首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background: Comparative field utility of selected HIV-1 assays using homologous collections of serum, urine and oral mucosal transudate (OMT) was determined in adult populations from a tuberculosis hospital and STD clinic in Djibouti, East Africa.Study design: Enzyme immunoassay with confirmatory Western blot was performed on all serum specimens for comparison with rapid, instrument-free assays (SUDS HIV-1, Murex; TestPack Abbott; and COMBAIDS HIV 1 + 2, SPAN Diagnostics) using various specimen sources. Delayed (48 h post-collection) testing was also performed on urine. Sensitivity and specificity for the rapid assays, in descending order, were as follows: serum SUDS HIV-1 assay (100%, 98.3%), serum COMBAIDS assay (98.4%, 99.6%), and OMT SUDS HIV-1 assay (98.4%, 94.5%).Results: The OMT EIA optical density cutoff value was modified resulting in an improved specificity from 89.1 to 99.6%; however, sensitivity decreased from 100 to 98.5%. Urine EIA and rapid assays demonstrated unacceptable test performance for use as a screening test.  相似文献   

2.
We describe the application of a novel HIV confirmatory testing algorithm to determine the primary efficacy endpoint in a large Phase III microbicide trial. 9385 women were enrolled between 2005 and 2009. Of these women, 537 (6%) had at least one positive HIV rapid test after enrolment. This triggered the use of the algorithm which made use of archived serum and Buffy Coat samples. The overall sample set was >95% complete. 419 (78%) of the rapid test positive samples were confirmed as primary endpoints using a combination of assays for the detection of HIV-specific antibodies (EIA''s and Western Blot), and for components of the virus itself (PCR for the detection of nucleic acids and EIA for p24 antigen). 63 (12%) cases were confirmed as being HIV-positive at screening or enrolment and 55 (10%) were confirmed as HIV negative. The testing algorithm confirmed the endpoint at the same visit as that of the first positive rapid test in 90% of cases and at the time of the preceding visit in 10% of cases. Of the 63 cases which were subsequently confirmed to be HIV-1 positive at or before enrolment, 54 specimens contained no detectable HIV antibodies at screening or enrolment. However, 43 were positive using an EIA which detects both HIV antigen and antibody and also had a positive p24 antigen or HIV PCR test, which was highly suggestive of acute infection. There were 6 unusual cases which had undetectable HIV-1 DNA or RNA. In 4 of the 6 cases the presence of HIV-1-specific antibodies was confirmed by Western Blot. One of these cases with an indeterminate Western Blot was a previous vaccine trial participant. The algorithm served the objectives of the study well and can be recommended for use in determining HIV as an endpoint in clinical trials.

Trial Registration

ISRCTN.org ISRCTN 64716212  相似文献   

3.
The accuracy and ease of use of three automated test systems (Behring Opus, Boehringer Mannheim ES300 and bioMerieux Vidas) and their associated assays (Opus HIV 1 + 2, Enzymun-Test Anti-HIV 1 + 2 and Vidas HIV 1 + 2) for the detection of anti HIV-1 and anti HIV-2 in human serum and plasma were investigated by testing them against a panel of 364 well-characterised specimens. The panel included specimens confirmed to contain anti HIV-1 (n = 65) and anti HIV-2 (n = 25), specimens collected during HIV-1 seroconversion (n = 40), specimens (n = 116) which had given spurious reactions in a variety of anti-HIV screening assays, specimens from patients infected with anti HTLV-I (n = 18) and specimens from unselected blood donors (n = 100). Excluding the seroconversion specimens, all three assays were 100% sensitive. Observed specificities ranged from 98.3% to 99.6%. For the seroconversion specimens the Vidas HIV 1 + 2 was the most sensitive overall. All three assays were as sensitive and specific as most of the conventional anti-HIV enzyme immunoassays currently available. The Opus and Vidas systems would be convenient for clinical laboratories handling small to medium numbers of specimens per day. The Boehringer Mannheim ES300 is designed for larger scale use and required more familiarisation.  相似文献   

4.

Background

The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA) and third-generation enzyme linked immunosorbent assay (EIA) for human immunodeficiency virus (HIV) screening and gauge whether the shift from EIA to ChIA could be better in a multiethnic region of China.

Methodology/Principal Findings

We identified a large number of routine specimens (345,492) using two different assays from Jan 2008 to Aug 2011 in a teaching hospital with high sample throughput. Of the 344,596 specimens with interpretable HIV test results, 526(0.23%) of 228,761 using EIA and 303(0.26%) of 115,835 using ChIA were HIV-1 positive. The false-positive rate of EIA was lower than that of ChIA [0.03% vs. 0.08%, odds ratio 0.33 (95% confidence interval 0.24, 0.45)]. The positive predictive value (PPV) of EIA (89.6%) was significantly higher than that of ChIA (76.1%) (<0.001), reflecting the difference between the two assays. The clinical sensitivities of two assays in this study were 99.64% for EIA and 99.88% for ChIA.

Conclusion

Caution is needed before shifting from 3rd to 4th generation HIV tests. Since none of these tests are perfect, different geographic and ethnic area probably require different considerations with regard to HIV testing methods, taking into account the local conditions.  相似文献   

5.
Enzyme immunoassay (EIA) in the rapid diagnosis of gonorrhoea   总被引:1,自引:0,他引:1  
The diagnostic value of a new, modified enzyme immunoassay (EIA) (Gonozyme; Abbott Laboratories, North Chicago III) was evaluated for the rapid antigenic detection of Neisseria gonorrhoeae in endocervical and urethral specimens. EIA results were compared with those of Gram stain (GS) and conventional culture tests. EIA sensitivity and specificity for male patients attending dermatovenerological clinic were 100% and 96.8% respectively in comparison to 86.7% and 96.8% obtained by Gram staining. For female Obstetrics-Gynaecology patients EIA sensitivity of 100% was highly significant compared to 50% sensitivity by the Gram stain. In culture, 30 strains of N. gonorrhoeae were isolated from 125 male specimens and 2 from 105 specimens from females; this suggests a prevalence of N. gonorrhoeae of 24% in males and 1.9% in females. In vitro antibiotic sensitivity testing indicated 55% resistance to penicillin and 43% to ampicillin in these isolated strains; all were sensitive to erythromycin/tetracycline. 12% of the strains were beta-lactamase producers.  相似文献   

6.
评价人类免疫缺陷病毒1+2型抗体检测试剂盒(Dot-ELISA法)检测血清和唾液样本的临床性能。采用对照试验研究,选取背景清晰的研究对象200例,采集同一研究对象的血清和唾液样本,应用万泰生物药业公司生产的人类免疫缺陷病毒1+2型抗体检测试剂盒作为考核试剂,法国生物梅里埃公司生产的人类免疫缺陷病毒抗体诊断试剂盒(ELISA法)作为参考试剂,考核试剂检测结果与参考试剂及研究对象背景进行比较分析。考核试剂检测血清HIV抗体与参考试剂相比较,阳性符合率100%,阴性符合率100%,总符合率100%,Kappa值1.00,一致性为最强;考核试剂检测唾液HIV抗体与参考试剂检测结果相比较,阳性符合率98.78%,阴性符合率100%,总符合率99.50%,Kappa值0.99,一致性为最强。Dot-ELISA法人类免疫缺陷病毒1+2型抗体检测试剂盒对血清及唾液样本检测性能优越,适合HIV抗体快速筛查。  相似文献   

7.
To determine whether there is a delay between the appearance of anti-HIV in serum/plasma and its detection in saliva and urine, salivary and urine specimens were collected from nine individuals who, on the basis of increasing IgG anti-HIV reactivity, Western blot band patterns and presence of strong IgM anti-HIV reactivity in their serum specimens, were believed to have recently become anti-HIV-positive. Serum from 8 of these patients and 3 commercial panels of plasma specimens collected during seroconversion were diluted to mimic the low immunoglobulin concentrations present in saliva and urine and tested in Wellcozyme HIV 1 + 2 GACELISA and four commercial EIAs intended for testing serum specimens. The 9 pairs of saliva and urine specimens were collected between 4 and 43 days (median 24 days) after the first evidence of seroconversion. All were reactive by Wellcozyme HIV 1 + 2 GACELISA and gave optical density/cut off (OD/CO) ratios in the range 3.8 to 9.8 (median 5.2) for dribbled saliva and 2.4 to 10.1 (median 6.3) for urine. Salivary specimens taken with commercial collection devices gave OD/CO ratios in the range 1.6 to 10.6 (median 5.9). In the serum/plasma specimens Wellcozyme HIV 1 + 2 GACELISA detected anti-HIV at higher dilutions than the other assays, often with a 100-fold or more difference. Saliva and urine specimens were all strongly reactive by Wellcozyme HIV 1 + 2 GACELISA. We therefore predict that it would first detect anti-HIV in salivary and urine specimens at about the same time as it becomes detectable in serum/plasma but that other commercial EIAs would not.  相似文献   

8.

Background

HIV infection in Cameroon is characterized by a great viral diversity with all HIV-1 groups (M, N, O, and P) and HIV-2 in circulation. HIV group determination is very important if tailored viral load analysis and treatments are to be applied. In our laboratory, HIV viral load is carried out using two platforms; Biocentric and Abbott depending on the HIV group identified. Biocentric which quantifies HIV-1 group M is a cheap and open system useful in resource limited settings. The objective of this study was to compare the viral load analyses of serologically group-indeterminate HIV samples using the two platforms with the view of reducing cost.

Methods

Consecutive samples received between March and May 2014, and between August and September 2014 in our laboratory for HIV viral load analysis were included. All these samples were analyzed for their HIV groups using an in-house ELISA serotyping test. All HIV-1 group M samples were quantified using the Biocentric test while all other known atypical samples (HIV-1 groups N, O and P) were analyzed using the Abbott technique. HIV group-indeterminate samples (by serotyping) were quantified with both techniques.

Results

Among the 6355 plasma samples received, HIV-1 group M was identified in 6026 (94.82%) cases; HIV-1 group O, in 20 (0.31%); HIV-1 group M?+?O, in 3 (0.05%) and HIV-2, in 3 (0.05%) case. HIV-group indeterminate samples represented about 4.76% (303/6355) and only 231 of them were available for analysis by Abbott Real-Time HIV-1 and Generic HIV Viral Load techniques. Results showed that 188 (81.39%) samples had undetectable viral load in both techniques. All the detectable samples showed high viral load, with a mean of 4.5 log copies/ml (range 2.1–6.5) for Abbott Real-Time and 4.5 log copies/ml (range 2–6.4) for Generic HIV Viral Load. The mean viral load difference between the two techniques was 0.03 log10 copies/ml and a good correlation was obtained (r 2 ?=?0.89; P?<?0.001).

Conclusion

Our results suggest that cheaper and open techniques such as Biocentric could be useful alternatives for HIV viral load follow-up quantification in resource limited settings like Cameroon; even with its high viral diversity.
  相似文献   

9.
The aim of the study was a comparative analysis of diagnostic value of different laboratoty methods conducted on the basis of results of examination of patients during Legionnaires' disease outbreak in town Verkhnyaya Pyshma. Retrospective analysis of laboratory data from 74 patients with diagnosis of Legionnaires' disease was performed. Complex of laboratory methods was used (polymerase chain reaction (PCR), enzyme immunoassay (EIA), immunochromatography). In group of patients with Legionnaires' disease, the highest proportion of positive results (73%) was obtained by the EIA determining total specific antibodies in urine. Determination of antigen in urine by immunochromatographic express-test yielded 52% of positive results. PCR testing of blood specimens yielded positive results in 65% of samples but was low specific, due to that in 19% of patients from control group false-positive results were obtained. Testing of 3 autopsy samples showed that all specimens contained DNA of the causative agent. Performed analysis allowed to recommend complex use of immunochromatographic express-test of antigen detection and identification of total specific antibodies by EIA during mass people examination.  相似文献   

10.
11.

Background

Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results.

Methods

We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests.

Results

A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits.

Conclusions

When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.  相似文献   

12.
HIV vaccine testing in primates is an important method for determining the possibility of vaccine benefit in humans. Goals of HIV-1 vaccination include establishing neutralizing antibodies and a strong CD8(+) T-cell response. We tested a novel vaccine conjugate for its ability to elicit relevant immune responses to HIV proteins and peptides in rhesus macaques. A neutralizing epitope, V3 loop peptide from HIV-1 envelope, was coupled to heat-inactivated Brucella abortus (V3-HKBA). Rhesus macaques were immunized with this conjugate in the anterior thigh. After two immunizations V3-specific antibodies were found in the sera and at mucosal sites. Neutralizing activity of these antibodies was demonstrated by syncytia inhibition assays. Cellular immune recall responses were demonstrated by antigen-specific induction of interferon-gamma and Regulation on Activation Noraml T Cell Expressed and Secreted (RANTES) secretion in vitro. These results confirm and extend preliminary studies in mice that suggest HKBA is an effective carrier that promotes neutralizing antibody secretion at relevant mucosal sites, as well as cellular immune responses that are correlated with viral protection.  相似文献   

13.

Background

Increased access to HIV testing is essential in working towards universal access to HIV prevention and treatment in resource-limited countries. We here evaluated currently used HIV diagnostic tests and algorithms in Cameroon for their ability to correctly identify HIV infections.

Methods

We estimated sensitivity, specificity, and positive and negative predictive values of 5 rapid/simple tests, of which 3 were used by the national program, and 2 fourth generation ELISAs. The reference panel included 500 locally collected samples; 187 HIV -1 M, 10 HIV-1 O, 259 HIV negative and 44 HIV indeterminate plasmas.

Results

None of the 5 rapid assays and only 1 ELISA reached the current WHO/UNAIDS recommendations on performance of HIV tests of at least 99% sensitivity and 98% specificity. Overall, sensitivities ranged between 94.1% and 100%, while specificities were 88.0% to 98.8%. The combination of all assays generated up to 9% of samples with indeterminate HIV status, because they reacted discordantly with at least one of the different tests. Including HIV indeterminate samples in test efficiency calculations significantly decreased specificities to a range from 77.9% to 98.0%. Finally, two rapid assays failed to detect all HIV-1 group O variants tested, with one rapid test detecting only 2 out of 10 group O specimens.

Conclusion

In the era of ART scaling-up in Africa, significant proportions of false positive but also false negative results are still observed with HIV screening tests commonly used in Africa, resulting in inadequate treatment and prevention strategies. Depending on tests or algorithms used, up to 6% of HIV-1 M and 80% of HIV-1 O infected patients in Cameroon do not receive ART and adequate counseling to prevent further transmission due to low sensitivities. Also, the use of tests with low specificities could imply inclusion of up to 12% HIV negative people in ART programs and increase budgets in addition to inconveniences caused to patients.  相似文献   

14.
Four commercial enzyme immunoassays (EIA), namely the Behring Enzygnost EIA (BE-EIA), Abbott IMx, Whittaker CMV STAT Test Kit and Diamedix assay, were evaluated for the detection of CMV IgG. The methods were compared as to sensitivity, specificity, positive and negative predictive values, global agreement, ease of performance and, for a small number of specimens, reproducibility. Discordant results were resolved by using the Gull CMV indirect fluorescent antibody (IFA) method. Our data suggest that all four assays were valuable screening tools for the detection of CMV IgG based on their high sensitivity and high negative predictive value. However, differences were noted in the reproducibility level and in the incidence of false-positive, equivocal and nonspecific results regarding certain tests in particular. In our hands, the Abbott IMx and the BE-EIA ranked high in the performance characteristics for a good screening test, yet the Abbott IMx offers the added advantages of being the easiest to perform and having the most rapid turnaround time.  相似文献   

15.
In this report, we examine the adaptability of commercially available serological kits to detect antibodies markers for viral hepatitis in oral fluid samples. We also assessed the prevalence of hepatitis A, B, and C virus-specific antibodies, and related risk factors for these infectious diseases through sensitivity of the tests in saliva samples to evaluate if oralfluid can be an alternative tool to substitute serum in diagnosis of acute viral hepatitis and in epidemiological studies. One hundred and ten paired serum and saliva specimens from suspect patients of having acute hepatitis were collected to detect antibodies to hepatitis A (total and IgM), hepatitis B (anti-HBs, total anti-HBc and IgM anti-HBc), and hepatitis C (anti-HCV) using commercially available enzyme-linked immunossorbent assay (EIA). In relation to serum samples, oral fluid assay sensitivity and specificity were as follows: 87 and 100% for total anti-HAV, 79 and 100% for anti-HAVIgM, 6 and 95% for anti-HBs, 13 and 100%for total anti-HBc, 100 and 100% for anti-HBc IgM, and 75 and 100% for anti-HCV The consistency observed between antibodies tests in saliva and expected risk factors for hepatitis A and C suggests that the saliva method could replace serum in epidemiological studies for hepatitis A and C.  相似文献   

16.

Background

New rapid point-of-care (POC) tests are being developed that would offer the opportunity to increase screening and treatment of several infections, including syphilis. This study evaluated three of these new rapid POC tests at a site in Southern California.

Methods

Participants were recruited from a testing center in Long Beach, California. A whole blood specimen was used to evaluate the performance of the Dual Path Platform (DPP) Syphilis Screen & Confirm, DPP HIV-Syphilis, and DPP HIV-HCV-Syphilis rapid tests. The gold-standard comparisons were Treponema pallidum passive particle agglutination (TPPA), rapid plasma reagin (RPR), HCV enzyme immunoassay (EIA), and HIV-1/2 EIA.

Results

A total of 948 whole blood specimens were analyzed in this study. The sensitivity of the HIV tests ranged from 95.7–100% and the specificity was 99.7–100%. The sensitivity and specificity of the HCV test were 91.8% and 99.3%, respectively. The treponemal-test sensitivity when compared to TPPA ranged from 44.0–52.7% and specificity was 98.7–99.6%. The non-treponemal test sensitivity and specificity when compared to RPR was 47.8% and 98.9%, respectively. The sensitivity of the Screen & Confirm test improved to 90.0% when cases who were both treponemal and nontreponemal positive were compared to TPPA+/RPR ≥1∶8.

Conclusions

The HIV and HCV on the multi-infection tests showed good performance, but the treponemal and nontreponemal tests had low sensitivity. These results could be due to a low prevalence of active syphilis in the sample population because the sensitivity improved when the gold standard was limited to those more likely to be active cases. Further evaluation of the new syphilis POC tests is required before implementation into testing programs.  相似文献   

17.
应用斑点金免疫渗滤试验(dotimmunogoldfiltrationassay,DIGFA)建立了一种同步快速检测四种抗HIV-1/2IgG抗体的HIV诊断试纸。通过基因工程技术在大肠杆菌中表达了5种HIV抗原蛋白片段(P24,GP41,GP36,GP120V3,GP120C)。这5种抗原蛋白首先被固定在硝酸纤维素膜上,然后滴加待测血清,其中的病毒抗体通过免疫反应与抗原结合,再加胶体金标记的葡萄球菌蛋白A(SPA),待其渗过膜片后,洗涤,即可形成肉眼可见的红色斑点。用已确证的21份HIV阳性血清(其中包括1份HIV-1标准阳性血清和1份HIV-2标准阳性血清)和30份阴性血清进行了试验,结果表明该快速检测方法与ELISA方法无显著差异。该检测方法不需任何仪器,仅凭肉眼即可判定结果,整个检测过程不超过5分钟。与传统的的ELISA法相比,具有方便快速,成本低廉,应用范围广等优点。同时,此HIV快速诊断试纸可以同步检测并区分针对HIV-1和HIV-2感染的不同检测标志物(抗P24、GP41、GP120和GP36抗体),这对提高快速检测的灵敏度和准确性,以及对判断HIV感染者是否临近或已进入AIDS期有着较高的应用价值。  相似文献   

18.
Neff CP  Kurisu T  Ndolo T  Fox K  Akkina R 《PloS one》2011,6(6):e20209
For prevention of HIV infection many currently licensed anti-HIV drugs and new ones in the pipeline show potential as topically applied microbicides. While macaque models have been the gold standard for in vivo microbicide testing, they are expensive and sufficient numbers are not available. Therefore, a small animal model that facilitates rapid evaluation of potential candidates for their preliminary efficacy is urgently needed in the microbicide field. We previously demonstrated that RAG-hu humanized mouse model permits HIV-1 mucosal transmission via both vaginal and rectal routes and that oral pre-exposure chemo-prophylactic strategies could be tested in this system. Here in these proof-of-concept studies, we extended this system for topical microbicide testing using HIV-1 as the challenge virus. Maraviroc, a clinically approved CCR5 inhibitor drug for HIV treatment, was formulated as a microbicide gel at 5 mM concentration in 2.2% hydroxyl ethyl cellulose. Female RAG-hu mice were challenged vaginally with HIV-1 an hour after intravaginal application of the maraviroc gel. Our results showed that maraviroc gel treated mice were fully protected against vaginal HIV-1 challenge in contrast to placebo gel treated mice which all became infected. These findings highlight the utility of the humanized mouse models for microbicide testing and, together with the recent data from macaque studies, suggest that maraviroc is a promising candidate for future microbicide clinical trials in the field.  相似文献   

19.

Background

Health authorities in several countries recently recommended the expansion of human immunodeficiency virus (HIV) antibody testing, including the use of rapid tests. Several HIV rapid tests are now licensed in Europe but their sensitivity on total blood and/or oral fluid in routine healthcare settings is not known.

Methods and Findings

200 adults with documented HIV-1 (n = 194) or HIV-2 infection (n = 6) were prospectively screened with five HIV rapid tests using either oral fluid (OF) or finger-stick whole blood (FSB). The OraQuick Advance rapid HIV1/2® was first applied to OF and then to FSB, while the other tests were applied to FSB, in the following order: Vikia HIV 1/2®, Determine HIV 1–2®, Determine® HIV-1/2 Ag/Ab Combo® and INSTI HIV-1/HIV-2®. Tests negative on FSB were repeated on paired serum samples. Twenty randomly selected HIV-seronegative subjects served as controls, and the results were read blindly. Most patients had HIV-1 subtype B infection (63.3%) and most were on antiretroviral therapy (68.5%). Sensitivity was 86.5%, 94.5%, 98.5%, 94.9%, 95.8% and 99% respectively, with OraQuick OF, OraQuick FSB, Vikia, Determine, Determine Ag/Ab Combo and INSTI (p<0.0001). OraQuick was less sensitive on OF than on FSB (p = 0.008). Among the six patients with three or more negative tests, two had recent HIV infection and four patients on antiretroviral therapy had undetectable plasma viral load. When patients positive in all the tests were compared with patients who had at least one negative test, only a plasma HIV RNA level <200 cp/ml was significantly associated with a false-negative result (p = 0.009). When the 33 rapid tests negative on FSB were repeated on serum, all but six (5 negative with OraQuick, 1 with INSTI) were positive. The sensitivity of OraQuick, Determine and Determine Ag/Ab Combo was significantly better on serum than on FSB (97.5%, p = 0.04; 100%, p = 0.004; and 100%, p = 0.02, respectively).

Conclusion

When evaluated in a healthcare setting, rapid HIV tests were less sensitive on oral fluid than on finger-stick whole blood and less sensitive on finger-stick whole blood than on serum.  相似文献   

20.
IgA has been supposed to play an important role in the prevention of HIV-1 infection. In this study, IgA-binding sites on gp120 and gp41 of HIV-1 envelope glycoproteins were analyzed using ELISA and overlapping synthetic peptides covering all of the gp120 and gp41 sites. IgA antibodies in plasma and saliva mainly bound to six and five sites on gp120 and gp41, respectively. Some of the IgA-binding sites differed from those of IgG-binding sites and the amount of IgA antibodies that bound to each site varied among samples. IgA antibodies in some plasma samples neutralized HIV-1 infection, and those IgA antibodies contained the antibodies which bound to the V3, C3 and ELDKWA sites. The results suggest that IgA antibodies which bind to certain sites on HIV-1 envelope glycoproteins may neutralize HIV-1 infection, presumably at mucosal sites where most IgA antibodies are produced. The induction of IgA antibodies that bind specific sites and neutralize HIV-1 infection at mucosal sites may be important in the development of a vaccine against HIV-1 infection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号