首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The measurement of dynamic scapular kinematics is complex due to the sliding nature of the scapula beneath the skin surface. The aim of the study was to clearly describe the acromion marker cluster (AMC) method of determining scapular kinematics when using a passive marker motion capture system, with consideration for the sources of error which could affect the validity and reliability of measurements. The AMC method involves placing a cluster of markers over the posterior acromion, and through calibration of anatomical landmarks with respect to the marker cluster it is possible to obtain valid measurements of scapular kinematics. The reliability of the method was examined between two days in a group of 15 healthy individuals (aged 19-38 years, eight males) as they performed arm elevation, to 120°, and lowering in the frontal, scapular and sagittal planes. Results showed that between-day reliability was good for upward scapular rotation (Coefficient of Multiple Correlation; CMC = 0.92) and posterior tilt (CMC = 0.70) but fair for internal rotation (CMC = 0.53) during the arm elevation phase. The waveform error was lower for upward rotation (2.7° to 4.4°) and posterior tilt (1.3° to 2.8°), compared to internal rotation (5.4° to 7.3°). The reliability during the lowering phase was comparable to results observed during the elevation phase. If the protocol outlined in this study is adhered to, the AMC provides a reliable measurement of upward rotation and posterior tilt during the elevation and lowering phases of arm movement.  相似文献   

2.
The validation of two noninvasive methods for measuring the dynamic three-dimensional kinematics of the human scapula with a magnetic tracking device is presented. One method consists of simply fixing a sensor directly to the acromion and the other consists of mounting a sensor to an adjustable plastic jig that fits over the scapular spine and acromion. The concurrent validity of both methods was assessed separately by comparison with data collected simultaneously from an invasive approach in which pins were drilled directly into the scapula. The differences between bone and skin based measurements represents an estimation of skin motion artifact. The average motion pattern of each surface method was similar to that measured by the invasive technique, especially below 120 degrees of elevation. These results indicate that with careful consideration, both methods may offer reasonably accurate representations of scapular motion that may be used to study shoulder pathologies and help develop computational models.  相似文献   

3.
IntroductionThe acromion marker cluster (AMC) is a non-invasive scapular motion tracking method. However, it lacks testing in clinical populations, where unique challenges may present. This investigation resolved the utility of the AMC approach in a compromised clinical population.MethodsThe upper body of breast cancer survivors (BCS) and controls were tracked via motion capture and scapular landmarks palpated and recorded using a digitizer at static neutral to maximum elevation postures. The AMC tracked the scapula during dynamic maximum arm abduction. Both single (SC) and double calibration (DC) methods were applied to calculate scapular angles. The influences of calibration method, elevation, and group on mean and absolute error with two-way fixed ANOVAs with interactions (p < 0.05). Root mean square errors (RMSE) were calculated and compared.ResultsDC improved AMC estimation of palpated scapular orientation over SC, especially at higher arm elevations; RMSE averaged 11° higher for SC than DC at maximum elevation, but the methods were only 2.2° different at 90° elevation. DC of the AMC yielded mean error values of ∼5–10°. These approximate errors reported for AMC with young, lean adults.ConclusionsThe AMC with DC is a non-invasive method with acceptable error for measuring scapular motion of BCS and age-matched controls.  相似文献   

4.
The most recent non-invasive methods for the recording of scapular motion are based on an acromion marker (AM) set and a single calibration (SC) of the scapula in a resting position. However, this method fails to accurately measure scapular kinematics above 90° of arm elevation, due to soft tissue artifacts of the skin and muscles covering the acromion. The aim of this study was to evaluate the accuracy, and inter-trial and inter-session repeatability of a double calibration method (DC) in comparison with SC. The SC and DC data were measured with an optoelectronic system during arm flexion and abduction at different angles of elevation (0-180°). They were compared with palpation of the scapula using a scapula locator. DC data was not significantly different from palpation for 5/6 axes of rotation tested (Y, X, and Z in abduction and flexion), where as SC showed significant differences for 5/6 axes. The root mean square errors ranged from 2.96° to 4.48° for DC and from 6° to 9.19° for SC. The inter-trial repeatability was good to excellent for SC and DC. The inter-session repeatability was moderate to excellent for SC and moderate to good for DC. Coupling AM and DC is an easy-to-use method, which yields accurate and reliable measurements of scapular kinematics for the complete range of arm motion. It can be applied to the measurement of shoulder motion in many fields (sports, orthopaedics, and rehabilitation), especially when large ranges of arm motion are required.  相似文献   

5.
The aim of this study was to establish the optimal methodology for skin-fixed measurement of the scapula during dynamic movement. This was achieved by comparing an optimally positioned Scapula Tracker device (ST) to a previously described palpation device, taken as the true measure of scapular kinematics. These measurements were compared across a range of calibration positions, including the use of multiple calibration positions for a single movement, in order to establish an optimal calibration approach. Ten subjects' scapular motion was measured using this ST and a previously described Acromial Method (AM). The two datasets were compared at a standard, an optimal and a 'multiple' calibration position, thus allowing a direct comparison between two common skin-fixed methods to track the bony kinematics of the scapula across different calibration positions. A comparison was also made with a bone-fixed technique from the literature. At both the standard and optimal calibration positions the ST was shown to be the more accurate measure of internal rotation and posterior tilt, particularly above 100° of humerothoracic elevation. The ST errors were found to be acceptable in relation to clinically important levels. Calibration positions have been shown to have a significant effect on the errors of both skin-fixed measurement techniques and therefore the importance of correct calibration is highlighted. It has thus been shown that a ST can be used to accurately quantify scapular motion when appropriately calibrated for the range of motion being measured.  相似文献   

6.
Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p < 0.01). Method of measurement interacted with axial rotation in anterior/posterior tilt and protraction/retraction (p < 0.01). The AMC had strong agreement with the reference stylus than the locator for the majority of humeral elevations, planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations.  相似文献   

7.
The aim of this study is to determine the errors of scapular localisation due to skin relative to bone motion with an optoelectronic tracking system. We compared three-dimensional (3D) scapular positions obtained with skin markers to those obtained through palpation of three scapular anatomical landmarks. The scapular kinematics of nine subjects were collected. Static positions of the scapula were recorded with the right arm elevated at 0°, 40°, 80°, 120° and 160° in the sagittal plane. Palpation and subsequent digitisation of anatomical landmarks on scapula and thorax were done at the same positions. Scapular 3D orientation was also computed during 10 repeated movements of arm elevation between 0° and 180°. Significant differences in scapular kinematics were seen between static positions and palpation when considering anterior/posterior tilt and upward/downward rotation at angles over 120° of humeral elevation and only at 120° for internal/external rotation. There was no significant difference between positions computed during static positions and during the movement for the three scapular orientations. A rotation correction model is presented in order to reduce the errors between static position and palpation measurement.  相似文献   

8.
The shoulder is complex and comprised of many moving parts. Accurately measuring shoulder rhythm is difficult. To classify shoulder rhythm and identify pathological movement, static measures have been the preferred method. However, dynamic measures are also used and can be less burdensome to obtain. The purpose of this paper was to determine how closely dynamic measures represent static measures using the same acromion marker cluster scapular tracking technique. Five shoulder angles were assessed for 24 participants using dynamic and static tracking techniques during humeral elevation in three planes (frontal, scapular, sagittal). ANOVAs were used to identify where significant differences existed for the factors of plane, elevation angle, and tracking technique (static, dynamic raising, dynamic lowering). All factors were significantly different for all shoulder angles (p < 0.001), except for elevation plane in scapulothoracic protraction/retraction (p = 0.955). Tracking techniques were influential (p < 0.001), but the grouped mean differences fell below a clinically relevant 5° benchmark. There was large variation in mean differences of the techniques across individuals. While population averages are similar, individual static and dynamic shoulder assessments may be different. Caution should be taken when dynamic shoulder assessments are performed on individuals, as they may not reflect those obtained in static scapular motion tracking.  相似文献   

9.
Scapula motion is significant for support of the arm and stability of the shoulder. The effect of the humeral elevation on scapular kinematics has been well investigated for normal subjects, but there are limited published studies investigating adaptations after shoulder arthroplasty. Scapula kinematics was measured on 10 shoulders (eight subjects) with a reverse total joint replacement. The measurements were performed using an instrumented palpating technique. Every subject performed three simple tasks: abduction, elevation in scapula plane and forward flexion. Results indicate that, lateral scapula rotation was significantly increased (average of 24.42% over the normal rhythm) but the change was variable. Despite the variability, there is a clear trend correlating humeral performance with increased rotation (R2 0.829). There is clearly an adaptation in lateral scapula rotation in patients with shoulder joint replacement. The reason for this is unclear and may be related to joint pathology or to muscle adaptation following arthroplasty.  相似文献   

10.
The aim of this study was to investigate the applicability of the moiré fringe projection technique (MFPT) to quantify the scapular motions relative to the thorax. This system was composed of a LCD projector, a digital photographic camera, and a microcomputer. To automatically obtain the scapular profiles, the phase shifting method was combined with the MFPT. Four fringes were projected on the scapula and four on the reference planes. By the simple subtraction of the reference values from the scapular phase maps, the map due to the moiré fringes could be digitally obtained. After the phase decoding, the tridimensional (3D) profiles were obtained without prior information about the samples and the calculations of the scapular kinematics were carried out using dedicated software. On average, the movements of lateral rotation ranged from ?1.8±6.1° to ?26.5±3.5°; the protraction from 28.4±4.7° to 27.7±6.8°, and the posterior tilt from ?6.4±7.8° to ?21.7±6.1°, during the arm elevation in the scapular plane performed by six healthy subjects. For the test–retest reliability, the intra-class correlation coefficients ranged from 0.92 to 0.997 and the maximum estimated error was 0.8%. The MFPT allowed the scapular 3D measurements to be obtained in a digital and non-invasive manner. The main advantages compared with other existing systems were its ease in implementation, the use of standard optical components, and its possible clinical applications.  相似文献   

11.
We aimed to describe 3D scapular kinematics and scapulohumeral rhythm (SHR) in glenohumeral (GH) osteoarthritis shoulders compared to unaffected shoulders and to compare the abnormal scapular kinematic schema for GH osteoarthritis with that for frozen shoulder. Thirty-two patients with stiff shoulder (16 with GH osteoarthritis and 16 with frozen shoulder) performed maximal arm elevation in two planes, sagittal and frontal. Scapular rotations and humeral elevation of the affected and unaffected shoulders were measured by the Polhemus Fastrak electromagnetic system. Patients with GH osteoarthritis were older, had longer disease duration (p<0.001) and less restricted humeral elevation in the frontal plane (p=0.01). Protraction was significantly lower for the affected shoulders except for arm elevation in the frontal plane in the GH osteoarthritis group. Furthermore, protraction was lower with frozen shoulder than GH osteoarthritis during arm elevation in the frontal plane. Scapular lateral rotation and SHR were significantly higher for the affected shoulders in both groups whatever the plane of elevation. SHR showed a fair to moderate negative correlation with maximal humeral elevation in both groups and appears to be higher with frozen shoulder than GH osteoarthritis. In addition, SHR of the affected shoulder showed a fair to moderate correlation with disease duration only with GH osteoarthritis. Scapular tilt did not differ between affected and unaffected sides and was not influenced by type of disease. In conclusion, the increased scapular lateral rotation described in frozen shoulder is also observed in GH osteoarthritis. SHR of the affected shoulder is inversely related to severity of limitation of shoulder range of motion, which suggests a compensatory pattern.  相似文献   

12.
Optoelectronic tracking systems are rarely used in 3D studies examining shoulder movements including the scapula. Among the reasons is the important slippage of skin markers with respect to scapula. Methods using electromagnetic tracking devices are validated and frequently applied. Thus, the aim of this study was to develop a new method for in vivo optoelectronic scapular capture dealing with the accepted accuracy issues of validated methods.

Eleven arm positions in three anatomical planes were examined using five subjects in static mode. The method was based on local optimisation, and recalculation procedures were made using a set of five scapular surface markers.

The scapular rotations derived from the recalculation-based method yielded RMS errors comparable with the frequently used electromagnetic scapular methods (RMS up to 12.6° for 150° arm elevation). The results indicate that the present method can be used under careful considerations for 3D kinematical studies examining different shoulder movements.  相似文献   

13.
The aim of this study was to assess the reliability and validity of a modified two-dimensional electrical inclinometer to measure scapular upward rotation during static humeral elevation. Numerous techniques have been proposed to qualitatively and quantitatively measure upward rotation of the scapula. These techniques are limited by expense or an inability to be synchronized with other measurements, such as muscle activity and force output. For validity testing, static scapular upward rotation was measured separately with a digital protractor and electrical inclinometer while participants were at rest and 60°, 90° and 120° of humeral elevation in the scapular plane. For reliability testing, either 20 min before or 20 min after validity testing, participants performed the testing positions while measurements were taken with the electrical inclinometer only. Significant correlations existed between the modified electrical inclinometer and digital protractor at all four positions (r>0.996, p<0.001). The electrical inclinometer demonstrated good to excellent intra-rater reliability (ICC(3,1)>0.892, 95%CI: 0.785-0.988 and SEM<1.8°). These results support the use of the electrical inclinometer to measure scapular upward rotation. These findings provide clinicians and researchers with a practical instrument that can accurately measure scapular upward rotation in synchrony with other measurements, such as electromyography and isokinetic data.  相似文献   

14.
Conclusions about normal and pathologic shoulder motion are frequently made from studies using skin surface markers, yet accuracy of such sensors representing humeral motion is not well known. Nineteen subjects were investigated with flock of birds electromagnetic sensors attached to transcortical pins placed into the scapula and humerus, and a thermoplastic cuff secured on the arm. Subjects completed two repetitions of raising and lowering the arm in the sagittal, scapular and coronal planes, as well as shoulder internal and external rotation with the elbow at the side and abducted to 90°. Humeral motion was recorded simultaneously from surface and bone fixed sensors. The average magnitude of error was calculated for the surface and bone fixed measurements throughout the range of motion. ANOVA tested for differences across angles of elevation, raising and lowering, and differences in body mass index. For all five motions tested, the plane of elevation rotation average absolute error ranged from 0-2°, while the humeral elevation rotation average error ranged from 0-4°. The axial rotation average absolute error was much greater, ranging from 5° during elevation motions to approaching 30° at maximum excursion of internal/external rotation motions. Average absolute error was greater in subjects with body mass index greater than 25. Surface sensors are an accurate way of measuring humeral elevation rotations and plane of elevation rotations. Conversely, there is a large amount of average error for axial rotations when using a humeral cuff to measure glenohumeral internal/external rotation as the primary motion.  相似文献   

15.
Identification of scapular dyskinesis and evaluation of interventions depend on the ability to properly measure scapulothoracic (ST) motion. The most widely used measurement approach is the acromion marker cluster (AMC), which can yield large errors in extreme humeral elevation and can be inaccurate in children and patient populations. Recently, an individualized regression approach has been proposed as an alternative to the AMC. This technique utilizes the relationship between ST orientation, humerothoracic orientation and acromion process position derived from calibration positions to predict dynamic ST orientations from humerothoracic and acromion process measures during motion. These individualized regressions demonstrated promising results for healthy adults; however, this method had not yet been compared to the more conventional AMC. This study compared ST orientation estimates by the AMC and regression approaches to static ST angles determined by surface markers placed on palpated landmarks in typically developing adolescents performing functional tasks. Both approaches produced errors within the range reported in the literature for skin-based scapular measurement techniques. The performance of the regression approach suffered when applied to positions outside of the range of motion in the set of calibration positions. The AMC significantly underestimated ST internal rotation across all positions and overestimated posterior tilt in some positions. Overall, root mean square errors for the regression approach were smaller than the AMC for every position across all axes of ST motion. Accordingly, we recommend the regression approach as a suitable technique for measuring ST kinematics in functional motion.  相似文献   

16.
BackgroundThe scapula locator method has associated intra-observer and inter-observer errors caused by the dependency on the observer to locate the scapular landmarks. The potential effect of the pressures applied by the observer on the measured scapular kinematics when this method is used has also been overlooked so far. The aim of this study was to investigate the effect of using feedback on the pressures applied on the scapula using the locator on the intra-observer and inter-observer reliabilities of the method as well as on the kinematics obtained using this method.MethodsThree observers tracked the scapular motion of the dominant shoulder of each subject using the locator with no reference to pressure-feedback for three trials of bilateral elevation in the scapular plane and using the locator with pressure-feedback for three other trials. Variations between the measurements obtained were used to calculate the intra-observer errors and variations between the measurements obtained by the three observers for the same subject were used to calculate inter-observer errors. Repeated-measures ANOVA tests were used to look at differences between the two methods in terms of intra-observer and inter-observer errors and scapular kinematics.FindingsUsing pressure-feedback reduced the intra-observer errors but had no effect on the inter-observer errors. Different scapular kinematics was measured using the two methods.InterpretationsPressure-feedback improves the reliability of the scapula locator method. Differences in the scapular kinematics suggest that unregulated pressures have an effect on the physiological scapular motion.  相似文献   

17.
This study determined the ratio between glenohumeral and three-dimensional scapular motion during arm elevation and lowering in 91 individuals without shoulder pain. Scapular kinematics were assessed using an electromagnetic tracking device. Individuals performed 3 repetitions of elevation and lowering of the arm in the sagittal plane. Two-way ANOVAs (interval: 30–60°, 60–90°, 90–120° x phase: elevation and lowering) and paired t-tests were used for data analysis. For scapular internal/external rotation, lesser scapular internal rotation contribution was found during the 60–90° interval as compared to the 90–60° interval. Lesser scapular external rotation was identified in the 60–30° interval of arm lowering. The ratio was greater during arm elevation (1.89) compared to lowering (1.74) across the entire motion arc. For scapular upward rotation, greater upward rotation contribution was observed during arm elevation at the 30–60° interval, and less scapular downward rotation contribution in the final range of arm lowering. For scapular tilt, lesser scapular posterior tilt contribution during arm elevation was observed compared to arm lowering. The ratios between glenohumeral elevation/lowering and each individual scapulothoracic motion showed either differences between intervals and/or between elevation and lowering during specific intervals in healthy individuals.  相似文献   

18.
19.
A tendon transfer technique is proposed for the reconstruction of the paralyzed shoulders secondary to brachial plexus injury. This innovative technique does not require bone-to-bone or tendon to-bone fixation, and attempts to overcome other clinical limitations such as those due to insufficient length of donor muscle. The approach is referred to as the reflected long head biceps (RLHB) technique. The long head of biceps tendons is utilized as a bridging tendon graft. Two surgical alternatives, namely the through-deltoid (TD) pathway and the sub-deltoid (SD) pathway, were studied. The moment arms of the transferred tendons were assessed and reported. The TD technique yielded a larger moment than the SD technique. In the plane 30 degrees anterior to the scapular plane, the average moment arms were 3.8cm TD and 3.0cm SD at zero elevation. Such differences tended to further widen with increasing elevation. At 80 degrees elevation, the moment arms became 3.2cm TD and 1.2cm SD. The results supported the clinical feasibility of this RLHB tendon transfer approach.  相似文献   

20.
In order to create musculoskeletal models that can be scalable to different subject specificities the calculation of the exact locations of muscle attachment is required. For this purpose, a scaling method is presented that estimates muscle attachment locations in homologous segments using three bony landmarks per segment.A data-set of 17 muscles’ attachment lines from the shoulders of seven cadavers was used to assess the estimation quality of the scaling method. By knowing from the cadaver data the measured location of the muscles’ attachment lines it is possible to assess the quality of the estimated ones. The scaling results showed an overall mean RMSE for the scapula and humerus muscles of 7.6 and 11.1 mm, respectively. These results were then analyzed with an upper extremity model, in order to compute the influence of the RMSE in glenohumeral elevation muscle moment arms in the scapular plane.The results presented were considered to be satisfactory. Among other error contributors, the inter- and intra-subject variability should be further investigated, along with the sensitivity of a biomechanical model to these error variations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号