相似文献   

8.
In the present study the oxygen mass transfer from the gas to the aqueous phase in a Three-Phase Inverse Fluidized Bed (TPIFB) has been studied. A pilot scale TPIFB has been designed and constructed. For determination of the volumetric oxygen mass transfer coefficient the elegant dynamic method, described by Dang et al. (1977) was used. The influence of hydrodynamic parameters, e.g., superficial velocities of the gas and liquid phases on the mass transfer rate was studied. In the range of variables covered, it was found that the superficial liquid velocity had a weak effect on the mass transfer whereas the gas flowrate affects the mass transfer positively. The results for the volumetric oxygen transfer coefficient in the TPIFB were compared to reported values of that coefficient, measured in a classic three-phase fluidised bed under similar hydrodynamic conditions and solid phase properties. The comparison demonstrated a two-fold increase of the oxygen transfer rate in the inverse bed over that in the classic one.  相似文献   

9.
Differing findings on the volumetric mass transfer coefficients k(L)a in CMC solutions in bubble column bioreactors have been reported in the literature. Therefore, oxygen mass transfer was studied again in CMC solutions in a 14-cm-i.d. x 270-cm-height bubble column using different spargers. The k(L)a values were determined along with the dispersion coefficients by fitting the prediction of the axial dispersed plug model with the experimental oxygen concentration profiles in the liquid phase. Surprisingly, the obtained liquid phase dispersion coefficients for CMC solution are higher than one would expect from correlations. The k(L)a data depend largely on the flow regime. In general, they are lower than those reported in the literature. The data for developing slug and established slug flow are dependent on the gas velocity and the effective viscosity of the solution and can br correlated by a simple correlation. This correlation describes k(L)a values measured on fermentation broth of Penicillium chrysogenum with striking agreement.  相似文献   

10.
Miniature parallel bioreactors are becoming increasingly important as tools to facilitate rapid bioprocess design. Once the most promising strain and culture conditions have been identified a suitable scale-up basis needs to be established in order that the cell growth rates and product yields achieved in small scale optimization studies are maintained at larger scales. Recently we have reported on the design of a miniature stirred bioreactor system capable of parallel operation [Gill et al. (2008); Biochem Eng J 39:164-176]. In order to enable the predictive scale-up of miniature bioreactor results the current study describes a more detailed investigation of the bioreactor mixing and oxygen mass transfer characteristics and the creation of predictive engineering correlations useful for scale-up studies. A Power number of 3.5 for the miniature turbine impeller was first established based on experimental ungassed power consumption measurements. The variation of the measured gassed to ungassed power ratio, P(g)/P(ug), was then shown to be adequately predicted by existing correlations proposed by Cui et al. [Cui et al. (1996); Chem Eng Sci 51:2631-2636] and Mockel et al. [Mockel et al. (1990); Acta Biotechnol 10:215-224]. A correlation relating the measured oxygen mass transfer coefficient, k(L)a, to the gassed power per unit volume and superficial gas velocity was also established for the miniature bioreactor. Based on these correlations a series of scale-up studies at matched k(L)a (0.06-0.11 s(-1)) and P(g)/V (657-2,960 W m(-3)) were performed for the batch growth of Escherichia coli TOP10 pQR239 using glycerol as a carbon source. Constant k(L)a was shown to be the most reliable basis for predictive scale-up of miniature bioreactor results to conventional laboratory scale. This gave good agreement in both cell growth and oxygen utilization kinetics over the range of k(L)a values investigated. The work described here thus gives further insight into the performance of the miniature bioreactor design and will aid its use as a tool for rapid fermentation process development.  相似文献   

11.
Gas holdup, mixing, liquid circulation and gas–liquid oxygen transfer were characterized in a large (∼1.5 m3) draft-tube airlift bioreactor agitated with Prochem® hydrofoil impellers placed in the draft-tube. Measurements were made in water and in cellulose fiber slurries that resembled broths of mycelial microfungi. Use of mechanical agitation generally enhanced mixing performance and the oxygen transfer capability relative to when mechanical agitation was not used; however, the oxygen transfer efficiency was reduced by mechanical agitation. The overall volumetric gas–liquid mass transfer coefficient declined with the increasing concentration of the cellulose fiber solids; however, the mixing time in these strongly shear thinning slurries was independent of the solids contents (0–4% w/v). Surface aeration never contributed more than 12% to the total mass transfer in air–water.  相似文献   

12.
Enzymatic oxidation of lactose to lactobionic acid (LBA) by a carbohydrate oxidase from Microdochium nivale was studied in a pilot-scale batch reactor of 600 L working volume using a rotary jet head (RJH) for mixing and mass transfer (Nordkvist et al., 2003, Chem Eng Sci 58:3877-3890). Both lactose and whey permeate were used as substrate, air was used as oxygen source, and catalase was added to eliminate the byproduct hydrogen peroxide. More than 98% conversion to LBA was achieved. Neither enzyme deactivation nor enzyme inhibition was observed under the experimental conditions. The dissolved oxygen tension (DOT) was constant throughout the tank for a given set of operating conditions, indicating that liquid mixing was sufficiently good to avoid oxygen gradients in the tank. However, at a given oxygen tension measured in the tank, the specific rate of reaction found in the RJH system was somewhat higher than previously obtained in a 1 L mechanically stirred tank reactor (Nordkvist et al., 2007, in this issue, pp. 694-707). This can be ascribed to a higher pressure in the recirculation loop which is part of the RJH system. Compared to mechanically stirred systems, high values of the volumetric mass transfer coefficient, k(L)a, were obtained when lactose was used as substrate, especially at low values of the specific power input and the superficial gas velocity. k(L)a was lower for experiments with whey permeate than with lactose due to addition of antifoam. The importance of mass transfer and of the saturation concentration of oxygen on the volumetric rate of reaction was demonstrated by simulations.  相似文献   

13.
A bubble column fitted with an ejector has been tested for its physical and biological performance. The axial diffusion coefficient of the liquid phase in the presence of electrolytes and ethanol was measured by a stimulus-response technique with subsequent evaluation by means of a diffusion model. In contrast to ordinary bubble columns, the coefficient of axial mixing is inversely dependent on the superficial air velocity. The liquid velocity acts in an opposite direction to the backmixing flow in the column. The measurement of volumetric oxygen transfer coefficient in the presence of electrolytes and ethanol was performed using a dynamic gassing-in method adapted for a column. The data were correlated with the superficial air and liquid velocities, total power input, and power for aeration and mixing; the economy coefficient of oxygen transfer was used for finding an optimum ratio of power for aeration and pumping. Growth experiments with Candida utilis on ethanol confirmed some of the above results. Biomass productivity of 2.5 g L(-1) h(-1) testifies about a good transfer capability of the column. Columns fitted with pneumatic and/or hydraulic energy input may be promising for aerobic fermentations considering their mass transfer and mixing characteristics.  相似文献   

14.
三相逆流湍动床气液传质性能的研究   总被引:1,自引:0,他引:1  
由空气-水(清水/废水)-中空玻璃珠构成三相体系,在表观气速0·53~10mm·s-1、固含率为0~0·3、表观液速0~0·2mm·s-1的条件下,采用溶氧仪研究了三相逆流湍动床的气液传质性能,考察了操作参数和液体性质对液相容积传质系数kLa的影响。结果表明,在所试条件下,kLa为0·0456~1·414min-1。kLa随着表观气速和表观液速的增加而增加,随着固含率的增加先增加后减小,0·05~0·08为反应器传质的最优固含率条件。液体性质对kLa有重大影响,高浓度模拟废水和工业废水中的kLa比清水中的kLa分别减小39·0%和50·9%。研究结果可为后续逆流湍动床废水生物处理过程分析与模拟提供传质基础数据。  相似文献   

15.
Longer mixing times and higher power consumption are common problems in the design of photobioreactors. In this study, a vertical triangular external airlift loop photobioreactor was designed, constructed and operated for microalgae production studies. Gas feeding was performed by two spargers: one at the bottom of the hypotenuse (downcomer) and another at the bottom of the vertical side (riser). This configuration provided more effective countercurrent liquid–gas flow in the hypotenuse. The mass transfer coefficient, gas hold-up, mixing time, circulation time, dimensionless mixing time, bubble size, and volumetric power consumption were measured and optimized using response surface methodology. Investigations were carried out on the performance of the riser (the vertical side), downcomer (the hypotenuse), and separator. The countercurrent flow in the hypotenuse provided sufficient contact between gas and liquid phases, and increased mixing and mass transfer rates, in contrast to the results of previous studies. The promising results of this geometry were shorter mixing time and a significant decrease in volumetric power consumption in comparison with other configurations for photobioreactors.  相似文献   

16.
A new scalable reactor was developed by applying a novel mixing principle that allows the large-scale cultivation of mammalian cells simply with surface aeration using air owing to increased liquid-gas transfer compared to standard stirred-tank bioreactors. In the cylindrical vessels (50 mL-1500 L) with a helical track attached to the inside wall, the liquid moved upward onto the track as the result of orbital shaking to increase the liquid-gas interface area significantly. This typically resulted in a 5-10-fold improvement in the volumetric mass transfer coefficient (k(L)a). In a 1500-L helical track vessel with a working volume of 1000 L, a k(L)a of 10h(-1) was obtained at a shaking speed of 39 rpm. Cultivations of CHO cells in a shaken 55-L helical track bioreactor resulted in improved cell growth profiles compared to control cultures in standard systems. These results demonstrated the possibility of using these new bioreactors at scales of 1000 L or more.  相似文献   

17.
The two major types of airlift contactors, concentric-tube and external-loop, were investigated for their gas holdup (riser and downcomer) and overall mass transfer characteristics. Results obtained in batch charges of tap water and 0.15 kmol/m(3) NaCl solution are reported for external-loop airlift contactors having downcomer-to-riser cross-sectional area ratios, A(d)/A(r), ranging from 0.11 相似文献   

18.
The theoretical and experimental aspects of the hydrodynamics and mixing in a new multi-environment bioreactor that uses the air-lift design were investigated. This study focused on the mixing characteristics, residence time distribution, liquid circulation between three zones of aerobic, microaerophilic and anoxic, and liquid displacement in the bioreactor at influent flow rates of 720–1,450 L/day and air flow rates of 15–45 L/min. The theoretical analysis of liquid displacement led to the estimation of the specific rate of liquid discharge from the bioreactor at any given influent flow rate, and the number of liquid circulations between various bioreactor zones before the discharge of a given quantity of wastewater. The ratio of mean residence time to the overall hydraulic retention time (t m/HRT) decreased with the increase of air flow rate at any given influent flow rate, and approached unity at higher air flow rates. Mixing was characterized in terms of the axial dispersion coefficient and Bodenstein number, demonstrating a linear relationship with the superficial gas velocity. A correlation was developed between the Bodenstein number and the Froude number. The study of liquid circulation between the zones showed that less than 1.5 % of the circulating liquid escapes circulation at each cycle and flows towards the outer clarifier, while the percentage of escaped liquid decreases with increasing air flow rate at a given influent flow rate. The specific rate of liquid discharge from the bioreactor increased from 0.19 to 0.69 h?1 with the increase of air and influent flow rates from 15 to 45 L/min and 500 to 1,450 L/day, respectively. Under the examined operating conditions, mixed liquor circulates between 364 and 1,698 times between the aerobic, microaerophilic and anoxic zones before 99 % of its original volume is replaced by the influent wastewater.  相似文献   

19.
Data on volumetric mass-transfer coefficient, KLaL, in a 12 × 10−3 m3 airlift bioreactor are reported. Measurements were made in sea water. The superficial gas velocity ranged up to 0.21 m/s. Four cylindrical spargers (60–1000 μm pore size) were tested. In bubbly flow, the sparger pore size strongly influenced the KLaL; the highest KLaL values were obtained with the smallest pore size. In contrast, in the transition and heterogeneous flow regimes, the pore size had little influence on KLaL. The best correlation of the mass transfer data was obtained when both gas holdup and liquid superficial velocity were taken as independent variables. Shear rates were estimated in the different zones of the reactor. The highest values were found in the bottom zone of the reactor and in the gas-liquid separator. The penetration and isotropic turbulence models were used to develop a semi-theoretical equation relating the volumetric mass-transfer coefficient to shear rate; hence providing a better understanding of how the operational variables may be manipulated to attain a moderate shear rate and an appropriate level of mass transfer, two extremely important parameters for the growth of sensible microorganisms as those used in marine biotechnology.  相似文献   

20.
A general relationship for prediction of the volumetric oxygen transfer coefficient (kLa) in a tower bioreactor utilizing immobilized Penicillium chrysogenum as function of air superficial velocity, suspension rheological parameters and liquid physical properties is proposed in this study. The relationship was applied to three different systems and a good agreement between the calculated values and the experimental data was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号