首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
There has been significant improvement in device designs, operative techniques, and early clinical outcomes in <5 years. Presently, there are two catheter-based bioprostheses (balloon expandable or self-expandable), which have been widely used in humans and are undergoing clinical investigations. Three approaches, including transvenous, transarterial, and transapical have been used for delivery of the catheter-based bioprostheses, and transarterial and transapical approaches have been adopted by cardiologists and cardiac surgeons worldwide. The most recent clinical results have been very encouraging and promising. With experience, 30-day operative mortality with either balloon-expandable or self-expandable bioprosthesis was reduced significantly to approximately 10% in high-risk patients. In vivo long-term durability of catheter-based bioprostheses remains unknown, and presently transcatheter procedure is limited to the cohort of high-risk patients. Expanding this new technology to low-risk patients should be done with extreme caution because conventional aortic valve replacement still provides the best long-term outcome with minimal operative mortality and morbidity in low-risk patients. Ongoing clinical trials will address many unanswered questions, such as patient selection, long-term in vivo durability, preoperative assessment, and the role of the procedures in management of valvular diseases.  相似文献   

2.
3.
Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure introduced to treat aortic valve stenosis in elder patients. Its clinical outcomes are strictly related to patient selection, operator skills, and dedicated pre-procedural planning based on accurate medical imaging analysis. The goal of this work is to define a finite element framework to realistically reproduce TAVI and evaluate the impact of aortic root anatomy on procedure outcomes starting from two real patient datasets. Patient-specific aortic root models including native leaflets, calcific plaques extracted from medical images, and an accurate stent geometry based on micro-tomography reconstruction are key aspects included in the present study. Through the proposed simulation strategy we observe that, in both patients, stent apposition significantly induces anatomical configuration changes, while it leads to different stress distributions on the aortic wall. Moreover, for one patient, a possible risk of paravalvular leakage has been found while an asymmetric coaptation occurs in both investigated cases. Post-operative clinical data, that have been analyzed to prove reliability of the performed simulations, show a good agreement with analysis results. The proposed work thus represents a further step towards the use of realistic computer-based simulations of TAVI procedures, aiming at improving the efficacy of the operation technique and supporting device optimization.  相似文献   

4.
The complex structural organization of the aortic valve (AV) extracellular matrix (ECM) enables large and highly nonlinear tissue level deformations. The collagen and elastin (elastic) fibers within the ECM form an interconnected fibrous network (FN) and are known to be the main load-bearing elements of the AV matrix. The role of the FN in enabling deformation has been investigated and documented. However, there is little data on the correlation between tissue level and FN-level strains. Investigating this correlation will help establish the mode of strain transfer (affine or nonaffine) through the AV tissue as a key feature in microstructural modeling and will also help characterize the local FN deformation across the AV sample in response to applied tissue level strains. In this study, the correlation between applied strains at tissue level, macrostrains across the tissue surface, and local FN strains were investigated. Results showed that the FN strain distribution across AV samples was inhomogeneous and nonuniform, as well as anisotropic. There was no direct transfer of the deformation applied at tissue level to the fibrous network. Loading modes induced in the FN are different than those applied at the tissue as a result of different local strains in the valve layers. This nonuniformity of local strains induced internal shearing within the FN of the AV, possibly exposing the aortic valve interstitial cells (AVICs) to shear strains and stresses.  相似文献   

5.
6.

Objective

Permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI) is the most common complication after the procedure. PPMI rates remain high with the new-generation TAVI devices despite improved outcomes concerning paravalvular aortic regurgitation and vascular access complications. However, the impact of PPMI on mortality and clinical outcome is still a matter of debate, and data with new-generation devices on this matter are scarce. Therefore, we sought to analyse the influence of PPMI in patients treated with the new-generation devices on one-year outcome.

Methods

We enrolled 612 consecutive patients without prior pacemaker undergoing transfemoral TAVI with the new-generation devices. Patients with or without PPMI were compared with respect to clinical outcome within one year.

Results

PPMI was performed in 168 patients (24.4% of the overall study population). There was no significant difference in one-year outcome concerning all-cause mortality (PPMI vs. no-PPMI: 12.2% vs. 12.5%, p?=?0.94), rate of major adverse events including cardiac, cerebral or valve-related events and bleeding complications (22.1% vs. 24.5%, p?=?0.55) or need for rehospitalisation due to cardiac symptoms (16.1% vs. 18.1%, p?=?0.63). In patients with reduced ejection fraction (<45%) there was also no impact of PPMI on one-year mortality (14.3% vs. 15.7%, p?=?0.86). Furthermore, multivariate analysis did not reveal PPMI to be independently associated with one-year mortality (odds ratio 0.94, 95% confidence interval 0.50–1.74, p?=?0.83).

Conclusions

In this large all-comers TAVI population with new-generation devices the need for postprocedural PPMI did not show a statistical significant impact on survival or combined endpoint of major adverse events within one year.
  相似文献   

7.
Netherlands Heart Journal - We sought to investigate real-world outcomes of patients with degenerated biological aortic valve prostheses who had undergone valve-in-valve transcatheter aortic valve...  相似文献   

8.
Purpose: Elevated carbohydrate antigen 125 (CA125) predicts adverse outcome after transcatheter aortic valve implantation (TAVI). While known underlying pathophysiological mechanisms of elevated CA125 include serosal effusions and inflammatory stimuli, clinical determinants associated with elevated CA125 in patients referred for TAVI remain unknown. Therefore, we investigated clinical, laboratory and echocardiographic determinants of elevated CA125 in patients with severe aortic valve stenosis referred for TAVI.

Methods: This study includes 650 patients with severe aortic stenosis referred for TAVI. Baseline CA125 was determined by an immunoassay and dichotomized (elevated versus normal) based on the manufacturer cutoff value (>35?U/mL).

Results: CA125 elevation was present in 28% (181/650). Patients with elevated CA125 had an overall worse clinical profile and were more symptomatic with a higher rate of NYHA class III/IV (80% versus 58%; p?Conclusion: Elevated CA125 levels in patients referred for TAVI summarize a subset of patients with an overall worse clinical profile who are more symptomatic.  相似文献   

9.
10.
11.
12.
Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis.  相似文献   

13.
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy ( ? 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall ( ? 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.  相似文献   

14.
Abstract

Background: In this study we sought to examine whether transcatheter aortic valve implantation (TAVI) is followed by a change in the plasma levels of novel cardiovascular biomarkers.

Methods: We collected blood samples of 79 patients with severe aortic valve stenosis undergoing TAVI before and at 7 days, 1 month, 3 months and 6 months post TAVI and analyzed the plasma concentrations of GDF-15, H-FABP, fetuin-A, galectin 3, sST2 and suPAR by means of ELISA.

Results: There was a significant increase in the concentration of fetuin-A (median: 52.44 mg/ml to 113.2 mg/ml, p?<?0.001) and a significant decrease of H–FABP after TAVI (median: 4.835 ng/ml to 2.534 ng/ml, p?<?0.001). The concentrations of suPAR and sST2 showed an initial increase (suPAR median: 2755 pg/ml 3489 pg/ml, p?<?0.001; sST2 median: 5832 pg/ml to 7137 pq/ml, p?<?0.001) and subsequently decreased significantly.

Conclusion: We hypothesize that the decrease of H-FABP and the increase of fetuin-A could be due to a hemodynamic improvement after valve replacement. The initial increase of suPAR could indicate an inflammatory stimulus and the significant increase in sST2 could be due to the mechanical strain caused by implantation of the valve.  相似文献   

15.
An average follow-up period of 16 patients was 28 months following an implantation of the artificial aortic valve for its insufficiency. In 10 operated patients who were able to continue their occupation exercise tolerance increased by two classes, according to NYHA. Blood pressure gradient decreased significantly from 61.8 to 37.5 mmHg, cardiac volume index decreased from 639 to 602 ml/m2. Echocardiographically measured muscle mass of the left ventricle, end-diastolic and end-systolic volumes, and the left atrial dimensions decreased significantly following surgery. A significance of the relation of the left ventricle volume to its mass <4 as a prognostic factor in aortic valve replacement has also been confirmed.  相似文献   

16.
Aortic valve stenosis is one of the most common valvular abnormalities, which can manifest as angina, syncope, dyspnoea and sudden cardiac death. Transcath  相似文献   

17.
We represent a successful minimally invasive combined off-pump procedure consisting of a transapical aortic valve implantation and a direct coronary artery bypass grafting in a woman with a severe aortic stenosis and a critical coronary artery disease. Due to her comorbidities, she was classified as a high-risk patient qualifying for a transcatheter procedure. We performed this combined procedure in a hybrid operation room, starting with the coronary bypass to maintain a coronary blood flow during the transapical valve implantation. The operation processed without any complications and she was discharged at the seventh postoperative day into the allocating hospital.  相似文献   

18.
After its first introduction in 2002, transcatheter aortic valve implantation (TAVI) has continuously gained more foothold for the treatment of severe aortic stenosis and is nowadays a viable treatment option for inoperable patients or patients at high risk for conventional surgical aortic valve replacement. Although ideally carried out in a so-called hybrid room, incorporating both the strict hygiene and advanced life support possibilities of the operating theatre and the imaging and percutaneous arsenal of the catheterisation suite, in most centres TAVI is at present performed in the catheterisation laboratory. This may raise concern about an increased risk of infection, since there the criteria that are applied regarding disinfection and sterilisation are not as stringent as those of the operating theatre. Therefore, we retrospectively assessed the number of infective complications in patients undergoing TAVI in the catheterisation lab of our institution. Eleven out of 73 patients developed a postprocedural infection, one of which could be attributed to the procedure itself, being superinfection of a surgical groin cut-down. Our conclusion is that percutaneous aortic valve implantation in a catheterisation laboratory is not associated with an increased risk of infective complications.  相似文献   

19.
The Ross operation is a complex procedure for aortic valve replacement in which the pulmonary autograft is replaced by a homograft. However, homograft availability is becoming limited. This report evaluates the performance of porcine stentless prostheses as alternative pulmonary substitutes. Echocardiographic results from two patient cohorts were compared at time of discharge and 1 year after a Ross procedure. Thirty-three patients (median age 42 years, range 17–62 years, 76% male) received a stentless prosthesis (median size 25.6 mm, range 25–29 mm) for right ventricular outflow tract reconstruction. Clinical data were not significantly different from 106 patients (median age 47 years, range 2–68 years, 75% male) who received cryopreserved homografts (median size 26 mm, range 20–33 mm). At time of discharge, peak pressure gradients (ΔPmax) across the stentless valve (median ΔPmax 13 mmHg, range 2–26 mmHg) were higher compared to homografts (median ΔPmax 7 mmHg, range 1–32 mmHg, p<0.001). At 1 year, gradients increased in both groups, but were significantly higher across stentless valves (median ΔPmax 23 mmHg, range 10–81 mmHg vs. median ΔPmax 13 mmHg, range 2–74 mmHg, p<0.001). Eleven patients (33%) in the stentless-valve group were classified “at risk” with a ΔPmax of ≥30 mmHg. Four of them (12%) had to be re-operated. In conclusion, stentless valves showed higher pressure gradients and their performance was inferior to cryopreserved homografts. See accompanying commentary by Ulrich Stock DOI: 10.1002/biot.201200341  相似文献   

20.
Wen  Jun  Gao  Qi  Chen  Jingnan  Li  Xinya  Zhang  Kaiyue  He  Gang  Dai  Min  Song  Pan 《Biomechanics and modeling in mechanobiology》2023,22(4):1379-1394
Biomechanics and Modeling in Mechanobiology - Transcatheter aortic valve implantation (TAVI) is a micro-invasive surgery used to treat patients with aortic stenosis (AS) efficiently. However, the...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号