首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
OBJECTIVE:: The purpose of this consensus conference was to determine whether video-assisted thoracic surgery (VATS) improves clinical and resource outcomes compared with conventional thoracotomy (OPEN) in adults undergoing lobectomy for lung cancer, and to outline evidence-based recommendations for the use of VATS in performing lobectomy for lung cancer. METHODS:: Before the consensus conference, the best available evidence was reviewed in that systematic reviews, randomized trials, and nonrandomized trials were considered in descending order of validity and importance. At the consensus conference, evidence-based statements were created, and consensus processes were used to determine the ensuing recommendations. The American Heart Association/American College of Cardiology system was used to label the level of evidence and class of recommendation. RESULTS AND RECOMMENDATIONS:: The consensus panel agreed upon the following statements and recommendations in patients with clinical stage I nonsmall cell lung cancer undergoing lung lobectomy:  相似文献   

3.
OBJECTIVE:: This purpose of this consensus conference was to determine whether surgical atrial fibrillation (AF) ablation during cardiac surgery improves clinical and resource outcomes compared with cardiac surgery alone in adults undergoing cardiac surgery for valve or coronary artery bypass grafting. METHODS:: Before the consensus conference, the consensus panel reviewed the best available evidence, whereby systematic reviews, randomized trials, and nonrandomized trials were considered in descending order of validity and importance. Evidence-based statements were created, and consensus processes were used to determine the ensuing recommendations. The American Heart Association/American College of Cardiology system was used to label the level of evidence and class of recommendation. RESULTS:: The consensus panel agreed on the following statements in patients with AF undergoing cardiac surgery concomitant surgical ablation: CONCLUSIONS:: Given these evidence-based statements, the consensus panel stated that, in patients with persistent and permanent AF undergoing cardiac surgery, concomitant surgical ablation is recommended to increase incidence of sinus rhythm at short- and long-term follow-up (class 1, level A); to reduce the risk of stroke and thromboembolic events (class 2a, level B); to improve EF (class 2a, level A); and to exercise tolerance (class 2a, level A) and long-term survival (class 2a, level B).  相似文献   

4.
OBJECTIVE:: This purpose of this consensus statement was to compare endoscopic vascular graft harvesting (EVH) with conventional open vascular harvesting (OVH) in adults undergoing coronary artery bypass grafting (CABG) surgery and to determine which resulted in improved clinical and resource outcomes. METHODS:: Before the consensus conference, the consensus panel reviewed the best available evidence, whereby systematic reviews, randomized trials, and nonrandomized trials were considered in descending order of importance. Evidence-based statements were created, and consensus processes were used to determine the ensuing statements. The AHA/ACC system was used to label the level of evidence and class of recommendation. RESULTS:: The consensus panel agreed upon the following statements: CONCLUSIONS:: Given these evidence-based statements, the consensus panel stated that EVH should be the standard of care for patients who require saphenous vein grafts for coronary revascularization (Class I, Level B). Future research should address long-term safety, cost-effectiveness, and endoarterial harvest.  相似文献   

5.
OBJECTIVE:: This meta-analysis sought to determine whether stentless bioprosthetic valves improve clinical and resource outcomes compared with stented valves in patients undergoing aortic valve replacement. METHODS:: A comprehensive search was undertaken to identify all randomized and nonrandomized controlled trials comparing stentless to stented bioprosthetic valves in patients undergoing aortic valve replacement available up to March 2008. The primary outcomes were clinical and resource outcomes in randomized controlled trial (RCT). Secondary outcomes clinical and resource outcomes in nonrandomized controlled trial (non-RCT). Odds ratios (OR), weighted mean differences (WMD), or standardized mean differences and their 95% confidence intervals (CI) were analyzed as appropriate. RESULTS:: Seventeen RCTs published in 23 articles involving 1317 patients, and 14 non-RCTs published in 18 articles involving 2485 patients were included in the meta-analysis. For the primary analysis of randomized trials, mortality for stentless versus stented valve groups did not differ at 30 days (OR 1.36, 95% CI 0.68-2.72), 1 year (OR 1.01, 95% CI 0.55-1.85), or 2 to 10 years follow-up (OR 0.82, 95% CI 0.50-1.33). Aggregate event rates for all-cause mortality at 30 days were 3.7% versus 2.9%, at 1 year were 5.5% versus 5.9% and at 2 to 10 years were 17% versus 19% for stentless versus stented valve groups, respectively. Stroke or neurologic complications did not differ between stentless (3.6%) and stented (4.0%) valve groups. Risk of prosthesis-patient mismatch was numerically lower in the stentless group (11.0% vs. 31.3%, OR 0.30, 95% CI 0.05-1.66), but this parameter was reported in few trials and did not reach statistical significance. Effective orifice area index was significantly greater for stentless aortic valve compared with stented valves at 30 days (WMD 0.12 cm/m), at 2 to 6 months (WMD 0.15 cm/m), and at 1 year (WMD 0.26 cm/m). Mean gradient at 1 month was significantly lower in the stentless valve group (WMD -6 mm Hg), at 2 to 6 month follow-up (WMD -4 mm Hg,), at 1 year follow-up (WMD -3 mm Hg) and up to 3 year follow-up (WMD -3 mm Hg) compared with the stented valve group. Although the left ventricular mass index was generally lower in the stentless group versus the stented valve group, the aggregate estimates of mean difference did not reach significance during any time period of follow-up (1 month, 2-6 months, 1 year, and 8 years). CONCLUSIONS:: Evidence from randomized trials shows that subcoronary stentless aortic valves improve hemodynamic parameters of effective orifice area index, mean gradient, and peak gradient over the short and long term. These improvements have not led to proven impact on patient morbidity, mortality, and resource-related outcomes; however, few trials reported on clinical outcomes beyond 1 year and definitive conclusions are not possible until sufficient evidence addresses longer-term effects.  相似文献   

6.
《Endocrine practice》2021,27(3):174-184
ObjectivesTo provide a clinical disease state review of recent relevant literature and to generate expert consensus statements regarding the breadth of pediatric thyroid cancer diagnosis and care, with an emphasis on thyroid surgery. To generate expert statements to educate pediatric practitioners on the state-of-the-art practices and the value of surgical experience in the management of this unusual and challenging disease in children.MethodsA literature search was conducted and statements were constructed and subjected to a modified Delphi process to measure the consensus of the expert author panel. The wording of statements, voting tabulation, and statistical analysis were overseen by a Delphi expert (J.J.S.).ResultsTwenty-five consensus statements were created and subjected to a modified Delphi analysis to measure the strength of consensus of the expert author panel. All statements reached a level of consensus, and the majority of statements reached the highest level of consensus.ConclusionPediatric thyroid cancer has many unique nuances, such as bulky cervical adenopathy on presentation, an increased incidence of diffuse sclerosing variant, and a longer potential lifespan to endure potential complications from treatment. Complications can be a burden to parents and patients alike. We suggest that optimal outcomes and decreased morbidity will come from the use of advanced imaging, diagnostic testing, and neural monitoring of patients treated at high-volume centers by high-volume surgeons.  相似文献   

7.
Lasers have in principle the capability to cut at the level of a single cell, the fundamental limit to minimally invasive procedures and restructuring biological tissues. To date, this limit has not been achieved due to collateral damage on the macroscale that arises from thermal and shock wave induced collateral damage of surrounding tissue. Here, we report on a novel concept using a specifically designed Picosecond IR Laser (PIRL) that selectively energizes water molecules in the tissue to drive ablation or cutting process faster than thermal exchange of energy and shock wave propagation, without plasma formation or ionizing radiation effects. The targeted laser process imparts the least amount of energy in the remaining tissue without any of the deleterious photochemical or photothermal effects that accompanies other laser wavelengths and pulse parameters. Full thickness incisional and excisional wounds were generated in CD1 mice using the Picosecond IR Laser, a conventional surgical laser (DELight Er:YAG) or mechanical surgical tools. Transmission and scanning electron microscopy showed that the PIRL laser produced minimal tissue ablation with less damage of surrounding tissues than wounds formed using the other modalities. The width of scars formed by wounds made by the PIRL laser were half that of the scars produced using either a conventional surgical laser or a scalpel. Aniline blue staining showed higher levels of collagen in the early stage of the wounds produced using the PIRL laser, suggesting that these wounds mature faster. There were more viable cells extracted from skin using the PIRL laser, suggesting less cellular damage. β-catenin and TGF-β signalling, which are activated during the proliferative phase of wound healing, and whose level of activation correlates with the size of wounds was lower in wounds generated by the PIRL system. Wounds created with the PIRL systsem also showed a lower rate of cell proliferation. Direct comparison of wound healing responses to a conventional surgical laser, and standard mechanical instruments shows far less damage and near absence of scar formation by using PIRL laser. This new laser source appears to have achieved the long held promise of lasers in minimally invasive surgery.  相似文献   

8.
9.
10.
John C. Callaghan 《CMAJ》1964,91(9):411-421
The aortic and mitral valves were replaced in 50 patients at the University of Alberta Hospital using the Starr-Edwards ball-valve prosthesis. The basis of the selection of 20 patients for isolated aortic valve replacement and 27 for mitral valve replacement using this type of prosthesis is presented, and the techniques of insertion of the aortic and mitral valve are described in detail. Of the 27 patients in whom the mitral valve was replaced by the Starr-Edwards prosthesis six died within 30 days of surgery and two after discharge from hospital at two and a half and four months, respectively. Left atrial thrombosis was the cause of death in four of these patients. In 20 patients in whom the aortic valve was replaced, four died in hospital and two died more than 30 days after returning home. Three of these six patients died from bleeding—the result of the use of anticoagulants. The difficulty in assessing whether or not anticoagulants are needed following replacement by a Starr-Edwards prosthesis is considered. It is felt, in our present state of knowledge, that anticoagulants should be used following mitral valve replacement but are probably not essential following replacement of the aortic valve. Two patients survived replacement of both aortic and mitral valves and have been followed up 18 months and seven months, respectively.  相似文献   

11.
12.
13.
14.
15.
16.
17.
We present here some thoughts on the origin of the International Society of Photosynthesis Research (ISPR). We provide two tables, one of the Officers of the ISPR and the International Photosynthesis Committee, and the other of the Organizers of the International Congress of Photosynthesis (ICP) from the 14th ICP (PS07 in Glasgow) to the 9th ICP (in Nagoya). In celebration of the 14th ICP, we provide here a collection of photographs of the many involved in the ISPR and the ICP as well as some of the others. We end this presentation with the list of members of the committees of the ISPR. If there are any errors in this report, we request the readers to send them to one of us (G; gov@uiuc.edu). Further, we are seeking recollections on ISPR and the Congresses from all the readers of the events during the 1992–1998 period. Hopefully, these will shed further light on the origin and the evolution of the ISPR. These will aid in the preparation of a more complete history of the origin and the evolution of ISPR for publication in 2008.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏