共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,672(1):138-142
A sensitive high-performance liquid chromatography method with electrochemical detection for measuring monoamine oxidase B activity in blood platelets is described. Dopamine is used as substrate and is incubated with isolated platelets and aldehyde dehydrogenase to convert dihydroxyphenylacetaldehyde to dihydroxyphenylacetic acid (DOPAC). The acid and the added internal standard hydrocaffeic acid are separated from dopamine and the incubation mixture by extraction with 5 ml of ethyl acetate-toluene (5:1, v/v). The organic phase is evaporated under nitrogen stream and the residue dissolved in 0.1 M critic acid. Dihydroxyphenylacetic acid and the internal standard dihydrocaffeic acid are then separated on the Eurosphere 100-C18 5 μm column. The mobile phase used was a mixture of sodium acetate, citric acid, and acetonitrile at pH 2.5. The standard curve was linear from 125 pg to 10 ng. Absolute recovery of DOPAC was 85±3.8% and of hydrocaffeic acid 87±4.1%. The method presented is sensitive (detection limit 8.0 pg of DOPAC injected) and reproducible (coefficient of variation 0.4-1%) with good accuracy (94–98%). 相似文献
2.
Nobumitsu Hanioka Norihisa Tatarazako Hideto Jinno Koji Arizono Masanori Ando 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,744(2):1
A sensitive method for the determination of cytochrome P450 (P450 or CYP) 1A activities such as ethoxyresorufin O-deethylase (EROD) and methoxyresorufin O-demethylase (MROD) in liver microsomes from human, monkey, rat and mouse by high-performance liquid chromatography with fluorescence detection is reported. The newly developed method was found to be more sensitive than previous methods using a spectrofluorimeter and fluorescence plate reader. The detection limit for resorufin (signal-to-noise ratio of 3) was 0.80 pmol/assay. Intra-day and inter-day precisions (expressed as relative standard deviation) were less than 6% for both enzyme activities. With this improved sensitivity, the kinetics of EROD and MROD activities in mammalian liver microsomes could be determined more precisely. EROD activities in human and monkey liver microsomes, and MROD activities in liver microsomes from all animal species exhibited a monophasic kinetic pattern, whereas the pattern of EROD activities in rat and mouse liver microsomes was biphasic. In addition, the method could determine the non-inducible and 3-methylcholanthrene-inducible activities of EROD and MROD in rat and mouse liver microsomes under the same assay conditions. Therefore, this method is applicable to in vivo and in vitro studies on the interaction of xenobiotic chemicals with cytochrome CYP1A isoforms in mammals. 相似文献
3.
Assay of mephenytoin metabolism in human liver microsomes by high-performance liquid chromatography 总被引:3,自引:0,他引:3
The metabolism of mephenytoin to its two major metabolites, 4-OH-mephenytoin (4-OH-M) and 5-phenyl-5-ethylhydantoin (nirvanol) was studied in human liver microsomes by a reversed phase HPLC assay. Because of preferential hydroxylation of S-mephenytoin in vivo, microsomes (5-300 micrograms protein) were incubated separately with S- and R-mephenytoin. After addition of phenobarbital as internal standard, the incubation mixture was extracted with dichloromethane. The residue remaining after evaporation was dissolved in water and injected on a 60 X 4.6-mm reversed-phase column (5 mu-C-18). Elution with acetonitrile/methanol/sodium perchlorate (20 mM, pH 2.5) led to almost baseline separation of mephenytoin, metabolites, and phenobarbital. Quantitation was performed by uv-absorption at 204 nm by the internal standard method. Propylene glycol was found to be the best solvent for mephenytoin, but inhibited the reaction noncompetitively. 4-OH-M and nirvanol could be detected at concentrations in the incubation mixture as low as 40 and 80 nM, respectively. The rates of metabolite formation were linear with time and protein concentration. The reaction was found to be substrate stereoselective. At substrate concentrations below 0.5 mM S-mephenytoin was preferentially hydroxylated to 4-OH-M, while R-mephenytoin was preferentially demethylated to nirvanol at all substrate concentrations tested (25-1600 microM). These data provide a mechanistic explanation for the stereospecific pharmacokinetics in vivo. The dependence of both metabolic relations on NADPH and the inhibition by CO suggest that they are mediated by cytochrome P-450-type monooxygenases.(ABSTRACT TRUNCATED AT 250 WORDS) 相似文献
4.
Samokyszyn VM Gall WE Zawada G Freyaldenhoven MA Chen G Mackenzie PI Tephly TR Radominska-Pandya A 《The Journal of biological chemistry》2000,275(10):6908-6914
It is suggested that formation of more polar metabolites of all-trans-retinoic acid (atRA) via oxidative pathways limits its biological activity. In this report, we investigated the biotransformation of oxidized products of atRA via glucuronidation. For this purpose, we synthesized 4-hydroxy-RA (4-OH-RA) in radioactive and nonradioactive form, 4-hydroxy-retinyl acetate (4-OH-RAc), and 5,6-epoxy-RA, all of which are major products of atRA oxidation. Glucuronidation of these retinoids by human liver microsomes and human recombinant UDP-glucuronosyltransferases (UGTs) was characterized and compared with the glucuronidation of atRA. The human liver microsomes glucuronidated 4-OH-RA and 4-OH-RAc with 6- and 3-fold higher activity than atRA, respectively. Analysis of the glucuronidation products showed that the hydroxyl-linked glucuronides of 4-OH-RA and 4-OH-RAc were the major products, as opposed to the formation of the carboxyl-linked glucuronide with atRA, 4-oxo-RA, and 5,6-epoxy-RA. We have also determined that human recombinant UGT2B7 can glucuronidate atRA, 4-OH-RA, and 4-OH-RAc with activities similar to those found in human liver microsomes. We therefore postulate that this human isoenzyme, which is expressed in human liver, kidney, and intestine, plays a key role in the biological fate of atRA. We also propose that atRA induces its own oxidative metabolism via a cytochrome P450 (CYP26) and is further biotransformed into glucuronides via UGT-mediated pathways. 相似文献
5.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,663(1):43-50
We report here a simple and sensitive method for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human plasma. Benzaldehyde, generated during a 1-h incubation of plasma with benzylamine, is derivatized with the specific aldehyde reagent dimedone after prior deproteinization. Quantitation of the derivatization product is done by automated injection onto an isocratic high-performance liquid chromatographic system with fluorimetric detection. The assay shows good linearity and reproducibility (intra-assay C.V. 7%). Detection limit is 25 mU/1 (= pmol/ml/min). In 51 healthy controls (age 49 ± 13 yr, 20 males) the measured SSAO activity was 352 ± 102 mU/1 (mean ± S.D.). A large number of samples (70–80) can easily be processed in one day by one technician. 相似文献
6.
A sensitive assay of aromatization of 16 alpha-hydroxylated androgens, 16 alpha-hydroxyandrostenedione (16 alpha-OHA), 16 alpha,19-dihydroxyandrostenedione [16 alpha,19-(OH)2A], and 16 alpha-hydroxy-19-oxo androstenedione (16 alpha-OH-19-oxo A), was developed using reversed phase high-performance liquid chromatography with a coulometric detector. The estrogens, estriol and 16 alpha-hydroxyestrone, were simultaneously detected in quantities as low as 300 pg of the estrogens formed in an assay by an internal standard method. Apparent Km and Vmax of the microsomal aromatase for 16 alpha-OHA, 16 alpha,19-(OH)2A or 16 alpha-OH-19-oxo A were 1.06, 4.00 or 571 microM and 0.014, 0.087 or 1.67 pmol/min/micrograms protein, respectively. The results show that the 19-oxo steroid has extremely low affinity for aromatase relative to the other substrates. 相似文献
7.
Lepper ER Hicks JK Verweij J Zhai S Figg WD Sparreboom A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,806(2):305-310
A liquid chromatographic assay with mass-spectrometric detection was developed for the quantitative determination of the cytochrome p450 3A phenotyping probe midazolam in human plasma. Sample pretreatment involved a one-step extraction of 600 microl aliquots with ethyl acetate. Midazolam and the internal standard, lorazepam, were separated on a column (150 mm x 4.6mm, i.d.) packed with 5 microm Zorbax Eclipse XDB-C8 material, using a mobile phase composed of methanol and 10mM aqueous ammonium acetate (60:40, v/v). Column effluents were analyzed using mass-spectrometry with an atmospheric pressure chemical ionization source. Calibration curves were linear in the concentration range of 1.00-200 ng/ml. The accuracy and precision ranged from 92.8 to 112% and 0.056 to 13.4%, respectively, for four different concentrations of quality control samples analyzed in triplicate on eight separate occasions. The developed method was subsequently applied to study the pharmacokinetics of midazolam in a group of 35 human subjects at a single dose of 25 microg/kg. 相似文献
8.
Barre L Fournel-Gigleux S Finel M Netter P Magdalou J Ouzzine M 《The FEBS journal》2007,274(5):1256-1264
The human UDP-glucuronosyltransferase (UGT) isoforms UGT2B4 and UGT2B7 play a major role in the detoxification of bile acids, steroids and phenols. These two isoforms present distinct but overlapping substrate specificity, sharing common substrates such as the bile acid hyodeoxycholic acid (HDCA) and catechol-estrogens. Here, we show that in UGT2B4, substitution of phenylalanine 33 by leucine suppressed the activity towards HDCA, and impaired the glucuronidation of several substrates, including 4-hydroxyestrone and 17-epiestriol. On the other hand, the substrate specificity of the mutant UGT2B4F33Y, in which phenylalanine was replaced by tyrosine, as found at position 33 of UGT2B7, was similar to wild-type UGT2B4. In the case of UGT2B7, replacement of tyrosine 33 by leucine strongly reduced the activity towards all the tested substrates, with the exception of 17-epiestriol. In contrast, mutation of tyrosine 33 by phenylalanine exhibited similar or even somewhat higher activities than wild-type UGT2B7. Hence, the results strongly indicated that the presence of an aromatic residue at position 33 is important for the activity and substrate specificity of both UGT2B4 and UGT2B7. 相似文献
9.
R. Lopez-Galera L. Pou-Clave C. Pascual-Mostaza 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,674(2)
A rapid reversed-phase high-performance liquid chromatographic method with a 30-mm long column is described for assaying amphotericin B in serum. After deproteinization of serum samples with methanol, the supernatant was injected onto a reversed-phase C18 column, using 2.5 mM Na2EDTA-acetonitrile (70:30, v/v) as the mobile phase. Amphotericin B was eluted at 1.5 min. Calibration plot of the peak area against concentration was linear from 0.05 to 25 μg/ml (C.V. of 3%). Within-day and day-to-day imprecision (C.V.) ranged between 1.33% and 3.61%. The application was evaluated in 55 serum samples from patients treated with amphotericin B. 相似文献
10.
A sensitive enzymatic assay to measure cholinesterase activity in serum using liquid chromatography with electrochemical detection has been devised and used to examine cholinesterase inhibition in mice treated with diisopropyl phosphorofluoridate. Acetylcholine was used as substrate, and a postcolumn reactor containing immobilized choline oxidase converted the enzymatic product, choline, and the internal standard, ethylhomocholine, into the electrochemically active H2O2. The postcolumn reactor also contained acetylcholinesterase to allow the indirect detection of the substrate. Assay optimization included investigations of substrate concentration, buffer pH and ionic strength, enzyme concentration, incubation time, and reaction termination method. The optimized procedure is applicable to samples with activities of 0.11 to 269 mmol/ml/h. Intrasample coefficient of variation for mouse serum samples was 1.7% (n = 12), while intersample coefficient of variation was 8.0% (n = 5). The mean +/- SE serum cholinesterase activity found for controls and mice treated with diisopropyl phosphofluoridate (6.3 mg/kg, ip, 24 h prior) was 158.7 +/- 5.7 mumol/ml/h and 36.6 +/- 3.1 mumol/ml/h, respectively (P less than 0.001). 相似文献
11.
Davies BJ Herbert MK Coller JK Somogyi AA Milne RW Sallustio BC 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,843(2):302-309
The use of perhexiline (PHX) is limited by hepatic and neurological toxicity associated with elevated concentrations in plasma that are the result of polymorphism of the cytochrome P450 2D6 isoform (CYP2D6). PHX is cleared by hepatic oxidation that produces three 4-monohydroxy metabolites: cis-OH-PHX, trans1-OH-PHX and trans2-OH-PHX. The current study describes an HPLC-fluorescent method utilising pre-column derivatization with dansyl chloride. Following derivatization, the metabolites were resolved on a C18 column with a gradient elution using a mobile phase composed of methanol and water. The method described is suitable for the quantification of the metabolites in human plasma and urine following clinical doses and for kinetic studies using human liver microsomes. The method demonstrates sufficient sensitivity, accuracy and precision between 5.0 and 0.01, 50.0 and 0.2 and 1.0 and 0.005 mg/l in human plasma, urine and liver microsomes, respectively, with intra-assay coefficients of variation and bias <15%, except at the lowest limit of quantification (<20%). The inter-assay coefficients of variation and bias were <15%. The application of this method to plasma and urine samples of five CYP2D6 extensive metaboliser (EM) patients at steady state with respect to PHX dosing determined that the mean (+/-S.D.) renal clearances of trans1-OH-PHX and cis-OH-PHX were 1.58+/-0.35 and 0.16+/-0.06l/h, respectively. The mean (+/-S.D.) dose recovered in urine as free and glucuronidated 4-monohydroxy PHX metabolites was 20.6+/-11.6%. 相似文献
12.
Radominska-Pandya A Pokrovskaya ID Xu J Little JM Jude AR Kurten RC Czernik PJ 《Archives of biochemistry and biophysics》2002,399(1):37-48
We have demonstrated the subcellular localization of the human UDP-glucuronosyltransferases (UGTs), UGT2B7 and UGT1A6, in endoplasmic reticulum (ER) and nuclear membrane from human hepatocytes and cell lines, by in situ immunostaining and Western blot. Double immunostaining for UGT2B7 and calnexin, an ER resident protein, showed that UGT2B7 was equally present in ER and nuclear membrane whereas calnexin was present almost exclusively in ER. Immunogold labeling of HK293 cells expressing UGT2B7 established the presence of UGT2B7 in both nuclear membranes. Enzymatic assays with UGT2B7 substrates confirmed the presence of functional UGT2B7 protein in ER, whole nuclei, and both outer and inner nuclear membranes. This study has identified, for the first time, the presence of UGT2B7 and UGT1A6 in the nucleus and of UGT2B7 in the inner and outer nuclear membranes. This localization may play an important functional role within nuclei: protection from toxic compounds and/or control of steady-state concentrations of nuclear receptor ligands. 相似文献
13.
M. Franklin J. Odontiadis 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,679(1-2)
Naloxone, the analyte and the internal standard, sumatriptan, are extracted from plasma using solid-phase extraction columns. Chromatography and detection are performed using isocratic reversed-phase high-performance liquid chromatography (HPLC) with coulometric end-point detection. The standard curve was linear over the range 0–50 ng/ml of naloxone in plasma. The reproducibility, the coefficient of variation (C.V.) of the method over the range of the standard curve was 6.2–11.2%. The recovery averaged 90.4±8.9%. A plasma profile following i.v. administration of naloxone in one normal healthy volunteer is presented. 相似文献
14.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,762(1):51-58
A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the hypoglycemic agent metformin is described. Acidified samples of plasma were deproteinated with acetonitrile, washed with dichloromethane and the resulting supernatant injected. Chromatography was performed at 40°C by pumping a mobile phase of acetonitrile (250 ml) in pH 7, 0.03 M diammonium hydrogen phosphate buffer (750 ml) at a flow-rate of 1 ml/min through a silica column. Metformin and the internal standard (atenolol) were detected at 240 nm and were eluted 7.8 and 6.8 min, respectively, after injection. No endogenous substances were found to interfere. Calibration curves were linear (r>0.999) from 10 to 2000 ng/ml. The absolute recovery of both metformin and atenolol was greater than 76%. The detection limit and limit of quantitation were 2.5 and 10 ng/ml, respectively. The intra- and inter-day precision (C.V.) was 12%, or less, and the accuracy was within 6.2% of the nominal concentration. This method is suitable for clinical investigation and monitoring metformin concentration. 相似文献
15.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,676(1):147-152
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifampin in human plasma. Rifampin and sulindac (internal standard) are extracted from human plasma using a C2 Bond Elut extraction column. A 100-μl volume of 0.1 M HCl is added to the plasma before extraction to increase the retenction of the compounds on the extraction column. Methanol (1 ml) is used to elute the compounds and 0.5 ml of 3 mg/ml ascorbic acid in water is added to the final eluate to reduce the oxidation of rifampin. Separation is achieved by reversed-phase chromatography on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate-acetonitrile (55:45, v/v). Detection is by ultraviolet absorbance at 340 nm. The retention times of rifampin and internal standard are approximately 4.4 and 7.8 min, respectively. The assay is linear in concentration ranges of 50 to 35 000 ng/ml. The quantitation limit is 50 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility. 相似文献
16.
Kazutake Shimada Makoto Tanaka Toshio Nambara Yutaka Imai Keishi Abe Kaoru Yoshinaga 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1982,227(2):445-451
A new method for quantitation of captopril in human blood is described. Captopril was derivatized with N-(4-dimethylaminophenyl)maleimide into the electrochemically active adduct. The derivative was separated and determined by high-performance liquid chromatography with an electrochemical detector on a reversed-phase column. The proposed method was satisfactory for determination of captopril in whole blood with respect to accuracy and precision. The detection limit of captopril thereby obtained was 10 ng/ml. The blood levels of captopril in patients orally given an officinal dose were measured by the present method. 相似文献
17.
Sevgi Tatar Sedef Atmaca 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,758(2):305-310
A sensitive and specific HPLC method has been developed for the assay of amlodipine in human plasma. The assay involves derivatization with 4-chloro-7-nitrobenzofurazan (NBD-Cl), solid-phase extraction on a silica column and isocratic reversed-phase chromatography with fluorescence detection. Nortriptyline hydrochloride was used as an internal standard. The assay was linear over the concentration range of 0.25–18.00 ng/ml. Both of the within-day and day-to-day reproducibility and accuracy were less than 11.80% and 12.00%, respectively. The plasma profile following a single administration of 10 mg amlodipine to a healthy volunteer was presented. 相似文献
18.
19.
M. A. Raggi C. Sabbioni G. Casamenti G. Gerra N. Calonghi L. Masotti 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,730(2):3854-211
In the present study, assays were improved for the determination of catecholamines in human plasma. High-performance liquid chromatography with electrochemical detection was employed for quantitative analysis. The influence of various parameters on chromatographic performance, such as the composition and the pH of the mobile phase, and the detection potential, was investigated. An accurate solid-phase extraction procedure, after catecholamine complexation with diphenylborate, was developed. The efficiency yield for all catecholamines was in the range 92–98%. Relative standard deviation values for repeatability and for intermediate precision were less than 2% and 3%, respectively, for all three analytes. 相似文献
20.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,676(1):125-130
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility. 相似文献