首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
A quantitative gas chromatographic—mass spectrometric assay was developed for the determination of phenelzine in human plasma. Phenelzine, in aqueous solution or in plasma reacts at room temperature with pentafluorobenzaldehyde to form quantitatively a hydrazone derivative. The derivative has good gas chromatographic characteristics. The assay utilizes selected ion monitoring in a gas chromatographic effluent, the molecular ion generated by electron impact ionization of phenelzine derivative. Phenelzine-d7 was synthesized and used as an internal standard. The assay can measure 2 ng/ml of the drug with about 10% precision.The method was used for the determination of steady state levels of phenelzine in the plasma of patients taking a therapeutic dose of the drug.  相似文献   

2.
Furosemide (FD; Lasix®) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-μl sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6–14.0 mg), with a mean urine volume of 3024 ml (range 2620–3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analyses to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography—mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.  相似文献   

3.
A new simple and sensitive assay has been developed for the quantitative measurement of BN50730 at the picomole level in human plasma and urine. The drug and the internal standard (BN50765) were measured by combined liquid chromatography—negative chemical ionization mass spectrometry with methane as the reagent gas. A simple solid—liquid extraction procedure was used to isolate BN50730 from complex biological matrices. Mild operating conditions were required to assay the parent drug with a particle beam interface from Hewlett-Packard. The mass spectrometer was tuned to monitor the intense ion m/z 333, which was generated in the ion source by a dissociative capture process. This assay was performed with 1 ml of plasma or 0.1 ml of urine, and the quantification limit of the method was statistically calculated as 1 ng ml−1. The very low relative standard deviation and mean percentage of error calculated during the different within-day or between-day repeatability assays clearly demonstrate the ruggedness of the technique for the routine determination of BN50730 in the biological fluids. Some preliminary results on the pharmacokinetics of the drug are presented to illustrate the applicability of this new powerful LC—MS method.  相似文献   

4.
A simple and highly sensitive method has been developed for the determination in plasma of ciprostene, 9β-methyl-6α-carbaprostaglandin I2, using gas chromatography—mass spectrometry following solid-phase extraction on an immobilized antibody column. The anti-ciprostene antibody obtained from rabbit serum was coupled to an agarose support matrix, and the immobilized antibody thus prepared was used as an extraction phase for sample clean-up. The extracted drug was treated with pentafluorobenzyl bromide followed by bis(trimethylsilyl)trifluoroacetamide. The derivative was quantitatively analysed by negative-ion chemical ionization gas chromatography—mass spectrometry. The lower limit of quantitation was 50 pg/ml when 1 ml of human plasma was used. The plasma concentration of ciprostene in a dog treated with ciprostene at 2.5 μg/kg was determined successfully by this method.  相似文献   

5.
A fully validated gas chromatographic–tandem mass spectrometric (GC–MS–MS) method is described for the accurate determination of acetylsalicylic acid (ASA) in human plasma after a single low-dose oral administration of aspirin or guaimesal, an ASA releasing prodrug. ASA and the newly prepared O-[2H3]-acetylsalicylic acid (d3-ASA) used as internal standard were determined in 100-μl aliquots of plasma by extractive pentafluorobenzyl (PFB) esterification using PFB bromide and tetrabutylammoniumhydrogen sulphate as the esterifying and ion-pairing agent, respectively, and by GC–MS–MS analysis in the negative-ion chemical ionization mode. The overall relative standard deviations were below 8% for ASA levels in the range 0–1 μg/ml plasma. Mean accuracy was 3.8% for ASA levels within the range 0–100 ng/ml. The limit of quantitation of the method was determined as 200 pg/ml ASA at an accuracy of 5.5% and a precision of 15.2%. The limit of detection was determined as 546 amol of ASA at a signal-to-noise ratio of 10:1.  相似文献   

6.
The urine concentrations of free salsolinol were determined in six healthy volunteers, using a gas chromatographic—mass spectrometric method with electron-capture negative-ion chemical ionization after derivatization with pentafluoropropionyl anhydride. The sensitivity of this method allows the quantification of salsolinol concentrations of 0.55 pmol/ml. The synthesis of [2H4]salsolinol from dopamine and [2H4]acetaldehyde via a Pictet—Spengler condensation is described; [2H4]salsolinol was used as the internal standard for salsolinol quantification. The urine concentrations of free salsolinol ranged from ca. 1 to 6 pmol/ml.  相似文献   

7.
An electron-capture negative-ion chemical ionization gas chromatographic—mass spectrometric assay for mefloquine, an antimalarial drug used in the treatment of drug-resistant Plasmodium falciparum malaria, is described. The method, developed in support of bioavailability studies involving the co-administration of different tableted formulations of the drug and an aqueous solution of its 13C3-labeled analog, enables quantification of both dosage forms. Quantitative analysis of extracted plasma samples was performed on the O-tert.-butyldimethylsilyl (t-BDMS) derivative of the drug by selected-ion monitoring, using a VG Trio 2000 quadrupole mass spectrometer and monitoring the [M — t-BDMSOH]−√ ions of the analytes. The method, incorporating [2H6]mefloquine as an internal standard, demonstrated good accuracy and precision over the 1–200 ng ml−1 range, with correlation coefficients greater than 0.990 for all standard curves and a detection level of 50 fg on-column. Replicate analysis of plasma samples over a 90-day period exhibited a mean intra-day and inter-day variation of less than 4.5% and 5.5%, respectively. The high stability and sensitivity of the assay, combined with the inherent selectivity of mass spectrometric detection, make the method well-suited for such studies.  相似文献   

8.
A rapid, selective and sensitive HPLC–tandem mass spectrometry method was developed and validated for simultaneous determination of flupirtine and its active metabolite D-13223 in human plasma. The analytes and internal standard diphenhydramine were extracted from plasma samples by liquid–liquid extraction, and chromatographed on a C18 column. The mobile phase consisted of acetonitrile–water–formic acid (60:40:1, v/v/v), at a flow rate of 0.5 ml/min. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method has a limit of quantitation of 10 ng/ml for flupirtine and 2 ng/ml for D-13223, using 0.5-ml plasma sample. The linear calibration curves were obtained in the concentration range of 10.0–1500.0 ng/ml for flupirtine and 2.0–300.0 ng/ml for D-13223. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples was less than 7.2% for flupirtine and D-13223. The accuracy as determined from QC samples was less than 5% for the analytes. The overall extraction recoveries of flupirtine and D-13223 were determined to be about 66% and 78% on average, respectively. The method was applied for the evaluation of the pharmacokinetics of flupirtine and active metabolite D-13223 in volunteers following peroral administration.  相似文献   

9.
A sensitive and specific method for the determination of the aza alkyl lysophospholipid (AALP) 3-methoxy-2-N,N-methyloctadecylaminopropyloxyphosphorylcholine (I) in rat plasma is described. The target molecule was analyzed by high-performance liquid chromatography (HPLC)—mass spectrometry (MS) after one single liquid—liquid extraction with chloroform—methanol (2:1, v/v). 1,2-Didecanoyl-sn-glycero-3-phosphocholine was used as internal standard. HPLC was carried out using a polymeric reversed-phase column; the coupling to the mass spectrometer was a particle beam (PB) interface, and the ionization method was electron impact (EI). This simple and rugged method permits the measurement of I in rat plasma in the range of 25 ng/ml–5 μg/ml with good accuracy and precision and is used in pharmacokinetic studies.  相似文献   

10.
The dioxopiperazine metabolites of quinapril in plasma and urine were extracted with hexane—dichloroethane (1:1) under acidic conditions. Following derivatization with pentafluorobenzyl bromide and purification of the desired reaction products using a column packed with silica gel, the metabolites were analysed separately by capillary column gas chromatography—electron-impact mass spectrometry with selected-ion monitoring. The limits of quantitation for the metabolites were 0.2 ng/ml in plasma and 1 ng/ml in urine. The limits of detection were 0.1 ng/ml in plasma and 0.5 ng/ml in urine, at a signal-to-noise ratio of > 3 and > 5, respectively. The proposed method is applicable to pharmacokinetic studies.  相似文献   

11.
An analytical method has been developed for the simultaneous determination of a novel orally active angiotensin-converting enzyme inhibitor (CGS 16617) and a stable isotope-labeled analog. Both compounds are isolated from human plasma using an ion-exchange column, derivatized with pentafluoropropionic anhydride and pentafluoropropanol, and analyzed by gas chromatography/mass spectrometry. After splitless injection on a methyl-silicon column, the compound is detected using negative ion chemical ionization with nitrous oxide as a reagent gas. CGS 16617 labeled with four deuteriums and two 13C is used as an internal standard. The accuracy and precision of the method, expressed as the overall mean +/- SD recovery obtained from two sets of 36 quality-control samples used during a clinical study (concentration range 0.2-100 ng ml-1 plasma), was 96.1 +/- 16.2% for unlabeled drug and 97.6 +/- 14.4% for the D4-labeled drug (concentration range 0.2-100 ng ml-1 plasma). The limit of quantification using 1 ml plasma is 0.2 ng ml-1 for both labeled and unlabeled drug.  相似文献   

12.
A method is described for measuring midazolam, a new anesthesia induction agent and hypnotic, and its hydroxymethyl and desmethyl metabolites in human plasma. Deuterated analogues of each compound are added to plasma as internal standards. The compounds are extracted from plasma with benzene containing 20% 1, 2-dichloroethane and after removal of the extracting solvent are dissolved in a solution of bis-(trimethylsilyl)acetamide and acetonitrile. An aliquot of this solution is analyzed by gas chromatography—mass spectrometry with the mass spectrometer set to monitor in the gas chromatographic effluent the M$$$ ions of drug, metabolites and internal standards generated by methane electron-capture negative chemical ionization. For all three compounds, the limit of quantitation is 1 ng ml−1, and the precision (relative standard deviation) at a concentration of 5 ng ml−1 is less than 6%. Measurable amounts of the hydroxymethyl, but not the desmethyl, metabolite of midazolam could be found in the plasma of humans given either an intravenous or an oral dose of midazolam maleate.  相似文献   

13.
A gas chromatographic—mass fragmentographic method was developed for the determination of homopantothenic acid in plasma. Acidified plasma was deproteinized by extraction with chloroform and subsequently the aqueous layer was extracted with ethyl acetate. The organic layer containing homopantothenic acid was reduced to dryness, and the resulting residue was redissolved in N,O-bis(trimethylsilyl)trifluoroacetamide—pyridine solution to allow trimethylsilylation. Aliquots of this solution were injected into the gas chromatograph—mass spectrometer and analyzed by the selected ion monitoring method using l-ascorbic acid as an internal standard. The detection limit for homopantothenic acid was 5 ng/ml of plasma.A precise and sensitive assay for the determination of homopantothenic acid in plasma was established.  相似文献   

14.
A specific high-performance liquid chromatographic-atmospheric pressure chemical ionization tandem mass spectrometric assay for the quantitative determination of β-tigogenin cellobioside in human serum is described. Serum cleanup and acetylation of the analyte were required to achieve the desired lower limit of quantification, 10 ng/ml. The precision of the assay was better than 13% over a serum concentration range of 10–500 ng/ml.  相似文献   

15.
A gas chromatographic-negative ion chemical ionization mass spectrometric (GC-NCI-MS) method for the quantitative analysis of clonazepam in human plasma is described. Clonazepam (Mr = 315) was derivatized by N,O-bis-(trimethylsilyl)trifluoroacetamide with 1% trimethylchlorosilane. A pre-conditioning procedure involving injection of a silyl-8 and ethyl acetate extraction solution from plasma reduces the interaction between clonazepam-TMS and the analytical system. The routine limit of quantification was set to be 0.25 ng/ml with an injection volume of 2 μl and a sample volume of 1 ml. The signal-to-noise ratio was greater than five. The detection limit for clonazepam can reach 0.1 ng/ml. The isotope clonazepam-d5 was used as the internal standard.  相似文献   

16.
A stable-isotope based gas chromatography–tandem mass spectrometry–negative ion chemical ionization method was developed for the determination of norepinephrine (NE) levels in small volumes (25–100 μl) of plasma. NE was stabilized in plasma by the addition of semicarbazide and spiked with deuterium-labeled norepinephrine internal standard. The analytes were isolated from the plasma by solid-phase extraction using phenylboronic acid columns and derivatized using pentafluoropropionic anhydride. The derivatized analytes were chromatographed on a capillary column and detected by tandem mass spectrometry with negative ion chemical ionization. Unparalleled sensitivity and selectivity were obtained using this detection scheme, allowing the unambiguous analysis of trace levels of NE in small-volume plasma samples. Linear standard curves were obtained for NE over a mass range from 1 to 200 pg per sample. The method had a limit of quantitation of 10 pg NE/ml plasma when using a 100-μl sample aliquot (1 pg/sample). Accuracy for the analysis of plasma samples spiked with 10 to 200 pg NE/ml typically ranged from 100±10%, with RSD values of less than 10%. The methodology was applied to determine the effect of clonidine on plasma NE levels in conscious spontaneously hypertensive rats. Administration of clonidine (30 μg/kg) produced an 80% reduction in plasma NE accompanied by a 30% reduction in heart and mean arterial pressure that persisted >90 min after drug administration. The ability to take multiple samples from individual rats allowed the time course for the effect of clonidine to be mapped out using only one group of animals.  相似文献   

17.
A rapid gas chromatography-mass spectrometric method for the determination of nalmefene in human plasma is described. The procedure involves protein precipitation, extraction with ethanol-chloroform mixture and derivatization with pentafluropropionic anhydride. The deuterated analog of nalmefene, 6beta-naltrexol-d(7), was used as the internal standard. Quantitation was achieved on a HP-1 column (12 mx0.2 mm I.D.) with negative chemical ionization (NCI) using methane:ammonia (95:5) as the reagent gas. The standard curves were fitted using a quadratic equation with the curve encompassing a range of 0.5 to 200 ng/ml, and the intra- and inter-assay variations for three different nalmefene levels were less than 10% throughout. The limit of quantitation was found to be 0.5 ng/ml. The method described is highly specific and reproducible, and could also be applied for the determination of naltrexone and 6beta-naltrexol. Application of the method to actual human plasma samples is demonstrated.  相似文献   

18.
A selective, sensitive, and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of aripiprazole and its active metabolite dehydroaripiprazole in human plasma has been developed using papaverine as internal standard (IS). LC-MS/MS analysis was carried out on a Finnigan LC-TSQ Quantum mass spectrometer using positive ion electrospray ionization (ESI+) and selected reaction monitoring (SRM). The assays for aripiprazole and dehydroaripiprazole were linear over the ranges of 0.1 to 600 ng/ml and 0.01 to 60 ng/ml, respectively. The average recoveries in plasma samples both were better than 85%. The intra- and interrun precision and accuracy values were found to be within the assay variability criteria limits according to the US Food and Drug Administration guidelines. The developed method was proved to be suitable for use in a clinical pharmacokinetic study after a single oral administration of a 5-mg aripiprazole tablet in healthy Chinese volunteers.  相似文献   

19.
A highly sensitive and selective liquid chromatography–atmospheric pressure chemical ionization tandem mass spectrometry assay was developed and validated for simultaneous determination of epimeric budesonide (BUD) and fluticasone propionate (FP) in plasma. The drugs were isolated from human plasma using C18 solid-phase extraction cartridges, and epimeric BUD was acetylated with a mixture of 12.5% acetic anhydride and 12.5% triethylamine in acetonitrile to form the 21-acetyl derivatives following the solid-phase extraction. Deuterium-labelled BUD acetate with an isotopic purity >99% was synthesized and used as the internal standard. The assay was linear over the ranges 0.05–10.0 ng/ml for epimeric BUD, and 0.02–4.0 ng/ml for FP. The inter- and intra-day relative standard deviations were <14.3% in the assay concentration range.  相似文献   

20.
A sensitive and specific analytical method for a potent antitumor agent, TZT-1027, in plasma has been developed using liquid chromatography–mass spectrometry (LC–MS) with [2H4]TZT-1027 as an internal standard (I.S.). A plasma sample was purified by solid-phase extraction on a C18 cartridge, followed by solvent extraction with diethyl ether. The extract was then injected into the LC–MS system. Chromatography was carried out on a C18 reversed-phase column using acetonitrile–0.05% trifluoroacetic acid (TFA) (55:45) as a mobile phase. Mass spectrometric analysis was performed in atmospheric pressure chemical ionization (APCI) mode with positive ion detection, and the protonated molecular ions ([M+H]+) of TZT-1027 and I.S. were monitored to allow quantitation. The method was applied to the determination of TZT-1027 in human, monkey, dog, rat and mouse plasma. As far as the sample preparation was concerned, good recoveries (73.5–99.1%) were obtained. The calibration curves were linear over the range of 0.25–100 ng per 1 ml of human, dog and rat plasma, per 0.5 ml of monkey plasma, and per 0.1 ml of mouse plasma. From the intra- and inter-day accuracy and precision, the present method satisfies the accepted criteria for bioanalytical method validation. TZT-1027 was stable when stored below −15°C for 6 months in human plasma and for 3 weeks in plasma from other species. TZT-1027 was also stable in plasma through at least three freeze–thaw cycles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号