首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Acetylcholine sensor is successfully prepared by using immobilized enzymes, i.e., acetylcholinesterase and choline oxidase within separate hybrid mesoporous silica membranes with 12 nm pore diameter (F127M). The measurement was based on the detection of hydrogen peroxide produced by two sequential enzyme reactions. The determination range and the response time are 6.0–800 μM and within approximately 3 min, respectively. The sensor is very stable compared to free enzymes and 80% of the initial response was maintained even after storage for 80 days. These results show that two enzymes are successfully immobilized and well stabilized, and at the same time, two sequential enzyme reactions efficiently proceed within the separate hybrid mesoporous membranes. Further, we studied the possible detection of organophosphorus pesticides in terms of the inhibition of acetylcholinesterase activity, i.e., the decrease of current response, and demonstrated that the nanomolar concentrations of pesticide (DZN-oxon) can be detected with our sensor.  相似文献   

2.
We constructed a fusion protein (GOx-R5) consisting of R5 (a polypeptide component of silaffin) and glucose oxidase (GOx) that was expressed in Pichia pastoris. Silaffin proteins are responsible for the formation of a silica-based cell matrix of diatoms, and synthetic variants of the R5 protein can perform silicification in vitro[1]. GOx secreted by P. pastoris was self-immobilized (biosilicification) in a pH 5 citric buffer using 0.1 M tetramethoxysilane as a silica source. This self-entrapment property of GOx-R5 was used to immobilize GOx on a graphite rod electrode. An electric cell designed as a biosensor was prepared to monitor the glucose concentrations. The electric cell consisted of an Ag/AgCl reference electrode, a platinum counter electrode, and a working electrode modified with poly(neutral red) (PNR)/GOx/Nafion. Glucose oxidase was immobilized by fused protein on poly(neutral red) and covered by Nafion to protect diffusion to the solution. The morphology of the resulting composite PNR/GOx/Nafion material was analyzed by scanning electron microscopy (SEM). This amperometric transducer was characterized electrochemically using cyclic voltammetry and amperometry in the presence of glucose. An image produced by scanning electron microscopy supported the formation of a PNR/GOx complex and the current was increased to 1.58 μA cm−1 by adding 1 mM glucose at an applied potential of −0.5 V. The current was detected by way of PNR-reduced hydrogen peroxide, a product of the glucose oxidation by GOx. The detection limit was 0.67 mM (S/N = 3). The biosensor containing the graphite rod/PNR/GOx/Nafion detected glucose at various concentrations in mixed samples, which contained interfering molecules. In this study, we report the first expression of R5 fused to glucose oxidase in eukaryotic cells and demonstrate an application of self-entrapped GOx to a glucose biosensor.  相似文献   

3.
A highly sensitive and selective fluorescence method for the detection of acetylcholine (ACh) based on enzyme-generated hydrogen peroxide (H2O2) and a new boronate intramolecular charge transfer (ICT) fluorescence probe, 4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)-N-butyl-1,8-naphthalimide (BN), was developed. This strategy involves the reaction of ACh with acetylcholinesterase (AChE) to produce choline, which is further oxidized by choline oxidase (ChOx) to obtain betaine and H2O2. The enzyme-generated H2O2 reacts with BN and results in hydrolytic deprotection of BN to generate fluorescent product (4-hydroxyl-N-butyl-1,8-naphthalimide, ON). Two consecutive linear response ranges allow determining ACh in a wide concentration range with a low detection limit of 2.7 nM (signal/noise = 3). Compared with other fluorescent probes based on the mechanism of nonspecific oxidation, this reported boronate probe has the advantage of no interference from other biologically relevant reactive oxygen species (ROS) on the detection of ACh. This study provides a new method for the detection of ACh with high selectivity and sensitivity.  相似文献   

4.
A kind of nanocomposite with good dispersion in water was prepared through covalent adsorption of ferrocenecarboxaldehyde on multiwalled carbon nanotubes (MWNTs) for electrical communication between glucose oxidase (GOD) and electrode. The ferrocene-modified multiwalled carbon nanotube nanocomposites (MWNTs-Fc) could be conveniently cast on electrode surfaces. With the aid of chitosan, GOD was then immobilized on the nanostructure film to form a reagentless amperometric sensor for glucose determination. FTIR spectra and cyclic voltammetry were used to characterize the nanocomposites. The presence of both ferrocene as mediator of electron transfer and MWNTs as conductor enhanced greatly the enzymatic response to the oxidation of glucose. The novel biosensor exhibited a fast response toward glucose with a detection limit of 3.0 × 10−6 mol/L and the linear range extended up to 3.8 × 10−3 mol/L.  相似文献   

5.
A new amperometric biosensor for determining cholesterol based on deflavination of the enzyme cholesterol oxidase (ChOx) and subsequent reconstitution of the apo-protein with a complexed flavin adenine dinucleotide (FAD) monolayer is described. The charge transfer mediator pyrroquinoline quinone (PQQ) was covalently bound to a cystamine self-assembled monolayer (SAM) on an Au electrode. Boronic acid (BA) was then bound to PQQ using the carbodiimide procedure, and the BA ligand was complexed to the FAD molecules on which the apo-ChOx was subsequently reconstituted. The effective release of the FAD from the enzyme and the successful reconstitution were verified using molecular fluorescence and cyclic voltammetry. The optimal orientation of FAD toward the PQQ mediator and the distances between FAD and PQQ and between PQQ and electrode enhance the charge transfer, very high sensitivity (about 2,500 nAmM(-1)cm(-2)) being obtained for cholesterol determination. The biosensor is selective toward electroactive interferents (ascorbic acid and uric acid) and was tested in reference serum samples, demonstrating excellent accuracy (relative errors below 3% in all cases). The biosensor activity can be successfully regenerated in a simple process by successive reconstitution with batches of recently prepared apo-ChOx on the same immobilized Au/SAM-PQQ-BA-FAD monolayer (it was tested five times); the lifetime of the biosensor is about 45-60 days.  相似文献   

6.
A novel amperometric glucose biosensor based on the nine layers of multilayer films composed of multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide cross-linking reaction, respectively. A cleaned Pt electrode was immersed in PAA, MWCNTs, cysteamine and GNp, respectively, followed by the adsorption of GOD, assembling the one layer of multilayer films on the surface of Pt electrode (GOD/GNp/MWCNTs/Pt electrode). Repeating the above process could assemble different layers of multilayer films on the Pt electrode. PBS washing was applied at the end of each assembly deposition for dissociating the weak adsorption. Film assembling and characterization were studied by transmission electron microscopy and quartz crystal microbalance, and properties of the resulting glucose biosensors were measured by electrochemical measurements. The marked electrocatalytic activity of Pt electrode based on multilayer films toward H2O2 produced during GOD enzymatic reactions with glucose permitted effective low-potential amperometric measurement of glucose. Taking the sensitivity and selectivity into consideration, the applied potential of 0.35 V versus Ag/AgCl was chosen for the oxidation detection of H2O2 in this work. Among the resulting glucose biosensors, the biosensor based on nine layers of multilayer films was best. It showed a wide linear range of 0.1–10 mM glucose, with a remarkable sensitivity of 2.527 μA/mM, a detection limit of 6.7 μM estimated at a signal-to-noise ratio of 3 and fast response time (within 7 s). Moreover, it exhibited good reproducibility, long-term stability and the negligible interferences of ascorbic acid, uric acid and acetaminophen. The study can provide a feasible approach on developing new kinds of oxidase-based amperometric biosensors, and can be used as an illustration for constructing various hybrid structures.  相似文献   

7.
A destabilizing effect at pH 7 of sodium phosphate on several lipases immobilized via interfacial activation is shown in this work. This paper investigates if this destabilizing effect is extended to other inactivation conditions, immobilization protocols or even other immobilized enzymes (ficin, trypsin, β-galactosidase, β-glucosidase, laccase, glucose oxidase and catalase). As lipases, those from Candida antarctica (A and B), Candida rugosa and Rhizomucor miehei have been used. Results confirm the very negative effect of 100 mM sodium phosphate at pH 7.0 for the stability of all studied lipases immobilized on octyl agarose, while using glutaraldehyde-support the effect is smaller (still very significant using CALA) and in some cases the effect disappeared (e.g., using CALB). The change of the pH to 5.0 or 9.0, or the addition of 1 M NaCl reduced the negative effect of the phosphate in some instances (e.g., at pH 5.0, this negative effect is only relevant for CALB). Regarding the other enzymes, only the monomeric β-galactosidase from Aspergillus oryzae is strongly destabilized by the phosphate buffer. This way, the immobilization protocol and the inactivation conditions strongly modulate the negative effect of sodium phosphate on the stability of immobilized lipases, and this effect is not extended to other enzymes.  相似文献   

8.
A biosensor based on pyruvate oxidase (POX) enzyme was developed for the investigation of the effect of thiamine (vitamin B(1)) molecule on the activity of the enzyme. The biosensor was prepared with a chemical covalent immobilization method on the dissolved oxygen (DO) probe by using gelatin and cross-linking agent, glutaraldehyde. POX catalyzes the degradation of pyruvate to acetylphosphate, CO(2) and H(2)O(2) in the presence of phosphate and oxygen. Thiamine is an activator for POX enzyme and determination method of the biosensor was based on this effect of thiamine on the activity of the enzyme. The biosensor responses showed increases in the presence of thiamine. Increases in the biosensor responses were related to thiamine concentration. Thiamine determination is based on the assay of the differences on the biosensor responses on the oxygenmeter in the absence and the presence of thiamine. The biosensor response depend linearly on thiamine concentration between 0.025 and 0.5 microM with 2 min response time. In the optimization studies of the biosensor the most suitable enzyme amount was found as 2.5 U cm(-2) and also phosphate buffer (pH 7.0; 50 mM) and 35 degrees C were obtained as the optimum working conditions. In the characterization studies of the biosensor some parameters such as activator and interference effects of some substances on the biosensor response and reproducibility were carried out.  相似文献   

9.
In this work, we investigate the influence of crosslinkers on the operational and heat stability of immobilized enzymes on a silanized silicon surface. To this end, glucose-6-phosphate dehydrogenase (G6PDH), a model multimeric enzyme, was attached through bifunctional crosslinkers able to bind covalently the ?NH2 in the silane layer and of amine residues in the enzyme. Five bifunctional crosslinkers in the form of “X-spacer-X” were used, differing by the reactive functional groups (X = aldehyde: ?CHO, isothiocyanate: ?NCS, isocyanate: ?NCO), by the nature of the spacer chain (aromatic or aliphatic) or by the geometry (bifunctional groups positioned in meta- or para- on an aromatic ring). A thermostability enhancement has been obtained for enzymes immobilized using 1,4-phenylene diisothiocyanate (PDC) and 1,4-phenylene diisocyanate (DIC). Moreover, using the latter crosslinker, activity was the mostly preserved upon successive uses, thus giving the best operational stability achieved. Changing the geometry of the cross-linker, i.e., 1,4- as compared to 1,3-phenylene diisothiocyanate (PDC and MDC, respectively), has a crucial effect on operational and thermal stabilities. Indeed, among all used crosslinkers, the most important loss was observed for MDC (residual activity after 6 times use is ~16%). Using dialdehyde crosslinkers: glutaraldehyde (GA) and terephtalaldehyde (TE), activity was significantly less well preserved than with DIC and PDC (for GA and TE, a loss of about 50% at 30 °C against no loss for PDC and DIC).These effects can be explained by a multipoint attachment model, in which a higher number of anchoring points stabilizes the three-dimensional structure and especially the binding of the two subunits in the active dimer, at the expense of a greater rigidity which is detrimental to the absolute activity. The differences observed with the crosslinkers are mainly due to steric hindrance at the interface which seems to be greatly influenced by the structure and the reactivity of the linkers.  相似文献   

10.
This paper aimed at showing the interest of the composite material based on layered double hydroxides (LDHs) and chitosan (CHT) as suitable host matrix likely to immobilize enzyme onto electrode surface for amperometric biosensing application. This hybrid material combined the advantages of inorganic LDHs and organic biopolymer, CHT. Glucose oxidase (GOD) immobilized in the composite material maintained its activity well as the usage of glutaraldehyde was avoided. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH, applied potential and temperature, were explored for optimum analytical performance of the enzyme electrode. The enzyme electrode provided a linear response to glucose over a concentration range of 1 x 10(-6) to 3 x 10(-3) M with a high sensitivity of 62.6 mA M(-1) cm(-2) and a detection limit of 0.1 muM based on the signal-to-noise ratio of 3.  相似文献   

11.
A new amperometric whole cell biosensor based on Saccharomyces cerevisiae immobilized in gelatin was developed for selective determination of vitamin B1 (thiamine). The biosensor was constructed by using gelatin and crosslinking agent glutaraldehyde to immobilize S. cerevisiae cells on the Teflon membrane of dissolved oxygen (DO) probe used as the basic electrode system combined with a digital oxygen meter. The cells were induced by vitamin B1 in the culture medium, and the cells used it as a carbon source in the absence of glucose. So, when the vitamin B1 solution is injected into the whole cell biosensor system, an increase in respiration activity of the cells results from the metabolic activity and causes a decrease in the DO concentration of interval surface of DO probe related to vitamin B1 concentration. The response time of the biosensor is 3 min, and the optimal working conditions of the biosensor were carried out as pH 7.0, 50mM Tris-HCl, and 30 degrees C. A linear relationship was obtained between the DO concentration decrease and vitamin B1 concentration between 5.0 x 10(-3) and 10(-1) microM. In the application studies of the biosensor, sensitive determination of vitamin B1 in the vitamin tablets was investigated.  相似文献   

12.
A modified microbore high-performance liquid chromatography-immobilized enzyme reactor-electrochemical detection system for acetylcholine (ACh) and choline (Ch) was developed. The system used the horseradish peroxidase and a solution mediator ferrocene to convert the analyte into an oxidized ferrocene species which was detected electrochemically by reduction at 0 mV. There was an excellent linear relationship between the concentration of ACh/Ch and the peak height over the range of 1-5000 nmol/l. The limit of detection for ACh was 2 fmol/5 microl (S/N=3:1). Compared with the common method recommended by Bioanalytical System Inc. (BAS), this method exhibits a 200-fold improvement in the detection limit. The ACh and Ch levels in rat brain microdialysate were examined.  相似文献   

13.
Using monomers that polymerize to form electrically conducting polymers, one can control the thickness of the polymer film and the amount of enzyme that can be immobilized in the films. First, an investigation of the major variables that influence the immobilization of glucose oxidase by entrapment in polypyrrole films, prepared by electropolymerization from aqueous solutions containing the enzyme and monomer, was carried out. Then the optimized conditions were used to assess the effects of film thickness on the activity and stability of immobilized enzyme. For the films ranged in thickness from 0.1 mum to 1.6 mum, the resulting apparent activity and stability of the immobilized enzyme were found to be a strong function of the polymer film thickness. Above a thickness of 1.0 mum, the apparent activity of the immobilized enzyme increases linearly with increasing film thickness. The nonlinearity observed for films of thickness less than 1.0 mum can be attributed to the changes observed in the morphology of the resulting polypyrrole films. Furthermore, it was noted that when the glucose oxidase/polypyrrole films are stored in phosphate buffer, at 4 degrees C, the observed rate of loss in apparent activity of the immobilized enzyme is highest for the first few days, also being higher for the thinner films. However, after the loosely entrapped enzyme is leached from the polymer film, the rate of loss in activity is very low indicating that the well-entrapped enzyme, as well as the polypyrrole films, exhibit good stability. Finally, the reproducibility of the immobilization technique is excellent. (c) 1993 John Wiley & Sons, Inc.  相似文献   

14.
A new mediated amperometric biosensor for fructose is described. The sensor is based on a commercially available D-fructose dehydrogenase. The enzyme is incorporated in a carbon paste matrix containing Os(bpy)2Cl2 as redox mediator that achieves electron transfer at 0·1 V (versus Ag/AgCl) with maximum apparent current densities of 1·2 mA/cm2. The dependence of the steady-state current on the loading of the mediator and the enzyme, other electrode construction parameters, the operating potential, the pH and the temperature was studied. In the steady-state mode the response current was directly proportional to D-fructose concentration from 0·2 to 20mM with a detection limit of 35 μM (signal-to-noise ratio, S/N, 3). In the flow injection analysis mode the response current was directly proportional to D-fructose concentration from 0·5 to 15 M with a detection limit of 115 μM (S/N 3). The sensor was used for the determination of fructose in food samples in a flow injection system and validated with a commercial enzyme kit.  相似文献   

15.
A simple and effective strategy for fabrication of hydrogen peroxide (H2O2) biosensor has been developed by entrapping horseradish peroxidase (HRP) in chitosan/silica sol–gel hybrid membranes (CSHMs) doped with potassium ferricyanide (K3Fe(CN)6) and gold nanoparticles (GNPs) on platinum electrode surface. The hybrid membranes are prepared by cross-linking chitosan (CS) with 3-aminopropyltriethoxysilane (APTES), while the presence of GNPs improved the conductivity of CSHMs, and the Fe(CN)63−/4− was used as a mediator to transfer electrons between the electrode and HRP due to its excellent electrochemistry activity. UV–Vis absorption spectroscopy was employed to characterize the different components in the CSHMs and their interaction. The parameters influencing the performance of the resulting biosensor were optimized and the characteristic of the resulting biosensor was characterized by cyclic voltammetry and chronoamperometry. Linear calibration for hydrogen peroxide was obtained in the range of 3.5 × 10− 6 to 1.4 × 10− 3 M under the optimized conditions with the detection limit (S/N = 3) of 8.0 × 10− 7 M. The apparent Michaelis–Menten constant of the enzyme electrode was 0.93 mM. The enzyme electrode retained about 78% of its response sensitivity after 30 days. The system was applied for the determination of the samples, and the results obtained were satisfactory.  相似文献   

16.
In this study, two different approaches were assessed in order to direct the immobilization of a cyclodextrin glycosyltransferase on functionalized silica support, one by amino groups using glutaraldehyde activation (Si-NH-G-CGTase) and other by disulfide bond through the Cys on the enzyme surface (Si-SH-CGTase). The efficiency of the immobilization of the enzyme by the Cys in Si-SH was four times higher than with the amino group linkage in Si-NH-G (2.86% and 11.91%, respectively). After immobilization, the optimum pH remained at 5.5 for the two derivatives and the optimum temperature was 70 °C for the free enzyme, 80 °C for Si-SH-CGTase and 90 °C for Si-NH-G-CGTase. Both preparations were used for continuous production of cyclodextrins, and Si-NH-G-CGTase presented higher total productivity, retaining 100% of its initial activity for at least 200 h, while the Si-SH-CGTase presented only 40% at the same time. The Si-SH-CGTase could be reloaded with new enzymes linked by disulfide bonds and was able to be used for more than 200 h.  相似文献   

17.
The catalytic potential of chloroperoxidase (CPO) immobilized on mesoporous materials was evaluated for the oxidation of 4,6-dimethyldibenzothiophene in water/acetonitrile mixtures. Two different types of materials were used for the immobilization: a metal containing Al-MCM-41 material with a pore size of 26 A and SBA-16 materials with three different pore sizes: 40, 90 and 117 A. The SBA-16 40 A did not retain any CPO. The nature and the pore size of the material affected the catalytic activity of the enzyme as well as its stability. Compared to the free enzyme, the thermal stability of CPO at 45 degrees C was two and three times higher than when immobilized on Al-MCM-41 and SBA-16 90 A, respectively.  相似文献   

18.
Several new types of carriers and technologies have been implemented in the recent past to improve traditional enzyme immobilization which aimed to enhance enzyme loading, activity and stability to decrease the enzyme biocatalyst cost in industrial biotechnology. These include cross-linked enzyme aggregates, microwave-assisted immobilization, click chemistry technology, mesoporous supports and most recently nanoparticle-based immobilization of enzymes. The union of the specific physical, chemical, optical and electrical properties of nanoparticles with the specific recognition or catalytic properties of biomolecules has led to their appearance in myriad novel biotechnological applications. They have been applied time and again for immobilization of industrially important enzymes with improved characteristics. The high surface-to-volume ratio offered by nanoparticles resulted in the concentration of the immobilized entity being considerably higher than that afforded by experimental protocols based on immobilization on planar 2-D surfaces. Enzymes immobilized on nanoparticles showed a broader working pH and temperature range and higher thermal stability than the native enzymes. Compared with the conventional immobilization methods, nanoparticle based immobilization served three important features; (i) nano-enzyme particles are easy to synthesize in high solid content without using surfactants and toxic reagents, (ii) homogeneous and well defined core-shell nanoparticles with a thick enzyme shell can be obtained, and (iii) particle size can be conveniently tailored within utility limits. In addition, with the growing attention paid to cascade enzymatic reaction and in vitro synthetic biology, it is possible that co-immobilization of multi-enzymes could be achieved on these nanoparticles.  相似文献   

19.
An optical biosensor based on glutamate dehydrogenase (GLDH) immobilized in a chitosan film for the determination of ammonium in water samples is described. The biosensor film was deposited on a glass slide via a spin-coating method. The ammonium was measured based on β-nicotinamide adenine dinucleotide (NADH) oxidation in the presence of α-ketoglutaric acid at a wavelength of 340 nm. The biosensor showed optimum activity at pH 8. The optimum chitosan concentrations and enzyme loading were found to be at 2% (w/v) and 0.08 mg, respectively. Optimum concentrations of NADH and α-ketoglutaric acid both were obtained at 0.15 mM. A linear response of the biosensor was obtained in the ammonium concentration range of 0.005 to 0.5 mM with a detection limit of 0.005 mM. The reproducibility of the biosensor was good, with an observed relative standard deviation of 5.9% (n = 8). The biosensor was found to be stable for at least 1 month when stored dry at 4 °C.  相似文献   

20.
A biosensor for trace metal ions based on horseradish peroxidase (HRP) immobilized on maize tassel-multiwalled carbon nanotube (MT-MWCNT) through electrostatic interactions is described herein. The biosensor was characterized using Fourier transform infrared (FTIR), UV–vis spectrometry, voltammetric and amperometric methods. The FTIR and UV–vis results inferred that HRP was not denatured during its immobilization on MT-MWCNT composite. The biosensing principle was based on the determination of the cathodic responses of the immobilized HRP to H2O2, before and after incubation in trace metal standard solutions. Under optimum conditions, the inhibition rates of trace metals were proportional to their concentrations in the range of 0.092–0.55 mg L−1, 0.068–2 mg L−1 for Pb2+ and Cu2+ respectively. The limits of detection were 2.5 μg L−1 for Pb2+ and 4.2 μg L−1 for Cu2+. Representative Dixon and Cornish-Bowden plots were used to deduce the mode of inhibition induced by the trace metal ions. The inhibition was reversible and mixed for both metal ions. Furthermore, the biosensor showed good stability, selectivity, repeatability and reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号